Atec 1001WP User Manual

••
Worldwide Voltage and Frequency Output
••
Test your product for operation anywhere in the world
••
Easy to Use Test Limit Parameters
••
Check for high and low frequency and volt­age conditions
••
Unique Two Stage Current Limit protec-
••
Starts virtually any load within specified rms rated power
••
Universal Input from 85V to 264V,
••
47 to 63 Hz
Use in any country, no need to change input power setup
••
High Efficiency with Input Power Factor
••
Correction
Operates from standard single phase utility power outlets
••
Lightweight and Portable
••
Easy to move between applications, only 30 lb. (13.6 Kg)
Portable Line Power
Model 1001WP / 1251WP
Test Your Product
for Worldwide Use
International Testing
Products manufactured in one coun­try are often used in another. And, though the utility line power may have similar characteristics, often the fre­quency and voltage available at the place of manufacture are completely different.
Traditionally, variacs or auto trans­formers are used for testing products aimed at international markets. This testing covered only different voltage conditions. With the increasing use of microprocessors and logic timing cir­cuits however, products should also be tested at different line frequencies.
ISO 9000 Quality Require­ments
Requirements of international quality standards such as ISO 9000 suggest that products should be tested as they are going to be used. These Califor­nia Instruments supplies represent an new concept to meet the require-
ments of companies who need to test their products for use from nonstand­ard power. The portable, conveniently sized unit delivers a continuous 1000 VA of power. Operating efficiently from a single phase AC outlet, these products put the convenience of in­ternational power at any bench...in the laboratory, the test department, or in the field.
Five Standard Voltage Ranges
Output voltage of 100, 115, 220, 230 and 240 Volts are available to produce all standard world power options. A rear panel switch selects between one of the low voltages and one of the high voltages. The low voltage output is available from a USA Nema 5-15R duplex output. The high voltage out­put is available from the European CEE 7/7 outlet.This prevents the ac­cidental application of high voltage to equipment configured for USA do­mestic use. Selection of either 100/
115 V or 220/230/240 V is via a con­veniently accessible switch. Any com­bination of one high and one low volt­age option is possible. The selected output voltage is indicated on the front panel. Outlets for other countries are available from the optional Interna­tional Socket Strip.
50 and 60 Hz Output Fre­quency
The output frequency can be selected to be either 50 or 60 Hz, independent of the input frequency or output volt­age. Testing of product for operation from a different line frequency with­out first having to design a new power supply or locate a step up or down transformer, is possible. This is es­pecially important for products that rely on line power synchronization. The selected output frequency is also indicated on the front panel.
Simple, Easy to Use Limit Testing
With preset limits at ±10% of the out­put voltage selected, and ±3Hz of ei­ther 50 or 60 Hz, it is extremely easy to test products for operation over nor­mal worst case conditions. The limit switches feature associated LED’s to indicate either the nominal or limit con­dition so that the output status is im­mediately clear.
Low Cost Of Ownership
Careful design, the use of modular con­struction and quality components, all contribute to provide you many years of uninterrupted service. The modular construction allows components or subassemblies to be replaced quickly to minimize downtime.
Ordering Information
Models:
1001WP 1000 VA AC Frequency
Changer.
1251WP 1250 VA AC Frequency
Changer.
Line Cord Options:
Country Part No.
Continental Europe PC11
Australia / New Zealand PC12
UK / Ireland etc. PC13
Denmark PC14
India PC15
Israel PC16
Italy PC17
Switzerland PC19
North America* Note 1
* One North American Line cord is in­cluded.
Note 1: PC21 for 1001WP
PC18 for 1251WP
Supplied with:
North American Line Power Cord
(PC21)
USA and European line output
mating connector
Instruction Manual
Specifications* 1001WP 1251WP Unit
Controller
Type Fixed Controls Push Buttons Readout Voltage LED’s
Output
AC Power 1000 1250 VA Voltage Selectable low range 100, 115 V (L-N)
high range 220, 230 , 240 V (L-N) Accuracy ± 1 % of setting Limit Testing - 10%, nominal, + 10% Line & Load Regulation ± 2 % Max.
Total Harmonic Distortion 1 % typical Output Noise low range 150 mV
high range 500 mV
Frequency Selectable 50 or 60 Hz Accuracy ± 1% Limit Testing -3, nominal, +3 Hz Current Current - Steady State low range 9.0 11.0 A
high range 4.5 5.5 ARMS Peak Current low range 29.0 33.0 A
high range 14.5 16.5 A
Protection
Output Over Current yes Short Circuit yes Over Temperature yes Over Voltage yes
Input
Line Voltage 2 wire + GND 100 - 240 ±10 % VRMS Input Current < 15 < 20 ARMS Line Frequency 47 - 63 Hz Holdup Time 20 ms Power Factor > 0.95 typical Line Cord Input Connector IEC320/C19
Physical
Regulatory CE, UL, CSA Dimensions HxWxD 8.25 x 8.5 x 17.5 inches
HxWxD 210 x 216 x 445 mm Weight 30 / 13.6 lbs / kg Operating Temp. 0-40 / 32-104 °C / °F
* Specifications are warranted for an ambient temperature of 23° + 5° C and apply after a 30
minute warmup period.
RMS
Contact California Instruments:
Toll-Free: 800-4AC-POWER
800-422-7693
FAX: 858-677-0940
Email: sales@calinst.com
Web page: http://www.calinst.com
9689 Towne Centre Drive, San Diego, CA 92121-1964 (858) 677-9040 FAX : (858) 677-0940
© Copyright 2000, California Instruments Corp. Specifications subject to change without notice Printed in the USA. DS-WP 03/00