• Worldwide Voltage and Frequency Output
••
Test your product for operation anywhere in
the world
••
• Easy to Use Test Limit Parameters
••
Check for high and low frequency and voltage conditions
••
• Unique Two Stage Current Limit protec-
••
tion
Starts virtually any load within specified rms
rated power
••
• Universal Input from 85V to 264V,
••
47 to 63 Hz
Use in any country, no need to change input
power setup
••
• High Efficiency with Input Power Factor
••
Correction
Operates from standard single phase utility
power outlets
••
• Lightweight and Portable
••
Easy to move between applications, only 30
lb. (13.6 Kg)
Portable Line Power
Model 1001WP / 1251WP
Test Your Product
for Worldwide Use
International Testing
Products manufactured in one country are often used in another. And,
though the utility line power may have
similar characteristics, often the frequency and voltage available at the
place of manufacture are completely
different.
Traditionally, variacs or auto transformers are used for testing products
aimed at international markets. This
testing covered only different voltage
conditions. With the increasing use of
microprocessors and logic timing circuits however, products should also
be tested at different line frequencies.
ISO 9000 Quality Requirements
Requirements of international quality
standards such as ISO 9000 suggest
that products should be tested as they
are going to be used. These California Instruments supplies represent an
new concept to meet the require-
ments of companies who need to test
their products for use from nonstandard power. The portable, conveniently
sized unit delivers a continuous 1000
VA of power. Operating efficiently
from a single phase AC outlet, these
products put the convenience of international power at any bench...in the
laboratory, the test department, or in
the field.
Five Standard Voltage Ranges
Output voltage of 100, 115, 220, 230
and 240 Volts are available to produce
all standard world power options. A
rear panel switch selects between one
of the low voltages and one of the high
voltages. The low voltage output is
available from a USA Nema 5-15R
duplex output. The high voltage output is available from the European
CEE 7/7 outlet.This prevents the accidental application of high voltage to
equipment configured for USA domestic use. Selection of either 100/
115 V or 220/230/240 V is via a conveniently accessible switch. Any combination of one high and one low voltage option is possible. The selected
output voltage is indicated on the front
panel. Outlets for other countries are
available from the optional International Socket Strip.
50 and 60 Hz Output Frequency
The output frequency can be selected
to be either 50 or 60 Hz, independent
of the input frequency or output voltage. Testing of product for operation
from a different line frequency without first having to design a new power
supply or locate a step up or down
transformer, is possible. This is especially important for products that
rely on line power synchronization.
The selected output frequency is also
indicated on the front panel.
Simple, Easy to Use Limit
Testing
With preset limits at ±10% of the output voltage selected, and ±3Hz of either 50 or 60 Hz, it is extremely easy
to test products for operation over normal worst case conditions. The limit
switches feature associated LED’s to
indicate either the nominal or limit condition so that the output status is immediately clear.
Low Cost Of Ownership
Careful design, the use of modular construction and quality components, all
contribute to provide you many years
of uninterrupted service. The modular
construction allows components or
subassemblies to be replaced quickly
to minimize downtime.
Ordering Information
Models:
1001WP 1000 VA AC Frequency
Changer.
1251WP 1250 VA AC Frequency
Changer.
Line Cord Options:
Country Part No.
Continental Europe PC11
Australia / New Zealand PC12
UK / Ireland etc. PC13
Denmark PC14
India PC15
Israel PC16
Italy PC17
Switzerland PC19
North America* Note 1
* One North American Line cord is included.
Note 1: PC21 for 1001WP
PC18 for 1251WP
Supplied with:
• North American Line Power Cord
(PC21)
• USA and European line output
mating connector
• Instruction Manual
Specifications* 1001WP 1251WP Unit
Controller
Type Fixed
Controls Push Buttons
Readout Voltage LED’s
Output
AC Power 1000 1250 VA
Voltage
Selectable low range 100, 115 V (L-N)
high range 220, 230 , 240 V (L-N)
Accuracy ± 1 % of setting
Limit Testing - 10%, nominal, + 10%
Line & Load Regulation ± 2 % Max.
Total Harmonic Distortion ≤ 1 % typical
Output Noise low range ≤ 150 mV
high range ≤ 500 mV
Frequency
Selectable 50 or 60 Hz
Accuracy ± 1%
Limit Testing -3, nominal, +3 Hz
Current
Current - Steady State low range 9.0 11.0 A
high range 4.5 5.5 ARMS
Peak Current low range 29.0 33.0 A
high range 14.5 16.5 A
Protection
Output Over Current yes
Short Circuit yes
Over Temperature yes
Over Voltage yes
Input
Line Voltage 2 wire + GND 100 - 240 ±10 % VRMS
Input Current < 15 < 20 ARMS
Line Frequency 47 - 63 Hz
Holdup Time 20 ms
Power Factor > 0.95 typical
Line Cord Input Connector IEC320/C19
Physical
Regulatory CE, UL, CSA
Dimensions HxWxD 8.25 x 8.5 x 17.5 inches
HxWxD 210 x 216 x 445 mm
Weight 30 / 13.6 lbs / kg
Operating Temp. 0-40 / 32-104 °C / °F
* Specifications are warranted for an ambient temperature of 23° + 5° C and apply after a 30
minute warmup period.
RMS
Contact California Instruments:
Toll-Free: 800-4AC-POWER
800-422-7693
FAX: 858-677-0940
Email: sales@calinst.com
Web page: http://www.calinst.com
9689 Towne Centre Drive, San Diego, CA 92121-1964 (858) 677-9040 FAX : (858) 677-0940
© Copyright 2000, California Instruments Corp. Specifications subject to change without notice Printed in the USA. DS-WP 03/00