Guardian 1010, 1030 & 1030S
AC Output Voltage: Range: 50V to 5000V AC
Resolution: 1Volts/step
Frequency: 50/60 Hz selectable
Waveform: Sinusoidal
Regulation: +/-(1% of setting +5V)
Voltage Display: Accuracy: +/-(1% of reading + 5V)
Resolution: 1 Volt
AC Current Display: Total and Real Current
Range: 0.001mA to 30mA AC
Resolution: 1µA
Accuracy:+/-(1% of reading + 5cnt) Total
Accuracy:+/-(5% of reading + 20cnt) Real
High/Low Limit Test: Range: 0.001mA to 30mA AC
Low limit can be turned OFF
Guardian 1030 & 1030S
DC Output Voltage: Range: 50V to 6000V DC
Resolution: 1Volts/step
Regulation: +/-(1% of setting +5V)
Voltage Display: Accuracy: +/-(1% of reading + 5V)
Resolution: 1 Volt
DC Current Display: Range: 0.0001mA to 10mA DC
3 Ranges: .0001mA - 0.3mA,
0.31mA - 3mA, 3.1mA - 10mA
Accuracy:+/-(1% of reading + 5cnt)
High/Low Limit Test: 0.1µA to 10mA DC
Low limit can be turned OFF
Charging Current: 10mA max
Insulation Resistance: Range: 0.1MΩ - 50GΩ
1M - 1G: +/- (5% + 10 cts), >500V
1G - 10G: +/- (10% + 10 cts), >500V
10G - 50G: +/- (15% + 10 cts), >500V
0.1M - 1G: +/- (10% + 10 cts), <500V
IR Output Voltage: Range: 50V to 1000V DC
Accuracy: +/-(1.5% of setting +5V)
High/Low Limit Test: 0.1MΩ - 50GΩ
High limit can be turned OFF
Guardian 1030S
Scan Channels: 8 HV Scan Channels
Test Cables: 8 Custom Banana (unterminated)
Common Features
Open/Short Detection: Voltage <100V, Frequency: 600Hz
Open: 10-100%; Short: 100-500%
Common Features
Arc Detection: Arc Level: adjustable OFF or
1mA - 15mA AC & 10mA DC
Arc Duration: > 10µs
Indication: Pass/fail lights, audible sound
Time: Ramp: 0.1 to 999s (+/-20ms), OFF
Test: 0.1 to 999s (+/-20ms), Continuous
Fall: 0.1 to 999s (+/-20ms), OFF
Quick Discharge: Discharge of voltage across DUT back
through the HV transformer
Output Cutoff: <0.4msec after limit exceeded
Ground Continuity: High Limit: 1Ω
Accuracy: +/-0.2Ω
Ground Fault Interrupt: Automatic instrument shutdown for
current imbalance >0.5mA
Standard Interfaces: RS232, Remote
Inputs: Start, Stop and Interlock
Characteristics: 24V Active Low,
Pulse Width >20ms.
Outputs: Pass/Fail/Under Test
Characteristics: Dry Contact relay
Ele. Characteristics: 120V 100mA max.
Logic: Closed if True
Connector: 9 pin Male D-Series
Optional Interfaces: IEEE 488 or Printer
Test Setups: 99 Memory Locations, 99 Steps, max 500
Connectors: Front Connection (HV and RTN)
HV OUTPUT (Custom Banana)
RTN/LOW (Binding Post)
Front Panel Lockout: Key press with or without memory recall
Miscellaneous: Zero Offset
Dimensions: (w x h x d):12.8x4.2x16in
(320x105x400mm)
Weight: 1010 & 1030: 30.5 lbs (14kg) net,
36 lbs (16.5kg) ship
1030S: 32.5 lbs (15kg) net,
38 lbs (17.5kg) ship
Environmental: Meets MIL-T-28800E, Type 3, Class 5
Operating: 0°C to + 40°C
Humidity: <70%
Storage: - 10°C to + 60°C
Power: •90 - 130V AC •50 or 60Hz
•200 - 250V AC •500W max
P r o d u c t S p e c i f i c a t i o n s
Guardian 1010 AC Hipot Tester
Guardian 1030 AC/DC/IR Hipot Tester
Guardian 1030S AC/DC/IR/SC Hipot Tester
Includes:
150665 Instruction Manual
700070 Power Cable
S02 Test Leads
700100 Ground Continuity Lead
Calibration Certificate Traceable to NIST
Lead Set: (8) Unterminated (1030S only)
Optional Accessories:
Calibration Data
S02 HV Lead Set, 1m, (std w/unit)
S03 Corded Product Adapter(115V)
S04 HV Lead Set, 2m
S05 Foot Switch
S06 High Voltage Probe
S07 Power Entry Adapter Cable
S08 Gun Probe
S09 HV Lead, 1 meter, unterminated
S10 HV Lead, 2 meters, unterminated
S11 Gun Probe with remote start
S12 Load Box, resistive
S14 Load Box, custom resistors
S15 Interconnection Cable to S50
G16 International Power Strip
G25 Corded Product Adapter (240V)
G38 Printer Interface(replaces IEEE)
G39 IEEE-488 Interface
G40 Scanner Lead Set (8), with Clips
for G1030S only
Ordering Information
For more detailed information on specifications, pricing and
special purchase, rent and lease options, contact us at:
www.quadtech.com or 800-253-1230
P/N 030093/A6