ATD Tools ATD- 7371, ATD-7370, ATD-7372 User Manual

Air Hydraulic
Operating Instructions & Parts Manual
Model Number
ATD-7370 ATD-7371 ATD-7372
U.S. Patent No’s. 5,341,723 • 5,946,912
Capacity
12 Ton 20 Ton
20 Ton
(low prole)
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
!
Obey all safety messages that follow this symbol to avoid possible injury or death.
! ADVERTENCIA
• Leer, comprender, y seguir las instrucciónes antes
de utilizar el aparato.
• El manual de instrucciónes y la información de seguridad deben estar comunicado en lengua del
operador antes del uso.
• No seguir estas indicaciónes puede causar daños
personales o materiales.
ATD Tools Inc.
160 Enterprise Drive, Wentzville MO 63385
! WARNING
To avoid crushing and related injuries:
NEVER work on, under or around a
load supported only by a hydraulic jack. ALWAYS use adequately rated
jack stands.
Printed in China
ATD7370-M2 rev 02/09
SAFETY and GENERAL INFORMATION
Save these instructions. For your safety, read, understand, and follow the information provided with and on this jack
before using. The owner and operator of this equipment shall have an understanding of this jack and safe operating procedures before attempting to use. The owner and operator shall be aware that use and repair of this product may require special skills and knowledge. Instructions and safety information shall be conveyed in the operator's native language before use of this jack is authorized. If any doubt exists as to the safe and proper use of this jack, remove from service immediately.
Inspect before each use. Do not use if broken, bent, cracked, or damaged parts (including labels) are noted. Any jack that appears damaged in any way, operates abnormally or is missing parts, shall be removed from service immediately. If the jack has been or suspected to have been subjected to a shock load (a load dropped suddenly, unexpectedly upon it), immediately discontinue use until jack has been checked by an authorized factory service center manufacturer for list of Authorized Service Centers) personnel. Labels and Operator's Manuals are available from manufacturer.
. It is recommended that an annual inspection be done by qualied
(contact distributor or
PRODUCT DESCRIPTION
Air Actuated Hydraulic Bottle Jacks are designed to lift, not support, rated capacity loads consisting of one end of a vehicle. Immediately after lifting, the load must be supported by a pair of appropriately rated jack stands. Ensure that air source can dedicate 7.8 CFM @ 110-175 psi. A minimum of 150 psi air pressure is required to raise rated capacity load.
Never use hydraulic jack as a stand alone device. After lifting, immediately support the lifted load
!
with a pair of appropriately rated jack stands. Never place any portion of your body under a load when lifting or lowering the load.
SPECIFICATIONS
Model Capacity
ATD-7370 12 Ton 8" x 6-1/2" 1-5/8" 9-1/2" 18-1/2" 5-1/2" 3-1/2"
ATD-7371 20 Ton 8-1/2" x 7-1/4" 2" 9-3/4" 18-3/4" 5-1/8" 3-7/8"
ATD-7372 20 Ton 8-1/2" x 7-1/4" 2" 8-1/8" 15-1/2" 4" 3-3/8"
Saddle/Extension Screw
Oil Filler Screw/ Plug*
(*) oil ller plug for ATD-7370
Carry Handle
Handle Sleeve
Base Size
(L x W)
Ram
Saddle
Diameter
Air Motor
Min.
Height
Quick Coonnector (N/A for ATD-7372)
Max.
Height
Air Hose
Hydraulic Lift
Lift Control Valve
Screw
Ext.
Release Valve
Handle
Figure 1 - Typical Air Bottle Jack Nomenclature
2
! WARNING
Study, understand, and follow all printed materials provided with/on this product before use.
Do not exceed rated capacity.
This is a lifting device only!
Immediately after lifting, support the load with
a pair of appropriately rated jack stands.
• Use only on hard, level surface.
• Do not use adapters or accessories that are not
provided initially.
• Lift only on areas of the vehicle as specied by the vehicle manufacturer.
• Never wire, clamp or otherwise disable the lift control valve to function by other than operator's
hand.
• No alterations shall be made to this product.
• Failure to heed these markings may result in
personal injury and/or property damage.
To avoid crushing and related injuries:
Never work on, under or around a load supported
only by hydraulic jack.
Always use adequately rated jack stands.
• Chock each unlifted tire in both directions.
Do not use this device to lift, level, lower, support nor move a house, mobile home, travel trailer, camper or any building structure.
Be alert and sober when using this product. Do not operate under the inuence of drugs or alcohol.
Be sure all tools and personnel are clear
!
before lowering load. Only attachments and/or adapters supplied by the manufacturer shall be used.
Lift only on areas of the vehicle as specied by the
vehicle manufacturer.
! WARNING
X
PREPARATION
Before Use
1.
Verify that the product and application are compatible, if in doubt call ATD Technical Service (636) 327-9050.
2. Before using this product, read the operator's manual completely and familiarize yourself thoroughly with the product, its components and recognize the hazards associated with its use.
3. Assemble handle, ensure spring clips align with slots.
4. To familiarize yourself with basic operation, use the notched end of provided handle to engage and turn the release
valve:
a. Clockwise until rm resistance is felt to further turning. This is the ‘CLOSED’ release valve position used to raise the ram plunger. b. Counter-clockwise, but no more than 1 turn from the closed position. This is the ‘OPEN’ release valve position used to lower the ram plunger.
5. With ram fully retracted, locate and remove the oil ller plug/screw. Insert the handle into the handle sleeve, then pump 6 to 8 strokes. Ensure the oil level is just below the oil ller hole. Reinstall the oil ller plug/screw.
6. Pour a teaspoon of good quality, air tool lubricant into the air supply inlet of the lift control valve. Connect to air supply and squeeze lift control valve for 3 seconds to evenly distribute lubricant.
7. This product is equipped with the popular 1/4" NPT air coupler. When installing a different air coupler of your choice, ensure that thread tape or compound is used when servicing connections. To ensure dependable, trouble free operation an inline air dryer and oiler is recommended.
8. Check that the pump operates smoothly and that the extension screw will thread up/down easily before putting into service. Replace worn or damaged parts and assemblies with ATD authorized replacement parts only.
Bleeding / Venting Trapped Air
With the release valve in the OPEN position (4b above) and with ram plunger fully lowered, locate and remove the oil ller plug/screw. Insert the handle into the handle sleeve; then pump 6 to 8 full strokes. This will help release any pressurized air which may be trapped within the reservoir. Oil level should be even with the bottom of the oil ller hole. Reinstall the oil ller plug/screw.
Use only handle provided by jack manufacturer. The handle provided with this jack will safely engage the
!
release valve and operate the handle sleeve. If handle is worn, operates abnormally, or will not positively engage the release valve, STOP, discontinue use of the jack until a factory replacement handle can be acquired.
Paint contains lead! DO NOT sand or grind painted surface!
!
3
OPERATION
Raising the Ram Plunger
1. Assemble handle, ensure that spring clips align with slots.
2. Place vehicle in the park, with emergency brake on and wheel securely chocked to prevent inadvertent vehicle
movement.
3. Locate and close release valve by turning handle clockwise until rm resistance is felt to further thread
engagement.
4. Verify lift point, center jack saddle under lift point.
5. Squeeze the lift control valve or insert handle into handle sleeve and pump to contact lift point. To lift, continue pumping until load reaches desired height. DO NOT OPERATE BY AIR AND BY HAND PUMPING AT THE
SAME TIME.
6. Immediately transfer the lifted load to a pair of appropriately rated jack stands.
Do not use an extender on the air hose or the operating handle.
!
Lowering
Make certain that all personnel are clear of the load before lowering. Control the rate of descent of the
!
load at all times. The more you open the release valve, the faster the load descends.
1. Raise load high enough to clear the jack stands, then carefully remove jack stands (always used in pairs).
2. Slowly turn the handle counter-clockwise, but no more than 1 turn. If the load fails to lower:
a. Use another jack to raise the vehicle high enough to reinstall jack stands. b. Remove the affected jack and then the stands. c. Lower the load by turning the release valve counter-clockwise, but no more than 1 turn.
3. After removing jack from under the load, push ram and handle sleeve down to reduce exposure to rust and contamination.
MAINTENANCE
Important: Use only good grade hydraulic jack oil. Avoid mixing different types of uid and NEVER use brake uid,
turbine oil, transmission uid, motor oil or glycerin. Improper uid can cause premature failure of the jack and the potential for sudden and immediate loss of load. We recommend Mobil DTE 13M or equivalent.
Adding oil
1. With ram plunger fully lowered and pump piston fully depressed, set jack in its upright, level position. Remove oil ller plug/screw.
2. Fill with oil until just below the rim of the oil ller screw hole. Reinstall the oil ller plug/screw.
Changing oil
For best performance and longest life, replace the complete uid supply at least once per year.
1. With ram plunger fully lowered and pump piston fully depressed, remove the oil ller plug/screw.
2. Lay the jack on its side and drain the uid into a suitable container.
Note: Dispose of hydraulic oil in accordance with local regulations.
3. Fill with oil until just below the rim of the oil ller hole. Reinstall the oil ller plug/screw.
Lubrication
1. A periodic coating of light lubricating oil to pivot points will help to prevent rust and assure that pump assemblies
move freely.
2. Air pump should be internally lubricated before each use. Use good quality air tool lubricant. If no inline oiler is used, pour a teaspoon of air tool oil into the air control valve inlet. Operate the jack with air pressure to fully
distribute the oil inside the air motor.
Cleaning
Periodically check the pump piston and ram for signs of rust/corrosion. Clean as needed and wipe with oily cloth.
Note: Never use sandpaper or abrasive material on these surfaces!
Storage
When not in use, store the jack with pump piston and ram plunger fully retracted and air supply disconnected.
4
TROUBLESHOOTING
Symptom
Jack will not lift load
Jack will lift, but not maintain
pressure
Jack will not lower after
unloading
Poor lift performance
Will not lift to full extension
Possible Causes
• Release valve not tightly closed
• Overload condition
• Air pressure inadequate
• Release valve not tightly closed
• Overload condition
• Hydraulic unit malfunction
• Reservoir overlled
• Fluid level low
Air trapped in system
• Fluid level low
• Ensure release valve tightly closed.
• Remedy overload condition.
• Ensure adequate air pressure.
• Ensure release valve tightly closed.
• Remedy overload condition.
• Contact ATD Tech. Service.
• Ensure load is removed, then drain uid to proper level.
• Ensure proper uid level.
• With ram fully retracted, remove oil ller plug/screw to let pressurized air escape, then reinstall oil ller plug/ screw.
• Ensure proper uid level.
ONE YEAR LIMITED WARRANTY
Corrective Action
For a period of one (1) year from date of purchase, ATD Tools Inc. will repair or replace, at its option, without charge, any of its products which fails due to a defect in material or workmanship under normal usage. This limited warranty is a consumer's exclusive remedy.
Performance of any obligation under this warranty may be obtained by returning the warranted product, freight prepaid, to ATD Tools Inc. Warranty Service Department, 160 Enterprise Drive, Wentzville, MO 63385.
Except where such limitations and exclusions are specically prohibited by applicable law, (1) THE CONSUMER'S SOLE AND EXCLUSIVE REMEDY SHALL BE THE REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCTS AS DESCRIBED ABOVE. (2) ATD Tools Inc. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGE OR LOSS WHATSOEVER. (3) ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED TO ONE YEAR, OTHERWISE THE REPAIR, REPLACEMENT OR REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. (4) ANY MODIFICATION, ALTERATION, ABUSE, UNAUTHORIZED SERVICE OR ORNAMENTAL DESIGN VOIDS THIS WARRANTY AND IS NOT COVERED BY THIS WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
5
2
1
3a
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
a
b
c
d
e
f
g
h
i
j
k
l
(
f
or m
o
del
18
2
0
9)
7
12
3b
8
10
22
g
REPLACEMENT PARTS
(refer to page 6 & 7) Not all components of the jack are replacement items, but are illustrated as a convenient reference of parts location. When ordering parts, give part number and parts description. Call or write for current pricing: ATD Tools Inc. 160 Enterprise Drive, Wentzville, MO 63385. Tel:(636)327-9050 Fax:(636)327-9044
Replacement Parts Illustration for model ATD-7370, ATD-7371, & ATD-7372
for model ATD-7372
Figure 2 - Replacement Parts Illustration for Model ATD-7370, ATD-7371, & ATD-7372
6
Replacement Parts List for model ATD-7370, ATD-7371 & ATD-7372
Item Part# for ATD-7370 Part# for ATD-7371 Part# for ATD-7372 Description Qty.
1 A120-10004-000 A190-10002-000 Cylinder Fastener 1
2 A120-10003-000 A190-10001-000 Guide Ring 1
3a 5905-00100-200 N/A Filler Plug 1
3b N/A G62S-03301-000 Filler Screw 1
4 A120-10002-000 Special Washer 2
5 5905-00054-000 Seal 1
6 BT10-24001-000 Release Valve 1
7 5308-00095-000 Gasket 2
8 A27010-0001 A27060-0003 Air Motor 1
9 A27010-0002 N/A Air Inlet Swivel 1
10 A20060-0005 A20060-0015 Hose Assy. 1
11 A20060-0006 Air Hose 1
12 A20060-0007 Lift Control Valve 1
13 B020-15002-000 Washer 1
14 B080-15001-000 Pump Cylinder 1
15 A120-15101-000 Pump Piston 1
16 5115-08033-000 Bolt 1
17 5405-07024-000 Pin 1
18 A120-13000-000 Handle Socket 1
19 5405-02018-000 Snap Pin 1
20 B10N-21000-000 Handle Assembly 1
21 A27010-0011 N/A Air Coupler, Female 1/4 NPT 1
22 A20060-0016 Air Coupler, Male 1/4 NPT 1
23 A27010-0008 Piston, Air Motor 1
24 5206-00008-001 Nut 1
* A1206S-046 A1906S-047 Seal Kit
(includes #4a, 6 & a~l)
- A27010-0000 Seal Kit, Air Motor -
- ATD7370-L0 ATD7371-L0 ATD7372-L0 Label 1
- ATD7370-M2 Manual 1
-
(*) Seal Kit Contents:
Item Description Qty.
3a Filler Plug
(for ATD-7370 only)
5 Seal 1
a Dust Wiper 1 b O-ring 1 c O-ring 1 d Ram Bearing 1 e Back-up Ring 1
(*)- Items included and available only as Seal Kit. Replacement requires special skills, knowledge, and
equipment. Only an authorized service center may perform the repair and/or replacement of these items. Contact ATD technical service for list of service centers.
Item Description Qty.
1
f U-cup 1
g O-ring 2 h Packing 1
i Oil Seal 1 j O-ring 1
k Ram Bearing
l O-ring
(for ATD-7371 & ATD-7372)
(for ATD-7371 & ATD-7372)
1 1
7
ATD Tools Inc.
160 Enterprise Drive,
Wentzville MO 63385
636-327-9050
8
Loading...