ATD Tools ATD-701 User Manual

ATD-701
Non-contact Infrared Thermometer
Instruction manual
1. Introduction
How it works
Infrared thermometer measures the surface temperature of an object. The unit’s optics sense emitted, reflected, and transmitted energy which is collect and focused onto a detector. The unit’s electronics transmitted energy which is display on the unit. For increased ease and accuracy the laser pointer makes aiming even more precise.
Cautions
Infrared thermometer should be protected from the following:
--EMF (electro-magnetic fields) from arc welders, induction heaters.
--Thermal shock (cause by large or abrupt ambient temperature changes allow 1 hour for unit to stabilize before use).
--Do not leave the unit on or near objects of high temperature
.
Warning
Do not point laser at eye or indirectly off reflective surfaces.
1. When take measurement, point thermometer toward the object to be measured and hold the red trigger. The object under test should be larger than the spot size calculated by the field of view diagram.
2. Distance spot size: As the distance from the object
increase, the spot size of measuring area becomes
r.
large
3. Field of view: Make sure the target is larger than the unit’s spot size. The smaller the target, the closer measuring distance. When accuracy is critical, make sure the target is at least twice as large as the spot size.
4. Emissivity: Most organic materials and painted or oxidized surfaces have an emissivity of 0.95. Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape or flat black paint. Measure the tape or painted surface when the tape or painted reach the same temperature as the material underneath.
2. Quick start instruction
1. Press battery door clip, install battery correctly. Pull the trigger, LCD display reading battery icon. Release the trigger and the reading will hold for 7 seconds.
LCD display:
A Laser pointer turn on prompt B Alarm of high temperature prompt C Alarm of Low temperature prompt D Data Hold E Measure result F Emissivity G Temperature unit:℃ H Temperature unit:℉
2. Locating a hot spot aim the thermometer outside the area of interest, then scan across with up and down motions until you locate the hot spot.(please turn on the laser to for accurate measuring)
3. Diagram description
(1) Trigger: Press for turn on, and then display test result
and hold data 7 seconds automatically ("HOLD") after unclamping switch. Turn off automatically after 10 seconds without operate.
(2) Laser pointer button press it for turn on laser
pointer, press again for turn off.
Back light /Up button In “Alarm temperature”
(3)
and “setting emissivity” mode for adjust value up. In other mode for turn on back light. When product working, press it for turn on back light, press again for turn off.
MODE buttonPress MODE button for cycle options
(4)
- MAX - AVG - MIN –HAL –LAL mode AMAXMeasure maximum data current BMINMeasure minimum data current;; CAVG Calculate the average of all measure data D、HALAlarm of high temperature. Option HAL mode, press UP or DNbutton for set alarm temperature. When LCD display ”H” means measure result exceeded the alarm temperature ELALAlarm of low temperature. Option HAL mode, press UP or DNbutton for set alarm temperature. When LCD display ”L” means measure result under the alarm temperature
T/ DN button In “Alarm temperature” and “setting
(5)
emissivity” mode for adjust value down . When turn on product and press direct for /  select.
SET buttonPress for setting emissivity. And press
(6)
“UP or DN” for adjust from 0.1~1.0. Press SET button again for exit setting mode.
(7) LCD display
(8) Battery door: When replace battery, please using
the finger indents to pull open the battery door.
3. Maintenance
1) Lens cleaning: Blow off lose particles using clean compressed air. Gently brush remaining debris away with a moist cotton cloth.
2) Case cleaning: Clean the case with a damp sponge/cloth and mild soap.
3) Please take out the battery when not using for a long time.
Note:
1) Do not use solvent to clean lens.
2) Do not submerge the unit in water.
4. Specifications
Temperature
range
Accuracy
Display spot size 10:1
Repeatability 1%of reading or ±1℃
Response time 500ms
Spectral response 8-14um
Emissivity 0.11.0 adjustable
Relative humidity 10-95% RH non-condensing
Operating temperature Storage temperature
Power Supply 9V 6F22 battery
Battery life Laser models:12 hrs
Product size 165×80×41mm
Product weight 155gwithout battery
Note: Display “AL” means ambient temp lower than 0”; Display “AH” means ambient temp higher than 60℃”; Display above code in normal ambient temp, probable means this meter was broken.
Attached list Applicable Emissivity for Different Material ( For reference only)
Material Emissivity Material Emissivity
Aluminum 0.30 Iron 0.70
Asbestos 0.95 Lead 0.50
Asphalt 0.95 Limestone 0.98
Basalt 0.70 Oil 0.94
Brass 0.50 Paint 0.93
Brick 0.90 Paper 0.95
Carbon 0.85 Plastic 0.95
Ceramic 0.95 Rubber 0.95
Concrete 0.95 Sand 0.90
Copper 0.95 Skin 0.98
Dirt 0.94 Snow 0.90
Frozen food 0.90 Steel 0.80
Hot Food 0.93 Textiles 0.94
Glass(plate) 0.85 Water 0.93
Ice 0.98 Wood 0.94
Infrared-30 to 550(-22 to1022℉)
±3℃or ±3%of rdg,-30℃ to 0℃(-22 to 32) ±2℃or±2% of rdg,0℃ to 100℃(32 to 212℉) ±3℃or ±3% of rdg,≥100℃(212℉)
0 to ~60(32 to 140℉)
-20~60(-4~140) without battery
Loading...