- In order to avoid overheating, do not cover the radiator.
The radiator itself is marked with the standard
“Do not cover” symbol.
- Do Not sit on the radiator.
- This appliance is not intended for outdoor use.
- If the power cord is damaged, it must be changed by the
manufacturer, their after-sales service or persons qualied
to do so, to avoid possible danger.
- The radiator must not be located underneath an electrical
connection. The electric supply line should be protected with
a high sensitivity dierential device (RCBO).
- The radiator must be installed so that around it there is
sucient space for proper circulation of hot air, always
respecting the minimum distances indicated in the LOCATION
section. Anyone who is in the bathtub or shower must not
have access to the switches and other power operation
devices, respecting 0.6 m distance between the radiator and
the bath or shower.
- Mounting is an important part of safety. To perform the correct
installation, go to MOUNTING section.
- This heating apparatus holds a specic amount of special oil.
Repairs where it is necessary to open the oil tank must only
be made by the manufacturer, which should be contacted in
case of any oil leakage.
- This appliance can be used by children aged 8 years and
above and persons with reduced physical, sensory or mental
abilities or lack of experience and knowledge, if they have
A73023520
3
been given supervision or appropriate training regarding the
use of the device in a safe way and they understand the
dangers involved. Children must not play with the appliance.
Cleaning and maintenance must not be performed by
unsupervised children.
- Children under 3 years should be kept out of reach of the
appliance unless they are constantly supervised.
- Children between age 3 and younger than 8 years old should
only turn on / o the device whenever it has been placed or
installed at its normal operating position provided they are
supervised or have received instructions concerning use of
the appliance safely and understand the risks that the device
has. Children from 3 years and under 8 years old should not
plug in, regulate, clean the appliance or perform maintenance.
CAUTION - Some parts of this product can become hot
and cause burns. Pay particular attention when children
and vulnerable people are present.
- If the radiator is discarded, ensure it is recycled responsibly
and follow any local provisions concerning recycling of oil.
- Do not use this heater in the immediate surroundings of a
bath, a shower or a swimming pool.
- Do not use this heater if it has been dropped or if there are
visible signs of damage to it.
- Do not install Radiator covers of any kind over the heater.
- Do not use this heater in small rooms when they are occupied
by persons not capable of leaving the room on their own,
unless constant supervision is provided.
4
A73023520
- To reduce the risk of re, keep textiles, curtains or any other
ammable material a minimum distance of 1 m from the air
outlet.
CONTENTS
1x ATC iLifestyle Wi Smart Radiator
2x Metal Brackets
2x Plastic Covers (top)
2x Locking Plastic Covers
4x Grey Wall Plugs
4x Hex-Head Fixings
1x Instruction Manual
1x Quick Start Guide
1x Quick Start Guide for WiFi connection
Please contact sales@atc.ie if any of the above are missing.
14. CORRECT DISPOSAL OF THIS PRODUCT ........................................................................................ 40
6
A73023520
WiFi SMART FLUID ELECTRIC THERMAL RADIATOR
1. INTRODUCTION
Before switching the radiator on, carefully read these instructions which will help to ensure correct
operation of the device. Keep the instructions for future reference.
2. LOCATION
It is recommended to locate the radiator as close as possible to the coldest wall in the room.
However it is not recommended to install the radiator on external walls without any insulation. If
it is necessary to mount on an uninsulated external wall the section of wall behind the thermal
radiator must be insulated.
In bathrooms, the radiators must not be installed inside restricted areas. In the UK the radiator
must be mounted outside Zone 2. In Ireland the radiator must be mounted outside Zone 3.
The control unit switches must not be reachable, directly or indirectly, by a person in the bath/
shower or using the wash basin.
Classication of the bathroom zones
Under no circumstances may the thermal radiator be
located under an electrical outlet.
A73023520
7
Choose the location of the thermal radiator following the minimum distances indicated below:
Note: If the window sill protrudes less than 20 mm, the gap above the radiator can be disregarded.
3. ELECTRICAL CONNECTION
The iLifestyle WiFi radiator must be connected to the mains supply (230 V ~ 50 Hz.). It is
recommended to install a switched spur for each radiator. In addition, the following warnings must
be taken into account:
The electric radiator must not be located underneath a light switch or any location where
you need to stretch over the radiator to reach or operate the switch.
- The electrical supply circuit should be protected with a high sensitivity dierential device
(RCBO).
- It is necessary to isolate the power in the xed wiring before installation.
Connection wires:
Brown: Live
Blue: Neutral
Yellow-Green: Earth
The connection wires must be of the appropriate cross section, with regard to the length and type
of cable and the power rating of the radiator.
The radiator must be connected into a fused connection box tted with an appropriate sized fuse
for the radiator – see Technical Data on Page 35.
It is recommended that the connection box is positioned 10 cm to the right of the radiator and
15 cm above the oor.
According to regulations, the radiator must be connected to the power supply by means of an allpole circuit breaker with a contact gap of at least 3 mm or by a thermal-magnetic circuit breaker. It
is also recommended to install the radiators on a circuit protected by an RCBO.
8
A73023520
4. MOUNTING
The electric radiator should be xed to the wall by the adjustable width Metal brackets supplied
with the radiator, using the cardboard template printed on the box.
If for any reason cardboard template is missing, please follow the instructions below:
1. Place the two metal brackets provided on the oor and against the wall as shown in image 1
below. Ensure the MB stamp on the metal bracket is at the top.
2. Check Table 1 for the “A” distance between the brackets for your iLifestyle WiFi model.
3. Mark the small hole in the metal brackets on the wall with a pencil. These two marked points
determine the position of the two lower drill holes.
MODEL “A” (mm)
WLS500160
WLS750240
WLS1000320
WLS1200400
WLS1500560
WLS1800720
TABLE 1
4. With the help of a level, position the brackets matching their lower holes with the previously
marked points and mark the upper holes with the pencil.
5. Drill the 4 marked holes. The grey plugs supplied require an 8 mm hole.
6. Insert the grey plugs into the pre-drilled holes. Screw the metal brackets to the wall with the
screws provided. See Image 2.
A73023520
9
7. Attach the plastic pieces to the top
and bottom of the metal brackets
as shown in Images 3 and 4.
8. Hang the radiator as shown below
and in Image 5.
9. To detatch the radiator from the bracket:
1) Push the plastic bracket away from the metal bracket
2) Lift the plastic bracket and pull the base of the radiator
forward away from the metal bracket
10
A73023520
5. OPERATION
5.1 CONTROL PANEL
The control panel is made with a large TFT-LCD screen with white backlight and black images for
ease of legibility. There are six touch sensitive keys, the fuctions are outlined below:
Multi-Function,
selection of mode,
TFT-LCD screen.
temperatures,
parameters, day
and hour, etc.
Keyboard lock
Standby key:
Switch the
radiator between
Standby and
Operational
Conrm modes,
days, hours, etc.Manual mode
Mode key:
Selecting the
operating mode
Go back to the
previous mode /
menu
5.2 TURNING THE RADIATOR ON AND OFF
To switch the radiator on, it must be connected to the electrical supply (230 V ~ 50 Hz) as outlined
in Section 3; the standby icon or the current operating mode will appear on the screen. The
radiator can be turned o or on by turning o or on the power at the fused spur outlet.
If the radiator is in Standby mode, to set it to Operational touch and hold the
Standby key; a double beep will sound once the radiator is Operational.
The standby screen changes to show the welcome screen and then the radiator
will start in the last operating mode.
To congure the radiator in Standby mode, touch and hold the Standby key;
there will be a long beep and the farewell screen will appear.
The back light will turn o after 1.5 seconds.
A73023520
11
If any key is touched when the radiator is in Standby mode, there will be a
short beep and the standby screen will appear. The radiator can be locked from
Standby (see page 31 of this manual).
If there is a power failure or the radiator is disconnected, it will always remember
the last operating mode, the temperature and the status (Standby / Operational
and locked / unlocked).
The day and time will be saved when it is disconnected from the power supply for up to 10 years,
depending on the button cell battery life (replacement cell CR2032). When the battery is depleted,
and after power loss, the day and time must be re-entered, see page 27 of this manual for
details.
If the battery is depleted and the iLifestyle WiFi radiator is linked to a WiFi Network and is online
(i.e. router turned on and radiator is connected), the day and time of the radiator will always be
automatically updated based on the radiator’s congured time zone (in the ATC CALA App).
IMPORTANT: For your safety it is recommended to use an electrican to replace the CR2032 Coin
cell once it is depleted.
Daily and weekly program and the WiFi Connection information, are never lost when disconnected
from power for long periods.
5.3 LINKING THE RADIATOR TO THE WiFi NETWORK
The iLifestyle WiFi radiator has the option to be controlled remotely. In order to operate the iLifestyle
Radiator remotely download the ATC CALA App.
Using the App, the iLifestyle WiFi radiator can be linked to a 2.4 GHz WiFi network.
Scan the QR code below to install the App on either Android or iOS devices.
To manually install from either location, search for “ATC CALA”.
Once the App has been downloaded and installed, the Registration and WiFi Network Linking
process can be carried out.
5.3.1 Radiator Registration and WiFi Network Linking Process
In order to control a radiator from a mobile device the following proccess must be completed:
st
a) Sign up for an account using the Radiator code from the 1
12
radiator.
A73023520
b) Link the radiator to the WiFi network
Note: For the rst iLifestyle WiFi radiator acquired, the process must always follow this order.
Once the App is setup and running, additional iLifestyle WiFi radiators can be set up or connected
to WiFi in any order.
5.3.2 Setting up an account and registering the 1st radiator in the App.
Once the ATC CALA App is installed, register as a new user. Select CREATE NEW ACCOUNT
from the initial Login screen and enter the following requested information.
User details:
• Email address, this will be used to access the App.
• Password, for login security (8 characters minimum).
iLifestyle WiFi Radiator details:
• Radiator code, identies the specic radiator.
To access this information, touch the Mode key and select
the information shown below with the arrows and the OK
key:
• Radiator name, enter a name to identiy where the radiator is
installed.
• Installation name, choose a name for the Installation.
Example: “FAMILY HOME”
Radiators must be be added to an installation. Each installation can contain individual
radiators or groups of radiators in a “zone”. Each installation and the radiators asigned to it
will have the same Time Zone, Currency and Energy Rate.
After clicking on REGISTER, the new user account will have been created and an email message
sent with an Activation Code that will be required to Login.
To complete the account registration select LOGIN and ll in the email address and password.
The App will then ask for the Activation Code, once this is completed the App will ask to link the
Radiator to the local WiFi network.
NOTE: If the linking process is not completed at this time it can be completed later
by touching the WiFi Button within the Installations Menu of the ATC CALA App.
Note: Once an account is created in the App, other iLifestyle WiFi radiators can be added by
selecting the + button at any time.
A73023520
13
5.3.2.1 Linking a radiator to a WiFi network
There are two steps in this process: 1st link the radiator directly to the mobile device, and 2nd Link
the radiator to the local WiFi network.
Once registered or when
adding a radiator to the App,
it will ask to link the heater
to the WiFi network. Touch
CONTINUE to start the linking
procedure.
In Step 1, the procedure to
activate the inbuilt WiFi is
shown on the screen of your
mobile device.
In Step 2, either scan the
network QR Code with
the camera on the Mobile
device or select the WiFi
settings button and select the
“ATC_01” network.
Once the network is
selected and connected
return to the App.
In Step 3, select the WiFi
network shown on the
screen that the heater will be
connected to. Note that it is
only possible to connect to
2.4 GHz Networks which oer
greater signal range.
Stronger signal stength is
shown in green, weaker
signals are yellow and red.
Once the network password
information has been entered
select continue.
14
The radiator is now linked to
the selected WiFi Network.
A73023520
5.3.3 Control of the radiator through Virtual Assistants
Once the ATC CALA App is installed and a user registered with the
App, it is possible to control the App and therefore the iLifestyle WiFi
radiators with Google Assistant or Amazon Alexa.
Information on the use on both of these Virtual Assistants with the ATC CALA App and the iLifestyle WiFi radiators is available by scanning the
following QR code and downloading the instructions.
5.3.4 WiFi Menu
Once the radiator is Operational, in all operating modes except Manual, the
“Modes” menu is displayed by touching the Mode key once. If the heater is in
Manual mode, touch the Mode key twice to access this menu.
In the Modes menu, the desired mode is selected with the p and q keys. To
select and enter the WiFi menu, touch the p key until you reach the rst option,
and touch the OK key.
The WiFi menu displays the information required to manage the connection to the
WiFi network that the iLifestyle WiFi radiator is connected to.
There are 4 or 5 menus within the WiFi menu depending on whether the radiator has been linked
to a WiFi network or not. Each menu item can be selected using the q and p keys and by
touching the OK key when the required menu is highlighted.
From the WiFi menu, the Mode key can be touched to return to the previous operating mode. If no
key is touched for 30 seconds, the radiator will also return to the last operating mode.
5.3.4.1 WiFi Radiator Name
At the bottom of the TFT screen of the WiFi menu, the Name
assigned to the particular iLifestyle WiFi radiator is shown if
it has been registered through the ATC CALA App and once
it has been connected to a WiFi network. The name can be
modied at any time from within the App.
If a WiFi network is linked and connected however no Name
appears in the WiFi menu, it means that the radiator is not
registered with any user in the App.
Note: The radiator can by unlinked from the WiFi network at any time and then be re-linked to
it again or to another network (see next page); in any of these cases, the Radiator Name would
continue to be displayed, as it is still registered in the App.
5.3.4.2 WiFi Radiator Code
The Radiator Code is the unique identier that is required to register the specic radiator in the
App. The “RAD. CODE” menu is the rst item shown in the WiFi menu.
A73023520
15
With RAD CODE selected touch the OK key to display the information screen
which contains the the radiator code displayed in two ways:
• A QR Code, when pairing the Radiator from the App the mobile device’s
camera can be used to register the QR Code.
• A unique 15-Character alphanumeric code that identies the radiator that
can be typed into the “Device Code” eld in the App.
From the “RAD. CODE” screen, if the OK or Mode key is touched, the radiator will automatically
return to the WiFi menu. If no key is touched for 2 minutes, the radiator will return to the last
operating mode.
5.3.4.3 Link WiFi
During registration of the ATC CALA App the rst iLifestyle WiFi radiator is normally linked to the
network. When further iLifestyle WiFi radiators are added, they must be linked to a WiFi network
to be able to be managed remotely.
First, the radiator’s own WiFi Network must be enabled; from the WiFi menu select the “Link WiFi”
option and touch the OK key.
• The iLifestyle WiFi radiator will create it’s own WiFi Network and an information
screen will appear showing the WiFi Network of the iLifestyle WiFi radiator.
The mobile device connects with the WiFi of the radiator (STEP 2 of the
Pairing Process) in one of the 2 following ways:
1 - Scan the QR directly with the camera of the mobile device.
2 - Entering the Network Name and Password shown on the screen:
NETWORK NAME: ATC_01
PASSWORD: 00012108
From the “LINK WiFi” screen, if no key is touched for 5 minutes, the radiator will return to the last
operating mode.
Once the connection process with the App has started, and while the Link WiFi
screen is active, if an error occurs in the process due to:
- An unexpected interruption of the linking process with the WiFi network.
- An Incorrect WiFi password is entered from the App.
- Manual interruption of the process with the OK or Mode key.
The text “NOT LINKED” appears on the screen and the radiator returns to the
WiFi menu.
During the linking process using the App and whilst the Link WiFi
screen is active; once the link between the WiFi radiator and the
WiFi network is successfully completed the word “LINKED” appears.
The Name of the WiFi network is shown on the bottom of the screen.
Once the process is complete the the radiator will return to the last operating
mode.
16
A73023520
Once the radiator is connected to a WiFi network and for as long as it is connected, the WiFi
symbol will appear on all operating screens.
5.3.4.4 WiFi Network
This menu will only appear when the WiFi radiator already has been linked to a WiFi network. It
will continue to be selectable provided it is linked to a WiFi network.
From this menu screen there are 2 options available, which can be selected with the q and p
keys and by touching the OK key when the desired option is highlighted.
From the WiFi network menu, you can touch the Mode key to return to the WiFi menu. If no key is
touched for 30 seconds, the radiator will return to the last operating mode.
1 - DISCONNECT/CONNECT
• Once linked to a WiFi network, the DISCONNECT option will appear at the beginning.
• By touching the OK key, disconnection of the linked WiFi network will be carried out and the
following is shown:
- The disconnect option will then change to CONNECT, you can reconnect to the
same network by selecting Connect and touching OK.
- The network connection symbol at the bottom will change its state to crossed out:
2 - UNLINK WiFi
This option completely disconnects the Radiator from the connected WiFi network.
This leaves the radiator without a WiFi network and it can then be added to another dierent WiFi
network. This is also used if there has been an error when linking to the original WiFi network.
Note: To link a new WiFi network (or re-link it to the same one) it is not necessary to unlink it rst.
When choosing Unlink WiFi with the OK key, the query screen “UNLINK WiFi
NETWORK?” will appear with two options, which can be selected with p and q,
as shown in the image on the right:
- To exit the screen without unlinking, select the CANCEL option and touch
OK, the Radiator will then return to the WiFi Network menu.
- To Unlink, select the OK option, touch OK and the word “UNLINKED” will
appear on the screen, conrming the disconnection. This forgets the WiFi
network that the radiator had been linked to and returns to the WiFi Menu.
The WiFi Network menu will disappear within the WiFi menu.
- If no key is touched for 30 seconds, the radiator will return to the last
operating mode.
The WiFi Network information will appear at the bottom of the screen:
• Network Connection symbol: Connected
A73023520
Disconnected
17
• WiFi Symbol:
The WiFi symbol is shown to the right of the Network Connection symbol. It
represents the range or connectivity of the WiFi radiator with respect to its linked
WiFi network. It will only appear if the linked WiFi network is actually connected.
The symbol is a copy of the WiFi symbol that appears on the operation screens
and only shows once the WiFi network is linked and connected.
Every time the iLifestyle WiFi radiator sends any data or status to the WiFi network, to be shown
in the ATC CALA App (e.g: The initial data at the time it is linked to the WiFi network), as well as
each time the network WiFi sends data to the iLifestyle WiFi radiator from the App (e.g: when it is
remotely controlled to change the set point temperature), the WiFi symbol changes to show the
sequence below, to conrm correct communication:
When the iLifestyle WiFi radiator is linked to a WiFi network and correctly registered in the ATC
CALA App, all operational functions as well as their setpoints can be managed directly by the App
without having to use the radiator’s control panel.
If the radiator has received any change from the App, the TFT screen will not change the level of
brightness, nor will it emit any sound, so as not to disturb occupants of the room.
Any changes applied from the App can be overridden or changed directly from the radiator’s
control panel. This way, in any operating mode, status or conguration applied on the radiator
through the control panel, will be displayed in the App. The status of the radiator is updated in both
the App and control panel if the connectivity is correct.
When the radiator is operational, it periodically sends its room temperature to the ATC CALA App.
In the event that the WiFi network is disconnected or the radiator is without connectivity
the radiator will notify that the communication was lost by showing a crossed out WiFi
symbol:
After reconnecting to the WiFi network or recovering connectivity
to it, the iLifestyle WiFi radiator will show a connected WiFi
symbol and both the app and radiator be synchronised with the
latest information from the ATC CALA App or the local control
panel. The control panel on the radiator has priority over the
information entered from the App.
• Network Name:
The full name or SSID of the linked WiFi network will appear at the bottom of the WiFi Network
menu screen.
This data is used to see which WiFi network the WiFi radiator is linked to in the event of a problem.
18
A73023520
5.3.4.5 WiFi Info
This is an information screen which displays the following content:
1. MAC ADDRESS:
Displays the unique MAC address of each radiator provided by the WiFi module.
2. IP ADDRESS:
The following is shown on the screen:
- IP Address of the radiator on the WiFi network to which it is linked.
-OR-
- IP Address “empty” (...) and the text “NO CONNECTION", when:
• No WiFi network is linked.
• There is a linked WiFi network, but it is disconnected.
• There is a linked WiFi network, but the connectivity is unsuccessful.
In this information screen, touch the OK or Mode key to return to the WiFi menu. If no key is
touched for 30 seconds, the radiator will return to the last operating mode.
5.3.4.6 Firmware Update
The iLifestyle WiFi radiator allows the remote update of the rmware for the electronics, this is
congurable through the last menu within the WiFi menu.
In this menu screen there are 2 options available, select the required option with the q and p
keys and touching the OK key.
Touch the Mode key to return to the WiFi menu. If no key is touched for 30 seconds, the radiator
will return to the last operating mode.
Option 1 - AUTO - 02:00 AM
The rst option allows disabling or enabling the rmware remote
update automatic check for the iLifestyle WiFi electronics, this
setting is enabled by default.
When this option is selected, touching the OK key will disable
or enable the rmware update automatic check.
If the option is enabled, the update automatic check will be carried out daily at 02:00 AM. Also with
the the option enabled,if there is a restart of the WiFi, 10 minutes after the restart the radiator will
check if there is a rmware update.
Option 2 - CHECK UPDATES
In addition to the automatic check, it is possible to check if there is any rmware update available,
regardless if the automatic check is enabled.
A73023520
19
By choosing the second option and touching the OK key, the
query screen “CHECK UPDATES?” is shown with two options:
- If no key is touched for 30 seconds, the radiator will return
to the last operating mode.
- To exit the screen without accepting the action, select
CANCEL and touch OK, the radiator returns to the Firmware
Update menu.
- To proceed, select the OK option and touch the OK key, the
“CHECKING FIRMWARE UPDATES...” screen will appear,
and search for available rmware updates for the current
version of the electronics within the iLifestyle WiFi radiator.
If the update search is run without WiFi network connectivity, either because:
- There is no WiFi network linked.
- The linked WiFi network is disconnected.
- The linked WiFi network is out of connectivity, or too far away.
The search process stops and the “NO CONNECTION” screen is shown, the
radiator then returns to the Firmware Update menu.
If the radiator is linked to a WiFi network, and it cannot nd any upgrades for
the current rmware version of the iLifestyle WiFi radiator, the screen “NO
FIRMWARE UPDATES FOUND” will appear and the radiator will return to the
Firmware Update menu.
If the Mode key is touched once the search process has started, the search
will stop, and the “NO FIRMWARE UPDATES FOUND” will be shown and the
radiator will return to the Firmware Update menu.
If new rmware is found, the data will download and at the end of this process
the radiator will update the rmware. The “FIRMWARE UPDATED” screen will
be shown and then re-start the WiFi Module with the new rmware version. Once
complete the radiator will return to the last operating mode.
At the bottom of the Firmware Update menu screen, the current Firmware Version of the radiator
as well as the Radiator Identity Code are shown. If the rmware update is successful the rmware
version will be updated with the new version number.
5.4 SELECTING THE OPERATING MODE
In the Modes menu, the desired operation mode can be selected
with the p and q keys. Select and enter the operating mode
and touch the OK key.
The radiator will return to the last operating mode if the Mode
key is touched, or after 30 seconds without touching any other
keys.
20
A73023520
In each of the operating modes the screen will automatically switch the display between the current
time and the day of the week.
5.4.1 COMFORT
In Comfort mode the temperature is directly selected using the
p and q keys, available setpoints are between 12 °C and 30 °C
in steps of 0.5 °C. If the keys are held, the temperature changes
faster. When the temperature reaches either the maximum or
minimum value it will stop.
Typical recommended comfort temperature is 20-21.5 °C. The Comfort mode is normally used
during the hours the room is occupied.
5.4.2 ECONOMY
In Economy (ECO) mode, the radiator automatically sets a
temperature of between 0.5 °C and 4.5 °C less than the comfort
temperature (user selectable using the p and q keys). If
you increase or decrease the comfort temperature, the ECO
temperature will increase or decrease accordingly.
Since the comfort temperature is from 12 °C to 30 °C, the ECO temperature is between 7.5 °C to
29.5 °C, but always between 0.5 °C and 4.5 °C below the comfort temperature.
The Economy mode is normally used at night or during short periods of absence. It prevents the
temperature from dropping too much, as it would be expensive to raise it again.
5.4.3 ANTI-FROST
In this mode the temperature is factory set to 7 °C, and is not
adjustable. Anti-frost is usually used as an o set point and for
long periods of absence when you want to avoid freezing.
5.4.4 PROGRAM
In Program mode the radiator automatically switches between 3 mode
temperatures according to the daily and weekly program set by the user.
The daily program display is divided into two screens: the AM screen from 00:00
to 11:59 and the PM screen from 12:00 to 23:59.
The program is displayed using a circle, which represents an analogue clock
face. The screen automatically switches the display between the current time
and the day of the week every 5 seconds.
The program screen is shown permanently and displays its particular 12 hour
program divided into half-hour intervals; the AM and PM programs will be
displayed based on the time of day.
Each half-hour interval of each day of the week can be programmed as:
Comfort, Economy or Anti-frost:
A73023520
21
COMFORTECOANTI-FROST
The current half-hour interval ashes to indicate the current set point. Also, the Sun, Moon or
Frost icon (operation mode icons) is displayed in the middle of the screen above the temperature.
In Program mode Comfort and Eco set points can be directly modied with the p and q keys,
when their particular mode is active (anti-frost set point can never be modied). When the comfort
temperature is increased or decreased, the eco temperature automatically increases or decreases
by the same amount.
Adaptive start control can be applied to Program mode and enabled or disabled in Conguration
mode (see page 31 for details of Adaptive start control function). Program mode is the only
mode in which this function operates.
iLifestyle WiFi radiators come with the predetermined program of Anti-frost for all half-hour
sections of all days.
EDIT PROGRAM: Selection of the day to be set
In Program
mode
Selecting time and mode (after selecting the day)
Move to
the time
with
Select the heating output mode in each time slot:
The time
can be
selected
with 1/2
hour
intervals.
Select the
day with
Select the
time
with
Conrm
with
Conrm
with
COMFORTECOANTI-FREEZE
Only select OK after completely programming the entire day
22
Changes
saved
A73023520
Copy daily programme
If you want to copy the complete program of a particular day to the next day or consecutive days:
Select the day
you want to
copy
with
To exit and return to the Program mode from the editing screen, touch the key.
When editing a program, if no keys are touched for 30 seconds, the radiator will return to Program
run mode.
Hold the OK
key
The
copied days
appear in
succession
copying the
day forward
When you
reach the
day you
want
Release
the key
5.4.5 ENERGY Menu
This menu registers and displays the electric radiator’s estimated energy consumption and its
associated estimated cost. It contains 4 types of Energy Meters, each dierent depending on the
selected period of time.
Note: In the ATC CALA App this feature is available but independently of the radiator, the settings
on the radiator are not synchronized with the App.
On the main screen there are 3 possible selections, which can be chosen with the q and p keys
and selected by touching the OK key when the desired menu is highlighted:
METER TYPERATERESET
Whilst in the Energy menu, if the Mode key is touched, the radiator will automatically return to the
last operating mode. If no key is touched for 30 seconds, the radiator will also return to the last
operating mode.
5.4.5.1 Energy Meter Type
This selection is the main part of the Energy menu, where when choosing the type of Energy
Meter, all the energy consumption information registered in the corresponding period is displayed
underneath it. Select the meter type (as shown above) and touch OK.
There are 4 Meter options to select, depending on the time period required:
A73023520
23
- DAILY - Consumption of the last 24 hours - Updated every hour.
- WEEKLY - Consumption of the last 7 days - Updated Daily at 00:00.
- MONTHLY - Consumption of the last 30 days - Updated Daily at 00:00.
- TOTAL - Total consumption registered, up to 10 years - Updated Daily at 00:00.
To select the type of meter, use the q and p symbols shown beside the time period, each touch of
the button will change the display to show the consumption information registered by each meter:
The default meter is the Daily Meter, to set a dierent meter as default, touch the OK key once the
required meter is selected. It will save as default and be displayed the next time the meter type
menu is entered.
The information shown in each Meter consists of the following:
- Registered Period: Number of hours or days (depending on the meter type) that has been
recorded.
- Consumed Energy: Measure of energy consumed in the registered period, in kWh.
- ESTIMATED Cost: Cost estimated and calculated on the consumed energy, based on the
rate applied and congured (see next section).
When the radiator is disconnected from the mains, even if there is no energy consumption (0
kWh), the time period of each meter will continue to count until it has reached the maximum.
If the button cell battery runs out whilst the power supply is disconnected, the meters will stop until
the radiator is powered up again (the count will restart if the battery is replaced). The registered
values of each meter are not lost unless they are manually reset.
Note: The App will only be able to correctly register the energy consumption that each iLifestyle WiFi
radiator sends each hour.
5.4.5.2 Rate
This menu must be initially congured to calculate the estimated cost of the electric radiator’s
consumption. There are 2 types of rates depending on the time of day:
Reduced Rate -> Default price: 0.100 €/kWh -> Applied during the congured Period.
Standard Rate -> Default price: 0.150 €/kWh -> Applied for the rest of the day.
24
A73023520
When accessing the Rate menu with the OK key, the following screens appear:
There are 4 options to congure; When q or p is touched, the option changes position and
screen depending on whether switching between Standard Rate and Reduced Rate:
• Whenever changing between each of the 4 options, once in the required option, touch OK.
The symbols q and p will appear at the side of the screen or beside the item to be changed.
• To modify the value, touch the p or q keys. Holding the key down will change the value
quickly.
In the Rate menu, if the Mode key is touched, the radiator will return to the Energy menu. If no key
is touched for 30 seconds, the radiator will return to the last operating mode.
Reduced Rate Conguration:
To set a Reduced Rate, the time period and price must be set.
Reduced Rate Period:
The Reduced Rate applies from Start Time to End Time. If within the 24-hour period, the Start
Time is “later” than the End Time, the entire period possible is applied until the End Time occurs,
even if it falls on the next day. For example, it is possible to congure:
Start Time: 23:00
End Time: 06:00
In this example, the duration of the reduced rate would be 7 hours, with the standard rate applicable
from 06:00 to 23:00.
To return to a single Standard Rate, set the Start Time and End Time to exactly the same time,
either 00:00 (default option), or any other time as long as they are the same.
Reduced Rate price with respect to Standard Rate price.
The Standard Rate price can always be congured or modied. The price of the Reduced Rate
can never be greater than the price of the Standard Rate.
5.4.5.3 Reset
The last option in the Energy menu is the Reset function, there are 3 menu options, which can be
selected with the q and p keys:Type of METER to Reset // OK // CANCEL
A73023520
25
Selecting the “Type of Meter” to reset, shows the DAILY total, however it is possible to select any
of the other three available WEEKLY / MONTHLY / TOTAL meters.
When the OK key is touched whilst the “Type of Meter” to Reset is selected, use p and q to select
which one should be reset. To conrm the selection is correct, touch OK again.
- When the OK key is touched while the OK option is selected, it will reset the selected type of
meter, as well as the meters with a period less than the one selected. i.e. Selecting Monthly,
will reset Monthly, Weekly and Daily.
When the meter or meters are reset, all the energy consumption values will
be reset to 0:
“DONE” will appear on the screen, conrming the meter reset.
- Touching the OK key with CANCEL selected, will return to the Energy menu.
In the Reset menu, touching the Mode key will automatically return to the Energy menu. If no key
is touched for 30 seconds, the radiator will return to the last operating mode.
5.4.6 CONFIGURATION Menu
Conguration menu allows the user to set parameters and
functions for the other modes.
There are 9 menus in Conguration menu which can be selected
by q and p keys, and touching the OK key when the desired
menu is highlighted.
When nished, the Mode key can be touched to return to the previous mode. When no keys are
touched for 30 seconds, the radiator will return to the previous operation mode.
5.4.6.1 Brightness level at rest
This menu sets the level of brightness that the radiator will show when it is at rest; this is the
brightness level of the screen kept after the time selected in menu 2.
There are 4 levels to choose from:
0: O.
2: 65 % brightness.
The level can be adjusted using the p and q keys and conrmed with the OK key; the radiator
26
1: 25 % brightness.
3: 100 % brightness.
(this is the level when any key is touched)
A73023520
will then return to the Conguration screen.
5.4.6.2 Maximum brightness Time
This menu sets the time (in seconds) that the radiator screen is at 100 % brightness, from the time
that the last key is touched, before going to rest.
The time value can be changed between 1 and 240 seconds. The time can be adjusted using the p and q keys; if the keys are held then the time changes faster. Conrm the selection by touching
the OK key; the radiator will then return to the Conguration screen.
5.4.6.3 Setting the time
This menu is used to initially set the time and day, and also to
change the time if required, for example, during daylight saving.
Use the p and q keys to select either the day of the week, or
(if the day is correct) the time to be modied. Touch OK to enter
the desired section to change.
Select the day with the p and q keys; you can choose from Monday to Sunday and conrm the
correct day by touching OK.
When setting the time, the setting starts with the hour; select from 00 to 23 using the p and q
keys. Once the hour is correct, touch the OK key; the radiator will change to set the minutes,
selecting from 00 to 59 using the p and q keys and conrm by touching OK.
To go back to the Conguration screen, touch the Mode key at any time.
Daylight saving time will need to be manually changed.
When the button cell battery life ends (see
page 12), and after a power failure or
disconnection from the mains the radiator will
request the user to set the hour/day, as the
system clock is reset to Monday 00:00.
The battery icon will ash until the hour/day is set.
After 30 seconds the radiator will choose Monday and 00:00 as the day and time
and will return to the last used mode of operation.
The radiator will request the time to be set each time there is a power disconnection
or until the button cell is replaced.
Note: It is not necessary to use this menu when the radiator is linked to a WiFi network as it
will automatically obtain the correct updated time. If the iLifestyle WiFi radiator is registered
in the ATC CALA App, the time will be updated to the Time zone of the Installation in which
the radiator is installed.
A73023520
27
5.4.6.4 Power Limitation
This function allows the reduction of the radiator’s average consumption manually. If there is
radiator with a specific output for a room with a particular volume (m3), the radiator can be set to
use less power if it is used in a smaller room that has less volume.
The value will be a percentage of the full power of the radiator with regard to its normal full
value:
- Maximum value: 100 % (default value of the radiator)
- Minimum value: 20 %
- Steps: 5 %
Example: Consumption in one hour:
Radiator 1000 W -> PL value = 100 % -> Consumption: 1000 Watts (Full Consumption)
Radiator 1000 W -> PL value = 80 % -> Consumption: 800 Watts (Reduced Consumption)
The specic Power Limit value can be decreased or increased with the q or p keys. When the
desired value has been set conrm with the OK key; the radiator will then return to the Conguration
screen.
5.4.6.5 Open Windows
This menu enables/disables the Open Windows function (seepage 30of this manual). Select
ON/OFF with the p and q keys and conrm with the OK key; the radiator will return to the
Conguration screen after the selection is made.
5.4.6.6 Adaptive start control
This menu enables/disables the Adaptive start control function (seepage 31 of this manual).
Select ON/OFF with the p and q keys and conrm with the OK key; the radiator will return to the
Conguration screen after the selection is made.
5.4.6.7 Language
This menu is used to set the display language on the screens:
• SPANISH
• ENGLISH
Select the preferred language with the p and q keys, and conrm with the OK
key. The radiator will update the language of all screens.
5.4.6.8 Currency
Currency type to be used for data and settings of the Energy menu:
Euro (€) / Pound sterling (£)
Select the preferred currency with the p and q keys, and conrm with the OK key; the radiator
will return to the Conguration screen after the selection is made.
28
A73023520
5.4.6.9 Reset factory defaults
This menu is used to reset the radiator back to the default factory settings:
• The radiator is unlinked from the WiFi network, its Name is removed from the screen
and in the ATC CALA App it is removed from the user account to which it was registered,
• Comfort set point is 20 °C,
• Economy set point is 16.5 °C,
• The Program is set to Anti-frost for all half-hour sections of all days,
• The 4 Energy Meters are reset to 0,
• The Rates conguration returns to the default values (page 24),
• The day is set to Monday,
• The time is set to 00:00,
• Brightness level at rest is set to 1,
• Maximum brightness Time is set to 10 seconds,
• Power Limitation is set to 100 %,
• Open Windows and Adaptive start control are disabled,
• The language is set to English,
• The currency is set to €,
• The radiator automatically returns to Standby mode.
5.5 HEATING AND TEMPERATURE DISPLAY
When the room temperature is below the temperature set point, the radiator will turn the element
on to raise the room temperature. To show the user that the radiator is heating there is an icon of
a thermometer being lled in the top right hand corner:
The room temperature is normally shown on the display; the set point temperature is only
displayed when the user attempts to change it; after the setting has been adjusted the display will
revert back to the room temperature.
The comfort and eco set point temperatures can be modied both from Comfort and Economy
modes, and also within Program mode if they are active at the time (the anti-frost set point can
never be modied).
5.6 MANUAL MODE
The Manual mode is designed to allow a user to override the Program mode without having to
change the program itself. For example, if you arrive when the radiator is normally unheated, you
can heat the space to a comfortable temperature, and then ensure that the radiator returns to its
normal mode without changing the program.
A73023520
29
It allows the user to manually operate the radiator and override the current setting. It is able to
force the radiator to heat or not for a set amount of time. After the time expires, the radiator will
return to the previous mode of operation.
To enter Manual mode, touch the suitcase key and then use the p and q keys
to enter the amount of time you want to force the radiator to heat or not.
First the number of days is selected; enter between 0 and 365 days and
conrm using the OK key. If you only want a few hours, touch OK to enter
0 days.
The menu the moves to the number of hours selection. The user is able to enter the amount of
time to operate in 1 minute increments up to 1 hour, after which time the steps increase to 30
minute increments. When the total desired time is entered, conrm with the OK key.
Please note the default minimum time is 30 minutes, however this can be decreased using
the q key.
Finally, the desired temperature can be set by the p and q
keys; any temperature between 7 °C and 30 °C (in steps of
0.5 °C) can be entered. Unheated mode can be entered from
either 7 °C or 30 °C by touching the q or p keys once from
each extreme. Unheated mode is displayed with 4 dashes on
the screen (- - - -). When the desired temperature is entered
conrm with the OK key. The screen will display “DONE”.
If no key is touched within 30 seconds before nal conrmation, or the Mode key is touched, the
radiator will return to the previous mode of operation.
The selected time will remain on the display and count down until it is nished.
Although the set time cannot be changed, it is possible to change the set point
temperature during the operation of Manual mode.
Once the set time has elapsed, the radiator will automatically return to the
previous mode of operation.
To exit Manual mode at any time, touch the Mode key and the radiator will return
to the previous mode of operation.
In the case where the power is disconnected to the radiator, the Manual mode settings will be
saved and the remaining time will count down even though the radiator is powered-o.
5.7 OPEN WINDOWS FUNCTION
When the Open Windows function is enabled in the conguration menu
the radiator automatically stops heating when it detects a sudden drop
in the temperature (4 °C in 20 minutes). This is normally caused when a
window or door is opened to the outside without turning o the radiator.
When the Open Windows function has been activated, it will be shown on the
display by a single screen with an open window.
In order to enable the heating again, the user must touch the Mode key. The radiator will then
return to the previous mode of operation.
30
A73023520
Note: In installations where this function is activated very frequently, it may be appropriate to keep
it disabled.
* This function is considered by Directive 2009/125/EC regulations and will give the unit
more eciency during operation.
5.8 ADAPTIVE START CONTROL FUNCTION
When the Adaptive start control function is enabled in the Conguration menu, the radiator
automatically starts heating prior to the programmed time (a maximum of 2 hours before), to
ensure that the next “on” set point is reached eciently.
The radiator analyses the next two hours, and if there is a set point higher than
the current room temperature within that period, and knowing the heating speed
of the unit, the software calculates when it needs to start heating. This calculation
is made every 5 minutes.
This function only runs when the radiator is in Program mode. When Adaptive
start is running, a ashing clock icon is displayed next to the thermometer icon.
This function will only operate on temperature rise, e.g., from anti-frost to eco/
comfort, or from eco to comfort.
When Adaptive start is running the radiator progressively increases the set point temperature until
the next programmed set point is reached.
* This function is considered by Directive 2009/125/EC regulations and will give the unit
more eciency during operation.
5.9 KEYBOARD LOCK
The user can lock the radiator keyboard by touching and
holding the p and q keys down together; the keyboard can be
unlocked in the same way.
When the keyboard is locked or unlocked, the screens on the
right are displayed.
When the radiator is locked, the padlock icon will appear in the upper area of the screen. It is
possible to lock the radiator in all modes, even Standby mode.
Note: The keyboard lock and unlock actions can also be performed from the ATC CALA App if the
radiator is linked to a WiFi network.
5.10 INTERNAL PARAMETERS CONFIGURATION
There are two user congurable internal parameters in the iLifestyle WiFi radiator. By design they
are not meant to be changed often.
A73023520
31
Although both are internal parameters of the radiator, they can also be congured through the ATC
CALA App if the radiator is connnected to an account.
To access the parameter selection menu, touch and hold the OK and Mode keys for 5 seconds
until the menu appears on the display.
There are two xed values on the screen that cannot be modied:
- The rst line shows the Firmware Version of the radiator.
- The last line, at the bottom, shows the radiator Code.
This information may be required if you need to contact technical support
regarding your radiator. They are not user-adjustable values and are only shown
for information.
Param. 0: Internal Parameter 0
The rst line is parameter 0, this is an internal production parameter which is set on manufacture
of the radiator. Under no circumstances should it ever be modied.
Touching OK key with parameter 0 ashing will move the the rst adjustable parameter.
Param. 1: Temperature Oset
The rst user adjustable parameter on the menu is the temperature sensor probe correction
setting. Adjustment of this value is used in case the temperature measurement shown on the
display of the radiator is very dierent from temperature measurements in the space.
For example, the radiator stops heating before the actual room temperature reaches the selected
set point temperature of 21 °C; the radiator stops when the actual room temperature is only 19
°C. As the actual room temperature remains 2 °C below the set point, a value of -2.0 should be
entered to the incorrect measurement shown on the display.
The probe correction value is set using the p and q keys, in steps of 0.1 °C. The value can range from -5 °C to + 5 °C. Conrm the set point by touching the OK key. The menu will then move to
the second parameter.
Param. 2: Easy Mode
The second user adjustable parameter on the menu allows the selection of an “Easy Control”
method to control the radiator.
1P: 1P is the default value (Normal Mode) and will allow full control over all the features of the
radiator. All the functions detailed in this manual are available in 1P.
2P: 2P will enable EASY MODE page 33); this is the easiest way to control the radiator.
Select either 1P or 2P using the p and q keys, and conrm by touching the OK key. Touching the OK key in this last parameter will exit the Internal Parameters Conguration into the selected
Mode (1P or 2P).
During the conguration of the internal parameters, if no key is touched for 30 seconds, the radiator
will return to the previous mode of operation.
32
A73023520
5.11 EASY MODE
Once the radiator is set into the Easy Mode, it will only allow the user to increase and decrease
the temperature setting or set the radiator operational and standby.
There is no access to the clock, mode or conguration changes and no keyboard lock, just the
heating icon showing if the radiator is currently heating, the current room temperature and the WiFi
symbol showing if the radiator has a WiFi network linked or not.
Only the Standby, p and q keys are operational.
The conguration values are set as shown below and cannot be modied in Easy Mode:
1 - Brightness level at rest: Level set in 1P (Normal Mode).
2 - Maximum brightness Time: Time set in 1P (Normal Mode).
3 - Open Windows: OFF.
To modify the brightness values used by the radiator in Easy Mode (2P), they must be previously
set in Normal Mode (1P). The Open Windows function will always be disabled in Easy Mode,
regardless of its setting in Normal Mode.
The radiator temperature set point is adjustable with the p and q keys between 12 °C and 30 °C,
in steps of 0.5 °C.
If the radiator is set into the Easy Mode without having been linked to a WiFi network, it will not
be able to be linked until it is set into the Normal Mode again and then follow the required steps.
Once the iLifestyle WiFi radiator has been linked to a WiFi network, it can be set into the Easy
Mode and then be remotely controlled using the ATC CALA App, but with the simple control
options outlined previously.
Through the App, the iLifestyle WiFi radiator can be set in Normal Mode or Easy Mode at any time.
Note:
When remotely controlling a radiator in Easy Mode by the ATC CALA App, its brightness level at
rest and its maximum brightness time can be directly congured, without previously setting it in
Normal Mode.
The new congured values will be used if returning the radiator to Normal Mode.
A73023520
33
6. ERROR CODE INFORMATION
There are 4 possible errors that the electronics of the iLifestyle WiFi radiator can detect; if an error
is detected, one of the following codes will be displayed on the screen until it is resolved:
ERROR CODEDESCRIPTION
ERROR1Failure in microcontroller, EPROM or other PCB component.
ERROR2Failure of the NTC probe (e.g. disconnected, short-circuited, etc.)
E3
(Flashing symbol)
E4
(Flashing symbol)
Failure in the WiFi module (damaged module).
Continuous failure over time in the WiFi communication.
When recovering from error 1 or 2, the radiator will always go to Standby, without retaining any
previous mode or state. If the radiator goes to Standby without any specic reason, it may have
recovered from either error 1 or 2.
Errors 1 and 3 require the replacement of the electronics, as there is a problem with a PCB
component. Error 2 requires the replacement of the NTC temperature probe.
Errors 3 and 4 (E3 and E4) are failures related with the WiFi communication. Both errors are
simply displayed with “E3” or “E4” on the location of the WiFi symbol.
Although the radiator can immediately detect error 3, whether linked to a WiFi network or not, error
4 can only be detected when the radiator is linked to a WiFi network.
Error 4 is shown by a radiator linked to a WiFi network when detecting a WiFi communication
problem (displaying the crossed out WiFi symbol), that persists for at least 24 hours from when the
issue is rst detected. Then, the crossed out WiFi symbol changes into “E4”:
When error 4 is detected, the iLifestyle WiFi radiator automatically enters Standby for security
reasons; however, it can then be returned to operation again and be controlled with the control
panel but without communication until the error is resolved.
If the radiator is set to Operational through its control panel but error 4 is not resolved, after 24
hours without touching the keyboard, it will return to Standby again until the error is resolved or the
radiator is unlinked from its WiFi network.
If error 4 was due to a WiFi network outage or range issue, the error may be resolved by restoring
connectivity to the entire system and at the correct distances between the router and the radiator.
In this case, the connected WiFi symbol will be displayed. If however the problem persists with the
entire system connected at the correct distance, the electronics should be replaced.
34
A73023520
7. MAINTENANCE AND CARE
iLifestyle WiFi radiators require very little maintenance. In order to clean the radiator, it is
recommended that the electric power is switched o. Wipe the outside of the product and clean
the inside channels with an appropriate brush. Do not insert ngers the inside channels.
The surfaces of the radiator must not be cleaned with an abrasive product or those containing
granular substances. We recommend regular cleaning with PH neutral products.
Failure to keep the iLifestyle WiFi radiators clean may result in dust becoming burnt and
depositing on the wall above the heater in the form of dark streaks or patches. This type of
marking is expressly due to failure to keep the heater and surrounding area clean.
ATC take no responsability for any such damage caused.
The radiator should not be covered at any time; however if the radiator is covered by wet clothes
it is possible for dye to stain the surfaces of the radiator. Check the labelling on the clothing for
We, the undersigned, certify and declare under our sole responsibility that the product designated in this Declaration complies with the following specifications and bears the CE mark above in accordance with the provisions
the following specifications:
2011/65/EU RoHS Directive EN 60335-1:2012 + AC:2014, + A11:2014 +
2012/19/EU WEEE Directive A13 2017 + A14:2019 + A1:2019 + A2:2019 +
2014/35/EU LVD Directive A15:2021
2014/30/EU EMC Directive EN 60335-2-30:2009 + AC:2010 + A11:2012 +
2014/53/EU RED Directive AC2014: + A1:2020 + A12:2020
2009/125EC Eco Design Directive EN IEC 61000-3-2:2019 + A1:2021
EN 61000-3-3:2013 + A1:2019 + A2:2021
EN IEC 55014-1:2021
EN IEC 55014-2:2021
EN301489-1 V2.23
EN 301489-17 V3.24
We, the undersigned, certify and declare under our sole responsibility that the product designated in this Declaration complies with the following specifications and bears the UKCA mark above in accordance with the
provisions the following specifications:
2012 No. 3032 RoHS Regulation 2012 BS EN 60335-1:2012 + A15:2021
2013 No. 3113 WEEE Regulations 2013 BS EN 60335-2-30:2009 + A12:2020
2016 No. 1091 EMC Regulations 2016 BS EN IEC 61000-3-2:2019 + A1:2021
2016 No. 1101 Electrical Equipment (Safety) Regulations 2016 BS EN 61000-3-3:2013 + A1:2021
2017 No. 1206 Radio Equipment Regulations 2017 BS EN IEC 55014-1:2021
2019 No. 539 Eco Design Regulations 2019 BS EN IEC 55014-2:2021
EN301489-1 V2.23
EN 301489-17 V3.24
Date of sale Stamp and signature of the distributor
WARRANTY CERTIFICATE
GUARANTEE: ATC with address: ATC House, Broomhill Drive, D24 EF99, Tallaght, IRELAND
PRODUCT: This warranty is applicable to the products contained in this manual
WARRANTY: 24 months from Date of Purchase (Proof of sale required)
ATC assures the electronics in the control panel have a warranty of 2 years from the date of purchase.
ATC assures the aluminium elements that make up the radiator body are guaranteed 10 years.
Unless proven otherwise, it shall be presumed that if not shown within six months of delivery that the product was ne when
delivered.
There is a parts warranty of two years from the date of delivery of the appliance, apart from the aluminium frame which is
guaranteed for ten years.
This warranty applies, only and exclusively, to equipment sold and installed in Ireland and the United Kingdom. Repairs will be
carried out in the workshops of ATC or its nominated agent.
The material replaced in warranty becomes property of ATC.
Should any item be replaced under warranty, the only warranty on the replaced item is the remainder of the original
warranty.
SCOPE OF WARRANTY
Unless there are event(s) or object(s) that prove to the opposite, it will be assumed that the products acquired are suitable and
good for the purpose that it is purchased for and that always happens under the following conditions:
- The guaranteed unit shall correspond to the manufacturer intended exclusively for Ireland and the United Kingdom and
should be installed in Ireland and the United Kingdom.
- The spare parts which are necessary to replaced, will be determined by our qualied service and in all cases, shall be original
products from the manufacturer.
- The warranty is valid provided that normal maintenance operations described above in the technical instructions provided
with the equipment have been carried out.
- The consumer must inform ATC of the lack of conformity of the goods, in a period of less than two months since they learned
of it.
The warranty does not cover incidents caused by:
- The power supply of insucient capacity or equipment used with generators or any other system that is not a stable power
supply.
- Products whose repairs have not been conducted by ATC qualied service personnel or their authorized agents.
- Corrosion, deformation, etc., caused by improper storage or installation.
- Handling of the product by other personnel not employed by ATC during the warranty period.
- Installation not in accordance with the instructions provided in the equipment.
- Installation of equipment by unqualied personnel.
- Defects in electrical, hydraulic facilities, or by lack of ow, etc.
- Defects caused by improper treatment.
- Anomalies caused by atmospheric agents (ice, lightning, ooding, etc.) as well as erratic current or voltages.
- Improper maintenance, neglect or misuse.
- Damages caused to premises caused by lack of cleaning of the radiator (e.g. black streaks on walls).
Transport damages must be claimed by the user directly from the carrier.
VERY IMPORTANT: Radiators must be correctly sized for each room they are to heat. There is sizing information
available on the website www.atc.ie. Draughty and badly insulated rooms will cause the radiator to use more power to
reach the set temperature. Undersized radiators may not reach the set temperature and are costly to run.
To claim on the warranty here recognized, it will be required that the appliance is used as intended for household and commercial use only. Also, it will be necessary to deliver the radiator to the technical personnel of ATC at their premises or the
premises of their nominated agent. A clear and legible copy of the invoice or receipt for the radiator together with the delivery
slip must be supplied.
This warrranty is in addition to any satutory rights.
www.atc.ie www.atcelec.co.uk IE Tel.: +353 1 467 8302 - UK Tel.: +44 0203 564 9164 MADE IN SPAIN
14. CORRECT DISPOSAL OF THIS PRODUCT
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with
separate collection systems)
This marking shown on the product or its literature, indicates that it must not be disposed of with
other household wastes at the end of its working life.
To prevent possible harm to the environment or human health from uncontrolled waste disposal,
please separate this from other types of wastes and recycle it responsibly to promote the sustainable
reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local
government oce, for details of where and how they can take this item for environmentally safe
recycling.
Business users should contact their supplier and check the terms and conditions of the purchase
contract. This product must not be mixed with other commercial wastes for disposal.
ATC Electrical and Mechanical
ATC House
Broomhill Drive
D24 EF99, Tallaght, IRELAND
www.atc.ie www.atcelec.co.uk
MADE IN SPAIN
A73023520 - 2022-03