ATC Electrical & Mechanical W10-U, W15-U, W5-U Installation Instructions

ATC House, Broomhill Drive, Tallaght, D24 EF99, Ireland
5 Litre heater
IE: 01 4678301, UK:0203 564 9164, Email sales@atc.ie
ATC Electrical & Mechanical,
ATC PACIFIC WATER HEATING INSTALLATION AND OPERATION MANUAL
W5-u 5 Litre Undersink water heater W10-u 10 Litre Undersink water heater W15-u 15 Litre Undersink water heater
10 and 15 Litre heaters
-1-
ATC House, Broomhill Drive, Tallaght, D24 EF99, Ireland
IE: 01 4678301, UK:0203 564 9164, Email sales@atc.ie
ATC Electrical & Mechanical,
IMPORTANT SAFETY INSTRUCTIONS-READ BEFOR USING THIS WATER HEATER
1. This water heater must be earthed.
2. Locate & install this water heater only in accordance with the provided installation instructions.
3. Use this water heater only for its intended use as described in this manual.
4. This water heater should be installed by a qualified installer.
5. Do not operate this water heater if it is not working properly or if it has been damaged or dropped.
6. This water heater should be serviced only by qualified service personnel.
7. Failure to examine and if necessary, replace the anode rod at least once a year could cause the tank to fail and leak and void the warranty.
8. Cable connection should be to a 13A double-pole Switched Spur.
9. This water heater is not suitable for hard water areas unless a suitable water softener is fitted. In areas of hard water, failure to fit a water softener will cause premature unit failure and is not covered under warranty.
THESE INSTRUCTIONS SHOULD BE KEPT FOR FUTURE REFERENCE
1 Cold water Inlet 5 Heating indicator (5ltr)
LED On/Off Switch (10 & 15Ltr)
2 Hot water Outlet 6 Outer cover 10 Sacricial Anode
3 Temperature adjustment 7 Electrical heating element 11 Cold water inlet
4 Cover Screw 8 High Level Thermal cutout
9 Thermal insulation
-2-
ATC House, Broomhill Drive, Tallaght, D24 EF99, Ireland
IE: 01 4678301, UK:0203 564 9164, Email sales@atc.ie
ATC Electrical & Mechanical,
TECHNICAL SPECIFICATIONS
Product Code W5-U W10-U W15-U
Capacity Litres 5 10 14
Gallons 1.1 2.2 3.3
Power Watts 2000 2500
Voltage Volts 220-240
Frequency Hertz 50-60
Maximum Pressure Bar 8
Safety valve Max. Pressure Bar 6
Minimum Operating Pressure Bar 1
Connection Type 1/2” Male BSP
Distance Between Connections mm Center to Center 100
Thermostat Type Capillary type
Thermostat Range °C Min - °C Max 30-80 35-75
External Switch No Yes
Heating Indicator LED Yes
Installation location Undersink, wall mounted or
standing on rubber feet
*
ERP Class B B
Heating Time (minutes) ΔT 35°C 7 13 15
ΔT 45°C 9 17 19
Dimensions Height 285 300 337
Width 240 340 364
Depth 240 330 354
IP Rating X4
Weight (kg) Empty 4.5 6.5 8
Full 9.5 16.5 23
* The ATC Pacific water heaters are supplied with Adhesive rubber pads to mount on the bottom of the heater to allow them to stand rather than be wall mounted.
NOTE: The installer should review the contents of this manual with the owner on com­pletion of the installation.
-3-
ATC House, Broomhill Drive, Tallaght, D24 EF99, Ireland
45
45
14
66
Concrete or Brick
Timber or Plaster
Hang the heater on the Bracket
IE: 01 4678301, UK:0203 564 9164, Email sales@atc.ie
ATC Electrical & Mechanical,
GENERAL WIRING DIAGRAM
HEATER MOUNTING INSTRUCTIONS
The water heater should be installed close to a water drainpipe so that excess water from the safety relief valve can drain away without harm; this drain pipe should always be kept free of obstruction. Fix the mounting bracket supplied with the heater to the wall; see below for dimensions of the holes required; always use screws that are suitable for the wall material and the weight of the heater otherwise the heater may pull the bracket o the wall. Hang the water heater on the bracket. Tug downwards on the heater to ensure that both “fingers “of the bracket are seated in the mounting slots.
The heater can also be stood on its base using the rubber feet provided for this purpose. Attach the four adhesive feet to the base of the heater before plumbing.
Confirm water piping orientation before wall mounting.
Note: If using the rubber feet, it is not neces­sary to use the wall bracket also. Should the installer wish to use the bracket as an additional xing method, conrm location of bracket with feet attached to heater prior to
-4-
installation.