ATC Toledo FPH1000T, Toledo FPH1500T, Toledo FPH2000T Installation, Operation & Maintenance Manual

FPH1000T FPH1500T FPH2000T
Toledo Panel Heater
INSTALLATION,
OPERATION &
MAINTENANCE MANUAL
Class I - IP 20
This Product is only suitable for well
insulated spaces or occasional use
1. IMPORTANT SAFETY INSTRUCTIONS
These instructions should be read carefully before installation and retained by the user. The booklet must be kept and delivered to the new user in case of change of ownership of the heater. The Manufacturer reserves the right to vary the features of the product without prior notice. The technical data are indicative only.
1. This heater is intended solely for the use it has been designed for, namely
space heating. The Manufacturer or Distributor is not responsible for any
damage that could happen due to improper use.
2. After unpacking, make sure that the heater is complete and shows no
signs of tampering or any visible damage. Should the unit be damaged please
return to the place of purchase.
3. Packing materials are potentially dangerous, keep away from children.
4. The heater can be used by children of at least 8 years of age (as well as by
persons with reduced physical, sensory or mental capabilities, or lack of
experience or required knowledge) provided that they are under supervision,
or after they have been instructed relating to the safe use and have
understood the potential dangers. Children should not play with the Heater.
5. Cleaning and maintenance must be performed by the user and not by
unsupervised children.
6. Children aged between 3 and 8 years of age shall not plugin, regulate, clean
the heater or perform maintenance. Children of less than 3 years should be
kept away unless continuously supervised.
7. Children aged from 3 years and less than 8 years shall only switch on/off the
heater provided that it has been placed in its intended normal operating
position and they have been given instruction concerning use of the heater
in a safe way and understand the hazards involved. Children should always be
supervised.
8. Before connecting the heater make sure that the voltage is the same as
indicated on the device rating label.
9. Do not use in presence of gas, inflammable or explosive liquids or substances
as defined in BS5345.
10. Some fundamental rules which apply to all electrical devices must be observed
when using the heater:
Do not touch the heater with wet hands.
Do not handle the heater when you have bare feet.
Do not let children play with the heater.
11. Avoid the use of extension cords with this product, extension cords may
overheat and there could be a risk of fire.
12. Do not make any modification to the Heater.
13. Keep connections dry.
14. If the power supply cord is damaged, do not use the heater until the cord has
been replaced. For power cord replacement, always contact an electrician in
order to avoid any risk of injury.
15. If the heater is not going to be used for a long period, disconnect it from the
power supply.
16. Always disconnect the heater before doing any maintenance
CAUTION - Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
2. ELECTRICAL INSTALLATION NOTES
The installation should always be carried out by a qualified electrician or
a competent person in accordance with the current electrical standards:
HD 384 CENELEC for Mainland Europe, IEC 60446 and BS 7671 for the
United Kingdom, IEC 60445(2010) & ET101:2008 for Ireland and IEC 60364-7-708 1988
Internationally. The energy supply to the heater must always be properly earthed. The
heater must be connected to the energy supply using the provided cable.
An overvoltage category III Combined Circuit breaker and Residual Current Device (RCD) with rated earth leakage operation not exceeding 30mA must be fitted upstream on the supply line. The circuit breaker must have a contact opening distance of at least 3 mm.
The heaters should always be used with the mounting feet provided
Under no circumstances turn the heater on if it is not mounted using the Feet
supplied or if the face of the heater is on any surface.
The heater must not be recessed in the ceiling. There must be enough space
around the top of the heater to ensure adequate ventilation.
A minimum air gap of at least 90 cm should always be allowed between the top
of the heater and a ceiling or roof.
A distance of at least 100 cm should always be left in front of the heaters to
ensure safety
The Heater must not be located either directly below, or in front of a socket-
outlet.
The heater must not be used in a bathroom.
Loading...
+ 5 hidden pages