1. PRODUCT NAME
DESIGN WALL™
2. MANUFACTURER
ATAS INTERNATIONAL, INC. Website: www.atas.com Email: info@atas.com Corporate Headquarters: Allentown, PA 18106 Phone: (610) 395-8445 Fax: (610) 395-9342 Western Facility: Mesa, AZ 85204 Phone: (480) 558-7210 Fax: (480) 558-7217 Southern Facility: Maryville, TN 37801 Phone: (800) 468-1441
3. PRODUCT DESCRIPTION
Basic Uses:
Design Wall consists of a 12” wide panel in two distinct proles. Panels may be used for wall applications, sots, fascia or equipment screens.
Composition & Materials:
Standard Oerings: Design Wall panels are roll­formed from .032, .040 and .050 Aluminum; 24 gauge Metallic Coated Steel; and 24 gauge 55% Al-Zn alloy Coated Steel with acrylic coating. Special Oerings: 20 and 22 gauge Metallic Coated Steel and 22 gauge 55% Al-Zn alloy Coated Steel with acrylic coating. Subject to minimum quantities and lead time.
Sizes:
Design Wall is a 12” wide panel in two distinct proles. DSF and DSH panels are 1 ¾” high; DWF and DWH panels are 1 ⁄” high. The “F” code indicates a at or ush panel and the “H” code indicates a “board” panel. The “board” panels have an upside of 6” that may be extended in 1” increments (subject to minimum orders). For every 1” change on the “board”, the lower part of the panel is decreased to give net 12” coverage (with a maximum ”board width of 11”). All panels have the same lock conguration and stiening ribs standard, specify without. The DS panel is used primarily where increased structural integrity of the panel is required. Panels of .032 aluminum can be lanced for ventilation. Panel lengths are cut to customer specications with a minimum of 3’-0”, maximum to transportation limitations and/or product and project design considerations.
Design Wall KYNAR 500® is a registered trademark of Arkema. HYLAR 5000® is a registered trademark of Solvay Solexis, Inc. © ATAS International, Inc. LRD0213 LAT845
TM
is a trademark of ATAS International, Inc.
Colors & Finishes:
A choice of 30 stock colors is available in a KYNAR 500® PVDF or HYLAR 5000® PVDF nish. (Request color chart or chips). An anodized nish is available in Clear or Dark Bronze. Texture may be smooth or embossed.
4. TECHNICAL DATA
KYNAR 500® PVDF or HYLAR 5000® PVDF based nishes tested by paint supplier for: Dry Film Thickness: ASTM D 1005, ASTM D 1400, ASTM D 4138 or ASTM D 5796 Specular Gloss: ASTM D 523 Pencil Hardness: ASTM D 3363 T-Bend Flexibility: ASTM D 4145 Mandrel Bend Flexibility: ASTM D 522 Impact Resistance: ASTM D 2794 Adhesion: ASTM D 3359 Water Immersion Resistance: ASTM D 870 Abrasion Resistance: ASTM D 968 Acid Resistance: ASTM D 1308 Acid Rain Resistance (Kesternich): ASTM G 87 or DIN 50018 Salt Spray: ASTM B 117 Cyclic Salt Spray: ASTM D 5894 and ASTM D 5487 Humidity Resistance: ASTM D 2247 Accelerated Weathering: ASTM D 822 and ASTM G 155, ASTM G 151 or ASTM G 153 Color Retention, Florida Exposure: ASTM D 2244 Chalking Resistance: ASTM D 4214 Cleveland Condensing Cabinet: ASTM D 4585 Cure Test, MEK Resistance: ASTM D 5402 Alkali Resistance, Sodium Hydroxide: ASTM D 1308, Procedure 7.2 Flame Spread Rating: ASTM E 84 Organic coatings meet requirements of AAMA 2605 when applied to aluminum. Panel testing/ratings: Galvanized Steel: ASTM A 653 55% Al-Zn alloy Coated Steel: ASTM A 792 Aluminum: ASTM B 209 Copper: ASTM B 370 Coil Coating: ASTM A 755 Field Tested and Approved. Load Tables available upon request.
5. INSTALLATION
Design Wall may be installed horizontally or vertically. Installation manuals and hands-on training via seminars are available through ATAS. Visit www.atas.com for more information.
6. AVAILABILITY & COST
Availability:
Design Wall panels are available through
ATAS product distributors. A complete line of related components and trim accessories is available to complete the wall system. In addition, a complete line of rainware and perimeter roof edge trims can be supplied by ATAS to complement the wall system. Flat sheet and/or coil stock is available in matching color for fabrication of related components by the installing contractor.
Cost:
Contact ATAS product distributors for current pricing.
7. WARRANTY
Products coated with a uoropolymer, KYNAR 500® PVDF or HYLAR 5000® PVDF nish carry a limited warranty against chalking and fading.
8. MAINTENANCE
Design Wall panels are virtually maintenance free. Surface residue may be easily removed by conventional cleaning methods. For painted products, minor scratches should be touched up with a matching paint, available from ATAS International, Inc.
9. TECHNICAL SERVICES
Complete technical information and literature are available at www.atas.com. ATAS will assist with design ideas and shop drawings.