ATAS ATA-Guard User Manual

ATAS INTERNATIONAL, INC.
SPECIFICATION DATA SHEET
1. PRODUCT NAME
ATA-Guard™ Synthetic Roong Underlayment
2. SUPPLIER
ATAS INTERNATIONAL, INC. website: www.atas.com email: info@atas.com Corporate Headquarters: Allentown, PA 18106 Phone: (610) 395-8445 Fax: (610) 395-9342 Western Facility: Mesa, AZ 85201 Phone: (480) 558-7210 Fax: (480) 558-7217 Southern Facility: Maryville, TN 37801 Phone: (800) 468-1441
3. PRODUCT DESCRIPTION
Basic Uses:
ATA-GuardTM is a highly engineered, mechanically attached, coated woven synthetic roong underlayment for sloped roofs. It can be used under all types of primary roong materials and is approved as an alternative replacement for Type 15 or Type 30 asphalt roong felt. ATA-Guard is 5 times lighter and 25 times stronger than 30# asphalt.
Composition and Materials:
ATA-Guard is 100% asphalt free, reinforced underlayment. Advanced polymers are combined to produce a lm that is unaected by water and resistant to UV for up to 6 months.
Size:
ATA-Guard has a nominal thickness of 30 mils and is available in rolls 48” wide by 250’ long, a total area of 1000 sq. ft. Each roll weighs 48 pounds.
Color and Finish:
Polymers are combined to produce a gray color that is much cooler than traditional asphalt-based underlayments. The walking surface has a nodular texture that allows for steep slope walkability even in wet conditions.
4. TECHNICAL DATA
ASTM E 108 Class A Fire
TM
ATA-Guard KYNAR 500® is a registered trademark of Arkema. HYLAR 5000® is a registered trademark of Solvay Solexis, Inc. © 2011 ATAS International, Inc. LRD0711 LAT643
is a trademark of ATAS International, Inc
ASTM D 1970 Nail Sealability ASTM E 96-00 Permeability 0.05 perms ASTM D 4869 Water Transmission ASTM D 226 Tear Strength MD 55 lbs, CD 55 lbs ASTM D 751-95 Tensile Strength MD 178 lbs, CD 176 lbs Burst Strength 300 psi Elongation MD 20%, CD 20% ASTM D5261 Weight per Square 4.7 lbs ASTM D 1777 Minimum Thickness 30 mils Temperature Range -70°F to 212°F.
5. INSTALLATION
Recommended Application:
ATA-Guard must be installed above properly ventilated spaces (following local building code) as it is considered a vapor barrier. Installation manuals or hands-on training through seminars are available through ATAS. Visit www.atas.com for more information.
Application Methods:
ATA-Guard is an air, water and vapor barrier. It must be installed above properly ventilated spaces (follow ALL building codes applicable to your geographical region and structure type) as it is considered a vapor barrier (.05 perms). The use of a rosin paper slip-sheet is not required underneath metal roong systems. Protrusions from the deck area must be removed and decks shall have no voids, damaged or unsupported areas. The use of a straight edge cutting knives is recommended. ATA-Guard is laid out horizontally (parallel) to the eave with the printed side up, and with the 4” horizontal laps and 6” vertical laps. Follow the codes for low slope as dened as 2:12 to 4:12 and steep slope greater than 4:12 applications. ATA-Guard must be attached to the structural roof deck material using ⁄” head electro galvanized (EG) roong nails; tin tag caps & nails; screws with washers; plastic cap staples or plastic cap nails. Anchoring to be installed at a minimum as per surface markings, spaced 6” on center in the vertical and horizontal laps, and at 12” on center along the center of the roll in the eld as marked. If the application of ATA-Guard and the nal roong material occur on the same day, then the option to use every other printed anchoring placement is acceptable. All anchoring devices must be flush, 90 degrees to the roof deck, and tight with the underlayment surface and the structural roof
deck. For extended exposure (months) or high wind, double the lap widths as a minimum. Option: Fold the overlay laps forming a “J” channel configuration before nailing; using a compatible sealant between the laps, or using a peel and stick tape is highly recommended. For batten secured installations, use only adequate length nails or screws to secure battens to the structural roof deck material. It is recommended to use ⁄” head electro galvanized roong nails; plastic cap staples; plastic cap nails or screws with metal or plastic washers to secure ATA-Guard to prevent blow o until the batten system is installed. When using plastic cap and staples, staple leg should be a minimum ½” or longer. Do not install battens directly over any plastic caps. If this occurs, remove plastic cap staples or nails, patch the hole, then install cap outside batten eld and continue. Where seams and joints require sealant or adhesive, use a high quality, low solvent, Asbestos free, plastic roofing cement meeting ASTM D-4586 Type 1 (Asbestos free), Federal Spec SS-153 Type 1 (Asbestos free) such as Karnak, Henry, DAP, MB, Geocel or equivalent. Acceptable alternatives are butyl rubber, urethane, and EDPM based caulk or tape sealant. Depending on roof pitch and surface conditions, blocking may be required to support materials on the roof
6. AVAILABILITY AND COST
Availability:
ATA-Guard is available through ATAS product distributors.
Cost:
Contact ATAS product distributors for current pricing.
7. WARRANTY
ATA-Guard is covered by a fty (50) year limited warranty.
8. MAINTENANCE
None when installed in accordance with manufacturer’s recommendations.
9. TECHNICAL SERVICES
Complete technical information and literature are available from ATAS International, Inc. ATAS will assist with design ideas and shop drawings.
10. FILING SYSTEM
www.atas.com• Additional product information is available from the manufacturer upon request.