The machine may be connected to a hot water tap upto 60 °C.
For cleaner and dryer results however, it is advised to connect the machine to a
cold water tap
with extension 80 cm
va =1,3 m
v b=1,6 m
v c =1,4 m (3,6 m with extension set)
v d =1,2 m (3,4 m with extension set)
v e =1,6 m (3,6 m with extension set)
v f =1,2 m (3,2 m with extension set)
Water connection:
v The water connection is ¾”
v Minimal water pressure 0,5 bar (to be tested with a bucket, minimal 8 l/min)
v Maximum water pressure 10 bar
Warmwater recognition:
If during hot rinsing the temperature of the incoming water is higher than 45°C , the
temperature of the hot rinsing is increased to 72°C.
The heat exchanger is not being filled during the drying process.
Weight accessory panels
88001054
88001114
88007087
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 1
-
Aquasensor II
By means of the Aqua sensor it is decided whether or not the rinsing
water will be used for the next rinsing cycle.
The Aqua sensor II has two LED’s
v Red LED (measures turbidity)
v Green LED (measures soil remains)
Because of this, more soiling (like tea or
spinach) will be recognized.
The calibrating process uses water, reason not to calibrate every washing cycle.
During the first 3 washing cycles an extra 400 ml water is being used for
calibrating the Aqua sensor.
The calibrating process is repeated every 20th
washing cycle.
Receiver
Transmitters
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 2
-
Panel mounting ( new )
Integrated Fully integrated
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 3
-
Regenerating the water softener
Regeneration water
Flushing the softener
Hard water
Reg. Water
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 4
-
Filling with non-softened water.
Hard water
Soft water
Filling with softened water.
Hard water
Soft water
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 5
-
Load recognition
How it is determined whether or not water has to be added because of toppled
crockery.
Circulation pump
with tacho and sycasym control
Capacitor
Tachogenerator
Single phase AC motor
Tacho generator
Motor RPM is measured by means of a tacho generator.
Speed control is applied by means of electronic phase shifting.
v Load recognition
At the first wetting of the dishes, some water will stay behind, for instance in a
toppled dish or plate, so under circumstances the machine begins washing in
short supply of water.
If so, the pump may catch air, starting to run irregularly while making more noise.
The tacho generator recognizes this irregular running and extra water is supplied.
v At the first test 200 ml
v At the second test another 200 ml
v At the third test another 500 ml
Max. 900 ml of extra water supply is possible.
This means that not 2,8 l but 3,7 l of water is being used for washing.
PTC
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 6
-
Load recognition
Tacho recognizes shortage of
water because of irregular running.
After levelling the machine runs
quietly again
Motor RPM is measured by means of a tacho generator.
Speed control is applied by means of electronic phase shifting.
• Load recognition.
• RPM reduction d uring soft programs
• RPM reduction at rinsing change (shifting from upper basket washing to
lower basket washing )
•Different RPM for upper basket washing relative to lower basket washing
( 2200 / 2800 1/min)
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 7
-
Inlet valve
Outlet valve
F1
After
this, water
supplement
depends on
the
tacho
generator
(load recognition
) Circulation
Filling water
pump
If tap is closed:
In case level F1 is not reached after 3½ minutes, the control will stay in this
position. On the display the message appears: ´Check water supply´.
As soon as the tap is opened, the machine will continue running the program .
In case of clogged level chamber or faulty F1
In case of faulty F1 the filling process develops as
follows
v Machine continues filling
v Safety level will be reached
v Machine idles
v After some time the inlet valve will be closed and
the programme continues
This symbol on the inner door indicates that the machine is equipped
with a heat exchanger.
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 8
-
B A
Soap dispenser
Function:
At the first pulse the soap dispenser is opened. Lever A is put in the position which
facilitates – at the next pulses – the operation of lever B (each pulse lasting 20 seconds).
Depending on the chosen amount of
rinsing aid, this lever B is being
activated (2 ml per pulse )
Setting Pulses
0 0
1 2
2 3
3 4
4 5
5 6
6 7
Tank total 120 ml
Top control. Only for ST and TT
Sufficient
The soap dispensers in the other models are controlled by means of an actuator. This
actuator is being controlled for two minutes continuously . That is why these dispensers
are not interchangeable !
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
- 9
-
Empty
Operation
Touch control with IR technology
Lightconductor
IR -receiver
IR-transmitter-LED
Common problems with IR sensors
Too much distance between sensor and panel
Sensor comes loose
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
10 -
Sensors react after ~1 seconds
Stand
-
by button
Option
-
/ store button
Push touch control button at least 1 second .
Main switch after ~2 seconds
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
11 -
Selector buttons
Start button
A control soap dispenser B
water
renewal
VA(9)6211TT
C regeneration valve D Aquamix valve
F inlet valve G outlet valve
H circulation pump I Opto sensor
J drainage valve K sicasym relay
L+M mains relay N heating relay
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
12 -
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
13 -
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
14 -
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
15 -
Product information
VA 3.. VA9011XT..ZT..VA..VA(9)6211Q..R..S..T
MPr 28112005
16 -
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.