ASUS R5230-SL-1GD3-L User Manual

Page 1
For the following equipment
Ref. No.: ACWE-RC140159 (ACWE-G1103016R2)
Applicant :
ASUSTeK COMPUTER INC.
Manufacturer #1 : ECS Golden Elite Group CO.,LTD PCBA. Manufacturer #2 : MainTek Computer (Suzhou) Co., Ltd.
Manufacturer #3 : Nissho Technology (Suzhou) Co., Ltd. Manufacturer #4 : Danriver Technology (Guangzhou) Inc. Product :
VGA Card (1) EAH5450 SILENT (2) EAH5450 SILENT/DI/512MD3
Model Number :
(3) HD5450-Y(C093PI) (4) EAH5450 SILENT/Y(C093PI) (5) HD6450-Y(C093PI) (6) EAH6450 SILENT/Y(C093PI) (7) R5230-SL-1GD3-L
Brand :
ASUS
We, AUDIX Technology (Wujiang) Co., Ltd. EMC Dept. hereby certify that the above products has been tested by us with the listed standards and found in compliance with the council EMC directive 2004/108/EC. It is possible to use CE marking to demonstrate the compliance with this EMC Directive. The test data & results are issued on the EMC test report No. ACWE-E1103008B.
Emission: EN 55022:2010+AC:2011 and AS/NZS CISPR22:2009+A1: 2010
EN 61000-3-2:2006+A2:2009 and EN 61000-3-3:2013
Immunity: EN 55024:2010
( IEC 61000-4-2:2008, IEC 61000-4-3:2006+A2:2010,
IEC 61000-4-4:2012, IEC 61000-4-5:2014,
IEC 61000-4-6:2013, IEC 61000-4-8:2009, IEC 61000-4-11:2004)
Oct.28, 2014
Ken Lu/ Assistant General Manager AUDIX Technology (Wujiang) Co., Ltd. EMC Dept.
The statement is based on a single evaluation of one sample of the above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab logo.
Page 2
EMC TEST REPORT
For
ASUSTeK COMPUTER INC.
VGA Card
Model No.: (1) EAH5450 SILENT (2) EAH5450 SILENT/DI/512MD3
(3) HD5450-Y(C093PI) (4) EAH5450 SILENT/Y(C093PI)
(5) HD6450-Y(C093PI) (6) EAH6450 SILENT/Y(C093PI)
(7) R5230-SL-1GD3-L
Brand: ASUS
Prepared for
ASUSTeK COMPUTER INC.
4F, No.150, Li-Te Rd., Peitou, Taipei 112, Taiwan
Prepared by
Audix Technology (Wujiang) Co., Ltd. EMC Dept.
No.1289 Jiangxing East Road, the Eastern Part of Wujiang Economic Development Zone
Jiangsu China 215200
Tel.: +86-512-63403993
Fax : +86-512-63403339
Report Number Date of Test Date of Report
ACWE-E1103008B
Mar.11~13, 2014
Oct.28, 2014
Page 1 of 8
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B
Page 3
Page 2 of 8
TABLE OF CONTENTS
Description Page
TEST REPORT VERIFICATION.......................................................................................................4
1 DESCRIPTION OF VERSION ...................................................................................................4
2 SUMMARY OF STANDARDS AND RESULTS.......................................................................5
2.1 Description of Standards and Results..................................................................................................5
2.2 Description of Performance Criteria....................................................................................................6
3 GENERAL INFORMATION ......................................................................................................7
3.1 Description of Device (EUT) ..............................................................................................................7
3.2 Description of Test Facility ................................................................................................................. 8
3.3 Measurement Uncertainty ...................................................................................................................8
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B
Page 4
Page 5
1 DESCRIPTION OF VERSION
Edition No. Date of Rev. Summary Report No.
0 Mar.23, 2011 Original Report. ACWE-E1103008
1.Add four models (1) HD5450-Y(C093PI)
Rev. A Mar.14, 2014
(2) EAH5450 SILENT/Y(C093PI) (3) HD6450-Y(C093PI) (4) EAH6450 SILENT/Y(C093PI)
2.Add a new GPU:CAICOS PRO
ACWE- E1103008A
Page 4 of 8
Rev. B Oct.28, 2014
1. Add a model: R5230-SL-1GD3-L.
2. Change the standards to the latest.
ACWE- E1103008B
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B
Page 6
2 SUMMARY OF STANDARDS AND RESULTS
2.1 Description of Standards and Results
The EUT has been tested according to the applicable standards and test results are referred as below.
EMISSION
Page 5 of 8
Description of Test
Item
Conducted disturbance
at main terminal
Conducted common mode disturbance at
telecommunication port
Radiated disturbance
Harmonic current
emissions
Voltage fluctuations &
flicker
Description of Test
Item
Standard Limits Results Remark
EN 55022:2010+
AC:2011 and AS/NZS
CISPR22:2009+A1:2010
EN 55022:2010+
AC:2011 and AS/NZS
CISPR22:2009+A1:2010
EN 55022:2010+
AC:2011 and AS/NZS
CISPR22:2009+A1:2010
EN 61000-3-2: 2006+A2:2009
EN 61000-3-3:2013
IMMUNITY (EN55024:2010)
Basic Standard
Class B PASS
Class B Note
Class B PASS
Class D PASS
Pst=1
dc(%)=3.3%
dMax.(%)=4%
d(t)>3.3%=500ms
Performance
Criteria
PASS
Results
Minimum passing
margin is 17.89 dB
at 5.44MHz
---
Minimum passing
margin is 6.06dB
at 526.64MHz
Meets the Class D
requirement
Meets the
requirement
Observation
Criteria
Electrostatic discharge
(ESD)
Radio-frequency,
Continuous radiated
disturbance
Electrical fast transient
(EFT)
Surge
Radio-frequency,
Continuous conducted
disturbance
Power frequency
magnetic field
Voltage dips, >95%
reduction
Voltage dips, 30%
reduction
Voltage interruptions
IEC 61000-4-2:2008 B PASS A
IEC 61000-4-3:
2006+A2:2010
A PASS A
IEC 61000-4-4:2012 B PASS A
IEC 61000-4-5:2014 B PASS A
IEC 61000-4-6:2013 A PASS A
IEC 61000-4-8:2009 A PASS A
B PASS A
IEC 61000-4-11:2004
C PASS A
C PASS C
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B
Page 7
Page 6 of 8
Note: Due to the product doesn’t have telecommunication port, so according to the section 6.3 of the
standard, it doesn’t need measuring the telecommunication port.
2.2 Description of Performance Criteria
General Performance Criteria
Examples of functions defined by the manufacturer to be evaluated during testing include, but are not limited to, the following:
essential operational modes and states; tests of all peripheral access (hard disks, floppy disks, printers, keyboard, mouse, etc.); quality of software execution; quality of data display and transmission;
quality of speech transmission.
2.2.1 Performance criterion A
The equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a performance level specified by the manufacture when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be deriver from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended.
2.2.2 Performance criterion B
After the test, the equipment shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacture, when the equipment is used as intended. The performance level may be replaced by a permissible loss of performance.
During the test, degradation of performance is allowed. However, no change of operation state or stored data is allowed to persist after the test.
If the minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then either of these may be deriver from the product description and documentation, and by what the user may reasonably expect from the equipment if used as intended.
2.2.3 Performance criterion C
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls by the user in accordance with the manufacture’s instructions.
Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be loss.
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B
Page 8
3 GENERAL INFORMATION
3.1 Description of Device (EUT)
Page 7 of 8
Product
Model Number
: :
VGA Card
(1) EAH5450 SILENT (2) EAH5450 SILENT/DI/512MD3 (3) HD5450-Y(C093PI) (Y=0-999999999999999,
a-zzzzzzzzzzzzzzz, A-ZZZZZZZZZZZZZZZ,“/”,“-”,
SPACE KEY) (4) EAH5450 SILENT/Y(C093PI) (Y=0-999999999999999,a-zzzzzzzzzzzzzzz,
A-ZZZZZZZZZZZZZZZ,“/",“-",SPACE KEY)
(5) HD6450-Y(C093PI) (Y=0-999999999999999,
a-zzzzzzzzzzzzzzz, A-ZZZZZZZZZZZZZZZ,“/”,“-”,
SPACE KEY) (6) EAH6450 SILENT/Y(C093PI) (Y=0-999999999999999,a-zzzzzzzzzzzzzzz,
A-ZZZZZZZZZZZZZZZ,“/”,“-”,SPACE KEY)
(7) R5230-SL-1GD3-L
Brand
Applicant
: :
ASUS
ASUSTeK COMPUTER INC. 4F, No.150, Li-Te Rd., Peitou, Taipei 112, Taiwan
Manufacturer#1 ECS Golden Elite Group Co., Ltd.
No.1,Nan-Huan Road, ShaJing, BaoAn, ShenZhen, China
Manufacturer#2
MainTek Computer (Suzhou) Co., Ltd. No.233 Jinfeng Road Suzhou New District, Jiangsu Province P.R.C.
Manufacturer#3
Nissho Technology (Suzhou) Co., Ltd. No.255 Huajin Rd. Tong’an Town Suzhou New District, Jiangsu Province P.R.C.
Manufacturer#4
Danriver Technology (Guangzhou) Inc. No.16, Baoying Dadao, Guangzhou Free Trade Zone, Guangdong, P.R. China
Date of Receipt of Sample
Date of Test
: :
Mar.05, 2014
Mar.11~13, 2014
Remark for Rev. B:
1. This report is based on the version ACWE-E1103008 & ACWE-E1103008A.
2. The difference between the additional model and the model “EAH6450 SILENT/Y(C093PI)” is just for different marketing, and the test results of EMC won’t be affected according to test lab. judged. All results are deemed to compliance with requirement of the standard. All test data could be referred to the report of ACWE-E1103008 & ACWE-E1103008A.
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B
Page 9
3.2 Description of Test Facility
Page 8 of 8
Name of Firm
Site Location
Test Facilities
NVLAP Lab Code
3.3 Measurement Uncertainty
Test Item Frequency Range Uncertainty
Audix Technology (Wujiang) Co., Ltd. EMC Dept.
No. 1289 Jiangxing East Road, the Eastern Part of Wujiang Economic Development Zone Jiangsu China 215200
No.1 10m semi-anechoic chamber
No. 1 conducted shielding enclosure The Complex Immunity Test Room RS&CS Test Room
200786-0 (NVLAP is a NATA accredited body under Mutual Recognition Agreement) Valid until on Sep.30, 2015
No. 1 Conducted Shielding Enclosure
Conducted Disturbance Measurement 150kHz~30MHz
±2.48dB
At 10m Semi-Anechoic Chamber
± 3.35dB (Horizontal) Radiated Disturbance Measurement
± 3.32dB (Vertical)
± 4.69dB
(Distance: 10m)
Radiated Disturbance Measurement
(Distance: 3m)
RemarkUncertainty = ku
(y)
c
30MHz~1000MHz
1000MHz~6000MHz
Audix Technology (Wujiang) Co., Ltd. EMC Dept. Report No.: ACWE-E1103008B