AstroStart XRT, BBK, BBU, BBW, BBF Installation Manual

PATENT NUMBERS
CAN 1.130.426
USA: 4.345.554 - 5.614.883
5.617.819 - 5.673.017
All rights reserved © Astroflex Electronics 2007 August 2007 IBRSS5224
INSTALLATION MANUAL
XRT - BBK - BBF - BBU - BBW
CONTROL MODULES
FOR ALL
GAS, DIESEL
AND HYBRID
POWERED VEHICLES
(Instructions en français au verso)
REMOTE CONTROL
ENGINE STARTER
THIS PRODUCT MUST BE INSTALLED
BY A QUALIFIED INSTALLER.
When this product is installed in a manual transmission vehicle,
the installation must be done with a manual interface
(not included - No. RS-MI).
IMPORTANT NOTICE
TO INSTALLERS!
The control module included in this kit must be interfaced according to the
type of vehicle in which it is installed. The control module won’t, IN ANY
WAY, monitor the position of the gearshift lever during a remote start.
It is factory set to "Manual Transmission" mode.
See Stage 1 - Level 16 on page 22 for programming options.
For vehicles equipped with a MANUAL TRANSMISSION
you must pay
special attention to the instructions identified with the following pictogram and follow the corresponding instructions.
When this product is installed in a manual transmission vehicle,
the installation must be done safely
using a manual interface
(not included – part no. RS-MI). This module is designed to force the user to ensure that the gearshift lever is in neutral and that the parking brake is activated for the system to proceed to ready mode for remote start.
Make sure you deliver the User Manual to the customer
Make sure you post the two warning labels in the appropriate locations:
the smaller one must be visible in the driver's side window; the other must be placed near the hood release lever.
Make sure you hang the "For your safety" card on the rear-view mirror.
Also make sure all verifications and testing (for automatic or manual transmission vehicle) is done before and after the installation is done.
1
Table of contents
VERIFICATIONS AND TESTING TO BE DONE BEFORE THE INSTALLATION........................................................ 2
QUICK GUIDE FOR SKILLED INSTALLERS ................................................................................................................ 3
IMPORTANT NOTE TO BE READ AT THE INSTALLATION..............................................................................................................................8
CONTROL MODULE PROGRAMMING .......................................................................................................................................................8
DETAILED FEATURES................................................................................................................................................... 9
P1: ALARM (OPTIONNAL)....................................................................................................................................................................9
P1-1: RED/WHITE: SIREN OUTPUT (+)....................................................................................................................................9
P1-2: GREY: TRUNK OUTPUT (-).............................................................................................................................................9
P1-3: BLUE: DOME LIGHT OUTPUT (-)....................................................................................................................................9
P1-5: PINK: ARMED OUTPUT (-)..............................................................................................................................................9
P1-6: WHITE: DOORS / HORN (-) & P1-7: PURPLE: DOORS / HORN (+) ...............................................................................9
P1-8: YELLOW: ANTI-LOCKING .............................................................................................................................................10
P2: INPUT/OUTPUT ...........................................................................................................................................................................10
P2-1 & 2: RED..........................................................................................................................................................................10
P2-3: BLACK/RED: HOOD INPUT..........................................................................................................................................10
P2-4: WHITE/GREEN: POSITIVE BRAKE SWITCH INPUT....................................................................................................10
P2-5: ORANGE/WHITE: PARKING LIGHT / GLOW PLUG DETECTION INPUT (±)..............................................................10
P2-6: DARK GREEN: NEGATIVE OUT WHEN RUNNING.....................................................................................................11
P2-7: ORANGE: ANTI-THEFT OUTPUT.................................................................................................................................11
P2-8: LIGHT GREEN: HORN OUTPUT ..................................................................................................................................11
P2-9: RED/WHITE: +12V OUTPUT..........................................................................................................................................11
P2-10: BLACK/GREEN: TACHOMETER INPUT.....................................................................................................................11
P2-11: BLACK: GROUND INPUT ...........................................................................................................................................11
P2-13 TO P2-16: PROGRAMMABLE OUTPUT #1 TO #4 .......................................................................................................12
P3: POWER DOOR LOCKS .................................................................................................................................................................12
P4: MAIN HARNESS ..........................................................................................................................................................................12
P4-1: RED/BLACK: POWER INPUT.......................................................................................................................................12
P4-2: YELLOW: ACCESSORY OUTPUT................................................................................................................................12
P4-3: GREEN: PARKING LIGHT OUTPUT.............................................................................................................................13
P4-4: ORANGE: IGNITION OUTPUT......................................................................................................................................13
P4-5: DARK BLUE: STARTER OUTPUT ................................................................................................................................13
P4-6: LIGHT BLUE: STARTER CUT INPUT...........................................................................................................................13
P4-7: RED: POWER INPUT....................................................................................................................................................13
P5: PROGRAMMABLE RELAY .............................................................................................................................................................13
P6 - P16: CONNECTORS FOR PLUG-IN ACCESSORIES ...........................................................................................................................14
P6: SHOCK SENSOR (SUPPLIED WITH ALARM KIT 310-120-503) ......................................................................................14
P7: OTHER SENSOR (SUPPLIED WITH ALARM KIT 310-120-503).......................................................................................14
P9: LED (STATUS) ..................................................................................................................................................................14
P10: TIMER CONTROL...........................................................................................................................................................14
P11: VALET SWITCH ..............................................................................................................................................................15
P12: MANUAL INTERFACE.....................................................................................................................................................15
P13: MAIN SWITCH.................................................................................................................................................................15
P15: RECEIVER CONNECTOR...............................................................................................................................................15
P16: IM – OM – IOM ACCESSORIES CONNECTOR..............................................................................................................15
DETAILED PROGRAMMING OF THE CONTROL MODULE......................................................................................16
PROGRAMMING PROCEDURE ..............................................................................................................................................................16
STAGES PROGRAMMING......................................................................................................................................................16
LEVELS PROGRAMMING....................................................................................................................................................... 16
PROGRAMMING TABLES ....................................................................................................................................................................17
DIAGNOSTIC CODES................................................................................................................................................... 24
VERIFICATION OF INSTALLATION ............................................................................................................................ 25
POST-INSTALLATION AND SECURITY TESTS......................................................................................................... 26
CODE LEARNING OF TRANSMITTER (S).................................................................................................................. 27
WITH THE DIP SWITCHES ...................................................................................................................................................................27
W
ITH THE IGNITION KEY .....................................................................................................................................................................27
2
VERIFICATIONS AND TESTING TO BE DONE
BEFORE THE INSTALLATION
To ensure that the installation and the use of this product are safe,
you must
follow the instructions in this manual.
Please pay special attention to the following points.
AUTOMATIC TRANSMISSION VEHICLE
Ensure that the vehicle cannot be remote started when in gear. Also ensure that the gearshift lever cannot
be moved out of the "Park" position without first applying the brakes.
If it is possible to crank the engine while the gearshift lever is in gear, or if you can move the gearshift lever out of "Park" position without pressing on the brakes, contact our Technical Assistance Department at 1-800-461-8223. A technical advisor will help you with an appropriate and safe solution based on the make and
model of the vehicle on which you are working.
Once the installation is completed, you must check ALL safety devices described in the "POST­INSTALLATION AND SECURITY TESTS" on page 26 of this guide.
MANUAL TRANSMISSION VEHICLE
Make sure you have in hand a “manual interface module” part no. RS-MI (not included) specially made to safely install the remote starter in a manual transmission vehicle.
Make sure that all door pin switches work and that the parking brake is operational (i.e. it can
immobilize the vehicle). These security features must be operational before the installation of the remote starter.
Make sure it is impossible to access the gearshift lever without opening a door or the
hatchback.
If the gearshift lever can be accessed without opening a door (i.e. convertibles) or if
opening any one door does not break the safety sequence, we strongly recommend adding a motion detector (microwave) to prevent a start if any activity is detected near the gearshift lever. See details on the manual interface
instructions.
Once the installation is completed, you must check ALL safety devices described in the "POST-INSTALLATION AND SECURITY TESTS" on page 26 of this guide. Make sure the opening of each door and/or of the hatchback (one at a time) breaks the safety sequence that normally allows the system to initiate a remote start sequence.
3
Quick Guide for Skilled Installers
This section of the installation manual is intended for experienced installers of remote starter and mobile security products. Only the most frequently needed information are included in the following few pages. It has been laid out to quickly access connection and operational details to maximize your installation performance.
If, for any reason, additional information is required on a specific wire, refer to the “Detailed Description” section on page 9.
Note concerning vehicles equipped with an immobilization system
When the remote starter is installed on a vehicle equipped with a transponder type immobilization system, it is preferable to complete the installation of the control module and to test it before proceeding with the connection of the interface that neutralizes the vehicle's immobilization system (Starter Kill). See details in “Step 2: Full Start Test” on page 25
Each wire that provides a (-)
output can supply only one
single standard Bosch style automotive relay.
DESCRIPTION OF CONNECTORS
P1 - Alarm Inputs/Outputs (optional) P2 - Start Inputs/Outputs P3 - Locking/Unlocking relays P4 - Power Inputs/Outputs P5 - Programmable function relay P6 - Shock sensor P7 - Other sensor P9 - LED (Status) - Alarm, Antitheft and
Security sequence status LED P10 - Programmable timer P11 - Valet switch P12 - Manual Interface P13 - Main switch P15 - Receiver P16 - IM / OM Interfaces
Please note,
Yellow - accessory (YEL) and
Green – Parking Light (GRN) wire
can be program for different usage.
(See Stage 2 - Level 1 & 2
of the programming section)
FUTURE UTILIT
Y
FUTURE USE
USAGE FUTUR
4
DESCRIPTION OF CONNECTORS
The following charts show the purpose of each wire on each connector and list the pin position, color code and give a brief description of each.
Whenever you need further explanations on a wire or need to access the virtually unlimited programming flexibility of this AstroStart product, a reference to the detailed installation instructions found later in the manual will allow you to understand all of the connection and programming options available.
The last chart lists the connectors for the plug-in accessories.
P1 CONNECTOR (Optional)
PIN COLOR DESCRIPTION PURPOSE
1
Red/White
Siren Output
(+) 3amp max
Connect this wire to the Red wire of the Siren. See details on page 9.
2
Grey
Trunk Output
(-) 150ma max
Connect this wire to the circuit that feeds the trunk release mechanism. See details on page 9.
3
Blue
Dome light
Output
(-) 150ma max
Connect this wire to the circuit that feeds light in passenger compartment. See details on page 9. The programming options for this wire are at Stage 1 – Level 4 on page 18 and at Stage 2 – Level 3 on page 23.
4
- - No connection.
5
Pink
Ground when
armed Output
(-) 150ma max
Connect this wire to any device that needs to be neutralized or activated in conjunction with the integrated alarm system. See details on page 9.
6
White Door Input (-)
7
Purple Door Input (+)
Connect the White wire to the Negative side and the Purple wire to the Positive side of the dome light or any light of passenger compartment. These wires are used to monitor intrusion through the doors. In Alarm Link mode, they are used to monitor the horn chirps from the OEM alarm.
Both (-) and (+) connections are required.
See details on
pag
e 9.
8
Yellow
Key detection
Input (-)
Connected to “key reminder” circuit on steering column, this input prevents locking of the doors during automatic rearming of the alarm if key is in the ignition. Only required if semi-passive or passive arming is selected at Stage 1 - Level 14 or when “Rearming OEM security system” is enabled in Stage 1 - Level 4. See details on page 10.
P2 CONNECTOR
PIN COLOR DESCRIPTION PURPOSE
1-2
Red - Not use - Do not tap in or cut!
3
Black/
Red
Hood pin input
N.O. or N.C.
Connect this wire to the provided hood switch. Default setting: Normally closed when hood is opened. See Stage 1 – Level 3 on page 18 for programming options. See page 10 for more details on the input.
SAFETY CIRCUIT - must be connected!
4
White/ Green
Brake Input
(+)
Connect this wire to the brake light circuit of the vehicle.
SAFETY CIRCUIT - must be connected!
See page 10 for more details on the input.
5
Orange/
White
Parking Light
supervision
Input (±)
-
Glow Plug
supervision
Input (±)
If hookup for Parking light supervision, connect this wire to the Parking Light circuit of the vehicle. That will allow the remote starter to detect the lights staying ON when the vehicle is parked. If hookup for Glow Plug supervision, connect this wire to the circuit that changes polarity when the Glow Plugs are warm enough to start. This allows remote start to remain in stand-by mode until Glow plug has preheated (up to 30 sec.).
Default setting: Parking Light supervision, Positive (+)
The programming options for this wire are at Stage 1 – Level 3 on page 18. See page 10 for more details on the input.
5
P2 CONNECTOR
PIN COLOR DESCRIPTION PURPOSE
6
Dark Green
Ground when running
Output (-) 150ma max
Connect this wire to a circuit that requires a ground during runtime. Usually a transponder bypass interface. See page 11 for more details about this output.
7
Orange
Anti-theft Output
(-) 150ma max
Connect this wire to an external starter-cut device or an extra anti-theft status LED. See page 11 for more details about this output. Programming options are at Stage 1 – Level 4 on page 18.
8
Light Green
Horn Output
(-) 150ma max
Connect this wire to factory horn (-) circuit. See page 11 for more details about this output. Programming options are at Level 10 & 11 of the Stage 1, starting on page 20 and also at Stage 2 – Level 3 on page 23.
9
Red/
White
+12Volts Output
(+) 1amp max
Connect this wire to the positive side (coil) of additional relays.
Do NOT use for 2nd Ignition or 2nd Starter applications
See page 11 for more details about this output.
10
Black/
Green
Tachometer input
Connect this wire to a circuit in vehicle that provides a pulsed signal (tachometer signal/RPM) Default setting: 1 cyl. 800RPM. See page 11 for more details about this Input. Programming options are at Stage 1 – Level 2 on page 17.
11
Black Ground Input
Main Ground.
MUST be connected to left kick panel or firewall only.
12
N/C - Not used
13
Brown #1
14
White/
Blue
#2
15
White #3
16
Purple
Programmable Output
(-) 150ma max for each outputs
#4
Programmable outputs (-) used to control relays or low current circuit. Programming options are in Level 5 (#1), Level 6 (#2), Level 7 (#3) and in Level 8 (#4) of the Stage 1, starting on page 19. A wiring example is shown page 12.
Programmable outputs default setting:
Output no 1: Pulse Before Start (Disarm) Output no 2: Pulse After Shutdown (Rearm) Output no 3: Trunk Release. Output no 4: Dome Light. Note concerning connector P16 When an AstroStart interface is connected into P16, verify if it requires the programming of either one of the programmable outputs 1 & 2. If so, consider using programmable outputs 3 & 4 instead (P2-15 & P2-16).
P3 CONNECTOR
PIN COLOR DESCRIPTION BUILT-IN RELAY DESCRIPTION
1
Brown LOCK Common - 30
2
White/Brown LOCK N.C. - 87A
3
Brown/White LOCK N.O. - 87
4
Blue UNLOCK Common - 30
5
White/Blue UNLOCK N.C. - 87A
6
Blue/White UNLOCK N.O. - 87
Contacts
85 and 86 are polarized
through the module internal
circuits.
Each relay is controlled by the
function "Locking" or
"Unlocking".
REMARKS: Connector P3 provides access to two on-board Bosch type relays to interface all types of power door lock circuits. Refer to the AstroChart CD for door lock diagrams.
6
P4 CONNECTOR
PIN COLOR DESCRPTION PURPOSE
1
Red/Black Power Input
+12V power input, protected by a 30A fuse (F1) Supplies "Accessory-Yellow Wire" and the "Starter-Dark Blue Wire".
2
Yellow
Accessory
Output (+)
Feeds vehicle accessory circuit (Heater / AC circuit). This output can be program differently in Stage 2 – Level 1, page 23. See page 12 for more details about this output.
3
Green
Parking lights
Output (+)
Protected by a 10A fuse (F3), used to supply parking light circuit. This output can be program differently in Stage 2 – Level 3, page 23. See page 13 for more details about this output.
4
Orange
Ignition
Output (+)
Supply ignition circuit.
THIS CIRCUIT IS PART OF A SECURITY DEVICE; it must be
connected directly to vehicle's main
ignition circuit.
5
Dark Blue
Starter
Output (+)
Connects to vehicle "Starter" circuit. When the starter Kill option is used, connect this wire to the starter side of the starter motor circuit.
6
Light Blue
Starter Kill
(Starter-cut) Input
Connects to key side of the starter motor circuit. Allows starter circuit to be shut off when vehicle is remote started to prevent "grinding" the starter motor. Also provides anti-theft function. Anti-theft may be set to Active or Inactive in Stage 1 - level 4, page 18.
Anti-theft Default setting: Inactive.
7
Red Power Input
+12V power input, protected by a 30A fuse (F2) Supplies "Ignition - Orange Wire" and the "Parking Lights - Green Wire".
P5 CONNECTOR
PIN DESCRIPTION PURPOSE
1
COMMON - 30 Pin 30 of standard Bosch type relay
2
N.C. - 87a Pin 87A of standard Bosch type relay
3
N.O. - 87 Pin 87 of standard Bosch type relay
The default setting is for Active while running
(Stage 1 - Level 9 on page 20).
An appropriate fuse must
protect Power supply for this circuit
.
PLUG-IN ACCESSORIES CONNECTOR LIST
PLUG DESCRIPTION PURPOSE
P6
Shock Sensor Connector allowing a dual-stage shock sensor to be interfaced. See details on page 14.
P7
Additional Sensor
Connector allowing different types of sensors (single-stage) to be interfaced or to detect the opening of the trunk lid. See page 14 for more details about this Input.
P9
LED (status)
LED used to display the manual sequence status and alarm/antitheft status. See page 14 for more details about this connector.
P10
Dedicated
timer control
Negative trigger start input allowing a timer module to be interfaced. Requires a negative pulse (0.7 sec.) to initialize remote start procedure. See page 14 for more details about this Input.
P11
Valet switch
Valet switch connector. Used for Alarm/Antitheft valet mode or for the Pager option. See page 15 for more details about this connector.
P12
Manual Interface
Interface used to monitor doors and parking brake to validate safety sequence. See page 15 for more details about this connector.
P13
Disabling switch Switch used to turn the remote start functions off.
P15
Antenna / Receiver
Connector for the cable that plugs directly into the RF antenna / receiver module. See page 15 for more details about this connector.
P16
IM / OM / IOM
Interfaces
Connector used for AstroStart alarm/immobilizer interfacing module. (IM / OM / IOM) See further details packaged with the module and also page 15 for more details about this connector.
7
Default Setting
You may believe that a product as versatile as this one would be a programming nightmare. In most cases, you will not need to change a setting from the factory default programming
Consult the following charts to determine if the defaults work for the installation. If no changes are required, move to the testing phase of the installation on page 25. If, for any reason, changes to the default programming are required, please become familiar with the programming charts, beginning on page 17.
TOPIC DEFAULT FEATURES FOR STAGE 1 LEVEL
Transmitters
• No modification required unless additional remotes need to be learned. They are all factory programmed in User 1.
Level 1
Page 17
Tach/Engine • 1 cylinder - 800 RPM idle speed
Level 2
Page 17
Engine
configuration
• Circuit “P2-5” used for Parking light detection
• Parking Light or Glow Plugs circuit polarity is Positive (+)
• Ignition cuts off between crank cycles
• Hood switch closed contact when hood is open
Level 3
Page 18
Anti-theft
compatibility
• No accessory delay after start-up
• Rearming disabled
• Anti-theft disabled
Level 4
Page 18
Programmable
output 1
• Pulse before Start and with Unlock
Level 5
Page 19
Programmable
output 2
• Pulse after runtime and with Lock
Level 6
Page 19
Programmable
output 3
• Trunk opening
Level 7
Page 19
Programmable
output 4
• Dome light supervision
Level 8
Page 19
Programmable
Relay
• Active while running
Level 9
Page 20
Door lock
options
• 0.7 sec. pulse before ignition
• 0.7 sec. lock/unlock pulse
• Auto lock disabled
• Unlocking pulse = Single
• 2nd locking confirmation disabled
Level 10 Page 20
Utility outputs
• Utility output #1 and #2 = 0.7 second pulse
• Utility output #3 and #4 = 0.7 second pulse (no configuration)
• 30 seconds Panic/Alarm duration
Level 11 Page 21
Start cycle
options
• Over-revving supervision = Enabled
• Pulse before start on all Unlock outputs = Disabled
• Pulse after start on all Lock outputs = Disabled
• Runtime = 8 min. (Gas) / 16 min. (Diesel)
Level 12 Page 21
Sentinel Mode
• Sentinel mode temperature = -15º C (5º F)
• Sentinel mode runtime = 8 min. (Gasoline) / 16 min. (Diesel)
• Pulse before on Trunk command = Disabled
Level 13 Page 21
Alarm
• AstroStart Alarm = Disabled
• Chirp = Enabled
• Additional sensor = Other sensor
Level 14 Page 22
Remote options • Trunk command use for Trunk opening
Level 15 Page 22
Vehicle
configuration
• Manual Transmission car type
• Sequence initialized by 2 parking brake activations
Level 16 Page 22
Loading...