Astron Corporation SS-30M Data Sheet

Product Data Sheet
SS-30M (IEC 62368) Switching Power Supply
13.8 VDC, adjustable 30 Amps, peak current
Key Features
Connectors: [AC] IEC320-C14, [DC] 2 USB ports, 2 Anderson Power Pole ports, 1x2-Wire Terminals Rear panel port.
Digital Displays: Front Panel numeric LED, 1 DC Volt meter and 1 Amp meter, Illuminated ON/OFF switch.
Adjustable Voltage: 13.8 VDC ±1V, User manual control.
Technology: >82% efficiency switching, PFC, specific filtering for communication equipment all frequencies and HF.
EMI: Built-in EMI filter meets EMI Standards, EN55022/CISPR 22 (Class-B), FCC Part15 (Class-B), EN55024,
EN61000-3-2 (Class-D) , EN61000-3-3 (Harmonic) IEC61000-4-2,4,5 (EMS).
Protections Built-in: Current Limiting, Overvoltage protection, Fuse protection, Over Temperature shutdown.
Construction: Low profile, light weight and industrial metal case quality. Optional rack-mount front panel is available.
Safety: Certified to UL/CUL/EN/IEC 62368-1 standards.
Environmental: Certified to Energy Star and CEC standards where required, and RoHS (lead free) compliant.
Applications
Specifications
INPUT VOLTAGE:
120 to 230 VAC, 50/60Hz (Nominal Automatic Wide-Range selected)
OUTPUT VOLTAGES:
13.8 VDC (User manual adjustable ± 1 V)
2 USB ports: 5.2V, 1.5A per port
OUTPUT CURRENT
30A peak current - ICS Intermittent Communication Service (*)
TEMPERATURE
0 to +50ºC Operating, –20 to +85ºC Storage 120ºC max over-temperature setting
HUMIDITY
5 to 90% RH Operating, 5 to 95% RH Storage (Non-condensing)
Model No.
Voltage Input
Voltage Output
Continuous Amps
ICS (*) Current
SS-30M
Nominal Auto Selected
120 to 230 VAC
50/60Hz
User Manual Adjust ±1V
12.8 to 14.8 VDC
± 2%
25 A max
30 A peak max
Case Size (H x W x D)
Weight (Approx)
2 5/8 x 7 x 81/4 in
67.5 x 7 x 207.5 mm
4.3 lbs 2 kg
5/17//2021 SS-30M
MODEL SS-30M
WWW.ASTRONCORP.COM
9 Autry, Irvine, CA 92618 ● (949) 458-7277 ● Fax: (949) 458-0826
Communications Equipment - A Critical Power Solution
The SS-30M model supports currents up to 25A avg and peak up to 30A ICS (*) peak max. It is ideally suited for use with 12/13.8 VDC communications equipment. Switching technology >82% efficient meets individual power loading requirements. Included is special filter circuitry especially suited for all communications frequencies and HF.
Built-in Protection Features
Several protection features are built-in. Included are output current limiting, overvoltage protection, internal fuse protection, and over temperature shutdown.
Easy installation, safety and reliability
Integration is seamless with standard 12/13.8 VDC equipment. Front panel 'Anderson Power Pole; terminals and rear panel screw-wire terminals are heavy duty. Connectors are easy accessible which ensures safe and reliable installation.
(*) Intermittent Communication Service. Peak current limited to 50% max Duty Cycle, 5 minutes max ON time.