Astron Corporation SS-10, SS-12, SS-18, SS-25, SS-30 Data Sheet

...
Product Datasheet
SS Series
Switching Power Supplies
13.8 VDC, adjustable 10 – 50 Amps
Key Features
High efficiency switching technology, specifically filtered for communications equipment, all frequencies and HF
Built-in EMI filter certified to EN55022/CISPR 22 (Class-B), FCC Part15 (Class-B), EN55024, EN61000-3-2 (Class-A) ,
EN61000-3-3 (Harmonic)
Built-in protections: Current Limiting, Overvoltage protection, Fuse protection, Over Temperature shutdown
Low profile and light weight package. An optional rack-mount front panel is available
Heavy duty industrial design with metal construction quality
Certified Europe and North America to 60950-1 and CE safety standards.
Certified to Energy Star and CEC environmental standards, where required, and is RoHS (lead free) compliant
Applications
Electrical Specifications
POWER SUPPLY INPUT VOLTAGE:
115 to 220 VAC, 50/60Hz (Automatic selection)
OUTPUT VOLTAGE:
13.8 VDC max, adjustable ± 1 volt
OUTPUT CURRENT ICS (*)
Up to 50A peak (model SS-50M)
TEMPERATURE
Operating: -25 to +55ºC, Storage: -40 to +85ºC Overtemperature setting at 70ºC max
Desktop Models
Continuous Amps
ICS (*)
Size (HxWxD)
Wt (lbs)
SS-10 (*)
7
10
2⅜ x 6 x 9
3.2
SS-12 (*)
10
12
2⅜ x 6 x 9
3.4
SS-18 (*)
15
18
2⅜ x 6 x 9
3.6
SS-25 (*)
20
25
2⅞ x 7 x 9⅜
4.2
SS-30 (*)
25
30
2⅞ x 7 x 9⅜
5.0
With V/A Meters
Continuous Amps
ICS (*)
Size (HxWxD)
Wt (lbs)
SS-25M (*)
20
25
2⅞ x 7 x 9⅜
4.2
SS-30M (*)
25
30
2⅞ x 7 x 9⅜
5.0
SS-50M (*)
40
50
2⅞ x 7 x 9⅜
5.0
1/13 SS
WWW.ASTRONCORP.COM
9 Autry, Irvine, CA 92618 ● (949) 458-7277 ● Fax: (949) 458-0826
Communications Equipment Critical Power Solution
These power supplies are ideally suited for use with 12 VDC communications equipment. The switching technology has high efficiency and includes special filter circuitry for use with all frequencies including HF. To meet individual power requirements, peak currents from 10A to 30A are supported. Some models include Ampere and Voltage meters.
Protection Features
All models have built-in protection features including output current limiting, overvoltage protection, internal fuse protection, and over temperature shutdown.
Easy installation, safety and reliability
These units integrate seamlessly with standard 12/13.8 VDC equipment. The output screw-type terminals are heavy duty connections and easily accessible from the rear which ensures a safe and reliable installation
(*) ICS - Intermittent Communication Service. Peak current is limited to 50% max Duty Cycle, 5 minutes max ON time.
Loading...