Astron Corporation A4812-12, A4812-24 Data Sheet

Product Data Sheet
DC-DC Converter Series
Power Supplies
Isolated and Non-Isolated
13.8 VDC @ 12 / 24 Amps
Key Features
Input voltage range: 22 to 72Vdc, depending upon model
Handles up to an extra 25% peak current during peak power events
Built-in protections: Overvoltage, overcurrent and short-circuit protections with crowbar on Non-Isolated models
Up to 94% efficiency
48V Isolated models meet SAE-J1113-11 specification for Immunity to Transients (Surges)
LED visual indicators: DC-OK (Green) and Fault (Red)
Includes a separate Remote ON/OFF connection terminal for use with an ignition switch
High quality heavy duty industrial metal construction with easy access Terminal Block screw connections
RoHS (lead free) compliant
Applications
Electrical Specifications
OUTPUT VOLTAGE
13.8 VDC
MINIMUM EFFICIENCY (at Full Load)
92% min Non-Isolated models; 90% min Isolated models
TEMPERATURE
Operating: -25 to +55ºC, Storage: -40 to +85ºC Overtemperature setting at 70ºC max
Non-Isolated Models
Model
Input
Voltage
Continuous
Output
Peak Current
ICS (*)
Size (H x W x D)
Wt lbs (kg)
A4812-12
30 to 56 Vdc
9 A
12 A max
1.8 x 6.2 x 5.8
1.8 (0.8)
A4812-24
30 to 56 Vdc
18 A
24 A max
1.8 x 6.2 x 6.8
2.0 (0.9)
N2412-12
22 to 32 Vdc
10 A
12 A max
1.8 x 6.2 x 5.8
1.8 (0.8)
N2412-24
22 to 32 Vdc
20 A
24 A max
1.8 x 6.2 x 6.8
2.0 (0.9)
Isolated Models
Model
Input
Voltage
Continuous
Output
Peak Current
ICS (*)
Size (H x W x D)
Wt lbs (kg)
ISO4812-12
36 to 72 Vdc
10 A
12 A max
1.8 x 6.2 x 6.8
2.0 (0.9)
ISO4812-24
36 to 72 Vdc
20 A
24 A max
1.8 x 6.2 x 7.3
2.1 (1.0)
ISO2412-12
22 to 32 Vdc
10 A
12 A max
1.8 x 6.2 x 6.8
2.0 (0.9)
ISO2412-24
22 to 32 Vdc
20 A
24 A max
1.8 x 6.2 x 7.3
2.1 (1.0)
Model N2412-12
Model N2412-24
WWW.ASTRONCORP.COM
9 Autry, Irvine, CA 92618 ● (949) 458-7277 ● Fax: (949) 458-0826
Critical Power Solution for 13.8Vdc Mobile Equipment
These DC-DC Converter power supplies are ideally suited for use with mobile 12/13.8 VDC equipment. Both Isolated and Non-Isolated models are available. The design technology emphasizes high efficiency, tight regulation and low ripple/noise. To meet individual peak power requirements, models support peak currents up to 25% above nominal.
Protection Features
All models have built-in protection features including output current limiting, overvoltage protection, internal fuse protection, and over temperature shutdown. Isolated models include a crowbar on the output to prevent damage.
Easy installation, safety and reliability
These units integrate seamlessly with standard 12/13.8 VDC equipment. Screw-type terminal connections are used which are easily accessible and ensure a safe and reliable installation.
(*) Intermittent Communication Service. Peak current limited to 50% max Duty Cycle, 5 minutes max ON time.