Astrolux EC01 User Manual

-1-
-2-
-3-
-4-
The EC01 uses Andúril Firmware
User Manual
Safety precautions
Use only reputable 21700 cells of known origin.
Remove and recharge the cell when the low
voltage indication is given by the Lamp (repeated step-downs in light level and eventual shutdown of the light).
The extraordinary energy density that 21700 cells
offers also means that hazardous conditions are created when a cell is short-circuited or damaged. Always treat cells with respect and properly dispose of damaged cells.
The EC01 is a very high-intensity flashlight. Do not
point directly at a person, animal, moving vehicles or flammable materials.
When running at higher output levels the head of
the Lamp will quickly heat. This is normal. In warmer ambient conditions this temperature may
exceed 50ºC depending on your settings, so please
take the necessary precautions when handling the Lamp.
Quick start
Use one 21700 cell.
Unscrew the head and insert the battery. Take care
with the polarity: Plus points toward the head.
Screw the head back. The EC01 blinks once to
confirm it has power and is now operational.
Tighten the head. Do not over-tighten.
All functions are performed using the electronic
side switch. And basic usage is very simple: Click
for on/off, hold to change brightness. Release and
hold again to change brightness the other way.
From OFF, hold the button. The light output will
ramp up from a very low level to Ceiling-Of-The­Ramp. Release the button when the required light level is reached. (The full ramp takes about 3 s.) Use a single-click at any time to turn the EC01 OFF. Please see below for further details.
While ramping it does subtle blinks to signal: Max
regulated level (1x7135) and CEILING.
The EC01 has two different ramps: SMOOTH RAMP
and STEPPED RAMP. You can change between them when the lamp is ON with three clicks. Each
ramp has its own individual settings – for floor
(lowest level), ceiling (highest level). And the stepped ramp can also have a configurable number of steps.
TURBO is only for short times. At around a minute
you may notice it dims slowly down! The user should use it only for short periods instead of relying on thermal regulation to prevent heat damage. Full turbo is powerful enough to start fires in just a few seconds, especially when aimed at dark-colored materials.
Integrated charger
The EC01 has a USB-C charging port. Please use a premium cable and a power adapter with 5V, 2A to charge your lamp.
While charging the switch LED is red. It goes green when charging is finished. .
While charging you can use BattCheck mode from the Group 1 Blinkies to check the voltage level and all other flashlight functions can be used normally when charging.
Specifications
A 21700 CREE LED lamp with side switch and a great, easy user interface.
Emitter: CREE XHP50.2(3V) LED on a copper DTP MCPCB
Lens: High transmittance glass Flux: ~3500 lm
Throw: ~298 m Firmware: The EC01 uses free software called Andúril,
distributed under the terms of the GPL v3. Code is available from
http://tiny.cc/TKAnduril
User interfaces: [1] By default the EC01 is set to use
SMOOTH RAMPING. Instant access to TURBO mode is also provided.
[2] A more conventional STEPPED RAMPING UI is available if you like discrete
modes level. You can choose how many steps you want.
[3] MOMENTARY mode is useful for signaling purposes or rapidly/briefly lighting up targets. To exit this mode, physically disconnect power
[4] MUGGLE mode uses a reduced output. [5] It has an electronic LOCKOUT for safety,
but acts also as momentary low light.
Other functions: Battery check, sunset, beacon,
tactical strobe, party strobe, bike flasher, candlelight, lightning storm
Battery: one premium 21700 cells. Unprotected cells
are recommended.
Charging: Integrated charger via USB-C
Driver: FET+1 driver. Low parasitic drain while OFF Body: Aluminum with HA III anodizing
Switch: Electronic side switch Ingress rating: Equivalent to IPX8
Weight: Approximately 119 g without cells Size: 37 mm Ø head x 120 mm length.
Manual design and concept by J. Hollmann. Content from budgetlightforum, collected over time. Many thanks to ToyKeeper for her great software!
Rev. A
-5-
-6-
-7-
-8-
UI Diagram
Not everything is covered in the diagram, please read the text.
Default UI: Smooth ramping
This UI provides smooth dimming of the light output between FLOOR (lowest level) and CEILING (highest level), with an easily accessible 100% TURBO mode.
Switch to STEPPED RAMP: If the lamp is ON:
Three clicks (Hint: If you use 3 clicks from OFF you engage battery check)
Turn the lamp ON: single-click the button, the EC01
turns ON using the previously used light output level (MEM)
Ramp up; brighter: hold the button
Reverse ramp: while ramping in one direction,
release button briefly and hold again
Ramp down; darker: Click, hold, when ON
(means: double-click, but hold the second click a bit longer)
If you do this when the lamp is OFF, it ramps down from the CEILING (dashed double lines)
Instant top CEILING: from OFF: double-click
(double lines)
TURBO: from ON: double-click toggles
between turbo and the memorized level from OFF (You must first switch ON): Click, then double-click
FLOOR / MOON mode: from OFF: Hold
turns on at the FLOOR level, it
makes a subtle “blink” to provide
a timing hint if you want to stay there. If you keep holding, it ramps up
Battery check: from OFF: triple-click (4 blinks, a
short pause, then 1 blink would indicate 4.1 V)
Turn the EC01 OFF: single-click
UI: Stepped ramping
Using this UI the output does not ramp, it steps from one mode to the next using hold. The firmware tries to optimize these steps as equally-spaced on a cube-root curve (considered an ideal mode-spacing by many). In STEPPED RAMPING you can choose how many steps you want. (See Ramp configuration for details).
All operations are the same as in smooth ramping
Switch to SMOOTH RAMP: when the lamp is ON:
Three clicks (Hint: If you use 3 clicks from OFF you engage battery check)
UI: Momentary mode
5 clicks from OFF to enter Momentary mode To exit this mode, physically disconnect power
(unscrew the light).
This mode locks the flashlight into a single-mode interface where the LEDs are only on when the button is held down. It is intended for Morse code and other signaling tasks. Brightness is the last-ramped level, so adjust that before entering momentary mode.
UI: Muggle mode
Muggle mode is for lending the EC01 to others. It has a
reduced output to make sure somebody won’t start a
fire. An extremely simple interface with a limited brightness range ~5 lm to ~240 lm, with slow smooth ramping and no blinkies. Persists after a battery change.
MUGGLE mode ON: from OFF 6 clicks to enter
MUGGLE mode OFF: 6 clicks to exit
One click ON / OFF and HOLD to ramp up / down.
UI: Electronic Lockout
4 clicks form OFF to disable the EC01, same to re­enable the lamp. Lockout makes the light safe to carry in a pocket or a bag or anywhere else it might be pressed by accident. Lockout doubles also as a momentary moonlight mode, so the user can do quick tasks without having to unlock the light. It uses the FLOOR of the current ramp.
Loading...
+ 2 hidden pages