ASTRODYNE PV15 Service Manual

Compact 15 Watt Enclosed Switching Power Supplies
P V 1 5 s e r i e s
ASTRODYNE USA: 1-800-823-8082
WWW.ASTRODYNE.COM
ASTRODYNE EUROPE: 353 51 561060
ASTRODYNE PACIFIC: 886-2-26983458
Universal 90-264VAC Input
Compact Footprint
Regulated Outputs
3000V Isolation
Built in EMI Filter
Model Number Output Voltage Output Amps (max) Ripple/Noise pp,typ Efficiency
PV15-5S 5 VDC 3 80mV 77% PV15-12S 12 VDC 1.25 120mV 80% PV15-15S 15 VDC 1 120mV 80% PV15-24S 24 VDC 0.63 120mV 80% PV15-48S 48 VDC 0.32 120mV 80%
2.59”W x 1.98”L x 1.1”H
查询PV15供应商
Compact 15 Watt Enclosed Switching Power Supplies
P V 1 5 s e r i e s
ASTRODYNE USA: 1-800-823-8082
WWW.ASTRODYNE.COM
ASTRODYNE EUROPE: 353 51 561060
ASTRODYNE PACIFIC: 886-2-26983458
INPUT SPECIFICATIONS
Input Voltage Range AC/DC 90-264 VAC / 125-370 VDC Frequency Range 47-63 Hz Inrush Current, typ: 20A @ 120VAC Input * 40A @ 220VAC Input *
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart Load Regulation (20% to 100%) ± 0.5%, typ.; 1% max. Line Regulation ± 0.5%, typ.; 1% max. Preset Accuracy 1%, typ DC Voltage Adjust (typ) ± 10% Temperature Coefficient ± 0.03%/°C (0-50°C, typ.) Ripple/Noise See Selection Chart Over Voltage Protection Clamp * Short Circuit Protection Latching, recoverable after cooling and re-power Hold Up Time 16mS, typ (Nom I/P, FL)
GENERAL SPECIFICATIONS
Isolation I/P-O/P: 3000VAC I/P-Ground: 1500VAC O/P-Ground 500VAC Efficiency See Selection Chart Switching Frequency 65Khz, (fixed, typical) Safety Approvals UL60950-1, EN60950-1
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -20 to +70°C (See Derate) Storage Temperature -20 to +85°C * Relative Humidity 0% to +95%, non-cond * EMC EN55022 Class B EN61000-3-2,3 EN61000-4-2,3,4,5,6,8,11 ENV50204
PHYSICAL SPECIFICATIONS
Size 2.59” x 1.98” x 1.1” (66mm x 50.4mm x 28mm) Construction Enclosed Weight 0.275 lb, (125g)
DERATE CURVE
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25°C unless other­wise noted
Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.