Compact 15 Watt Enclosed Switching Power Supplies
P V 1 5 s e r i e s
ASTRODYNE USA: 1-800-823-8082
WWW.ASTRODYNE.COM
ASTRODYNE EUROPE: 353 51 561060
ASTRODYNE PACIFIC: 886-2-26983458
INPUT SPECIFICATIONS
Input Voltage Range AC/DC 90-264 VAC / 125-370 VDC
Frequency Range 47-63 Hz
Inrush Current, typ: 20A @ 120VAC Input *
40A @ 220VAC Input *
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Load Regulation (20% to 100%) ± 0.5%, typ.; 1% max.
Line Regulation ± 0.5%, typ.; 1% max.
Preset Accuracy 1%, typ
DC Voltage Adjust (typ) ± 10%
Temperature Coefficient ± 0.03%/°C (0-50°C, typ.)
Ripple/Noise See Selection Chart
Over Voltage Protection Clamp *
Short Circuit Protection Latching, recoverable after cooling
and re-power
Hold Up Time 16mS, typ (Nom I/P, FL)
GENERAL SPECIFICATIONS
Isolation I/P-O/P: 3000VAC
I/P-Ground: 1500VAC
O/P-Ground 500VAC
Efficiency See Selection Chart
Switching Frequency 65Khz, (fixed, typical)
Safety Approvals UL60950-1, EN60950-1
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -20 to +70°C (See Derate)
Storage Temperature -20 to +85°C *
Relative Humidity 0% to +95%, non-cond *
EMC EN55022 Class B
EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11
ENV50204
PHYSICAL SPECIFICATIONS
Size 2.59” x 1.98” x 1.1”
(66mm x 50.4mm x 28mm)
Construction Enclosed
Weight 0.275 lb, (125g)
DERATE CURVE
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.