Isolated and Regulated 7 WATT Open Frame DC/DC Converter
A S D 0 7 H s e r i e s
300 Myles Standish Blvd., Taunton, MA 02780
Ph: 1-800-823-8082 Fax: 508-823-8181
WWW.ASTRODYNE.COM
INPUT SPECIFICATIONS
Input Voltage, Nominal 12VDC 48VDC
Input Voltage Ranges 9-36 18-75 VDC
Input Surge Voltage 50V (12V Models), *
100V (48V Models), *
10 mS duration, min.
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Preset Accuracy Singles: +/- 1% max.
Duals: +/- 2% max.
Cross Regulation (Duals) 5-8% typ.
Load Regulation singles: +/- 0.5%
20% - FL duals: +/-1%, +/-3% (5V mod)
Line Regulation singles: +/- 0.5%
duals: +/- 1%
Temperature Coefficient +/-0.03%/°C
Ripple/Noise (Pk-Pk, typ)
Single 3.3V 100mV
Single 5, 9,12, 15V 50mV
Dual 5V 150mV (12Vin) 100mV (48Vin)
Dual 12, 15V 50mV
Overvoltage Protection Clamp, 130-150% *
Short Circuit Protection Continuous, self-recovering
GENERAL SPECIFICATIONS
On/Off Control (Ref to - Input pin)
Logic “1”/Open=ON
Logic “0”/GND=OFF
Shutdown Idle Current 15mA
Input-Out Isolation 1500VDC (48V)
500 VDC (12V)
In/Out Capacitance 1000 pF
Efficiency 82%, typ
Switching Frequency 450Khz
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -25 to +71°C(FL)
Relative Humidity 0 to 95%, non-cond
Storage Temperature -40 to +125°C *
Maximum Heatsink Temp 110°C *
Input Fusing 12V: 4A, 48V: 2A
MTBF 1,000,000 Hrs
Mil Std 217, 25°C
Shock/Vibration To MIL-STD 810°C
Safety EN60950 TUV File # B 02 10 22749 038
UL60950-1 UL File # E167432
PHYSICAL SPECIFICATIONS
Heatsink Material Aluminum
Construction Open Frame
Weight 0.57 oz, (16g)
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.