Astro 2616 User Manual

2616
3/8" FILTER, REGULATOR AND LUBRICATOR WITH GUAGE
www.astrotools.com
• Prevents costly damage to air tools caused by rust, scale and moisture
• Convenient minimum installation time into your compressed air system
• Provides clean, dry, regulated compressed air over a wide range of airflows with accurate control and fast response
• Efficiently traps moisture while passing through clean, dry compressed air
• Gauge has rugged polycarbonate case with 2" face
• 1/4" or 3/8" NPT with Max 135psi
• 9-2/5" (L) x 2-2/5" (W)
• Weight: 3lbs.
•Astro Pneumatic Tool Co. warrants our products to the original user against defective material or workmanship for a period of 1 year (except where noted on our price schedule) from the date of 1st use. Astro reserves the right to determine whether the product failed because of defective material, workmanship or other causes and to charge back for missing parts. Astro Pneumatic Tool Co., at its discretion, will repair products covered under this warranty free of charge. The distributor should direct the original user to return the product (with the exceptions listed below) with the distributor’s name, address, adequate proof of date of purchase or a copy of warranty card, and a short note explaining the problem.
Failures caused by accident, alteration, or misuse are not covered by this warranty.
•Astro Pneumatic Tool Co. or its authorized service representatives must perform all warranty repairs. Any repair to the product by unauthorized service representatives voids this warranty. The rights under this warranty are limited to the original user and may not be transferred to subsequent owners.
•This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability and fitness for a particular purpose. Some states do not allow the exclusion of limitations of incidental or consequential damages so the above limitations may not apply to you. All claims must be sent to:
Astro Pneumatic Tool Company 372 Old US Highway 52 South Mt. Airy, NC 27030
1 YEAR LIMITED WARRANTY
PLEASE CALL 1-800-221- 9705
FOR REPAIR AND RETURN INSTRUCTIONS
Unpacking
When unpacking, check the parts diagram and part number listing on page 3 to make sure all parts are included. If any parts are missing or damage, please call your distributor.
3/8" FILTER, REGULATOR AND LUBRICATOR WITH GUAGE
Page 1
2616
Instruction
3/8" FILTER, REGULATOR AND LUBRICATOR WITH GUAGE
PRECAUTION ON HANDLING
MOUNTING
Install the unit as close as possible to the
1. pneumatic equipment of which they are used for. Make sure that air flows in from IN. ( the end with
2. mark which is located on the bottom of the unit) Install filters and lubricators with the bowls at
3. the bottom. When a regulator is mounted using a bracket, remove
4. the fixing ring, insert the bracket and fix it with the fixing ring. Use the bracket to mount the filter or the
5. lubricator. Insert the bracket and fix the unit in place by tightening the set bolts. When two or more units are installed, fix them by
6. using the bracekts on both ends.
Note: If they are fixed at one position only, be careful as vibration or shock may couse the bracket to be loosened.
DRAIN / DISCHARGE (FILTER)
1.
Drain before it reaches the baffle plate.
2.
Turn the drain knob conterclockwise for draining.
Note: Handle the drain knob with fingertips. Turning the knob too tightly may damage it.
PRESSURE REGULATION (REGULATOR)
1.
When turning the handle clockwise, it increases the secondary pressure. When turning it counterclockwise, it decreases the pressure.
2.
Pull the handle out for the pressre regulation. After the pressure is set, push the handle into the main unit. It will be locked.
Note: Forcing to tun the handle when it is locked may cause an air leakage or an impossilbe pressure regulation
Some parts in this unit are made of polycarbonate.
1. Never use in the atmosphere of organic solvent. Use
2. neutral cleanser for cleaning. Make sure that the sevice pressure does not exceed
3.
9.5kgf/cm2.
3.
When the supply pressure is high and the setting pressure is low, it may cause pulsation to the atmo­spheric pressure to the other end. Throttle the output end in such a case.
METHOD OF LUBRICATION AND OIL VOLUME REGULATION (LUBRICATOR)
Replenish with air tool oil until bowl is 80% full.
1. For oil supply volume regulation, turn the handle
2. counterclockwise for increasing and clockwise for desceasing. (0 is minimum and 9 is maximum. How­ever, it is not possible to trun from 9 to 0)
3/8" FILTER, REGULATOR AND LUBRICATOR WITH GUAGE
Page 2
Loading...