Astria Fireplaces Inglenook CRP2, Inglenook CLP2 Installation And Operation Instruction Manual

Page 1
P/N 126647-01 Rev. E 02/2018
US
INSTALLATION AND OPERATION
INSTRUCTIONS
Astria® Multi-Sided
Wood burning Fireplaces
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 126647-02.
PFS
C
REPORT NO. 09-146
®
MODELS
Inglenook CRP2 Inglenook CLP2
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil. Consommateur : Conservez cette notice pour consultation ultérieure.
This wood burning fireplace complies with UL127 CAN/ULC-S610-M87 standard as a FACTORY BUILT FIREPLACE.
Ce foyer au bois est conforme aux UL 127 CAN/ULC­S610-M87 norme comme une USINE CONSTRUITE CHEMINÉE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. An INNOVATIVE HEARTH PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Ac­cessories, page 17).
FOR CANADA: The authority having jurisdiction (such as the municipal building department, fire department, etc.) should be contacted before installation to determine the need to obtain a permit.
POUR LE CANADA: L’autorité compétente (comme le service municipal du bâtiment, les pompiers, etc.) doit être contacté avant l’installation afin de déterminer la nécessité d’obtenir un permis.
This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
NOTE: DIAGRAMS AND ILLUSTRATIONS THROUGHOUT THE MANUAL ARE NOT TO SCALE.
Page 2
Thank you for your purchase. We appreciate your business!
Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
Please read and understand these instructions before installing or operating.
SAFETY
TABLE OF CONTENTS
Safety .............................................................................................2
Dimensions ....................................................................................4
Fireplace Installation ......................................................................5
Venting Installation ........................................................................7
Optional Gas Line Installation ......................................................13
Operation and Maintenance Guidelines ........................................14
Replacement Parts .......................................................................15
Technical Service .........................................................................15
Fireplace Accessories ...................................................................16
Installation Accessories ...............................................................16
Important Notices - Canada ........................................................18
Draft Smoke Guidelines - Appendix A .........................................19
Warranty ......................................................................................23
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assistance or additional information. Consult a qualified installer or local distributor.
IMPORTANT: Check local codes before installing this fireplace.
This fireplace model is a wood burning fireplace intended and ap­proved for installation in either residential homes or buildings of standard construction. This fireplace system requires the utilization of INNOVATIVE HEARTH PRODUCTS, LLC’s (IHP) 8", double-wall, and snap lock flue pipe system. Optional glass doors in several finishes are available for this fireplace (see Replacement Parts, page 15 and Accessories on page 16).
Before beginning installation of this fireplace, read these instructions through completely.
• This IHP fireplace and its components are safe when installed according to this installation manual. Unless you use IHP com­ponents, which have been designed and tested for the fireplace system, you may cause a fire hazard.
• The IHP warranty will be voided by and IHP disclaims any respon­sibility for the following actions.
a. Modification of the fireplace, components, doors, air inlet system and damper control.
b. Use of any component part not manufactured or approved by IHP in combination with an IHP fireplace system.
Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces.
WARNING: This model is not for use in manufac-
tured housing (mobile homes).
WARNING: Do not install a fireplace insert in this fireplace unless the manufacturer's instructions with the insert specifically state this fireplace has been tested for use with this insert.
FOR YOUR SAFETY
• Do not store or use gasoline or any other flammable
vapors or liquids in the vicinity of this or any other appliance.
• Due to high temperatures, the appliance should be
located out of traffic and away from furniture and draperies.
• Do not place clothing or other flammable materials
on or near the appliance.
• Never leave children unattended when a fire is
burning in the fireplace.
WARNING: Use solid wood or processed solid fuel fire logs only. Do not poke or stir the logs while they are burning. Use only firelogs that have been evaluated for the application in fireplace and refer to firelog warnings and caution markings on packaging prior to use.
This fireplace is not intended to be used as a sub­stitute for a furnace to heat an entire home. Use for supplemental heat only.
Overfiring of a fireplace is a condition where exces­sive temperatures are reached, beyond the design capabilities of the appliance. The damage that occurs from overfiring is not covered under the manufacturer’s limited warranty.
2
Astria.us.com
126647-01_E
Page 3
SAFETY Continued
WARNING: CONTINUED OVERFIRING CAN PER­MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. SOME EXAMPLES OF CONDITIONS THAT COULD CAUSE OVERFIRING ARE:
• BURNING QUANTITIES OF SCRAP LUMBER, PINE BRANCHES, PAPER OR CARDBOARD BOXES WHICH EXCEED THE VOLUME OF THE NORMAL LOG FIRE.
• BURNING TRASH, CHEMICALS OR CHEMICALLY TREATED COMBUSTIBLES.
Disposal of Ashes Ashes should be placed in a metal container with a
tight-fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
WHEN USING THE DECORATIVE APPLIANCE, THE FIREPLACE DAMPER MUST BE SET IN THE FULLY OPEN POSITION.
Never use gasoline, gasoline-type lantern fuel, kero­sene, charcoal lighter fluid, or similar liquids to start or ’freshen up’ a fire in this fireplace. Keep all such liquids well away from the fireplace while it is in use.
WARNING: BURNING IMPROPER FUEL (I.E. CHARCOAL) CAN RESULT IN CARBON MONOXIDE POISONING, WHICH MAY LEAD TO DEATH!
Carbon Monoxide Poisoning – Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, get fresh air at once! Have the appliance inspected by a qualified service technician. Some people are more af­fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Ventilation Requirements - Provide adequate air for combustion. The fresh air requirements of this ap­pliance must be met within the space where it will be installed.
Smoke Detectors - Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible, install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the heat produced by the appliance). If your local code requires a smoke detector be installed within the same room, you must follow the requirements of your local code. Check with your local building department for requirements in your area.
Creosote – Formation and Need for Removal
Use SOLID WOOD only for fuel. It is best to use dry and well seasoned hardwood. Softwoods tend to burn very quickly. DO NOT use treated wood, charcoal, coal, trash, driftwood or woods that have been dipped in tar, pitch, pine tar, creosote, etc. Wood products made with synthetic binders, such as plywood, produce ab­normally high temperatures and sputtering, smoking fires. When burning artificial logs, please read and follow the instructions provided by the manufacturer.
Never burn treated construction lumber or scraps. These woods burn excessively hot and may contain chemicals used to treat insects and fungus. When burned, these chemicals can pose a significant hazard.
IMPORTANT: See appendix A, page 19 for additional information regarding draft requirements, smoking causes and troubleshooting.
126647-01_E
Astria.us.com
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire.
The chimney shall be inspected at least twice a year during the heating season to determine when a creosote buildup has occurred. When creosote has accumulated (1/8" [3 mm] or more) it shall be removed to reduce the risk of a chimney fire.
3
Page 4
SAFETY Continued
(1080 mm)
WARNING: Always leave glass doors fully opened or fully closed when operating fireplace.
WARNING: Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition. Young children should be carefully supervised when in the same room as fireplace.
DIMENSIONS
31" (788 mm)
22"
(559 mm)
18-7/8"
(480 mm)
39-1/8" (994 mm)
13"
(331 mm)
MODEL CATALOG NO.
Inglenook CRP2 F0698 Inglenook CLP2 F0699 Inglenook CRP2 F0700 Inglenook CLP2 F0701
42-1/2"
(1016 mm)
40"
10-1/2"
(667 mm)
36" (915 mm)
39-1/8" (994 mm)
(204 mm)
16-1/4"
(413 mm)
22-3/4"
(578 mm)
7" (178 mm)
8"
8-3/4"
(223 mm)
20" (508 mm)
12" (305 mm)
20" (508 mm)
Figure 1 - Dimensions
4
Astria.us.com
126647-01_E
Page 5
FIREPLACE INSTALLATION
GLOSSARY Flush Installation - type of installation where front face of fireplace
is even or level with wall.
Chase Installation - type of installation where chimney is enclosed. Perpendicular Side Wall - applies to minimum clearance between
side wall and fireplace opening. Nailing Flange - extended part on both sides of fireplace face that
secures fireplace to wall.
Termination - cap that is placed at end of chimney pipe. SELECTING LOCATION
To determine safest and most efficient location for fireplace, you must take into consideration the following guidelines:
1. The location must allow for proper clearances (see below).
2. Consider a location where the fireplace will not be affected by drafts, air conditioning ducts, windows or doors.
3. A location that avoids the cutting of joists or roof rafters will make installation easier.
4. If an outside air kit is to be installed, accessibility to outside combustion air must be considered. This can also be achieved through a vented crawl space in some cases (see Optional Outside Air Kit on page 7).
5. If gas line is to be installed, consider location of gas supply.
MINIMUM CLEARANCE TO COMBUSTIBLES
Back and sides of fireplace 3/4" (19 mm) Min.* Top spacers 0" (0 mm) Perpendicular side wall to opening of unit 24" (610 mm) Min. Btm. of fireplace to floor (step 2 of Framing) 0" (0 mm) Min. Mantel clearances see Mantel clearances, page 6 Chimney outer pipe surfaces 2" (51 mm) Min.
Chase inside dimension 16 1/2" (420 mm) Min.
WARNING: DO NOT PACK REQUIRED AIR SPACES
WITH INSULATION OR OTHER MATERIALS. Do not obstruct fireplace openings (ie. louvers, etc.)
with any type of facing material. Combustible mate­rial must not be in contact with back of front face of fireplace.
38-5/8"
(981 mm)
43" (1093 mm)
FRONT VIEW SIDE VIEW
Figure 2 - Framing Dimensions
16-1/2"
(419 mm)
2x4 Stud for Nailing Flange Back and Side
52"
(1321 mm)
Minimum
Perpendicular Wall
Figure 3 - Corner Installation
5. Before securing fireplace to prepared framing, ember protector (provided) must be placed between hearth extension (not sup­plied) and under bottom front edge of fireplace to protect against glowing embers falling through. If fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. Ember protector should extend under fireplace a minimum of 1". Ember protector should be made of galvanized sheet metal (28 gauge minimum) to prevent corrosion (see Figure 5).
6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace (see Figure 4).
24" (610 mm) Min.
21-1/2"
(546 mm)
10-7/8"
(277 mm)
to Unprotected
Wall
Combustible Wall
FRAMING
1. Frame opening for fireplace using dimensions shown in Figures 2 and 3.
2. If fireplace is to be installed directly on carpeting, tile or any combustible material other than wood flooring, fireplace must be installed upon a metal or wood panel extending full width and depth of fireplace.
3. Set fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing.
4. Check level of fireplace and shim with sheet metal if necessary.
126647-01_E
Astria.us.com
Nailing Flange
Nail or Screw
Figure 4 - Nailing Flanges
5
Page 6
FIREPLACE INSTALLATION Continued
9 5/
HEARTH EXTENSION
A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace. Fab­ricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of k = .84 BTU IN/FT2 HR °F (or less) at 1" thick. For example, if material selected has a k factor of 0.25, such as glass fiber, the following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84
Thermal conductivity "k" of materials can be obtained from manu­facturer or supplier of noncombustible material. If hearth extension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non-combustible material such as sand-cement grout (see Figure 3, page 5).
WARNING: Hearth extension is to be installed
only as shown in Figure 5.
Seal Cap
Ember Protector
Hearth Extension
12 1/4"
(312 mm) Ref.
Combustible Material
Safe Zone for
6"
(153 mm) Ref.
33°
Projection of Combustible Materials
3" (77 mm)
Nom.
12"
(3045 mm)
Min.
9" (229 mm) Min.
11/2"
(39 mm)
Max.
Upper
Section of
Fireplace
Fireplace Opening
Figure 6 - Mantel Clearances
Example 1: The face of a mantel, bookshelf, etc. is made of combus­tible material and protrudes 2 3/4" from the wall on which the fireplace is installed. The combustible material must be a minimum of 4" from side of fireplace opening.
Example 2: The face of a mantel, bookshelf, etc. is made of com­bustible material and protrudes 11/16" from the wall on which the fireplace is installed. The combustible material can butt up against side of fireplace (i.e. 1" from fireplace opening).
Do Not Block Louver
Seal Cap
Hearth Extension
Ember Protector
Figure 5- Hearth Extensions
MANTEL CLEARANCES
Woodwork such as wood trims, mantels or any other combustible material must not be placed at least 9" above opening of fireplace (see Figure 6, page 6). Combustible materials above 9" and projecting more than 1 1/2" from the fireplace front face must not be at least 12" above fireplace opening (NFPA 211, Section - Clearance from Combustible Material).
Mantels or any other combustible material may also come up to the side edge of the black metal face of the fireplace. Clearances from side of fireplace to any combustible material and wall should fall within the limits show in Figure 7.
No Combustible Material on Face of Firebox
Fireplace Opening
1" Both
Sides
Example 1
Example 2
0123 45 678910 11 12 13 14
Minimum 24" from Perpendicular Side Wall
Figure 7 - Minimum side clearances
8 15/ 8 1/
7 9/ 6 7/ 6 3/ 5 1/ 4 13/ 4 1/ 3 7/
2 3/ 2 1/
3
/
1 11/16
8
16
4
16
8
16
2
16
8
16
4
16
8
6
Astria.us.com
126647-01_E
Page 7
VENTING INSTALLATION
OPTIONAL OUTSIDE AIR KIT (MODELS AK4 OR AK4F)
The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it’s location. Outside combustion air is accessed through and exterior wall (AK4) or a vented crawl space (AK4F). See Figure 8 and Accessories on page 16. Avoid installing outside air eyebrow in areas where inlet opening may be blocked by snow, bushes or other obstacles. It should also be located beyond the reach of children.
CAUTION: Combustion air inlet ducts shall not
terminate in attic space.
The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.
For further details on installation of outside air kit, please refer to instructions included with air kit. For operating instructions, please refer to your owner’s manual.
Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)
Air Inlet Location Must Allow For Bushes or Snow
Air Inlet Eyebrow
Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space)
Figure 8 - Air Kit Installation
Outside air handle is located on left-hand side of fireplace refractory (see Figure 9, Model Inglenook CRP2 shown). To close, pull down; to open, push up. Always open mechanism when starting a fire to provide adequate outside combustion air. Close mechanism when not in use to prevent cold air from entering room.
Air Kit Damper Rod- Closed Position
Open Position
Vent Hood Required for Wall Installation
CHIMNEY SYSTEM
WARNING: Label part number 900599-01 must be applied by the installer to all chimney pipe sections but is not required on sections that will be visible after the installation is complete. Label must wrap around the circumference of the pipe. See accessories, page 17 for Kit F2659.
Chimney height
Minimum chimney height measured fro bottom of fireplace to flue gas outlet-end of termination is:
Straight run 14 feet Run with one elbow set 15 feet Run with two elbow sets 24 feet An elbow set consists of one starter elbow and one return elbow.
Uncommon circumstances such as neighboring hills, tall trees, or strong wind areas can cause downdrafts in chimney system. In such cases, going beyond minimum recommended height would be preferable to provide a better draw.
Maximum height approved for any chimney run with this fireplace system is 60 feet as measured from fireplace bottom to flue outlet end of termination.
Double Wall Chimney System
An IHP chimney system consists of 12", 18", 24", 36" and 48" snap­lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in lineal gain chart (see Figure 10, page 8).
Lineal gain is actual measurable length of a part after two or more parts are connected.
Each double wall chimney section consists of a galvanized outer pipe, a stainless steal inner flue pipe and a wire spacer. Pipe sections must be assembled independently as chimney is installed. When connecting chimney directly to fireplace, inner flue pipe section must be installed first with lanced (female) side up (see Figure 10, page 8). Outer pipe section can then be installed over flue pipe section with hemmed (male) end up. Press down on each pipe section until lances securely engage hem on fireplace starter. The wire will assure proper spacing between inner and outer pipe sections.
Continue to assemble chimney sections as outlined above, making sure both inner and outer pipe sections are locked together.
When installing double wall snap-lock chimney together, it is impor­tant to assure the joint between chimney sections is locked. Check by pulling chimney upward after locking. Chimney will not come apart if properly locked. It is not necessary to add screws to keep chimney together. However, if desired, use screws per directions provided on page 8, Figure 11.
Note: For Canada, use chimney parts designated HT.
Lower Left Side of Fireplace Opening
126647-01_E
Figure 9- Air Kit Damper Rod
Astria.us.com
7
Page 8
VENTING INSTALLATION Continued
WARNING: The opening in collar around chimney at top of fireplace must not be obstructed. Never use blown insulation to fill chimney enclosure.
12 3/8" Galvanized Outer Pipe
Lanced Ends (Male)
PART NO. DESCRIPTION GAIN
Inglenook CRP2/CLP2 Fireplace 42
12-8DM Pipe Section 10 5/8" 18-8DM Pipe Section 16 5/8" 24-8DM Pipe Section 23 5/8" 36-8DM Pipe Section 34 5/8" 48-8DM Pipe Section 46 5/8" RT-8DM Round Termination 6 7/8"*
RTL-8DM Round Termination 7 3/4"*
RTT-8DM
RTTL-8DM
ET-8DM
ETL-8DM
ETO-8DM
ETLO-8DM
*Lineal Gain for Terminations is measured to Flue Gas Outlet Height.
LINEAL GAIN
Round Termination
with Slip Section
Round Termination
with Slip Section
Square Chase
Termination
Square Chase with
Slip Section
Square Chase
with Mesh
Square Chase with
Mesh and Slip
Section
Hemmed Ends (Female)
8" Stainless Inner Pipe
"
6 7/8" to 23 1/8"* 7 3/4" to 21 1/2"*
12"*
7" to 15"*
12"*
12" to
21 1/2"*
OFFSET RISE CHIMNEY LENGTH
A B 48" 36" 24" 18" 12"
4 3/8" 16 3/8"
ELBOW SET ONLY
9" 25 3/4" 1
11 7/8" 31" 1
15" 37 3/8" 1
16 3/4" 40 1/2" 1 1
20" 47 1/8" 1 22 5/8" 52 1/8" 1 1 25 1/2" 57 7/8" 1 27 5/8" 62" 1 1 30 3/8" 67 1/4" 1 1
33" 72 5/8" 1 1 35 3/4" 78" 2 37 7/8" 82" 1 1 1 41 1/4" 88 5/8" 1 1 43 3/8" 92 3/4" 2 1 46 5/8" 99 3/8" 2 48 3/4" 103 1/2" 1 1 1 51 1/2" 108 7/8" 2 1 54 1/4" 114 1/8" 2 1
57" 119 1/2" 1 2
59" 123 5/8" 2 1 1 61 3/4" 129" 1 2 1 64 1/2" 134 3/8" 1 2 1 67 1/4" 139 5/8" 4
OFFSET CHART (22-50 FT. SYSTEM HEIGHT)
Figure 10 - Lineal Gain
USING CHIMNEY OFFSETS
To achieve desired offset, you may install combinations of 12", 18", 36" and 48" length of double wall pipe (see offset chart and Figure 11, this page and Figure 12, page 9).
Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 13, details A & B, page 9).
Maximum length of pipe between supports (return elbow or chimney support V12S-8DM) is 6' of angled run. Maximum of two 6' angled run sections per chimney system.
8
Astria.us.com
Screws
B
A
Figure 11 - Raise and Offset
126647-01_E
Page 9
VENTING INSTALLATION Continued
Offset Elbow
Return Elbow
DETAIL A
6' (1.88 m)
Max.
6' (1.88 m)
Max.
Return Elbow
Return Elbow
Offset
6' (1.88 m)
Max.
Ceiling Support Pipe 12S-8DM
Offset Elbow
Offset Elbow
Offset Elbow
Elbow
Return Elbow
6' (1.88 m)
Max.
A B C
Figure 12 - Typical Offset Installations
Return Elbow
6' (1.88 m)
Max.
6' (1.88 m)
Max.
Existing Ceiling Frame
See DETAIL A
Return
Straps
Ceiling Support Pipe 12S-8DM
Angle Firestop
Elbow
See DETAIL B
Straps
DETAIL B
Figure 13 - Chimney Supports
FIRESTOP SPACERS (FS-8DM)
Firestop spacers are required at each point where the chimney pen­etrates a floor or ceiling joist space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials.
When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 14. When the pipe passes through a framed opening into an attic space above, the firestop must be placed on the attic floor as shown in Figure 15.
Screws or Staples
Firestop
(Min. of 8)
Spacer
Figure 14 - Firestop Spacer with Living Space Above Ceiling
Firestop Spacer
Screws or Staples (Min. of 8)
Existing Ceiling Frame
Figure 15 - Firestop Spacer with Attic Space Above Ceiling
IMPORTANT NOTICE
When penetrating a ceiling into an attic, a firestop thimble (38FST or FST30) is required to avoid intrusion by insulation and recommended to negotiate a joist (see Figure 15a, page 10).
126647-01_E
Astria.us.com
9
Page 10
Thimble 38FST or FST30
Firestop
VENTING INSTALLATION Continued
12S-8DM Support
Figure 15a - Firestop Thimble
SUPPORT SECTIONS (12S-8DM)
The chimney support section is a 4-strap 12" length of pipe. The height of a vertical chimney pipe supported ONLY by the fireplace, must not exceed 20 feet. Chimney heights above 20 feet must be supported.
20 FT.
(6.10 m)
Figure 16 - Support Sections
RT-8DM
20 FT.
(6.10 m)
Return Elbow
Effective Height of Termination Cap
Effective Height of Termination Cap
14' (4.27 m)
Min. Height
Effective Height of Termination Cap
15' (4.57 m)
Min. Height
RT-8DMRT-8DM
Maximum
Height
60' (18.29 m)
2' (.61 m)
Max
Pipe Length
30E-8DM
Standard Installation Alternate Installation
Figure 17 - Typical Installation
10
Astria.us.com
126647-01_E
Page 11
VENTING INSTALLATION Continued
(762 mm)
PENETRATING ROOF
To maintain a 2" clearance to pipe on a roof with a pitch, a rectangular opening must be cut.
1. Determine center point where pipe will penetrate the roof.
2. Determine center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" measure horizontally down from roof rafters.
3. Use roof opening chart (Figure 18) to determine correct opening length and flashing required.
4. Remove shingles around opening measured. Cut out this section.
16 3/8"
(416 mm)
Min.
2"
(51 mm)
Min.
2"
(51 mm)
Min.
30" Min.
2"
(51 mm)
Min.
FLASHING INSTALLATION
Determine flashing to be used with roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 19). DO NOT NAIL THROUGH FLASHING CONE.
Storm Collar
Overlap Shingles Top and Sides Only
Flashing Cone
Nail Only Outer Perimeter of Flashing
Underlap Shingles at Bottom
Figure 19 - Flashing Installation
Opening "A"
Pitch Slope Opening "A"
Max.
Used Flashing
Model No.
Flat 15" V6F-8DM
0-6/12 26.6° 16 1/8" V6F-8DM
6/12- 12/12 45.0° 20 3/8" V12F-8DM
Figure 18- Roof Opening Measurements
5. Add next sections of pipe until end penetrates roof line. Check to see that proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above highest point of roof cutout. Termination and chimney must extend a minimum of 36" above highest point where it passes through the roof.
IMPORTANT: If an exposed portion of chimney is greater than 4' above roofline, use support wires to keep chimney secured. Support wires may be at­tached to outer pipe of chimney with screws provided screws do not penetrate inner flue pipe.
Installing Flashing on a Metal Roof
When installing flashing on a metal roof, it is required that putty tape be used between flashing and roof. Flashing must be secured to roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through screw holes. A roof coating must also be applied around perimeter of flashing to provide a proper seal.
STORM COLLAR INSTALLATION
Place storm collar over pipe and slide down until it is snug against open edge of flashing (see Figure 20). Use SC1 for all round termina­tions. Apply waterproof caulk around perimeter of collar to provide a proper seal.
Chimney Pipe
Waterproof Caulk
Storm Collar
Flashing
Figure 20 - Storm Collar
TERMINATIONS Standard Installation
The fireplace system must be terminated with the listed round top or chase terminations. Terminations approved for this fireplace are RLT-8DM, which can be used for flashing or chase and ETL-8DM for chase style termination only. Figure 21, page 12 shows an RLT-8DM round top termination.
Follow installation instructions provided with termination being used.
126647-01_E
Astria.us.com
11
Page 12
VENTING INSTALLATION Continued
CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions provided with the termination being used.
Attach Bracket Tabs to Outer Pipe (3 places) Secure with Screws
Overlap Shingles (Top and Sides)
Figure 21 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. Terminations must be separated a minimum of 24" center to center and stacked at a minimum vertical height difference of 18" (see Figure 22).
RLT-8DM
Caulk
Collar
Flashing
Underlap Shingles
10 FOOT RULE
All chimney terminations must extend a minimum of 3' above the highest point where it passes through the roof and must be at least 2' above roof with a 10' horizontal span (see Figure 23).
Figure 23 - 10 Foot Rule
FINISHING FIREPLACE
Combustible materials, such as wallboard, sheet rock, drywall, ply­wood, etc. may directly contact sides and top front edge at nailing flanges of fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct louvered slots or any other opening. When overlapping with a non­combustible facing material, use only noncombustible mortar or adhesive appropriate for the particular installation.
Note: If a decorative shroud is to be installed, contact the manufac­turer for specifications.
18" (458 mm)
Min. Typ.
24" (610 mm)Min.
24" (610 mm)Min.
Figure 22 - Multiple Chase Installation
12
Astria.us.com
126647-01_E
Page 13
OPTIONAL GAS LINE INSTALLATION
WARNING: A qualified service person must con-
nect fireplace to gas supply. Follow all local codes.
A gas line may be installed for the purpose of installing a vented or vent-free decorative gas appliance available through your local distributor. Use only gas piping approved by local codes. When installing a gas line, a shutoff valve designed for installation outside the appliance is recommended.
The gas pipe is intended for connection to a decorative gas ap­pliance that operates using natural or propane/LP gas only. This appliance must have an automatic shutoff device and must comply with the Standard for Decorative Gas Appliances for Installation in Vented Fireplace, ANSI Z21.60. ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED IN THIS FIREPLACE.
NOTICE: Before you proceed, make sure your gas supply is turned off.
Use only a 1/2" black iron pipe and appropriate fittings.
1. Remove knockout indentation on refractory or firebrick wall located approximately 2" above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 24).
2. Remove gas line cover plate located on rear of fireplace and pull out insulation from gas line conduit sleeve. Save insulation for reuse.
3. Run gas line into the fireplace through the rear at 11 1/4" from floor and through gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 25).
Note: Secure incoming gas line to wood framing to provide rigidity
for threaded end.
4. Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install the gas appliance or cap off gas line if desired.
If you install a decorative gas appliance (vented gas log), decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/ CGA-B149.1 National Gas And Propane Installation Code (Canada).
Outside of Fireplace
Gas Line Conduit
Insulation
Gas Conduit Cover
Outside of Fireplace
Gas Line Conduit
Repack Insulation
Figure 24 - Gas Line Knockout
Incoming 1/2" Black Iron Pipe
Seal Opening with Refractory Cement
Figure 25 - Gas Line Installation
Side Firebrick Finished Side
1/2" Dowel
Refractory Knockout Plug
Side Firebrick Finished Side
Provide Enough Threaded End for Fitting Connection
CAUTION: All gas piping and connections must be tested for leaks after installation is completed. After ensuring that gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BY A QUALIFIED SERVICE PERSON.
Note: An IHP hood must be installed when using an unvented gas log set (see Accessories on page 17).
WARNING: Do not operate an unvented gas log set in this fireplace with chimney removed.
126647-01_E
Astria.us.com
WARNING: To avoid the risk of damaging fireplace
materials and increasing the risk of spreading a fire, do not use fireplace to cook or warm food.
WARNING: If the fireplace has been used for wood burning, firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated.
WARNING: When using a decorative vented gas log, damper must be removed or permanently locked in fully open position and glass doors must be in fully open position.
13
Page 14
OPERATION AND MAINTENANCE GUIDELINES
OPEN
8 Foot
VENT-FREE GAS LOG INSTALLATION
Only unvented gas log sets that comply with the standard for un­vented room heaters, ANS Z21.11.2, can be installed in this fireplace.
Note: An appropriate IHP PRODUCTS, LLC hood (see Replacement Parts and Accessories, pages 15 and 16) must be installed when using an unvented gas log set.
WARNING: Do not operate an unvented gas log set
in this fireplace with the chimney removed.
VENTED GAS LOG INSTALLATION
Only vented decorative appliances (vented gas log sets) that comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplace, ANS Z21.1.60, can be installed in accordance with the National Fuel Gas Code, ANS Z223.1 in this fireplace.
WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position.
COLD CLIMATE INSTALLATION
The following installation procedures are recommended when install­ing a fireplace system in a cold climate area. Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space.
1. Fireplace must be placed on a solid continuous surface. Add insulation under fireplace in all cold climate areas.
2. Insulate under raised platform or cantilevered chase to reduce air infiltration.
3. Insulate walls of chase, both outer and interior partitioning wall (see Figure 26). Clearances from pipe to insulating material must be maintained.
4. Install a firestop spacer in chase at ceiling level for safety and reduction of cold air movement (see Accessories, page 16).
5. Do not insulate top of firebox. The opening in collar around chim­ney at top of firebox must mot be obstructed (see Figure 27).
6. Before finishing fireplace enclosure, inspect all joints of outer firebox. Seal any gaps of outer firebox with noncombustible material. Caulk any gaps between nailing flange and framing.
Chimney Termination
Level
Solid Continuous Surface
FIREPLACE STARTER COLLAR
Flashing
Chimney Sections
Insulate Outside Walls of Chase
Thermal Barrier
Outside Base
Figure 26 - Cold Climate Installation
KEEP THIS AREA
Joist -
Insulate
Same as
Ceiling
Solid Surface
Firestop Spacer
Figure 27 - Fireplace Collar Opening
14
Astria.us.com
126647-01_E
Page 15
OPERATION AND MAINTENANCE GUIDELINES Continued
GLASS DOORS
Bi-fold glass doors are optional with this fireplace. Check with your local distributor for availability.
To install glass doors, refer to installation instructions that are in­cluded with kit. When fireplace is in operation, doors must be fully open or fully closed position only or a fire hazard may be created (see Figure 28).
A fireplace equipped with glass doors operates much differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within the fireplace can result if too large a fire is built or if combustion air gate is not completely open.
IMPORTANT: The following tips should be used to assure that both fireplace and glass door retain their beauty and function properly.
Both the flue damper and glass doors must be fully opened before starting a fire. This will provide sufficient combustion air and maintain safe temperatures in firebox.
The glass must be allowed to warm slowly and evenly. The tem­pered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes. Always keep the fire well back from the doors and never allow flames to contact the glass.
Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from the fire. To remove doors, refer to instructions included with glass door kit.
GRATE
The grate is designed to provide you with the maximum solid fuel capacity. Do not overload grate or obstruct required air space beneath it. Always keep ashes from building up under grate.
WARNING: Risk of fire! Replace grate made for use with this fireplace only. See Fireplace Acces- sories, page 16.
CHIMNEY
Have your chimney system cleaned and inspected regularly to ensure safe and efficient operation.
For further operating guidelines, instructions and warranty informa­tion, please refer to your homeowner's guide or contact your dealer.
WARNING: FIREPLACES EQUIPPED WITH DOORS SHOULD BE OPERATED ONLY WITH DOORS FULLY OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE FIREPLACE OPENING, CREATING RISKS OF BOTH FIRE AND SMOKE.
WARNING: Discontinue use of the appliance immediately if doors are damaged and contact a qualified installer for repair. Only doors certified with the appliance shall be used.
WARNING: Do not slam or strike doors. Damage can result in a hazardous condition.
Doors Fully Closed
Fireplace Front
REPLACEMENT PARTS
See Page 16 Fireplace Accessories section, for replacement parts. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.
2. The serial number of the fireplace.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the installation or application of this fireplace, please contact your dealer.
IHP 1769 East Lawrence Street Russellville, AL 35654 Visit us at Astria.us.com
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. Please contact your IHP dealer for any questions or concerns. When contacting your dealer please have your model and serial numbers of your fireplace ready. You can also visit our web site at Astria.us.com.
126647-01_E
Doors Fully Opened
Fireplace Front
Figure 28- Glass Doors
Astria.us.com
15
Page 16
CAT NO. MODEL DESCRIPTION
REFRACTORY (36" Left Side Shown)
FIREPLACE ACCESSORIES
J7010
J7011
J6908
J6909
J4518
J4519
J7653
J4956
J6928
J6906
Refractory, Back 36L/R/LS/RS
Refractory, Side 36L/R/LS/RS
Refractory, Bottom 36L
Refractory, Bottom 36R
GRATE
Grate 36" L 36LGR
Grate 36" R 36RGR
SCREEN ASSEMBLY
Screen 23X21
Nut Push-On.765X.445X.011 Black
Rod, Screen 36L/R/LS/RS
EMBER PROTECTOR
Protector, Ember EP 36
INSTALLATION ACCESSORIES
BI-FOLD GLASS DOORS
F1023 VDBP36C Glass Door Wb Corner, Black
J2723 VDG36C Kit,Bi-Fold Glass Door,Brushed
(Not Shown)
F1024 DC36L/R/LS/RS Glass Door, Platinum
DOUBLE WALL PIPE
F0895 12-8DM 12" Section Double Wall Pipe Snap Lock
F0896 18-8DM 18" Section Double Wall Pipe Snap Lock
F0897 24-8DM 24" Section Double Wall Pipe Snap Lock
F0898 36-8DM 36" Section Double Wall Pipe Snap Lock
F0899 48-8DM 48" Section Double Wall Pipe Snap Lock
30° OFFSET AND RETURN
F0900 30E-8DM 30 Degree Offset and Return
F0886 30E-8HT 30 Degree Hi-Temp Offset and Return
CHIMNEY SUPPORT
12S-10DM Chimney Support
OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION
F1091 AK4 Complete Outside Air Kit w/Collars Hood & 3' Flex
OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION
F1093 AK4F Outside Air Kit Collar, Hood & 3' Flex for Floor Venting
STORM COLLAR
F0915 SC1-1 Storm Collar (1 ea.)
16
Astria.us.com
126647-01_E
Page 17
INSTALLATION ACCESSORIES Continued
900599-01
FIRESTOP SPACER
F0907 3600FS-8DM-1 1" Clearance Firestop Spacer ( 1ea.)
F0904 FS-8DM 2" Clearance Firestop Spacer (1 ea.)
ROOF FLASHING
F0909 V6F-8DM Roof Flashing 0 to 6/12 Pitch (30" Base)
F0910 V12F-8DM Roof Flashing 6/12 to12/12 Pitch
ANTI-DRAFT SHIELD (Round Top Termination Only)
F0927 ADS-8DM Anti-Draft Shield for Round Top Only
ROUND TOP TERMINATIONS WITH LOUVERS
F0918 RLT-8DM Round Top with Louvered Screen
F0890 RLT-8HT Hi-Temp Round Top with Louvered Screen
ROUND TOP TERMINATIONS WITH LOUVERS W/SLIP SECTION
F0919 RLTT-8DM Round Top with Slip Section & Louvers
F0891 RLTT-8HT Hi-Temp Round Top w/Lvrd. Screen and Slip Section
SQUARE TOP TERMINATION WITH LOUVERS
F0920 ET-8DM Square Top
F0892 ET-8HT Hi-Temp Pyramid Top with Slip Section
SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION
F0921 ETL-8DM Square Top with Slip Section
F0893 ETL-8HT Hi-Temp Large Pyramid Top with Slip Section
MESH SQUARE TOP TERMINATION
F0922 ETO-8DM Square Top with Mesh
MESH SQUARE TOP TERMINATION WITH SLIP SECTION
F0923 ETLO-8DM Square Top with Mesh and Slip Section
ADJUSTABLE HOOD
Required when installing a vent-free gas log in this fireplace.
F1764 GA6050 Black Fireplace Hood
FAN KIT
F1087 VCBK4R 2-Fan Kit Corners Only
F1088 VCBK4L 2-Fan Kit Corners only
FIRESTOP THIMBLE
F0911 38FST Firestop Thimble ( Use when penetrating a joist)
F0912 FST30 Firestop Thimble ( Use when offsetting through a joist)
HIGHT TEMPERATURE TOUCH-UP PAINT
J3943 Kit Touch-Up paint
LABEL-UL127-50PK
F2659
126647-01_E
LABEL-UL127-
50PK
UL127 Venting Label - 50 PK
Astria.us.com
(Not Shown)
WARNING HOT
•Fire Risk
•Insulation and combustibles must not touch
pipe
•Consult manual for clearance requirements
•Ensure proper connection
WARNING HOT
•Fire Risk
•Insulation and combustibles must not touch
pipe
•Consult manual for clearance requirements
•Ensure proper connection
WARNING HOT
•Fire Risk
•Insulation and combustibles must not touch
pipe
•Consult manual for clearance requirements
•Ensure proper connection
17
Page 18
IMPORTANT NOTICES
Canadian code CAN/ULC-S610-M87 and other pertinent codes require stainless steel chimney for the installation of this fireplace. A Cold Air Climate Kit is also required in Canada and is recommended for cooler regions in the United States. Below, find a list of approved stainless steel parts.
Chimney Parts List for Canada
Catalog No.
F0881 12-8HT 12" Section Hi-Temp Double
F0882 18-8HT 18" Section Hi-Temp Double
F0883 24-8HT 24" Section Hi-Temp Double
F0884 36-8HT 36" Section Hi-Temp Double
F0885 48-8HT 48" Section Hi-Temp Double
F0886 30E-8HT 30 Degree Hi-Temp Offset
F0887 12S-8HT Hi-Temp Chimney Support
F0888 RT-8HT Hi-Temp Round Top with
F0889 RTT-8HT Hi-Temp Round Top with
F0890 RLT-8HT Hi-Temp Round Top with
F0891 RLTT-8HT Hi-Temp Round Top with
F0892 ET-8HT Hi-Temp Pyramid Top with
F0893 ETL-8HT Hi-Temp Large Pyramid Top
F0894 AP-8HT Hi-Temp Anchor Plate/Col-
F0929 CAK-8 Cold Air Collar Kit - 8"
*When ordered alone, this part cannot ship via parcel delivery services.
Model No.
8" Hi-Temp Wood burning Chimney
Wall Pipe Snap Lock
Wall Pipe Snap Lock
Wall Pipe Snap Lock
Wall Pipe Snap Lock
Wall Pipe Snap Lock
and Return
(For Use With Chimney Heights In Excess of 30')
Mesh Screen
Mesh Screen and Slip Sec­tion
Louvered Screen
Louvered Screen and Slip Section
Slip Section
with Slip Section (use with all 8" systems)
lar Assembly (for masonry fireplaces)
Chimney
IMPORTANT NOTICE A manufactured shroud which has been approved by a na­tional testing agency for use with this fireplace may be used if installed in accordance with the instructions by its manu­facturer. A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit (SLK) in accordance with instructions provided with the shroud.
NOTICE: The firebox canopy (hood) must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater.
CAUTION: THE STRUCTURAL INTEG­RITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
WARNING: DO NOT INSTALL
IN SLEEPING ROOM OF MOBILE HOMES.
18
Astria.us.com
126647-01_E
Page 19
APPENDIX A
Draft Requirements
Your wood-burning appliance is dependent upon a properly func­tioning chimney for optimum performance. It is important to match the wood-burning appliance to the chimney. The chimney has two functions:
1. It draws combustion air into the appliance (without air, no fuel will burn) and
2. It exhausts combustion by-products. Your new appliance is what is known as a “natural draft” appliance.
The appliance depends solely on the natural draft of the chimney system to draw combustion air into the unit. Draft is the force that moves air from the appliance up into the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance (overfiring). Slow or inadequate draft equals poor combustion and possible smoking problems. The following are some conditions that may contribute to poor chimney draft:
1. A chimney too large for your appliance.
2. A chimney with not enough height to produce adequate draft.
3. A chimney with excessive height (this may allow exhaust to cool too much before exiting, which will stall the rate the exhaust exits).
4. Offsets in the venting system are too restrictive (see Chimney Guidelines).
Inadequate draft will cause the appliance to leak smoke into the room through the wood-burning appliance and the chimney connector joints. Excessive draft may cause an uncontrollable burn or a glowing red appliance or chimney part. Overfiring Damage - If the appliance or chimney connector glows, you are overfiring. Other symptoms may include: Cracking, warping or burning out of components, plated accessories may turn color, appliance glass may develop a haze, which will not come off with cleaning.
Overfiring of a appliance is a condition where excessive tempera­tures are reached, beyond the design capabilities of the appliance. The damage that occurs from overfiring is not covered under the manufacturer’s limited warranty.
Also see Troubleshooting on Page 20.
WARNING
Neither the manufacturer nor the seller warrants “smoke free” operation nor are we responsible for inadequate system draft caused by mechanical systems, general construction conditions, inadequate chimney heights, adverse wind conditions and/or unusual environmental factors or conditions beyond our control.
Selecting the Proper Venting System
The appliance is merely one component of a larger system. The other equally important component is the venting system. This is necessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion by products from the appliance.
If the venting system’s design does not promote these ends, the system may not function properly. Poorly functioning venting systems may create performance problems as well as be a safety hazard. A draft
test should read greater than .04’ W.C. (inches water column) and less than .08” W.C. As per NFPA-211 standard, the installer must
126647-01_E
Astria.us.com
take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance. See Chimney Guidelines to assist you in selecting the proper venting system for your installation.
American National Standards Institute ANSI/NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli­ances - See Draft Section: A chimney or vent shall be so designed
and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere. The venting system shall satisfy the draft requirements of the connected appliance in accordance with the manufacturer’s instructions.
Chimney Guidelines:
• Most wood-burning appliances requires approximately 12 feet minimum of “effective draw” provided by the venting system. As a rule of thumb, every 90 degree total direction change in the venting will result in a loss of approximately 5 feet of “effective draw.” Example: If two 45 degree offsets are used, subtract 5 feet from the actual vertical vent height to determine your “effective draw.” In this case if you had 14 feet of vertical vent, the effective draw would only be approximately 9 feet (14 ft. - 5 ft. = 9 ft.), therefore it may be necessary to add additional height to the venting system.
• Do not install an offset within the first two feet above the flue outlet on the appliance.
• In well insulated and weather tight homes, it may be difficult to establish a good draft up your chimney. The poor draft is caused by a shortage of air in the house. In this situation an Outside Air Kit may need to be installed (See Negative Pressure Warning be­low and Outside Combustion Air in the Installation and Operation manual).
Negative Pressure Warning
These appliances are not designed to be operated in a negative pressure. In very airtight homes with large kitchen exhaust fans, furnace cold air returns, fresh air exchange systems and any other air system in close proximity to the heating appliance may create a negative pressure in the same room as the heating appliance. This can create dangerous back drafting of the appliance and chimney joints, drawing combustion by-products into the home. Be sure your home has adequate makeup air to eliminate negative pressures caused by the above-mentioned sources. Outside air connected to the appliance probably will not resolve such a problem as the appliance is not the source of negative pressure. IHP accepts no liability for damages resulting from negative pressures described here.
Ventilation Requirements - Provide adequate air for combustion. The fresh air requirements of this appliance must be met within the space where it will be installed. Ventilation is essential when using a solid-fuel-burning appliance. In well insulated and weather tight homes, it may be difficult to establish a good draft up the chimney (caused by a shortage of air in the home). The lack of air is caused by many common household appliances which exhaust air from the home (such as a furnace, heat pump, air conditioner, clothes dryer, exhaust fans, fireplaces, and other fuel burning appliances). Also, the combustion process of this appliance uses oxygen from inside the dwelling. If the available fresh air delivery in the dwelling is insufficient to support the demands of these appliances, problems can result (i.e. excessive negative pressure can develop in the dwelling which will affect the rate at which this appliance can draft thus resulting in performance problems or smoking. To correct this problem it may help to open a window (preferably on the windward side of the house) or install an outside air kit.
19
Page 20
APPENDIX A Continued
Smoking – Causes And Troubleshooting
To reduce the likelihood of smoking when opening the door, open the combustion air control or damper before opening the door. Your appliance has been designed and tested to provide smoke free operation. Occasionally, there may be a small amount of smoking upon lighting the fire, until the chimney heats up but this should not continue. If the appliance continues to smoke it is probably for one of the following reasons:
A. Negative pressure in the house -
As the fire burns, air goes up the chimney. This air must be
replaced through leakage into the house or through the outside air duct. When operating the appliance, open a nearby window temporarily to check if there is adequate replacement air supply.
B. Blowers operating (e.g.: range hood) - These blowers draw
air out of the house and may actually cause a negative pressure in the house. Turn off all blowers and open a nearby window to determine if this is the cause of the problem.
C. Wet wood - Wet or tarred wood will smoulder and smoke instead
of burning properly. have properly seasoned wood for burning.
D. Dirty or blocked chimney - Check to make sure the chimney is
clear and clean. a properly sized chimney brush to clean.
E. Chimney not long enough - The minimum chimney height is
twelve (12) feet (3.7 m) not including the appliance height. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any roof or wall within ten (10) feet (3 m) of it. When installed with offsets, the minimum chimney height is fifteen (15) feet. Additional height will increase draft and will decrease the tendency to smoke.
F. Poor chimney draft - With no fire, there should be sufficient draft
to exhaust cigarette smoke introduced under the baffle or flue baffle. Chimneys installed against an outside wall without protection may generate back draft problems which will cause start-up problems. To prevent this, open a nearby window, roll up a piece of paper and light it. Then, hold it in the upper part of the firebox to warm up the chimney. Wait until the draft is sufficient, then start the fire.
G. Blower for forced air kit operating (some models) - Make
sure that the blower is in the “off” position when you open the appliance door for reloading.
Locating The Appliance
The best location to install your appliance is determined by consid­ering the location of windows, doors, and the traffic flow in the room where the appliance is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the hot air ducts (some models), outside air kit and chimney. If possible, you should choose a location where the chimney will pass through the house without cutting floor or roof joists.
When selecting the location, the chimney outlet position and the direction of the wind are important factor affecting the chimney per­formance. To allow a maximum draft and to reduce wind turbulence, the chimney must:
• Penetrate the highest part of the roof.
• Be installed as far as possible of roof offsets, trees or any other obstructions that may cause wind turbulence and back drafts in the chimney.
• The least amount of offsets (elbows) possible. NOTE: A maximum of 2 offsets is allowed.
Your dealer can help you determine if you
If dirty call a certified chimney sweep or use
Location Recommended
Marginal Location
Wind Direction
Tree
Location
Recommended
Outside Air Intake Facing the Wind
Figure 1
Not
Location Not Recommended
Prohibited Fuels
These appliances are designed to burn natural well-seasoned wood. The wood fuel should be air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. Burning artificial logs, in some model appliances is allowed (see Installation and Op­eration manual); please read and follow the instructions provided by the manufacturer. DO NOT BURN:
• Garbage;
• Lawn clippings or yard waste;
• Materials containing rubber, including tires;
• Materials containing plastic;
• Waste petroleum products, paints or paint thinners, or asphalt products;
• Materials containing asbestos;
• Construction or demolition debris;
• Railroad ties or pres­sure-treated wood; woods that have been dipped in tar, pitch, pine tar, creosote, etc.
• Manure or animal remains;
• Salt water driftwood or other previously salt water saturated materials;
• Unseasoned wood;
• Christmas tree branches;
• Paper products, colored paper, cardboard, plywood, or particleboard;
• Gasoline;
• Naphtha;
• Engine Oil;
• Flammable Liquids;
• Solvents;
• Grease; or
• Charcoal or Coal
NOTE: The use of a firewood moisture meter is recommended to ensure the firewood contains less than 20% moisture.
Seasoning Guide
Softwoods - 6 months to 18 months Hardwoods - 12 months to 24 months
Logs that are 5” diameter across or larger should be split in half, three pieces if over 8 inches, and four pieces when over a foot across. If a tree has been dead for 2 - 4 years it still needs to be cut, split, and seasoned for 6 to 24 months depending on the wood.
Standard Cord of Wood
4 Ft.
(1.2M)
4 Ft. (1.2M)
4'
4'
Figure 2
8 Ft.
8'
(2.4M)
20
Astria.us.com
126647-01_E
Page 21
NOTES
______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
126647-01_E
Astria.us.com
21
Page 22
NOTES
______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
22
Astria.us.com
126647-01_E
Page 23
Innovative Hearth Products
®
Astria
Brand Wood-Burning Fireplace
20 Year Limited Warranty
THE WARRANTY
Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Astria® brand wood burning fireplace ("Product") to be free from defects in materials and work­manship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 Year Limited Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components, paint and applied stains are excluded from this 20 Year Limited Warranty. The following do not carry a 20 Year Limited Warranty but are warranted as follows:
Air tubes, baffles and brick retainers – Repair or replacement for one year from the date of installation Cast iron parts – Replacement for one year from date of installation Electrical components – Repair or replacement for one year from the date of installation Fireplace screens, refractory and side shields (metal or refractory) – Repair or replacement for two years from date of installation. Excludes hairline cracks. Fuel grates –These parts are considered consumable accessories and therefore are not warranted, with the exception of defects in material or workmanship which
are covered for 90 days from the date of installation
Gaskets – Replacement for one year from date of installation Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing Optional glass doors – Repair or replacement for 90 days from the date of installation
Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component. Parts not otherwise listed carry a 90 day warranty from the date of installation. Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation Manual provided with the product. This includes burning such fireplace fuels as wood and natural or propane gas. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
Coverage of this 20 Year Limited Warranty is conditional upon use of an adequate fuel grate on factory-built fireplaces only, when applicable.
IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi­tions which may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with Security Chimneys International, Ltd. or IHP chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this 20 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without first obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.ASTRIA.US.COM.
Printed in U.S.A. © 2013 Innovative Hearth Products
126647-01_E
P/N 900202-00, Rev. B 02/2018
Astria.us.com
Innovative Hearth Products 1769 East Lawrence Street • Russellville, AL 35654
23
Page 24
Astria.us.com
Record the following important information about your fireplace:
Fireplace model number
Fireplace serial number
Date fireplace was Installed
Dealer name
Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2013 Innovative Hearth Products LLC
P/N 126647-01 Rev. E 02/2018
1769 East Lawrence Street • Russellville, AL 35654
Loading...