Astria Fireplaces Atlas36ZP2, Atlas42ZP3, Atlas36ZP3, Atlas42ZP2 Installation And Operation Instructions Manual

Page 1
INSTALLATION AND
OPERATION INSTRUCTIONS
UNIVERSAL VENT-FREE FIREBOX
36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes P/N 900238-00 REV. C 09/2018
MODELS
Atlas42ZP2 Shown
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
In the Commonwealth of Massachusetts:
Installation must be performed by a licensed plumber or
gas fitter;
• See Table of Contents for location of additional Common­wealth of Massachusetts requirements.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY: Do not store or use gasoline or other flammables or liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Report No. F14-168
Atlas36ZP2 Atlas36ZP3
Atlas42ZP2 Atlas42ZP3
FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
WARNING: IMPROPER INSTALLATION, ADJUST­MENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALI­FIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATIONS.
THIS IS A VENT-FREE GAS-FIRED HEATER ENCLO­SURE. IT USES AIR (OXYGEN) FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED. REFER TO COMBUSTION AND VENTILATION AIR SECTION, PAGES 3 & 4.
Due to high temperatures, the appliance should be located out of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM HEATERS.
Page 2
IMPORTANT SAFETY INFORMATION
INSTALLER: PLEASE LEAVE THESE INSTRUC­TIONS WITH THE OWNER.
OWNER: PLEASE RETAIN THESE INSTRUC­TIONS FOR FUTURE REFERENCE.
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing prop­erty damage, personal injury or loss of life.
IMPORTANT
The fireplace screens on the appli­ance must be closed prior to operat­ing the fireplace.
WARNING
These built-in vent-free fireboxes have only been tested and approved for use with ANSI Z21.11.2 Vent­free gas logs.
WARNING
Do not attempt to burn solid wood fuels, other gas log sets or any other combustible materials in this vent-free firebox.
WARNING
Any change to this Vent-Free room heater can be dangerous. Improper installation or use of this heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
WARNING
Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
2
WARNING
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with head­aches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the Vent-Free Gas Heater serviced as it may not be operating correctly.
WARNINGS
• Due to high temperatures, the firebox should be located out of traffic and away from furniture and draperies.
• Do not place clothing or other flammable material on or near the heater.
• Any safety screen or guard re­moved for servicing the firebox must be replaced and/or closed prior to operating the heater.
• Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpet­ing, bedding material, etc. It is important that control compart­ments, burners and circulating air passageways of the heater be kept clean.
• Allow the heater to cool before servicing. Always shut off any electricity or gas to the heater while performing service work.
• Do not install the firebox in a sleeping room or bathroom.
• The appliance and its individual shut-off valve must be discon­nected from the gas supply piping system while performing any tests of the gas supply piping system at test pressures equal to or less than 1/2 psig.
• Children and adults should be alerted to the hazard of high sur­face temperature and should stay away to avoid burns or clothing ignition.
WARNING
• The heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pres­sure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
• Keep heater area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
• Do not use this heater if any part has been under water. Im­mediately call a qualified service technician to inspect the heater and to replace any part of the con­trol system and any gas control which has been under water.
• Ensure that the heater is clean when operating. Excessive dust accumulation on the burner and logs will increase the amount of carbon monoxide formation and could lead to carbon monoxide poisoning and death.
IMPORTANT
Before starting your firebox instal­lation, read these installation instructions carefully to be sure you understand them completely and in entirety. Failure to follow these instructions could cause a heater malfunction resulting in serious injury and/or property damage.
WARNING
Do not install in the vicinity where gasoline or other flammable liq­uids may be stored. The Vent-Free firebox must be kept clear and free from these combustible materials.
WARNING
Maintain minimum clearances.
Page 3
CONGRATULATIONS!
Misc. Codes / Standards -
In selecting this Astria® Vent-Free Gas Firebox you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace. Welcome to a family of tens of thousands of satisfied Astria Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your Astria product.
TABLE OF CONTENTS
Important Safety Information ........... Page 2
Packaging List .................................. Page 3
General Information ......................... Page 3
Burn-in Period .................................. Page 3
Tools/Building Supplies ....................Page 3
Codes ............................................... Page 3
Combustion And Ventilation Air ....... Page 4
Cold Climate Insulation .................... Page 5
Requirements for the Commonwealth of Massachusetts Page 5
Location Of Firebox .......................... Page 6
Clearances ....................................... Page 6
Assembly Steps ............................... Page 8
Gas Line Installation ......................... Page 8
Firebox Framing ............................... Page 9
Firebox Installation ........................... Page 9
Specifications ................................... Page 10
Framing Specifications ..................... Page 11
Hood Installation .............................. Page 11
Optional Equipment / Blower Kit
Installation .................................. Page 12
Firebox Finishes ............................... Page 15
Accessories/components ................. Page 15
Replacement Parts List .................... Page 1 7
Warranty .......................................... Page 19
This installation manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system.
GENERAL INFORMATION
These Vent-Free firebox enclosures are designed to accept all ANSI Z21.11.2 approved Decorative Type Vent-Free Gas Log Room Heaters. For the
appropriate Vent-Free Gas Log Room Heater model, refer to Page 16 (see
Sets)
. Refer to the installation instructions pro-
vided with the log sets for detailed instructions.
This installation manual along with the vent-free gas log installation manual will enable you to obtain a safe, efficient and dependable instal­lation of your room heater system.
Do not alter or modify the firebox or its com ponents under any circumstances. Any modification or alteration of the firebox system, including but not limited to the firebox and ac­cessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
These Built-In Vent-Free Fireboxes have been tested and approved as Ventless Firebox Enclo­sures for Gas-Fired Unvented Decorative Room Heaters to ANSI Z21.91.
Vent-Free Gas Log
Burn-in Period
The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
The appliance, when installed, must be electri­cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition.
Check the packaging list to be sure that you have all the necessary parts in usable condition. Also check for concealed damage.
Tools and Building Supplies Normally Required
Tools Should Include:
• Phillips screwdriver
• Hammer
• Saw and/or sabersaw
• Level
• Measuring tape
• Electric drill and bits
• Pliers
• Square
• Piping complying with local codes
• Pipe wrench
• Tee joint
• Pipe compound
Building Supplies Should Include:
• Framing materials
• Wall finishing materials
• Caulking materials
• Fireplace surround materials
(noncombustible)
• Insulation (for packing around gas-line penetration holes)
(noncombustible)
Codes
PLEASE READ AND UNDERSTAND
THESE INSTRUCTIONS BEFORE BEGIN-
NING YOUR INSTALLATION.
Packaging List
Vent-Free Gas Firebox
(optional for models Atlas36ZP2, Atlas36ZP3,
Hood
Atlas42ZP2 and Atlas42ZP3)
Installation and Operation Instructions
During the first few times of operation of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. We recom­mend that you open windows and ventilate the house during the initial burns. The paint emits non-toxic odors during this process.
Depending on your use, the burn-in period may take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD. THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
If an optional blower is installed, Do not turn it on during the Burn-In period.
Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223.1 or NFPA 54 - latest edition which can be obtained from The American National Standards Institute, Inc. (25 West 43rd Street, 4th floor New York, NY 10036) or National Fire Protection Association, Inc. (1 Batterymarch Park Quincy, MA 02169-7471).
3
Page 4
COMBUSTION AND VENTILATION AIR
WARNING
Heaters installed in these appli­ances shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes. Read the following instruc­tions to ensure proper fresh air for this and other fuel-burning appli­ances in your home.
Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Homeowners apply weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, homeowners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap­pliances need fresh air for proper combustion and ventilation.
Exhaust fans, some fireplaces, clothes dryers and some fuel-burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will ensure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Com­bustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space The information on Pages 8 through 10 will help
you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un­usually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the outside
atmosphere have a continuous water vapor retarder with a rating of one perm
-11
(6 x 10 openings gasketed or sealed and
b. weather stripping has been added on
4
openable windows and doors and
kg per pa-sec-m2) or less with
c. caulking or sealants are applied to areas
such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumb­ing, electrical and gas lines and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, in the In stallation and Operation manual for the heater.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Firebox Location.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/ NFPA54 allows two methods for determining
whether the space in which the heater is being installed is confined or unconfined space. The standard method defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms com­municating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.
Where the air infiltration rate of a structure is known, the Known Air Infiltration Rate Method may be used. Follow The National Fuel Gas Code, ANSI Z223.1/NFPA 54 to use this method to determine if the space is confined or unconfined.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
3
per kw)
DETERMINING FRESH-AIR FLOW FOR Heater LOCATION
Determining if You Have a Confined or Unconfined Space Using the Standard Method
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =__________cu.
ft. (volume of space)
Example
ft. (width) x 8 ft. (ceiling height) = 3,168 cu. ft. (volume of space)
If additional ventilation to adjoining room
is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum BTU/Hr the space can support.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
: Space size 22 ft. (length) x 18
________ (volume of space) x 20 = (Maxi-
mum BTU/Hr the space can support)
Example
20 = 63,360 (maximum BTU/Hr space can support)
3. Add the BTU/Hr of all fuel burning appli ances in the space.
Vent-free fireplace ________ BTU/Hr Gas water heater* ________ BTU/Hr Gas furnace ________ BTU/Hr
-
Vented gas heater ________ BTU/Hr Gas fireplace logs ________ BTU/Hr Other gas appliances* + _______ BTU/Hr Total = ________ BTU/Hr * Do not include direct-vent gas appli
ances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example: Gas water heater Vent-free fireplace + Total =
4. Compare the maximum BTU/Hr the space can support with the actual amount of BTU/ Hr used.
_______ BTU/Hr (maximum the space can support) _______ BTU/Hr (actual amount of BTU/Hr used)
Example
79,000 BTU/Hr (actual amount
The space in the example is a confined space because the actual BTU/Hr used is more than the maximum BTU/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space
of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air
From Inside Building
Operation manual for the heater
B. Vent room directly to the outdoors. See
Ventilation Air From Outdoors, lation and Operation manual for the heater
C. Install a lower BTU/Hr appliance, if lower
BTU/Hr size makes room unconfined.
If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.
: 3,168 cu. ft. (volume of space) x
40,000 39,000 79,000
: 63,360 BTU/Hr (maximum the
space can support)
of BTU/Hr used)
,
in the Installation and
WARNING
If the area in which the heater may be operated does not meet the required volume for indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in the National Fuel gas Code, ANSI Z223.1/NFPA 54, the Inter­national Fuel gas Code, or applicable local codes.
-
-
BTU/Hr BTU/Hr BTU/Hr
.
in the Instal-
.
Page 5
COLD CLIMATE INSULATION
Not to Scale
For cold climate installations, seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside cavities between studs and under floor on which the appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fiberglass insulation. If the fireplace is being installed on a cement slab, in cold climates, a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room. It also helps to for maximum air tightness and caulk firestops.
sheetrock inside surfaces and tape
LOCATION OF FIREBOX
Carefully select the best location for installation of your built-in Vent-Free firebox. The following factors should be taken into consideration:
Clearance to side wall, ceiling, woodwork
and windows.
Location must not be affected by drafts
caused by kitchen exhaust fans, return air registers for forced air furnaces/air condi­tioners, windows or doors.
Installation must provide adequate ventila-
tion and combustion air.
Do not install this firebox in a sleeping room
or bathroom.
WARNING
Do not install these built-in Vent­Free fireboxes in sleeping quarters, or in recreational vehicles.
WARNING
Do not install these appliances:
Where curtains, furniture, cloth-
ing or other flammable objects are less than 42" from the front of the Vent-Free room heater.
In high traffic areas.
In windy or drafty areas.
NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Requirements for the Commonwealth of Massachusetts
These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
• Installation and repair must be done by a plumber or gas fitter licensed in the Com­monwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
• Unvented appliances may NOT be installed in bedrooms or bathrooms.
Location should be out of high traffic areas
and away from furniture and draperies due to heat from firebox.
• Never obstruct the front opening of the Vent-Free firebox or restrict the flow of combustion and ventilation air.
• Minimize modifications to existing construc­tion. See Figure 1 for location suggestions.
CAUTION
Do not install in the vicinity where gasoline or other flammable liq­uids may be stored. The Vent-Free firebox must be kept clear and free from these combustible materials.
WARNING
Do not use a blower insert, heat exchanger insert or other acces­sory not approved for use with this appliance.
Figure 1
• A working smoke detector must be installed in the area where vent-free appliances are installed.
Seller of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
WARNING
FIRE, EXPLOSION, AND ASPHYXI­ATION HAZARD Improper adjustment, alteration, service, maintenance, or instal­lation of this heater or its controls can cause death or serious injury. Read and follow instructions and precautions in User’s Information Manual provided with this heater.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
5
Page 6
Opening
Non-Combustible Material
(shaded area
45°
Clearances
Ensure the minimum clearances shown in Figures 2 through 6 are maintained. Left and right clearances are determined when facing the front of the firebox.
Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may create a fire hazard.
Combustible Side Clearances: Clearances from the side of the firebox opening to any combustible material (e.g. side wall, mantel leg, bookshelf, etc.), must comply with the requirements shown in Figures 2 and 2a.
Example: If the mantel leg, bookshelf or other combustible material protrudes 5" from the plane of the wall where the firebox is installed, the combustible material must be a minimum of 6" from the side of the firebox opening (see Figure 2a).
40"
16"
Ceiling clearance: The ceiling must be at least 40" from the top of the firebox opening (Figure 2).
Noncombustible material: Noncombustible materials, such as slate and marble, must be at least 1/2" thick and may be used without restriction above the firebox opening, to the sides or as a hearth extension, so long as they do not obstruct vent openings for heat circulating models.
NOTE: To avoid heat-related finish damage, we recommend the use of high temperature paint (rated 175° F or higher) on the hood and the underside of the mantel.
Combustible Wall Clearance
Above Appliance (all models)
Finished Wall
Header
Top Stand-
Off Spacer
3" Min.
(on appliance)
)
Top of Appliance
Optional Hearth Extension
Figure 2
Example
Top View
3”**
* Minimum 16” from Side Wall **No combustible material may be closer than 3” from the fireplace opening.
5”
4”
7”
10”
6”
8”
Figure 2a - Minimum Side Clearances to Combustibles
12”
14”
16”*
13”
11”
9”
7”
6”
5”
4”
3”
2”
Shown with Hood Installed
Fireplace
Figure 3
Maintain adequate clearances around air openings.
Maintain adequate clearances for accessibility for purposes of servicing and proper operation.
6
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 7
Safe Zone
Example
Combustible Mantel and Trim Clearance
Models Atlas36ZP2 and Atlas42ZP2 WITH Hood Installed
Hood is optional on these models
Combustible Mantel
and Trim
16”
15”
14”
13”
12”
11”
10”
9-1/2”
Example
Top of Firebox Opening
EXAMPLE: If you choose to install a mantel that projects 4", you will need to install it
s
so that the bottom of the mantel and trim is approximately 13" or more above Firebox opening (see coordinate in shaded area above).
6”
5”
Coordinate
in ()Example
3”
4”
2”
Example
Hood
Combustible Material (wall)
Header
Top Spacer on Appliance
Non-Combustible Material 3” Min.
Top of Appliance
Screen
Noncombustible material (minimum requirements) with wood mantel or other combustible projections: To install the firebox with a wood
mantel, shelf or other combustible projection above firebox opening. Refer to Figures 4 and 5.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc., above the appliance.
WARNING
The hood must be in place to be in compliance with the clearances specified in Figures 4 and 5. Do not remove or replace hood, only use hood supplied or offered for these fireboxes (see Pages 16 and 17). Do not use any hood which may be provided with the decorative type Vent-Free room heater.
If your mantel profile is unsafe, you may either:
• Raise the mantel to an acceptable height, or
• Remove the mantel.
Floor clearance: These fireplaces may sit directly on a combustible surface.
The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However,
Figure 4
Combustible Mantel and Trim Clearance
Models Atlas36ZP2 and Atlas42ZP2 WITHOUT Hood Installed
Hood is optional on these models
Safe Zone
Combustible Mantel
and Trim
24”
23”
22”
21”
20”
19”
18”
17”
16”
s
8”
9”
10”
Top of Firebox Opening
s
7”
Coordinate
in (s)Example
6”
s
Example
Combustible Material (wall)
Header
Top Spacer on Appliance
Non-Combustible Material 3” Min.
Top of Appliance
Screen
if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom surface must be used.
EXAMPLE: If you choose to install a mantel that projects 7", you will need to install it
s
so that the bottom of the mantel and trim is approximately 18" or more above Firebox opening (see coordinate in shaded area above).
Figure 5
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
7
Page 8
ASSEMBLY STEPS
NOTES:
• Illustrations shown in this manual reflect “typical” installations with nominal dimen­sions and are for design and framing refer­ence only. Actual installations may vary due to individual design preferences. However, always maintain minimum clearances to combustible materials and do not violate any specific installation requirements. Refer to the Framing Specifications Figure
on Page 11.
10
• The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence.
Step 1. Position firebox prior to framing or into prepared framing.
Step 2. Field wire the main power supply to the appliance if a blower kit is to be installed (at the time of installation or a later date).
An optional junction box kit and blower kit is re­quired (see Page 15 Follow the installation and wiring instructions on Pages 12 through 14). Electrical connections should only be performed by an experienced, licensed/certified tradesman.
Step 3. Plumb gas line. (Gas connections should only be performed by an experienced, licensed/certified tradesman).
Step 4. Install decorative type Vent-Free room heater per the instructions provided with the Vent-Free room heater.
Step 5. Complete finish wall material, sur round and optional hearth extension to your individual taste.
for ordering information).
s 8 through
INSTALLATION
Gas Line Installation
CAUTION
Plumbing connections should only be performed by a qualified, licensed plumber. Main gas supply must be off when plumbing gas line to fireplace or performing service.
Consult all local codes.
Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFPA 54 - latest edition (USA) or B149 - latest edition (Canada). Never use galvanized or plastic pipe. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. We recommend that a qualified individual such as a plumber or gas fitter be hired to correctly size and route the gas supply line to the appliance. Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing, locations, controls, pressure, sediment, and more. Certainly no one unfamiliar and unqualified should attempt sizing or installing gas piping.
Remove the gas line access cover plate on either the left or right side of the fireplace (see Figure 7 showing locations).
Install 1/2" min. to 1-1/2" max. inside diameter approved gas line through the firebox wall for connection to the Vent-Free room heater inside the firebox. Connect the gas line before the firebox is enclosed in the finished wall. Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fiberglass insulation.
Ensure that a sediment trap is installed in the existing gas line, if not, install a sediment trap upstream of the heater to prevent moisture and contaminants from passing through trap to the heater controls and burners. Failure to do so could prevent the heater from operating reliably.
An external regulator must be used on all pro­pane (L.P.G). heaters, in addition to the regulator fitted to the heater, to reduce the supply tank pressure to 13" W.C. (maximum). Any copper
-
tubing used to supply propane (L.P.G). from the tank must be internally tinned.
WARNING
Check Gas Type: The gas supply must be the same as stated on the heater’s rating plate. If the gas supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model.
IMPORTANT
Hold heater regulator with a wrench to prevent movement when connect­ing to inlet piping.
WARNING
Connecting directly to an unregu­lated propane (L.P.G.) tank can cause an explosion.
IMPORTANT
Pack unfaced fiberglass insulation material (not provided) around the gas line access hole on appliance and all exterior gas line penetra­tion holes.
TEST ALL CONNECTIONS FOR GAS LEAKS (FACTORY AND FIELD)
Test all gas joints from the gas meter to the gas heater regulator for leaks using a gas leak test solution (also referred to as bubble leak solution).
NOTE: Using a soapy water solution as a leak detection solution is not recommended because the soap residue that is left on the pipes/fittings can result in a false-positive leak detection reading if a gas leak sniffer is used. Soap residue can also result in corrosion over time.
DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS.
Leak Test Procedure:
Turn on gas supply and test for gas leaks using a gas leak test solution.
A. Light the appliance (refer to the lighting
instructions label provided with gas logs).
B. Brush all joints and connections with the gas
leak detection solution. If bubbles are formed, or gas odor is detected, turn the gas control knob (off/pilot/on) to the “OFF” position. Either tighten or refasten the leaking connection, then retest as described above.
C. When the gas lines are tested and found to
be leak free, rinse off the leak testing solution from gas line fittings.
8
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 9
Top Spacer
Firebox Framing
Construct firebox framing following Figures 8 through 10 and Table 1 on Page 11 for your
specific installation requirements. Refer to Figure 7 on Page 10 for firebox dimensions.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the appliance is installed directly on carpeting, vinyl tile (other than ceramic) or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Be sure firebox rests on a solid continuous floor or platform with appropriate framing for support and so that no cold air can enter room from under the firebox.
CAUTION
Do not block the heat-circulating air inlets and outlets on these fireboxes. Doing so may create a potential fire hazard.
The firebox may be positioned and then the framing built around it, or the framing may be constructed and the firebox positioned into the opening.
Usually, no special floor support is needed for the firebox, however, to be certain:
1. Estimate the total weight of the firebox system and surround materials such as marble, brick, stone, etc., to be installed (see Product Reference Table on Page 10 for appliance weight).
2. Measure the square footage of the floor space to be occupied by the system and surrounds.
3. Note the floor construction, i.e. 2" x 6", 2" x
8" or 2" x 10", single or double joists, type and thickness of floor boards.
4. Use this information and consult your lo-
cal building code to determine if you need additional support.
If you plan to raise the firebox, build the plat­form assembly then position firebox on top. Secure the platform to the floor to prevent possible shifting.
Firebox Installation
Step 1. Frame these appliances as illustrated
in Figures 8 through 10. All framing details must allow for a minimum clearance to combustible framing members as shown in Figures 2 through 5. Also refer to appliance specifications on Page 10 . Headers may be in direct contact with the appliance top spacers but must not be supported by them or notched to fit around them. All construction above the appliance must be self supporting, DO NOT USE
THE APPLIANCE FOR STRUCTURAL SUPPORT.
NOTE: The framed depth from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the depth must be measured from the drywall surface. It is important that this dimension be exact.
Step 2. Level the firebox by checking the top edge of the firebox. Shim if necessary.
Step 3. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face. Use 8d nails or equivalent nail or screw (see Figure 6).
NOTE: The nailing flange and the area directly behind the nailing flange is exempt from the clearances described on the firebox clearance label.
IMPORTANT
Under no circumstances shall the firebox top spacers be removed or modified (see Figure 7). The header may be in direct contact with the top spacers but must not be supported by them notched or altered to fit around them.
8d Nail
Figure 6
9
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 10
SPECIFICATIONS
Front View
Dimensions - Inches (millimeters)
Model No. A B C D E F G H J K L M N P *Q
Atlas36
Series
Atlas42
Series
36
(914)28(711)
42
(1067)28(711)
41-3/4 (1061)
47-3/4 (1213)
41-1/4
(1048)
41-1/4 (1048)
23-1/2
(597)20(508)3(76)
29-1/2
(749)20(508)3(76)
8-3/8 (213)
8-3/8 (213)
15-7/8
(403)
15-7/8
(403)
7-1/2 (190)12(305)
7-1/2 (190)12(305)
1-3/8
(35)
1-3/8
(35)
5-1/2 (140)
5-1/2 (140)
34-3/8
(873)
34-3/8
(873)
33-5/8
(854)
33-5/8
(854)
Product Reference Information
Cat. No. Model Ship. Weight (lbs) Shipping Volume
F0391 Atlas36ZP2 200 lbs
F0392 Atlas36ZP3 200 lbs
F0393 Atlas42ZP2 230 lbs
F0394 Atlas42ZP3 230 lbs
22 Cu. Ft.
22 Cu. Ft.
26 Cu. Ft.
26 Cu. Ft.
A hood is optional for models Atlas36 Series and Atlas42 Series
Inches (millimeters)
E
Top View
1 (25)
7-1/16
(179)
B
Top of Bottom Refractory
6-3/16 (157)
A
C
F
Bottom of Firebox Opening
5-3/4 (146)
Interior Firebox Dimensions**
Firebox Model 36” 42”
Front Width 35 (889) 41 (1042)
Rear Width 23-1/4 (591) 29-1/4 (743)
Depth 17-3/8 (441) 17-3/8 (441)
Height 28 (711) 28 (711)
* * Dimensions are to assist you in selecting a log set that is
a compatible size.
Junction Box
N
M
Top Stand-Off Spacers (4 places)
Top of Firebox Opening
* Canopy
D
*Q
P
3-9/16
(90)
Gas Line Access ­Both Sides
J
H
K L
Right Side View
G
Access Opening for Junction Box - Right Side Only (remove the knock-out before installing J-Box). J-Box / Electrical Kit is not provided with appliance.
10
Figure 7
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 11
FRAMING SPECIFICATIONS
Corner Installation
Framing Dimensions
Opening Atlas36 Series Atlas42 Series
A 42-1/4" (1073) 48-1/4" (1226)
B 44-1/4" (1124) 44-1/4" (1124)
C 23-5/8" (600) 29-5/8" (753)
D 11-1/4" (286) 14-1/4" (362)
E 63-1/2" (1613) 69-1/2" (1765)
F 31-3/4" (807) 34-3/4" (883)
G 20-1/2"( 521) 20-1/2"( 521)
H 44-1/4" (1124) 49-1/8" (1248)
Table 1 -
This Table corresponds to Figures 8, 9 & 10
WARNING: Do not fill spaces around the firebox with insulation or other materials.
Header
This Figure corresponds to Table 1
H
Figure 9
Parallel Installation
Rough Framing Face (Unfinished Shown)
Back Wall Of Chase/Enclosure Including Finishing Materials If Any
D
C
A
E
Back Wall Of Chase/Enclosure Including Finishing Materials If Any
C
Rough Framing Face (Unfinished Shown)
Rough Framing Face (Unfinished Shown)
F
G
This Figure corresponds to Table 1
B
Figure 8
A
Hood Kit Installation (see ordering information on Page 16)
The firebox canopy (hood) shall not be modified or replaced with a canopy that may be provided with the unvented decorative room heater.
These hood kits are design to be fitted to the face of the appliance directly above the firebox opening. In addition to providing an aesthetically pleasing appearance to your appliance, the hood reduces heat effects to decora­tive mantels and finish materials located directly above the fireplace and reduces the Mantel / Trim clearances (see Figures 4 and 5 on Page 7).
Please read this entire manual and understood thoroughly before proceeding with the installation of these kits.
Step 1. Using a 5/16" nut driver or socket, remove the screen and rod
assemblies as shown in Figure 11.
Step 2. Align the hood with the holes in the side frames as shown in
Figure 12. Install three screws as shown in Figure 12. Make sure hood is level and secure.
Step 3. Reinstall screen and rod assemblies (see Figure 11).
Figure 10
Removing Screens & Rods:
Remove screws (see dotted lines). Pull out rods from locating holes on side of firebox opening.
Reinstalling Screens & Rods:
Insert rods into corresponding locating holes on sides of firebox opening, then reinstall screws as shown.
Figure 11
G
A
This Figure cor­responds to Table 1
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
11
Page 12
Grounded
to Appliance
Blower Motor
Motor Plug
Receptacle
120V
Appliance Junction Box
Hood
IMPORTANT
The Ground Lead must be connected to the green screw (located on the junction box). Failure to do this could result in an electrical short or shock injury.
Top View
* Electrical Outlet
Blower
Bend blower mounting tabs up to secure blower in place
* Junction Box
Tie a loose knot in power cord to take up slack
Side View
Figure 12
OPTIONAL EQUIPMENT
Blower Kits
The FBK-100 Blower Kits are used when a wall-mounted ON/OFF blower switch is desired, and the FBK-200 Blower Kits are used when a wall-mounted variable speed blower control (rheostat) is desired. NOTE: A Junction Box
is provided.
The blower is installed beneath the firebox. Room air is drawn in through the side slots of the fireplace, heated as it passes across the firebox, and discharged through the upper area of the firebox opening.
The installation instructions for installing these blower kits are on Pages 12 through 14. Also see the installation instructions provided with the blower kits (Form #750028M). For electrical requirements, refer to Figures 13, 14 and 15.
If the blower kit is to be installed at the time of installation or at a later date, the main power supply must be installed at the time of instal­lation. This will require that the electrical
connections must be made BEFORE the firebox is framed and enclosed in the finished walls.
Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply and connect to electrical receptacle wires and wall switch or rheostat.
The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the national electrical code, ANSI/NFPA 70-latest edition. (In Canada, the current CSA C22.1 Canadian Electrical Code).
CAUTION
Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service.
NOTE: If any of the original wire as supplied must be replaced, it must be replaced with type AWM 105 degree C - 14 gage wire.
Figure 13
* The Junction Box / Electrical Kit is not included. See Page 15 for ordering information.
Figure 14
120V, 60HZ, 1PH BLOWER CONTROL CIRCUIT
Ground - Green
Neutral - White
HOT SIDE OF RECEPTACLE
Black
Junction Box
Plug blower into this receptacle
Blower
*An ON/OFF Wall Switch is used with the FBK-100 kit (field provided or sold separately - order P/N 85L87); A Variable Speed Control (provided) is used with the FBK-200 kit. The installation of these kits also require a Junction Box / Electrical Kit (provided).
NOTE: If any of the original wire as supplied must be replaced, it must be replaced with type AWM 105 degree C - 14 gage wire.
WIRING
120 VAC Black
* Wall-mounted ON/ OFF Blower Switch or Variable Speed Control Switch.
Plug-in Electronic Burner Assembly (sold separately) into this receptacle
NEUTRAL SIDE OF RECEPTACLE
Tab Intact
Green Ground Screw
Field Wired
Factory Wired
Ground
Figure 15
12
CAUTION: Label all wires prior to dis­connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 13
Installation Instructions - FBK-100 or FBK 200 Blower Kits and JBK Junction Box Kit
IMPORTANT
All electrical wiring must be performed by licensed Elec­tricians. Electrical wiring must comply with the National Electrical Code ANSI/ NFPA 70 - latest edition
Step 1. Follow the instructions below for the model you are installing: Models
Atlas36ZP2, Atlas36ZP3, Atlas42ZP2 and Atlas42ZP3:
Lift out the bottom refractory panel (see Figure 16).
Step 2. Remove the rectangular knock-out (for J-Box) on the right side of unit (see Figure 7 for location). Install the Junction Box & Electrical outlet below the firebox floor into the rectangular opening on the right side cabinet panel where you removed the knock-out (see Figures 18 and 19).
• Squeeze the J-Box flanges together to fit into the opening shown in Figures 18 and 19.
• Wires will need to be passed through the hole shown in Figure 17.
• An approved strain relief bushing (not supplied with the kit), is required to restrain the wires (see Figure 17).
Step 3. Loosely tie a knot in the power cord to take up slack (see Figure 20).
Step 4. Locate the tabs shown in Figure 21. Position the blower assembly
so that the tabs (located on the cabinet base) are seated in the notches of the blower bracket. Bend the tabs over to secure the blower assembly (see
Figure 22).
Step 5. Plug power cord into the electrical outlet as illustrated in Figure 14.
Cover Plate
Remove knock-out
(strain relief bush­ing [not supplied] presses into this hole around romex wires - see Step 8 on Page 14).
Screw
Figure 17 - Junction Box Kit (all models)
J-Box & Electrical Outlet
Firebox floor
Install into side wall rectanular opening
Figure 18 -
Model Atlas42ZP2 Shown
J-Box & Receptacle
J-Box Flange
Models: Atlas36ZP2, Atlas36ZP3, Atlas42ZP2 and Atlas42ZP3
Figure 16
Lift Out Bottom Refractory Panel
WARNING
LIFTING HAZARD
SINGLE -PERSON LIFT COULD
CAUSE INJURY.
USE ASSISTANCE WHEN MOVING
OR LIFTING.
J-Box Flanges
Right Outside Cabinet Panel
J-Box & Electrical Outlet
Wires
Figure 19
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
13
Page 14
Model Atlas42ZP2 Shown
Firebox floor
Step 8. Ensure that power supply wires are NOT "live" before making these connections). Install J-Box Cover Plate as follows:
Feed the * Romex wires (or other equivalent plastic insulated wire - Refer ANSI/NFPA 70 - National Electrical Code - Latest Edition) through the J-Box Cover rectangular opening, then con­nect to the J-box wires. The strain relief bushing (not supplied) should be pressed into the knock-out on J-box cover around the Romex (this will provide protection to the wires and prevents strain against connections from J-box). See Wiring Diagram - Figure
15. Install the cover plate over J-Box opening on appliance as shown in Figure 23.
Loose knot in power cord to take up slack
Figure 20
Model Atlas42ZP2
Cabinet Base
Locating Tabs
Figure 21 -
Atlas42ZP2 Shown
Bend Locating Tabs Over
(into notches)
Figure 22 - Atlas42ZP3 Shown
Step 6. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the right side of appliance.
Step 7. Locate the J-Box cover (provided in J-Box Kit). Remove the round knock-out (see Figure 19).
NOTE: Wire connections should be positioned inside of the ap­pliance.
* Romex is a plastic insulated wire from power supply - sometimes called non-metallic sheath.
Right Side Panel of Firebox
J-Box opening on appliance
Use screw provided and
secure in place as shown
Screw
Cover Plate
The notched side of cover plates goes inside firebox panel
Figure 23 - Installing J-box Cover Plate - All Models
Step 9. Follow the instructions below for the kit you are installing:
FBK-100 Kits - Install a field-provided (or P/N 85L87) ON/OFF wall
switch in a convenient location on a wall, near the fireplace.
FBK-200 Kits - Install the kit-provided variable speed control
(rheostat) in a convenient location on a wall, near the fireplace.
Step 10. Follow the instructions below for the model you are installing:
Models Atlas36ZP2, Atlas36ZP3, Atlas42ZP2 and Atlas42ZP3:
Reinstall the bottom refractory panel that was removed on Step 1
(see Figure 16).
14
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 15
FIREBOX FINISHES
There are a wide variety of “finished looks” for your built-in Vent-Free firebox from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the black front facing. Seal all joints between the black facing and wall surrounds to prevent air intrusion. Use noncombustible caulking material only to seal the black metal facing to the surround material on the finished wall. See Figures 3 and 24.
Raised Hearth Extension
A hearth extension may be used but is not required for these appliances. A raised hearth extension may be used as shown in Figure 24.
Combustible Wall
Non-Combustible Wall (see Figures 4 and 5,
Page 7)
APPROVED ACCESSORIES AND COMPONENTS
This attractive screen door is easy to install and enhances the appearance of the appliance.
Decorative Screen Door Panel Kit
Cat. No. Model Where Used
H1960 ASD3628-TI Atlas36 Series
H1961 ASD4228-TI Atlas42 Series
(ref. Form #750209M)
Raised Hearth Extension
(combustibles allowed. No carpet or vinyl)
5-3/4" Max.*
* From Base to Bottom of Firebox Opening (floor)
Fireplace Opening
Firebox Floor
Combustible Platform
SIDE VIEW
Decorative Volcanic Stone
Cat. No. Model No. Description
80L42 FDVS Bag of Volcanic Stone
(ref. Form #750010M)
Decorative Volcanic Stone
The decorative volcanic stone, Model FDVS, can be used to enhance the look of your appliance. Order model FDVS for replacement of stone when needed. Spread the decorative volcanic stone evenly around the bottom of the firebox.
Base
Figure 24 - Raised Hearth Extension
15
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 16
APPROVED ACCESSORIES AND COMPONENTS
Black Hood
Cat. # Model Models Where Used
H1989 FC36
H1990 FC42
(ref. Form #750195M)
Atlas36 Series
Atlas42 Series
The variable speed control rheostat is included with FBK-200 models only
An ON/OFF wall switch can be used with the FBK-100 models (field supplied or order P/N 85L87 Wall Switch Kit, shown below)
Cat.
No.
80L84 FBK-100
80L85 FBK-200
* The installation of these kits also require a Junction Box / Receptacle
Kit, not included. See ordering information on Page 15.
* Forced Air Blower Kits
Model No. Description
Blower, Standard (single speed)
Blower, Variable Speed (w/wall-mounted switch)
Blower Kit
The FBK-100 blower provides for a constant velocity forced air circulation feature for your ap­pliance. The FBK-200 assembly with variable speed wall switch provides a forced air circulation feature for your appliance.
Outside Air Gate & Duct Kit
Cat. No. Model No. Description
H3991 OAK-UVFRC Outside Air Gate & Duct Kit
(ref. Form #750206M)
Outside Air Gate & Duct Kit
These kits have an air gate assembly, 4" diameter duct and a termination hood. The air gate allows adjustment of the amount of outside air delivered to the fire for combustion. Only one kit, located on the right side of the fireplace, is required.
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch-up
T
N
I
paint kit.
Touch-Up Paint Kit
Black touch-up paint, powder coat (for firebox face and hood)
Black touch-up paint, Firebox Interior
P
A
Cat. No. Model No. Description
F1882 SCTPSAB
F3373 ---
ON/OFF Wall Switch Kit
The ON/OFF wall switch kit may be used to control the blower operation, if FBK­100 blower kit is installed. Install the ON/OFF wall switch in a convenient location near the fireplace.
White Wall Switch Kit
Cat. No. Model No. Description
85L87 FWSK ON/OFF Wall Switch Kit
For more information on available log sets for this and other Astria products, visit Astria.us.com.
16
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Page 17
REPLACEMENT PARTS
2
1
2
1
An exploded view of the firebox with numbered parts and a replacement parts list can be found on the Page. Normally, all parts should be ordered through your distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The *model number of the firebox.
2. The *serial number of the firebox.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the firebox.
* NOTE: The model and serial number can be found on the rating label located on the bottom left front corner of the appliance.
If you encounter any problems or have any questions concerning the installation of a Vent-Free heater in this system, please contact your distributor or dealer or visit our website at Astria.us.com.
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
WARNING
Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards.
3a
3b
3
2
3
3c
4
1
WARNING
4
3d
5
5
REFRACTORY PANELS
LIFTING HAZARD
SINGLE - PERSON LIFT COULD CAUSE INJURY.
USE ASSISTANCE WHEN
MOVING OR LIFTING.
No. Description
--- Vent-Free Firebox Assembly F0391 1 F0392 1 F0393 1 F0394 1
1 Firescreen H2694 2 H2694 2 H2699 2 H2699 2
2 Rod, Screen H3919 2 H3919 2 H2700 2 H2700 2
3 Refractory Panel Set, 4 pc. F3528 1 F3396 1 F3529 1 F3530 1
3a Refractory, Left (order set) --- 1 --- 1 --- 1 --- 1
3b Refractory, Right (order set) --- 1 --- 1 --- 1 --- 1
3c Refractory, Rear (order set) --- 1 --- 1 --- 1 --- 1
3d Refractory, Bottom (order set) --- 1 --- 1 --- 1 --- 1
4 Hood H1989 1 H1989 1 H1990 1 H1990 1
5 Junction Box Assembly H6048 1 H6048 1 H6048 1 H6048 1
Atlas36ZP2 (WS)
Whited Stacked
Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.
Atlas36ZP3 (WH)
Whited Herringbone
Atlas42ZP2 (WS)
Whited Stacked
Atlas42ZP3 (WH)
Whited Herringbone
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
17
Page 18
NOTES
18
Page 19
P/N 900199-00, Rev. C 02/2018
1769 East Lawrence Street • Russellville, AL 35654
Innovative Hearth Products
®
Astria
Brand Gas Fireplace
Limited Lifetime Warranty
THE WARRANTY
Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria® brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The product body, firebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Lifetime Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Lifetime Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided. The product body, firebox and barrier carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from this Limited Lifetime Warranty. The following do not carry the Limited Lifetime Warranty but are warranted as follows:
Burner – Repair or replacement for five years from the date of installation Gas components & electrical components – Repair or replacement for one year from the date of installation Gaskets – Repair or replacement for one year from the date of installation Gold & nickel plating - Replacement for two years from date of installation. Excludes tarnishing Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component Light bulbs & batteries – Replacement for 90 days from the date of installation Logs – Replacement for five years from the date of installation against thermal breakage only Optional blowers & remote controls – Repair or replacement for one year from the date of installation Optional glass doors & optional glass accessories – Repair or replacement for 90 days from the date of installation Optional surrounds – Stone/Natural Materials: Replacement for one year against cracking or breakage due to thermal stress. Other Materials: Replacement for one
year. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit
Tempered Glass -Replacement for one year from the date of installation
Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without first obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.ASTRIA.US.COM.
Printed in U.S.A. © 2013 Innovative Hearth Products
19
Innovative Hearth Products
Page 20
IHP reserves the right to make changes at any time, without notice, in design, materials,
P900238-00
specifications, prices and the discontinuance of colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2013 Innovative Hearth Products
P/N 900238-00 REV. C 09/2018
1769 East Lawrence Street • Russellville, AL 35654
Loading...