This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual for correct installation and operational procedures. For assistance or
additional information consult a qualified installer, service agency or the gas supplier.
This fireplace is approved for use on an outdoor application provided that a certified gas log set approved
Models
under the ANSI Z21.97 standard with a maximum input rate of 40,000 BTU's is used.
installed when using a vent-free log heater (see Parts, page 17).
An IHP hood must be
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION.
WARNING: FOR USE ONLY WITH A LISTED, GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO
EXCEED 40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
causing property damage, personal injury or death.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
— WHAT TO DO IF YOU SMELL GAS
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Page 2
Thank you for your purchase. We appreciate your
business!
Please carefully read and follow all instructions in this manual. Pay
special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help
ensure many years of dependable and enjoyable service from your
fireplace.
Please read and understand these instructions before installing
or operating.
NOTICE: The firebox canopy must not be modified or
replaced with a canopy that may be provided with the
unvented decorative room heater.
IMPORTANT: Read this owner’s manual carefully and
completely before trying to assemble, operate or
service this fireplace. Improper use of this fireplace
can cause serious injury or death from burns, fire,
explosion, electrical shock and carbon monoxide
poisoning.
DANGER: Carbon monoxide poisoning may lead
to death!
WARNING: Any change to this firebox or its controls
can be dangerous.
WARNING: Do not allow fans to blow directly into
the firebox. Avoid any drafts that alter burner flame
patterns. Ceiling fans can create drafts that alter
burner flame patterns. Altered burner patterns can
cause sooting.
WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for
use with this firebox.
Do not place clothing or other flammable material on
or near the appliance. Never place any objects in the
firebox or on logs.
Firebox front and screen becomes very hot when running firebox. Keep children and adults away from hot
surfaces to avoid burns or clothing ignition. Firebox
will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carefully supervise young children when they are in
the room with firebox.
Keep the firebox area clear and free from combustible
materials, gasoline, and other flammable vapors and
liquids.
You must operate this firebox with the provided
firebox screen and hood in place. Make sure these
parts are in place and screens are closed before
running installed gas log heater. Replace hood with
IHP catalog no. (J4353) 50", (J4354) 42", or (J4355)
36" only. This hood has been designed to keep the
operation of your firebox safe and efficient.
Due to high temperatures, the appliance should be
located out of traffic and away from furniture and
draperies.
Astria.US.com
126770-01_B2
Page 3
SAFETY Continued
1. Do not use this firebox as a wood burning fireplace. Use only
decorative unvented room heaters (log sets).
2. Do not add extra logs or ornaments such as pine cones, vermiculite
or rock wool. Using these added items can cause sooting.
3. Use only the provided hood. See Parts, page 17.
4. Vent-free gas log heaters installed in these fireboxes require
fresh air ventilation to run properly. See Air for Combustion and
Ventilation, page 7.
5. Do not run vent-free heaters installed in these fireboxes
• where flammable liquids or vapors are used or stored
• under dusty conditions
6. Do not use this firebox to cook food or burn paper or other objects.
7. Turn unit off and let cool before servicing. Only a qualified service
person should service and repair firebox.
8. Operating vent-free heaters installed in these fireboxes above
elevations of 4,500 feet could cause pilot outage.
9. Do not use the firebox if it has been under water.
10. Before using furniture polish, wax, carpet cleaner or similar
products, turn heater off. If heated, the vapors from these
products may create a white powder residue within burner box
or on adjacent walls and furniture.
11. Provide adequate clearances around air openings.
LOCAL CODES
Install and use firebox with care. Follow all local codes. In the absence
of local codes, use the latest edition of The National Fuel Gas Code
ANSI Z223.1/NFPA 54*. Firebox must be electrically grounded in
accordance with the National Electrical Code, ANSI/NFPA70 (latest
edition).
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th floor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
PRODUCT FEATURES
OPERATION
This firebox is designed for use with approved ANSI Z21.11.2 decorative type unvented room heaters. (Physical size limitations apply.
Refer to minimum firebox requirements supplied with log heater.)
It requires no outside venting or chimney making installation easy
and inexpensive.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of
Massachusetts if the following additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with
527 CMR 30.
• Installation and repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches
(92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
• Unvented appliances may NOT be installed in bedrooms or
bathrooms.
• A working smoke detector must be installed in the area where
vent-free appliances are installed.
Seller of unvented propane or natural gas-fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit.
LOCATING FIREBOX
PLANNING
Plan where you will install the firebox. This will save time and money
later when you install the firebox. Before installation, consider the
following:
1. Where firebox will be located. Allow for wall and ceiling clearances
(see Installation Clearances, page 9).
2. Everything needed to complete installation.
3. These models CANNOT be installed in a bedroom unless maximum
Btu rating of installed vent-free log set is less than 10,000 Btu/hr.
4. Proper air for combustion and ventilation (page 7).
OUTDOOR ENCLOSURE REQUIREMENTS
Must conform to one of the following conditions:
• With walls on all sides, but with no overhead cover;
• Within a partial enclosure which includes an overhead cover and
no more than two side walls. These side walls may be parallel,
as in breezeway or at right angles to each side; or
• Within a partial enclosure which includes an overhead cover
and three sidewalls, as long as 30% or more of the horizontal
periphery of the enclosure is permanently open.
Astria.US.com126770-01_B
3
Page 4
36" MODELS
54-
PRODUCT SPECIFICATIONS
30-
11-
1
/2"
7-
1
/2"
3-
30"
7
/8"
1
/2"
29"
22-
20-
1
/4"
(Ref.)
19"
7
/8"
4-
3
/4"
1
/8"
36" HEARTH
35-
1
/4"
1-
1
/4"
50"
3
/8"
36-
7"
36"
45-
1
/8"
9-
1
/2"
3
3-
/8"
3
7-
/8"
1
/8"
11-
Figure 1 - Venetian36
Astria.US.com
126770-01_B4
Page 5
42" MODELS
54-
PRODUCT SPECIFICATIONS Continued
3
/8"
30-
3
32-
/8"
7
4-
/8"
3
3-
/4"
1
/8"
11-
1
/2"
3
26-
/8"
3
41-
/8"
42" HEARTH
21-3/4"
23"
(Ref.)
1
1-
/4"
50"
30"
3
/8"
36-
7-
7
7"
/8"
42"
1
/8"
51-
9-
1
/2"
3
/8"
3-
3
8-
/4"
13"
Figure 2 - Venetian42
Astria.US.com126770-01_B
5
Page 6
(Ref.)
50" MODELS
PRODUCT SPECIFICATIONS Continued
54-
1
11-
/2"
32-
30"
3
38-
/8"
3
/8"
7
/8"
4-
3
3-
/4"
3
/8"
34-
3
/8"
49-
50" HEARTH
21-3/4"
1-
23"
1
/4"
1
/8"
50"
3
/8"
36-
7-
7
7"
/8"
50"
1
/8"
59-
9-
1
/2"
3
/8"
3-
3
8-
/4"
13"
Figure 3 - Venetian50
Astria.US.com
126770-01_B6
Page 7
AIR FOR COMBUSTION AND VENTILATION
WARNING: This firebox shall not be installed in a
room or space unless the required volume of indoor
combustion air is provided by the method described
in the National Fuel Gas Code, ANSI Z223.1/NFPA 54,
the International Fuel Gas Code, or applicable local
codes. Read the following instructions to insure proper
fresh air for this and other fuel-burning appliances in
your home.
Today’s homes are built more energy efficient than ever. New materials,
increased insulation and new construction methods help reduce heat
loss in homes. Home owners weather strip and caulk around windows
and doors to keep the cold air out and the warm air in. During heating
months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home ne eds
to breathe. Fresh air must enter your home. All fuel-burning appliances
need fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel burning appliances
draw air from the house to operate. You must provide adequate fresh
air for these appliances. This will insure proper venting of vented fuelburning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation
classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 7 through 8 will help you classify your space
and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh air.
Unusually tight construction is defined as construction where:
a. walls and ceilings exposed to the outside atmosphere have a
continuous water vapor retarder with a rating of one perm (6 x
-11
10
kg per pa-sec-m2) or less with openings gasketed or sealed
and
b. weather stripping has been added on openable windows and
doors and
c. caulking or sealants are applied to areas such as joints around
window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations
for plumbing, electrical and gas lines and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the three criteria above, proceed
to Determining Fresh-Air Flow For Firebox Location.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined
space as a space whose volume is less than 50 cubic feet per 1,000
Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space
whose volume is not less than 50 cubic feet per 1,000 Btu per hour
(4.8 m3 per kw) of the aggregate input rating of all appliances installed
in that space. Rooms communicating directly with the space in which
the appliances are installed*, through openings not furnished with
doors, are considered a part of the unconfined space.
* Adjoining rooms are communicating only if there are doorless
passageways or ventilation grills between them.
DETERMINING FRESH-AIR FLOW FOR FIREBOX LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between
the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =__________cu. ft. (volume of space)
Example: Space size 22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling
height) = 3,168 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with grills
or openings, add the volume of these rooms to the total volume
of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr
the space can support.
_______ (volume of space) x 20 = (Maximum Btu/Hr the space
can support)
Example: 3,168 cu. ft. (volume of space) x 20 = 63,360 (maximum
Btu/Hr space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free fireplace ________ Btu/Hr
Gas water heater* ________ Btu/Hr
Gas furnace ________ Btu/Hr
Vented gas heater ________ Btu/Hr
Gas fireplace logs ________ Btu/Hr
Other gas appliances*+ _____ Btu/Hr
Total = _______ Btu/Hr
* Do not include direct-vent gas appliances. Direct-vent draws
combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater 40,000 Btu/Hr
Vent-free fireplace + 39,000 Btu/Hr
Total = 79,000 Btu/Hr
4. Compare the maximum Btu/Hr the space can support with the
actual amount of Btu/Hr used.
______ Btu/Hr (maximum the space can support)
______ Btu/Hr (actual amount of Btu/Hr used)
Example: 63,360 Btu/Hr (maximum the space can support)
79,000 Btu/Hr (actual amount of Btu/Hr used)
Astria.US.com126770-01_B
7
Page 8
AIR FOR COMBUSTION AND VENTILATION Continued
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills Into
Adjoining
Room,
Option 1
12"
12"
Outlet
Air
Ventilated
Attic
Outlet
A
ir
Inlet
Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
The space in the example is a confined space because the actual Btu/
Hr used is more than the maximum Btu/Hr the space can support.
You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the
extra space provides an unconfined space, remove door to adjoining
room or add ventilation grills between rooms. See Ventilation Air
From Inside Building.
B. Vent room directly to the outdoors. See Ventilation Air From
Outdoors.
C. Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room
unconfined.
If the actual Btu/Hr used is less than the maximum Btu/Hr the space
can support, the space is an unconfined space. You will need no additional fresh air ventilation.
WARNING: If the area in which the heater may be
operated does not meet the required volume for indoor
combustion air, combustion and ventilation air shall
be provided by one of the methods described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, the
International Fuel Gas Code, or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When
ventilating to an adjoining unconfined space, you must provide two
permanent openings: one within 12" of the ceiling and one within 12"
of the floor on the wall connecting the two spaces (see options 1 and
2, Figure 4). You can also remove door into adjoining room (see option
3, Figure 4 ). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA
54, Air for Combustion and Ventilation for required size of ventilation
grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must
provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Air for Combustion and Ventilation for required size of
ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air
into attic if attic has a thermostat-controlled power vent.
Heated air entering the attic will activate the power vent.
Figure 5 - Ventilation Air from Outdoors
Figure 4 - Ventilation Air from Inside Building
Astria.US.com
126770-01_B8
Page 9
INSTALLATION
WARNING: A qualified service person must install
firebox. Follow all local codes.
WARNING: Never install firebox
• in a bedroom or bathroom*
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable
objects are less than 36" from front or 42" from top
of firebox; for side clearances see Figure 6
• in high traffic areas
• in windy or drafty areas
* Unless installed log set is rated at 10,000 Btu/Hr or
less, 6,000 for bathrooms
CAUTION: Log heaters installed in this firebox create warm air currents. These currents move heat to
wall surfaces next to firebox. Installing firebox next to
vinyl or cloth wall coverings or operating firebox where
impurities (such as, but not limited to, tobacco smoke,
aromatic candles, cleaning fluids, oil or kerosene lamps,
etc.) in the air exist, may discolor walls or cause odors.
NOTICE: The firebox identification label (including
model number, serial number, clearances, etc.) is
located on a chain under the bottom refractory.
INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 6)
A. Clearances from the side of the fireplace cabinet to any combus-
tible material and wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf, etc. is made of combus-
tible material and protrudes 3 1/2" from the wall. This combustible
material must be 4" from the side of the fireplace cabinet (see
Figure 6).
B. Clearances from the top of the firebox opening to the ceiling should
not be less than 42".
C. When the firebox is installed directly on carpeting, tile or other
combustible material, other than wood flooring, the firebox should
be installed on a metal or wood panel extending the full width and
depth of the enclosure.
D. Clearances from the bottom of firebox to the floor is 0".
These fireboxes can be installed as freestanding units against a
wall with approved cabinet mantels that may be available from your
retailer or supplier, or as a built-in unit. The clearances are the same
for either installation method.
IMPORTANT: Vent-free gas log heaters add moisture to the air. Although this is beneficial, installing firebox in rooms without enough
ventilation air may cause mildew to form from too much moisture.
See, page 7.
IMPORTANT: Make sure the firebox is level. If firebox is not level, log
set will not work properly.
Note: Your firebox is designed to be used in zero clearance installations. Wall or framing material can be placed against any exterior
surface on the rear, sides, top or bottom of your firebox, except
where standoff spacers are integrally attached. If standoff spacers
are attached to your firebox, these spacers can be placed directly
against wall or framing materials. Use the dimensions shown for
rough opening to create the easiest installation.
Use dimensions shown for rough openings to create the easiest
installation (see Built-In Firebox Installation, page 10).
Example
*
*Minimum 16" from Side Wall
Figure 6 - Minimum Clearance for Combustible to Wall
Astria.US.com126770-01_B
9
Page 10
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12" 16" 20"
1
1
/
2
"
6
3
/
4
"
12"
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projections off of the facing
material.
Framing
Material
INSTALLATION Continued
100" (50" Models)
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in firebox, you must meet
the minimum allowable clearance between mantel shelf and top of
firebox opening shown in Figure 7. These are the minimum allowable mantel clearances for a safe installation. Use larger clearances
wherever possible to minimize the heating of objects and materials
placed on the mantel.
CAUTION: Do not allow the vent-free gas log heater
to touch or extend beyond the fireplace screen.
NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard. Follow all minimum clearances shown in this manual.
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this firebox involves installing firebox into a
framed-in enclosure. This makes the front of firebox flush with wall. If
installing a mantel above the firebox, you must follow the clearances
shown in Figure 7. Follow these instructions to install the firebox in
this manner.
1. Frame in rough opening. The firebox framing should be constructed
of 2 x 4 lumber or heavier. Use dimensions and rough opening layout in Figure 8. Adjust framing so that firebox flushes with finished
wall surface. If installing in a corner, use dimensions in Figure 9,
for rough opening.
2. Install gas piping to firebox location. See Gas Line Installation on
page 14 and Connecting to Gas Supply in log set owner’s manual.
54-5/8"
Figure 7 - Minimum Mantel Clearances for Built-In Installation
NOTICE: If your installation does not meet the minimum
clearances shown, you must do one of the following:
• raise the mantel to an acceptable height
• remove the mantel
3. Carefully set firebox in front of rough opening with back of firebox
4. Carefully insert firebox into rough opening.
5. Attach firebox to wall studs using nails or wood screws through
6. Install and properly test gas log heater. Follow installation in-
Astria.US.com
1
/8"
3
/8" (36" Models)
45-
3
51-
/8" (42" Models)
3
59-
/8" (50" Models)
30-
1
28-
/4"
(36" Models)
Figure 8 - Framing Dimensions
Maintain 1-1/2"
Clearance at Sides
and Back of Fireplace
structions included with the vent-free gas log heater that is being
installed.
126770-01_B10
Page 11
INSTALLATION Continued
IMPORTANT: When finishing your firebox, combustible materials such
as wall board, gypsum board, sheet rock, drywall, plywood, etc. may
be butted up next to the sides and top of the firebox. Combustible
materials should never overlap the firebox front facing.
WARNING: Do not allow any combustible materials
to overlap the firebox front facing.
IMPORTANT: Noncombustible materials such as brick, tile, etc.
may overlap the front facing, but should never cover any necessary
openings.
WARNING: Do not allow noncombustible materials
to cover any necessary openings.
Nails or
Wood
Screws
1. Assemble cabinet mantel as instructed.
2. Install gas piping to firebox location. See Gas Line Installation on
page 14. You may have to cut an access hole in the floor or wall to
run gas line to firebox. Make sure to locate access hole so cabinet
mantel will cover it when installed (see Figure 11).
3. Place firebox on floor in desired location. Make sure mantel will
be flush against wall when installed.
4. Carefully slide cabinet mantel over firebox. Be careful not to
scratch firebox, cabinet mantel, flooring, etc., when installing
(see Figure 12).
5. Install and properly test gas log heater. Follow installation instructions included with the vent-free gas log heater that is being
installed.
Cabinet
Mantel
Gas Line
Access Hole
(Either Side of
Firebox)
Gas
Piping
Nailing
Flanges
Figure 10 - Attaching Firebox to Wall Studs
WARNING: Use only noncombustible mortar or
adhesives when overlapping the front facing with
noncombustible facing material.
INSTALLING FIREBOX USING OPTIONAL CUSTOM
BUILT MANTELS
WARNING: A qualified service person must install
firebox. Follow all local codes.
This firebox may be installed using a cabinet mantel against a wall in
your home. The firebox and cabinet mantel can be installed directly
on the floor. Mantels may be available from your retailer or custom
built for your home.
Figure 11 - Installing Cabinet Mantel (Mantel May Vary From
Illustration)
Figure 12 - Inserting Firebox Into Cabinet Mantel (Mantel May Vary
From Illustration)
Astria.US.com126770-01_B
11
Page 12
INSTALLATION Continued
MOSAIC MASONRY BRICK PANELS AND ESTATE REFRACTORY
PANELS INSTALLATION
WARNING
LIFTING HAZARD
SINGLE -PERSON LIFT COULD
CAUSE INJURY.
USE ASSISTANCE WHEN MOVING
OR LIFTING.
NOTE: A Mosaic Masonry brick kit or Estate liner kit is required for
use with your Venetian36, Venetian42, or Venetian50 Firebox. (Not
supplied, see pages 18 and 19 for models available).
MOSAIC MASONRY BRICK INSTALLATION
IMPORTANT: Installation of brick panels should be
done after the fireplace is placed in a permanent
location.
Note: Remove screen assemblies and all hardware components out
of the box prior to installation.
Slot
Hearth
Figure 14 - Slots for Firebrick Walls
4. Secure the firebrick wall using 2 of the retainers provided. The
bracket will slip underneath the metal lip on the top of the wall
and screw into the inner dome of the fireplace (Figure 15).
Right Face
Retaining
Bracket
INSTALLATION
1. Install bottom brick panel. Using at least two people, hold bottom brick panel by its side edges. Place the back edge of bottom
panel into the firebox first and carefully lower the front edge of
panel. Make sure bottom panel is centered in the firebox and
flush with the front of the fireplace. Be careful not to pinch your
fingers between the panel and firebox (Figure 13).
2. Install the left and right side leading bricks (Figure 13).
Side leading
brick Panel
Hearth Panel
Figure 13 - Installing Hearth and Leading Brick panels
Right Wall
Leading
Brick
Figure 15 - Installing Side Walls
5. Install the rear firebrick wall last. Place the wall face side down
on the hearth with the bottom of the wall toward the rear of the
firebox and the top toward the front of the fireplace. Tilt the wall
up toward the back of the firebox. Secure with 2 rear retaining
brackets provided (Figure 16, page 13).
6. It is recommended that the joints between all firebrick walls
be grouted for a more finished look, see grouting instructions. For more information and to watch a how to video go
to Astria.US.com and select Technical Support.
3. Install the left and right firebrick walls. Angle the wall into the fireplace opening and into the slots on the side of the hearth (Figure
21), then tilt the top of the panel toward the firebox surround.
Astria.US.com
126770-01_B12
Page 13
Figure 16 - Installing Rear Wall
K
INSTALLATION Continued
Retaining
Bracket
LEFT BRICK
PANEL
UPPER CORNER
BRACKET (2x)
REAR BRICK
PANEL
GROUTING INSTRUCTIONS
Note: Grouting material provided with mosaic brick kit
1. Moisten brick surface with damp sponge or spray bottle just prior
to application. When bricks are wet, any excess grout mixture
on bricks will easily wipe off.
2. In a heavy duty mixing bucket, add equal parts cement and sand.
Add enough water and mix together well using a power drill with
mixing wand attachment to a yogurt like consistency. Not adding
enough water can lead to grout falling out after burning.
3. The overall length of piping bag should be about 16". If the bag is
longer than 16", cut it down to size by removing end with larger
opening. This will make the bag easier to handle.
4. Put grout mixture into piping bag making sure the smaller
opening is downward and over a moist towel to avoid spilling.
Place a wet towel over the bucket making sure it is directly on
the surface of grout mixture. This will keep the mixture moist
and it will not dry out before use.
5. Grout all joints where two firebrick walls come together.
6. Using a trowel, remove excess grout mixture by moving trowel
in the direction of the joint. Grout mixture in the joint should now
be flush with brick surface. If not enough grout is applied into
each space, grout may fall out after burning.
7. Using a joint striker, smooth out grout line. Allow 72 hours before operating fireplace.
RIGHT BRIC
PANEL
ASH PANEL
BOTTOM
BRICK PANEL
Figure 17 - Installing Refractory Panels
INSTALLING FIREPLACE HOOD AND SCREENS
1. Attach hood to firebox using screws provided (see Figure 18).
1. Slide round end of screen rod into rings at top of screen. Attach one
push-on nut to end of rod before attaching last ring of screen.
2. Insert the round end screen rod into hole on the left and right side
of smoke shelf (Figure 19).
3. Mount flat end of screen rod with #10 x 5/8" to center of smoke
shelf.
4. Install other screen rod in same manner.
ESTATE REFRACTORY PANELS INSTALLATION
Note: Remove screen assemblies and all hardware components out
of the box prior to installation.
1. Install bottom brick panel. Using at least two people, hold bottom brick panel by its side edges. Place the back edge of bottom
panel into the firebox first and carefully lower the front edge of
panel. Make sure bottom panel is centered in the firebox and
flush with the front of the fireplace. Be careful not to pinch your
fingers between the panel and firebox.
2. Install rear brick panel. This panel has a top and bottom side.
To determine correct position, match up the pattern on the rear
panel with the right and left brick panels before installing. Make
sure rear panel is centered before continuing.
3. Install the right and left brick panels with the gas line knock outs
placed down toward the bottom refractory. Align the right an left
brick panels with the rear panel so the grout lines line up.
4. Install upper corner brackets and tighten set screws (see Figure
17).
Astria.US.com126770-01_B
Screws
Rating
Plate
Figure 18 - Screw and Hood Placement
Hole for
Screen Rod
Leading
Bricks
Figure 19 - Installing Fireplace Screen
13
Page 14
INSTALLATION Continued
GAS LINE INSTALLATION
WARNING: A qualified service person must connect
heater to gas supply. Follow all local codes.
IMPORTANT: See Connecting to Gas Supply in your log set owner’s
manual for details on gas hookup.
Note: Before you proceed, make sure your gas supply is turned off.
Use only a 1/2" black iron pipe and appropriate fittings.
1. Remove knockout indentation on refractory or firebrick wall lo-
cated above refractory hearth floor. Knockout indentation must be
firmly tapped with any solid object such as a 1/2" dowel until it is
released. Remove fragmented portions of refractory (see Figure
20).
2. Remove gas line cover plate located on either side of fireplace and
pull out insulation from gas line conduit sleeve. Save insulation for
reuse. Replace screws.
3. Run a 1/2" black iron gas line into fireplace through the rear at gas
line conduit sleeve (if using a raised platform, add height). Provide
sufficient gas line into fireplace chamber for fitting connection (see
Figure 21).
Note: Secure incoming gas line to wood framing to provide rigidity for
threaded end.
4. Repack insulation around gas line and into sleeve opening. Seal any
gaps between gas line and refractory knockout hole with refractory
cement or commercial furnace cement, Install the gas appliance or
cap-off gas line if desired.
A gas line or gas log lighter may be installed for the purpose of installing
a vent-free decorative gas appliance incorporating an automatic shutoff
device and complying with the Standard for Decorative Gas Appliances
for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning
Fireplaces, Draft No. 4 dated August, 1993.
When installing an unvented (vent-free) gas log set, only unvented
gas log sets which have been found to comply with the standard for
unvented room heaters, ANSI Z21.11.2 are to be installed in this
fireplace.
CAUTION: All gas piping and connections must be
tested for leaks after the installation is completed.
After ensuring that the gas valve is on, apply soap and
water solution to all connections and joints. Bubbles
forming show a leak. Correct all leaks at once. DO NOT
USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT
OPERATE ANY APPLIANCE IF A LEAK IS DETECTED.
LEAK TESTING SHOULD BE DONE BY A QUALIFIED
SERVICE PERSON.
Outside of
Fireplace
Gas Line
Conduit
Insulation
Gas
Conduit
Cover
Outside of
Fireplace
Gas Line
Conduit
Repack
Insulation
Remove
Knockout
Figure 20 - Gas Line Access
Incoming
1/2" Black
Iron Pipe
Seal
Opening
with
Refractory
Cement
Side Firebrick
Finished Side
1/2" Dowel
Brick with
Access Hole
Side Firebrick
Finished Side
Provide Enough
Threaded End for
Fitting Connection
Astria.US.com
Figure 21 - Gas Line Installation
126770-01_B14
Page 15
TECHNICAL SERVICE
REPLACEMENT PARTS Continued
You may have further questions about installation, operation, or
troubleshooting. Please contact your IHP dealer for any questions
or concerns a. When contacting your dealer please have your model
and serial numbers of your fireplace ready. You can also visit our
web site at Astria.US.com.
REPLACEMENT PARTS
See Pages 16 to 19 for a complete replacement parts list. Use only
parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor
or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.
2. The serial number of the fireplace.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the
installation or application of this fireplace, please contact your dealer.
IHP
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
Visit us at Astria.US.com
Purchase this accessory thru your IHP distributor or dealer.
CAT NO.MODELDESCRIPTION
OPTIONAL AIR KITS
F1091AK4FOutside Air Kit For Floor Installation
F1094AK4
Outside Air Kit For Sidewall Installation
ACCESSORIES
Astria.US.com126770-01_B
15
Page 16
9
36", 42", AND 50" MODELS
PARTS
8
7
6
5
19
22
1
14
11
15/16
10
12
13
4
11
20
20
21
3
18
Astria.US.com
17
11
2
14
12
13
14
15/16
126770-01_B16
Page 17
PARTS
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on
page 15 of this manual.
WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved
by IHP. Use of non-approved parts can result in poor performance and safety hazards.
RP114913-01 REAR REFRACTORY SPACERS•••2
** Not a field replaceable part.
Venetian36
F0546
Venetian42
F0547
Venetian50
F0548QTY.
Astria.US.com126770-01_B
17
Page 18
PARTS
MOSAIC MASONRY BRICK KITS
A Mosaic Masonry brick kit or Estate liner kit is required for use with your Venetian36, Venetian42, or Venetian50 Firebox. Catalog numbers
are included for convenience. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual.
WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved
by IHP. Use of non-approved parts can result in poor performance and safety hazards.
WARNING
LIFTING HAZARD
SINGLE -PERSON LIFT COULD
CAUSE INJURY.
USE ASSISTANCE WHEN MOVING
OR LIFTING.
IMPORTANT: Installation of brick panels should be
done after the fireplace is placed in a permanent
location.
CATALOG NO. MODEL NO. DESCRIPTION
F0334Mosaic36M2Red Full Stacked
F0335Mosaic36M4Red Split Stacked
F0336Mosaic36M2Ivory Full Stacked
F0337Mosaic36M4Ivory Split Stacked
F0338Mosaic36M3Red Herringbone Full
F0339Mosaic36M5Red Herringbone Split
F0340Mosaic36M3Ivory Herringbone Full
F0341Mosaic36M5Ivory Herringbone Split
F0342Mosaic42M2Red Full Stacked
F0343Mosaic42M4Red Split Stacked
F0344Mosaic42M2Ivory Full Stacked
F0345Mosaic42M4Ivory Split Stacked
F0346Mosaic42M3Red Herringbone Full
F0347Mosaic42M5Red Herringbone Split
F0348Mosaic42M3Ivory Herringbone Full
F0349Mosaic42M5Ivory Herringbone Split
F0350Mosaic50M2Red Full Stacked
F0351Mosaic50M4Red Split Stacked
F0352Mosaic50M2Ivory Stacked Full
F0353Mosaic50M4Ivory Split Stacked
F0354Mosaic50M3Red Herringbone Full
F0355Mosaic50M5Red Herringbone Split
F0356Mosaic50M3Ivory Herringbone Full
F0357Mosaic50M5Ivory Herringbone Split
Astria.US.com
126770-01_B18
Page 19
PARTS
ESTATE LINER KITS
An Estate liner kit or Mosaic Masonry brick kit is required for use with your Venetian36, Venetian42, or Venetian50 Firebox. Catalog numbers
are included for convenience. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual.
WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved
by IHP. Use of non-approved parts can result in poor performance and safety hazards.
WARNING
LIFTING HAZARD
SINGLE -PERSON LIFT COULD
CAUSE INJURY.
USE ASSISTANCE WHEN MOVING
OR LIFTING.
IMPORTANT: Installation of brick panels should be
done after the fireplace is placed in a permanent
location.
Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria® brand gas fi replace ("Product") to be free from defects in materials and workmanship at
the time of manufacture. The Product body and fi rebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage
only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Lifetime Warranty period and
while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates,
as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited
Lifetime Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six
months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following
the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be
provided. The Product body and fi rebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from
this Limited Lifetime Warranty. The following do not carry the Limited Lifetime Warranty but are warranted as follows:
Burner – Repair or replacement for fi ve years from the date of installation
Gas components & electrical components – Repair or replacement for one year from the date of installation
Gaskets – Repair or replacement for one year from the date of installation
Gold & nickel plating - Replacement for two years from date of installation. Excludes tarnishing
Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component
Light bulbs & batteries – Replacement for 90 days from the date of installation
Logs – Replacement for fi ve years from the date of installation against thermal breakage only
Optional blowers & remote controls – Repair or replacement for one year from the date of installation
Optional glass doors & optional glass accessories – Repair or replacement for 90 days from the date of installation
Optional surrounds – Stone/Natural Materials: Replacement for one year against cracking or breakage due to thermal stress. Other Materials: Replacement for one
year. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit
Tempered Glass -Replacement for one year from the date of installation
Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures
and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product;
(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.
IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions
which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by venting
confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied,
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after
repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a particular
use or purpose, and there is no implied condition of fi tness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited
Lifetime Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefi ts and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without fi rst obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.