Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900079-01.
P900079-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
WARNINGAVERTISSEMENTAVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE
AVANT D’Y TOUCHER.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA TOCAR
EL VIDRIO CALIENTE.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
s Do not try to light any appliance.
s Do not touch any electrical switch; do not
use any phone in your building.
s Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
s If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
NE PERMETTEZ JAMAIS À UN ENFANT DE
TOUCHER LA SURFACE VITRÉE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
s Ne pas tenter d’allumer d’appareil.
s Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
s Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
s Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
General Information
900079-00, 02/2014
Innovative Hearth ProductsAstria™ Sirius Linear Direct-Vent Gas Fireplaces
2
Afind'éviterdevous
brûlergravementoude vousblesser,installez unegrilleouunebarrière physiquepourempêcher tout contact direct avec la vitre.
Suivezlesinstructionsdesécurité
ci-dessousetveillezàcequetousles membresdevotrefamillesoientconscients du danger de brûlure encouru:
sLessurfacesdevotrefoyerdeviennent
EXTRÊMEMENTCHAUDES!
sLa vitre située à l'avant du
foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact.
sTenez les enfants à l'écart
du foyer lorsqu'il fonctionne. Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d'éviter qu'ils ne soient en contact avec la vitre.
sTeneztouslesvêtements,les
meubles,l'essenceettoutautreliquide inflammable à l'écart du foyer.
sMême après fermeture du gaz,
les surfaces du foyer restent extrêmement chaudes.
Veillez à coller les Étiquettes de mise
en garde relatives à la sécurité d'utilisation à l'endroit où vous
utilisez le foyer, pour rappeler à tous les utilisateurs les dangers liés aux températures élevées (Page44).
Lisez L’information de sûreté
importante (Page44).
Instaleunamallaobarrerafísicaparaevitar
elcontactodirectoconelvidrioyprevenir las quemaduras y lesiones graves.
Siga las instrucciones de seguridad
a continuación y asegúrese de que todos en su hogar sepan acerca de este peligro de quemadura:
s¡Las superficies de la chimenea
se ponen MUY CALIENTES!
sEl vidrio delante de la
chimenea alcanza temperaturas EXTREMADAMENTE ALTAS y puede causar quemaduras graves si se toca.
sMantengaalosniñosalejadosde
lachimeneaenfuncionamiento. Superviseenformacercanaalos niñosencualquiercuartodondehaya unachimeneafuncionandopara impedir el contacto con el vidrio.
sMantenga la ropa, mobiliario,
gasolina y otros líquidos inflamables alejados de la chimenea.
sAún después de haber apagado
el gas, las superficies de la chimenea permanecen extremadamente calientes.
Asegúrese de colocar las Etiquetas
de advertencia de seguridad de operación en el lugar donde
enciende la chimenea, para que todos recuerden los peligros asociados con las altas temperaturas (Página44).
Lea Información importante de
seguridad (Página4).
Seguridadysu
chimenea
La sécurité et
votre foyer
[FRENCH][ENGLISH]
[SPANISH]
SafetyandYour
Fireplace
To prevent severe
burns and injuries, install a screen or physical barrier to prevent direct contact with the glass.
Follow the safety instructions
below and be sure everyone in your household understands this burnhazard:
sThe surfaces on your fireplace get
EXTREMELY HOT!
sThe glass on the front of the
fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched.
sKeep children away from an
operating fireplace. Closely supervise children in any room where a fireplace is operating to prevent contact with glass.
sKeep clothing, furniture,
gasoline, and other flammable liquids away from the fireplace.
sEven after the gas is turned
off, fireplace surfaces remain extremely hot.
Be sure to attach the enclosed
Safety-in-Operation Warnings where you turn on your fireplace, to help remind everyone of the dangers associated with high temperatures (Page44).
Read Important Safety Information
(Page4)
Allpartsofyour
IHPfireplaceget
EXTREMELY HOT!
Touteslespartiesdevotre
foyerIHPdeviennent
EXTRÊMEMENT CHAUDES !
¡Todaslaspartesdela
chimeneaIHPseponen
MUY CALIENTES!
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS!
Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety
information. Following these safety, care, and operation instructions will help ensure many years of dependable and
enjoyable service from your fireplace.
General Information
900079-00, 02/2014
Look for the EnerGuide
Gas Fireplace Energy
Efficiency Rating in this manual.
Based on CSA P.4.1-02
Please read and understand these instructions before installing,
operating, or servicing this product.
General Information
Important Safety Information ............................................................4
Fireplace Installation, Operation, and Maintenance Notices ...............5
We recommend that our
gas hearth products be
installed and serviced by
professionals who are
certied in the U.S. by the
National Fireplace Institute®
(NFI) as NFI Gas Specialists.
If necessary, Install the Firebox Floors.............................................37
If necessary, Install the Firebox Liners.............................................37
Install the Glass Media ....................................................................38
Install the Baffle ...............................................................................38
Install the Glass Door ......................................................................38
Adjust the Air Shutter to Ensure Proper Flame Appearance .............38
Install the Finishing Materials ..........................................................40
Install the Wall Switch Receiver .......................................................43
Initialize the Remote Control System ...............................................43
Attach the Safety-in-Operation Warnings.........................................44
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
General Information
900079-00, 02/2014
GENERAL INFORMATION
IMPORTANT SAFETY INFORMATIONL’information de sûreté importanteInformación importante de seguridad
WARNING AVERTISSEMENT ADVERTENCIA
Do not operate appliance with the
glass front removed, cracked or
broken.
Do not use this fireplace if any part has
been under water. Immediately call a
qualified service technician to inspect the
fireplace and to replace any part of the
control system and any gas control which
has been under water.
Due to high temperatures, the fireplace
should be located out of traffic and away
from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperature
and should stay away to avoid burns or
clothing ignition.
Clothing or other flammable material
should not be placed on or near the
fireplace.
Young children should be carefully
supervised when they are in the same
room as the fireplace. Toddlers, young
children, and others may be susceptible
to accidental contact burns. A physical
barrier is recommended if there are
at-risk individuals in the house. To
restrict access to a fireplace or stove,
install an adjustable safety gate to keep
toddlers, young children, and other atrisk individuals out of the room and away
from hot surfaces.
Any safety screen or guard removed for
servicing a fireplace must be replaced
prior to operating the fireplace.
Installation and repair should be done
by a qualified service person. The
fireplace should be inspected before use
and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint
from carpeting, bedding material, et
cetera. It is imperative that control
compartments, burners, and circulating
air passageways of the fireplace be kept
clean (Maintenance on Page 58).
[English][French][Spanish]
Ne pas utiliser l’appareil si le
panneau frontal en verre n’est pas
en place, est craqué ou brisé.
Ne pas utiliser cet appareil s’il a été
plongé, même partiellement, dans l’eau.
Appeler un technicien qualifié pour
inspecter l’appareil et remplacer toute
partie du système de commande et toute
commande qui a été plongée dans l’eau.
En raison des températures élevées,
l’appareil devrait être installé dans un
endroit où il y a peu de circulation et loin
du mobilier et des tentures.
Les enfants et les adultes devraient être
informés des dangers que posent les
températures de surface élevées et se
tenir à distance afin d’éviter des brûlures
ou que leurs vêtements ne s’enflamment.
On ne devrait pas placer de vêtements
ni d’autres matières inflammables sur
l’appareil ni à proximité.
Les jeunes enfants devraient être
surveillés étroitement lorsqu’ils se
trouvent dans la même pièce que
l’appareil. Les tout petits, les jeunes
enfants ou les adultes peuvent subir des
brûlures s’ils viennent en contact avec
la surface chaude. Il est recommandé
d’installer une barrière physique si des
personnes à risques habitent la maison.
Pour empêcher l’accès à un foyer ou à un
poêle, installez une barrière de sécurité
; cette mesure empêchera les tout petits,
les jeunes enfants et toute autre personne
à risque d’avoir accès à la pièce et aux
surfaces chaudes.
Tout écran ou protecteur retiré pour
permettre l’entretien de l’appareil doit
être remis en place avant de mettre
l’appareil en marche.
L’installation et la réparation devrait
être confiées à un technicien qualifié.
L’appareil devrait faire l’objet
d’une inspection par un technicien
professionnel avant d’être utilisé et au
moins une fois l’an par la suite. Des
nettoyages plus fréquents peuvent être
nécessaires si les tapis, la literie, et
cetera produisent une quantité importante
de poussière. Il est essentiel que les
compartiments abritant les commandes,
les brûleurs et les conduits de circulation
d’air de l’appareil soient tenus propres
(Page 58).
No opere el artefacto con el frente
de vidrio quitado, agrietado o roto.
No use este artefacto si alguna de sus
partes ha estado bajo agua. Llame
de inmediato a un técnico de servicio
calificado para que inspeccione el
artefacto y reemplace cualquier parte del
sistema de control y cualquier control de
gas que haya estado bajo agua.
Debido a las altas temperaturas, el
artefacto debe situarse fuera de las
áreas de tráfico y lejos del mobiliario y
cortinas.
Se debe alertar a los niños y adultos
sobre los peligros de las altas
temperaturas en la superficie y que
se mantengan alejados para evitar
quemaduras o ignición de la ropa.
No debe colocarse ropa u otros
materiales inflamables sobre y cerca del
artefacto.
Se debe supervisar de cerca a los niños
cuando estén en el mismo cuarto que
el artefacto. Los niños pequeños, los
jóvenes y otras personas pueden ser
susceptibles a quemaduras por contacto
accidental. Se recomienda instalar
una barrera física si hay personas en
riesgo en la casa. Para restringir el
acceso a una chimenea o estufa, instale
una puerta de seguridad ajustable
para mantener a los niños pequeños,
jóvenes y otras personas en riesgo fuera
del cuarto y lejos de las superficies
calientes.
Cualquier malla o resguardo de seguridad
quitado para dar servicio a un artefacto,
debe reinstalarse antes de operar
el artefacto.
Una persona de servicio competente
debe realizar la instalación y reparación.
Una persona de servicio profesional
debe inspeccionar el artefacto antes
de usar al menos una vez por año. Se
puede requerir limpieza más frecuente
debido a la pelusa excesiva del
alfombrado, del material de cobijas,
etc. Es imprescindible mantener limpios
los compartimientos de control, los
quemadores y los pasajes de circulación
del aire del artefacto (Página 58).
4
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
FIREPLACE INSTALLATION, OPERATION, AND MAINTENANCE NOTICES
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION, AND LISTINGS OF THIS UNIT.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to this manual. For assistance or additional information consult a
qualified installer, service agency or the gas supplier.
AVERTISSEMENT
Une installation, un réglage,une modification, une réparation ou un entretien mal effectué
peut causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui
accompagne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez
un installateur, un technicien agréé ou le fournisseur de gaz.
WARNING
General Information
900079-00, 02/2014
Failure to comply with these installation instructions will result in an improperly installed
and operating appliance, voiding its warranty. Any change to this appliance and/or its
operating controls is dangerous.
5
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Clothing or other flammable material should not be placed on or near the appliance.
On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
Improper installation or use of this appliance can cause serious injury or death from fire, burns,
explosion or carbon monoxide poisoning.
Hot while in operation. Do not touch. Severe Burns may result. Keep children, clothing
furniture, gasoline and other liquids having flammable vapors away.
General Information
900079-00, 02/2014
WARNING
AVERTISSEMENT
WARNING
CAUTION
ATTENTION
L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures
graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres
liquides produisant des vapeur inflammables loin de l’appareil.
NOTE:
s Only accessory kits supplied by the manufacturer shall be used in the installation of this appliance.
s These fireplaces are designed as supplemental heaters, and are not to be used as the primary heat source when
installed in a dwelling.
s Provide adequate clearances around air openings and adequate accessibility clearance for service and proper
operation. Never obstruct the front or back openings of the fireplace.
s These fireplaces are designed to operate on natural or propane gas only. The use of other fuels or combination of
fuels will degrade the performance of this system and may be dangerous.
s These fireplaces must not be connected to a chimney or flue serving a separate solid fuel burning fireplace.
s These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances.
s Only trim kit(s) supplied by the manufacturer shall be used in the installation of this fireplace.
Remarqué :
s Seules les trousses de garniture fournies par le fabricant doivent être utilisées pour l’installation de cet appareil.
6
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
INSTALLATION
PACKAGING
All models include
The assembled vented gas fireplace heater is packaged with:
s Literature Kit (Installation and Operation Instructions (this manual), and Safety-In-Operation Warning Labels)
s Vent restrictor assembly
s (1) Non-combustible fiber board
s Handheld remote control (transmitter) with (3) AAA batteries
s Remote control receiver (wall switch) assembly with (4) AA batteries
s Glass media kit, black
Optional accessories
s Surround kit
s Gas conversion kit
INTRODUCTION
These vented gas fireplace heaters are direct-vent (top vent only), sealed combustion, air-circulating gas fireplaces
designed for residential applications. Direct-vent appliances operate with the combustion chamber isolated from the
indoor environment. All air for combustion is brought in from the outside, and exhaust gases are vented through the
same direct-vent, coaxial (intake/exhaust) vent system.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or fuel combinations
will degrade the performance of this system, may be dangerous, and may void the warranty.
Electronic fireplaces are designed with an electronic intermittent pilot ignition system. Electrical power (110 Vac line
voltage) is recommended to operate the fireplace; however, AA batteries (not provided) can be used for full-time
operation or as a backup in case of a power outage.
Batteries will operate the flame ON/OFF function only. Electrical power is required to operate the optional blower.
A remote control system is included with all models and provides remote ON/OFF flame control (manual adjustment
of the gas valve settings is not possible).
Installation
900079-00, 02/2014
NOTE: Installation and repair should be done by a qualified service person. The fireplace should be inspected before
use and at least annually by a professional service person. More frequent cleaning may be required due to excessive
lint from carpeting, bedding material, etcetera. It is imperative that control compartments, burners and circulating air
passageways of the fireplace be kept clean.
Remarqué : L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire
l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité
importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil soient tenus propres.
NOTE: Diagrams and illustrations are not necessarily shown to scale.
7
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Approved Vent Components
These fireplaces are designed, tested and listed for operation and installation with the following vent
components only:
s Secure Vent® Direct-Vent System Components,
s Secure Flex® Flexible Vent Components, and
s Z-FLEX® Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster
Canada Limited.
Use only the correct size venting (4 1/2” inner and 7 1/2” outer).
These approved vent system components are labeled for identification. DO NOT use any other manufacturer’s vent
components with these fireplaces.
Codes and Standards
These fireplaces comply with National Safety Standards and are tested and listed by Intertek (Report No.
100404899PRT-001) to ANSI Z21.88 (in Canada, CSA-2.33), and CAN/CGA-2.17-M91 (CSA P4.1) in both USA and
Canada, as vented gas fireplace heaters.
These fireplaces are listed for installation in bedrooms, aftermarket mobile homes, and manufactured homes.
The installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54—latest edition (In Canada, the current CAN/CGA-B149.1 installation code).
The fireplace, when installed, must be electrically grounded and wired in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70—latest edition, or the Canadian Electrical
Code, CSA C22.1—latest edition.
Installation
900079-00, 02/2014
BTU Input
Gas Pressure
Tabl e 1: Input Rate, Gas Valves
Models
42”22,00020,000
54”30,00030,000
Natural GasPropane (field converted)
Input Rate (BTU/HR)
Tabl e 2: Thermal Efficiency (%)
Model
42”66.754.269.659.4
54”71.963.272.165.5
* AFUE is a measurement of the US Department of Energy
** P4 (EnerGuide) is a measurement of the Canadian Office of Energy Efficiency.
The control valves have a 3/8” (10 mm) NPT thread inlet and outlet side of the valve (Figure 1).
8
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Figure 1: Electronic Gas Valve
Line (IN) Test Port
Manifold (OUT) Test Port
Orange Wire
(from DFC Wire
Harness)
Main Gas Inlet
3/8" NPT
The SIT gas valve in this fireplace has a 3/8” NPT thread main gas inlet and outlet. Test gauge connections are
provided on the front of the electronic gas control valve (identified IN for the inlet and OUT for the manifold side).
Figure 2: Accessing the gas valve
Installation
900079-00, 02/2014
Green Wire
(from DFC Wire Harness)
Pressure
Regulator
Tower
Yellow Ground Wire
(from DFC Wire Harness)
Glass Door Assembly
(Lower Right Corner)
Air Shutter
Adjustment Lever
Battery Backup Holder
(attached to bracket with cable)
Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down
regulators to reduce the pressure to safe levels.
Using a propane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery, which can cause
sooting, severe delayed ignition, or other malfunctions (see NPFA 58).
Any damage as a result of insufficient tank size or other improper installation is NOT covered under the
limited warranty.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during
any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
9
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Orifice Sizes—Sea Level to High Altitude
These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level
using the standard burner orifice sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualified
service technician.
Tabl e 5: Burner Orifice Sizes, Elevation 0–4500 ft ( 0–1372 m)
Model
42”
54”
* Standard size installed at factory
Deration
At elevations above 4500 ft, the amount of BTU fuel value delivered must be reduced by either:
s Using gas that has been derated by the gas company.
s Changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the
(USA) National Fuel Gas Code NFPA 54/ANSI Z223.1—latest edition or, in Canada, the CAN/CGA-B149.1 codes—
latest edition.
NOTE: Flame breadth, height and width will diminish 4% for every 1,000 ft of altitude.
IN CANADA—CAN/CGA-2.17-M91 (HIGH ALTITUDE):
THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER’S AUTHORIZED REPRESENTATIVE,
IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, PROVINCIAL OR TERRITORIAL
AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/
CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
Natural Gas
drill size
#43 (0.089”)*
Cat. No. 99K7501
#37 (0.104”)*
Cat. No. 24M10
Installation
900079-00, 02/2014
Propane
drill size
#55 (0.052”)*
Cat. No. 19L52
0.063”*
Cat. No. LB-37G00
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
These fireplaces are approved for installation in the U.S. state of Massachusetts if the following additional
requirements are met:
s Install this fireplace in accordance with Massachusetts Rules and Regulations 248 C.M.R..
s Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts.
s The flexible gas line connector used shall not exceed 36” (914 mm) in length.
s The individual manual shutoff must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, horizontal terminations installed less than seven (7) ft above the finished
grade must comply with the following additional requirements:
s A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level
where the gas fireplace is installed. The carbon monoxide detector must comply with NFPA 720, be ANSI/UL
2034 listed and be ISA certified.
sA metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height
of eight (8) ft above grade and be directly in line with the horizontal termination. The sign must read, in print size no
less than one-half (1/2) inch in size, GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks around your fireplace with noncombustible material and wherever cold
air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on
which fireplace rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed
with unfaced fiberglass insulation. Caulk the firestop only where the pipe penetrates an outside wall, attic, or other
unconditioned space.
NOTE: Do not use loose, or blown-in insulation in the cavity surrounding the fireplace.
If the fireplace is being installed on a cement slab in cold climates, a sheet of plywood or other raised platform can
be placed underneath to prevent conduction of cold transferring to the fireplace and into the room. It also helps to
sheetrock inside surfaces and tape for maximum air tightness and caulk firestops.
10
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
MANUFACTURED HOME REQUIREMENTS
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements
locaux le permettent.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil ne
peut être converti à d’autres gaz, sauf si une trousse de conversion est utilisée.
Ensure that the cross members are not cut or weakened during installation. The structural
integrity of the manufactured home floor, wall, and ceiling / roof must be maintained.
This appliance must be grounded to the chassis of the manufactured home in accordance
with local codes or in the absence of local codes, with the National Electrical Code ANSI /
NFPA 70—latest edition or the Canadian Electrical Code CSA C22.1—latest edition.
Installation
900079-00, 02/2014
CAUTION
CAUTION
LOCATION
In selecting the location, the aesthetic and functional use of the fireplace are primary concerns. However, vent
system routing to the exterior and access to the fuel supply are also important. The fireplace may be located on or
near conventional construction materials. See Construct the Fireplace Framing on Page 16 for more information.
Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.
En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de
circulation et loin du mobilier et des tentures.
The location should also be free of electrical, plumbing or other heating/air conditioning ducting.
Be aware that this is a heat producing fireplace. Objects placed above the unit are exposed to elevated temperatures.
Do not insulate the space between the fireplace and the area above it.
Figure 3: Typical Locations and Venting
Top Vent
Top Vent
Recessed
Installation
Top Vent
Vertical Vent
(Top Vent)
Top VentTop Vent
Top Vent
Horizontal Vent
(Top Vent)
11
Innovative Hearth Products
12
X
Roof pitch is X/12
2 ft
minimum
2 ft minimum
Lowest
discharge
opening
H*
*H = minimum height from roof to
lowest discharge opening of vent
Horizontal overhang
Vertical
wall
Vent
termination
Storm collar
Concentric
vent pipe
Flashing
1” (25.4 mm) minimum
clearance to combustibles
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
VENT TERMINATION CLEARANCES
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting
according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or
the current standards of CAN/CGA-B149.1 in Canada.
Vertical Vent Termination Clearances
Terminate multiple vent terminations according to the installation codes listed above and Figure 4.
Figure 4: Multiple Terminations
Terminate single vent caps relative to building components according to Table 6 and Figure 4.
Tabl e 6: Termi na ti on H ei ghts fo r Ve nts a bo ve F la t or Sl op ed R oo fs ( NFPA 5 4 / ANS I Z2 23 .1 )—Gas Vent Rule
Installation
900079-00, 02/2014
12”
(305 mm)
minimum
Roof PitchTermination Height *
Flat to 6/121.0 ft (0.3 m)
6/12 to 7/121.25 ft (0.38 m)
7/12 to 8/121.5 ft (0.46 m)
8/12 to 9/122.0 ft (0.61 m)
9/12 to 10/122.5 ft (0.76 m)
10/12 to 11/123.25 ft (0.99 m)
11/12 to 12/124.0 ft (1.22 m)
12/12 to 14/125.0 ft (1.52 m)
14/12 to 16/126.0 ft (1.83 m)
16/12 to 18/127.0 ft (2.13 m)
18/12 to 20/127.5 ft (2.29 m)
20/12 to 21/128.0 ft (2.44 m)
Horizontal Vent Termination Clearances
The horizontal vent termination must have a minimum of 6” (152 mm) clearance to any overhead combustible
projection of 2 1/2” (64 mm) or less (Figure 5). For projections exceeding 2 1/2” (64 mm) (Figure 5). For additional
vent location restrictions refer to Table 7.
All horizontal terminations may be located as close as 6” (152mm) to any (non-combustible and combustible)
exterior sidewall. This distance may be decreased to 2” (51mm) for noncombustible exterior sidewalls with
SV4.5HT-2 termination (Table 21).
Figure 5: Horizontal Vent Termination Clearances
Combustible projection
2 1/2” or less in length
Combustible projection
greater than 2 1/2” in length
12
Ventilated
soffit
18”
(457 mm)
Unventilated
soffit
12”
(305 mm)
Termination kit
6
(152)
6”
Termination kit
NOTE: See Figure 27
on Page 30 for
exterior wall recess
allowances for the
SV4.5HT-2 termination.
Innovative Hearth Products
(TERMINATION PROHIBITED)
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Tabl e 7: Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors
Inside Corner
D
E
V
B
L
C
F
V
B
TERMINATION CAP
V
Fixed
Closed
Openable
V
Openable
V
B
A
AIR SUPPLY INLET
X
Fixed
Closed
J
B
V
B
X
G
GAS METERRESTRICTED AREA
H
G
See Table 6
I
M
G
V
Balcony with No Side WallVBalcony with Perpendicular Side Wall
G
V
G
V
K
V
X
A
M
V
U.S. Installation **Canadian Installation *
A Clearance above grade, veranda, porch, desk, or balcony12” (300 mm) **12” (300 mm) *
B Clearance to window or door that may be opened6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
9” (230 mm)
for fireplaces > 10,000 Btu/h (3 kW), and < 50,000 Btu/h
(15 kW),
12” (300 mm)
for fireplaces > 50,000 Btu/h (15 kW) **
C Clearance to permanently closed window9” (229 mm)
recommended to prevent window condensation
D Vertical clearance to ventilated soffit located above the
18” (458 mm)18” (458 mm)
termination within a horizontal distance of 18” (458 mm)
E Clearance to unventilated soffit12” (305 mm)
30” (760 mm) to vinyl soffit
F Clearance to outside corner5” (127 mm)
minimum
G Clearance to inside corner2” (51 mm) minimum2” (51 mm) minimum
H Clearance to each inside of center line extended above
meter / regulator assembly
36” (910 mm)
within a height of 15 ft above the meter / regulator assembly **
I Clearance to service regulator vent outlet36” (910 mm)**36” (910 mm)*
J Clearance to nonmechanical air supply inlet to building or
the combustion air inlet to any other fireplace
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
9” (230 mm)
for fireplaces > 10,000 Btu/h (3 kW) and < 50,000 Btu/h (15 kW),
12” (300 mm)
for fireplaces > 50,000 Btu/h (15 kW)**
K Clearance to a mechanical air supply inlet36” (910 mm) above if within 10 ft (3 m) horizontally **72” (1830 mm) *
L Clearance above paved sidewalk or paved diveway located
84” (2130 mm) ‡84” (2130 mm) ‡
on public property
M Clearance under veranda, porch, deck or balcony12” (300 mm) *‡12” (300 mm) *‡
N Depth of alcove (maximum)72” (1830 mm) **72” (1830 mm) *
O Clearance to termination (alcove)6” (15.2 mm) **6” (15.2 mm)*
P Width of alcove (minimum)36” (910 mm) **36” (910 mm) *
Q Clearance to combustible above (alcove)18” (457 mm) **18” (457 mm) *
*
In accordance with the current CSA-B149.1 National Gas And Propane Installation Code
**
In accordance with the curent ANSI Z223.1/NFPA 54 National Fuel Gas Codes
‡
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
*‡
Only permitted if veranda, porch, deck, or balcony is fully-open on a minimum two sides beneath the floor
Outside CornerRecessed Location
V
F
M
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
12” (300 mm)
for fireplaces > 10,000 Btu/h (3 kW)
12” (305 mm)
recommended to prevent
window condensation
12” (305 mm)
30” (760 mm) to vinyl soffit
5” (127 mm)
minimum
36” (910 mm)
within a height of 15 ft above the meter /
regulator assembly *
6” (150 mm)
for fireplaces < 10,000 Btu/h (3 kW),
12” (300 mm)
for fireplaces > 10,000 Btu/h (3 kW)
Installation
900079-00, 02/2014
P
N
O
Q
V
13
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
MINIMUM CLEARANCES TO COMBUSTIBLES
Fireplace And Vent Clearances
The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the
following exceptions:
s When unit is recessed, the side walls surrounding the unit must not extend beyond unit front edge (Figure 6).
s When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend
beyond the front edge of the unit (Figure 6).
Tabl e 8: Minimum Clearances *
From Bottom of Unit to Ceiling65” (1651 mm)
Front Service Clearance—
clearance immediately in front of viewing area(s)
* 3” (76 mm) above any horizontal/inclined vent component.
** See Page 19 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it.
Back
Sides
Top Spacers0” (0 mm)
Floor0” (0 mm)
Vent
1/2” (13 mm) to wrapper
0” (0 mm) to Spacers
1/2” (13 mm) to wrapper
0” (0 mm) to Spacers **
3” (76 mm)—Top *
1” (25.4 mm)—Sides and Bottom
36” (914 mm)
Installation
900079-00, 02/2014
Hearth Extension
A hearth extension is not required with this fireplace. If a hearth extension is used, do not block the lower control
compartment door. Any hearth extension used is for appearance only and does not have to conform to standard
hearth extension installation requirements.
Shelf Height
The venting attached to the top vent should be routed in a way to minimize obstructions to the space above the
fireplace. Do not insulate the space between the fireplace and the area above it (Table 9). The minimum height from
the base of the fireplace to the underside of combustible materials used to construct a utility shelf in this fashion is
shown in Table 9.
NOTE: This is a heat-producing appliance. Objects placed above the unit are exposed to elevated temperatures.
* 6” straight vent section required before 90° elbow
** Includes 3” clearance to combustibles required above vent components
Top Vent with one 90° Elbow
Secure Vent
®
Secure Flex® (flex elbow)
Shelf Height
(see table)
No combustibles
or insulation
in the shaded
area between
the appliance
and the shelf
above it.
14
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Wall Finishes / Surrounds / Mantels
Clearances to combustible mantels vary according to mantel depth (Figure 6).
Mantels constructed of non-combustible material may be installed at any height above the appliance opening; however, do
NOT allow anything to hang below the top edge of the fireplace door.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above
the fireplace.
NOTE: To a vo id h ea t- relat ed fi ni sh d amage , us e fin is h mater ia ls r at ed 175 °F, or h ig he r, on the un de rs id e of the mantel.
NOTE: The factory-supplied non-combustible fiber board MUST be installed around the fireplace opening.
Figure 6: Combustible Side ClearancesFigure 7: Mantel Height
At 14” minimum
side wall
clearance, a
combustible wall
can project to
any length.
14
14”
(356)
(356 mm)
At 8 1/4” side
wall clearance, a
combustible wall
can project 12”
8 1/4”
8-1/4
(209 mm)
(209)
Installation
900079-00, 02/2014
Top View of
Fireplace
o
45
5(127)
(127 mm)
12(305)
(305 mm)
17(431)
(431 mm)
Combustible materials
allowed in shaded area
5”
“Safe Zone”.
Combustible walls
shown in dark gray
12”
Combustible mantel
legs may project
beyond either side of
the fireplace opening
as long as they are kept
within the shaded area
17”
illustrated here.
28 (711)
26 (660)
24 (610)
22 (559)
20 (508)
18 (457)
in. (mm)
12
(305)
Mantel depth
(203)
10
(254)
8
6
(152)
4
(102)
(51)
2
Fireplace
INSTALLATION PREPARATION
The fireplace is shipped with all gas controls and components installed and pre-wired. Before installing the fireplace,
follow these steps:
1. Remove and retain the shipping carton.
2. Confirm receipt of required items listed in Packaging on Page 7.
3. Retrieve the non-combustible fiber board from behind the fireplace, and set aside in a safe location for
later installation.
4. If not already done, remove the glass door (Page 56), and set aside in a secure location for later reinstallation.
NOTE: Place the glass door on the shipping carton to protect its surface.
5. Remove the modesty panel. Set aside in a secure location for later installation.
15
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
INSTALLATION SEQUENCE
The typical sequence of installation is outlined below; however, each installation is unique and may result in
variations to the steps described.
See the pages referenced in the following steps for detailed instructions.
Framing
1. Construct the Fireplace Framing (Page 16).
2. Prepare the Fireplace Top Spacers (Page 18).
3. Route the Gas Supply Line into the Fireplace (Page 18).
4. Rough in the Electrical Supply, if Needed (Page 19).
5. Prepare the Fireplace Nailing Flanges (Page 19).
6. Place the Fireplace in the Framing and Secure (Page 19).
Venting
7. Select a Horizontal or Vertical Vent System (Page 20).
8. Install the Vent Restrictor (if necessary) (Page 20).
9. Install the Vent System (Page 23).
Electrical Connection
10. Complete the Field Wiring (Page 34).
Gas Connection
11. Connect the Gas Line (Page 36).
12. Verify Proper Fireplace Operation (Page 37).
Finishing
13. Construct the Fireplace Framing (Page 54).
14. Construct the Fireplace Framing (Page 55).
15. Install the Glass Media (Page 55).
16. Install the Baffle (Page 38).
17. Install the Glass Door (Page 56).
18. Adjust the Air Shutter to Ensure Proper Flame Appearance (Page 38).
19. Install the Finishing Materials (Page 40).
20. Install the Wall Switch Receiver (Page 43).
21. Initialize the Remote Control System (Page 43).
22. Attach the Safety-in-Operation Warning Labels (Page 43).
Installation
900079-00, 02/2014
1. Construct the Fireplace Framing
1. Frame the fireplace as illustrated in Ta bl e 10. All framing details must allow for a minimum clearance to combustible
framing members as shown in Tabl e 8. Steel studs are strongly recommended where exposed to heat.
2. Mount the fireplace on a fully supported base extending the full width and depth of the unit. If installed on
combustible materials, such as carpeting, vinyl tile, or combustible material other than wood flooring, the
appliance shall be installed on a metal or wood panel extending the full width and depth of the fireplace.
NOTE: Headers may be in direct contact with the fireplace top standoff spacers when they are bent up vertically,
maintaining the 4 3/8” clearance to the fireplace top, but must not be supported by them or notched to fit around
them. All construction above the fireplace must be self-supporting. DO NOT use the fireplace for structural support.
16
Installation
900079-00, 02/2014
Innovative Hearth ProductsAstria™ Sirius Linear Direct-Vent Gas Fireplaces
17
Table10:Fireplace Framing Dimensions
Modelabcd
b
7
(178)
5-1/8
(130)
12-1/8
(308)
10-1/2
(267)
65
(1651)
e
c
d
inches
(millimeters)
CEILING
f
~
a
1/2 ofA
42”
54 3/4
1366
18 1/2
470
37
940
44 3/8
1127
54”
65 3/4
1670
18 1/2
470
41 3/4
1061
48 1/4
1226
NOTE: Illustration provided for dimensions. Fireplace must be adequately framed and supported with 2x4, or larger building materials.
a.Required frame opening width (1/2 of a = horizontal centerline of
fireplace and vent framing opening)
b.Required frame opening depth with 1/2” (13mm) thick wall finish
material (for other wall finish thicknesses, adjust frame opening depth and nailing flanges accordingly)
c.Minimum frame opening height (from base of appliance toheader) d.Minimum height from appliance base to vertical centerline of horizontal
termination vent pipe (with 6” straight vent section and 90° elbow off appliance vent collar)
NOTE: The vertical centerline of the horizontal termination ventpipeisNOTthesameas the vertical centerline of the vent frame opening because of firestop/spacer offset.
e.Minimum height from appliance base front to ceiling f.Mounting platform NOTE: Mountonafullysupportedplatformextendingfullwidthanddepthofunit.
Table11:Fireplace Framing Specifications—Corner Installation with Horizontal Termination
ModelABCDE
B
A
C
D
E
7 (178)
42”
533/4”
(1365mm)
811/4”
(2063mm)
571/2”
(1459mm)
405/8”
(1032mm)
223/16”
(564mm)
54”
653/4”
(1670mm)
985/8”
(2505mm)
705/16”
(1786mm)
493/4”
(1264mm)
281/2”
(724mm)
NOTE: Back wall of chase/enclosure (including finishing materials)shown.
NOTE: Hatched gray area indicates the area that must be clear if a surround is to be installed. NOTE: Assemble top standoffs before installingfireplace.
42” models
40” W x 10 1/2” H
1016mm x 267mm
54” models
51” W x 14 3/4” H
1295mm x 375mm
Table14:Surround Dimensions
42” models
5610/32” W x 2333/64” H
1430mm x 597mm
54” models
6810/32” W x 2729/64” H
1735mm x 697mm
Table15:VentCollar
All models4 1/2” inner x 7 1/2” outer
NOTE: Before installing fireplace, nailing flanges MUST be adjusted according to finish (cleanface or surround) and wall finish material thickness. This is critical to ensure proper fireplace location, especially if installing optional surround.
ModelABCDEF
42”
267/8”
(683mm)
533/4”
(1366mm)
321/2”
(826mm)
153/4”
(400mm)
441/8”
(1121mm)
1511/16” (398mm)
54”
321/2”
(826mm)
653/4”
(1670mm)
363/8”
(924mm)
193/4”
(502mm)
561/8”
(1426mm)
195/8”
(498mm)
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Prepare the Fireplace Top Spacers
2.
1. The two (2) 4 3/8” standoff spacers on top of the fireplace cabinet are shipped flat (Figure 8).
2. Bend the standoffs as shown (Figure 8):
3. Align the holes in the standoff with the holes in the fireplace top, and secure with the supplied screws (Figure 8).
Figure 8: Standoffs
Assembled
standoff
3. Route the Gas Supply Line into the Fireplace
1. Route a 1/2” (13 mm) gas line to the left side of the fireplace (Figure 9).
2. Route the gas line through the gas supply line access opening (Figure 10).
Installation
900079-00, 02/2014
Positioned flat as
shipped from the
factory
NOTE: The gas supply line should not be connected to the appliance until step 11. Connect the Gas Line
(Page 36).
NOTE: ONLY a licensed installer should perform these steps—strictly per NFPA guidelines. Installing a gas supply
line from the fuel supply to the appliance involves numerous considerations, including materials, protection, sizing,
location, controls, pressure, sediment, and more.
NOTE: Gas lines must be routed, assembled, and made of materials that are in strict accordance with local codes and
regulations. Never use galvanized or plastic pipe.
NOTE: See Page 52 for more information on Accessing the Control Compartment.
Figure 9: Routing the gas line through the framingFigure 10: Routing the gas line into the fireplace
Left side front corner of
fireplace framing shown.
Gas line may also enter on
the right side or bottom.
Pipe coupling
(recommended)
13 3/4”
(351 mm)
1 5/8”
(43 mm)
Gas supply
line access
opening
Gas flex line
Gas line shutoff valve
(disconnected from flex line)
Proper Sizing of Gas Line
Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed
per requirements outlined in the National Fuel Gas Code, NFPA 54—latest edition (USA) or CAN/CGA-B149.1—
latest edition (Canada).
NOTE:
s All fireplaces are factory-equipped with a flexible gas line connector and 1/2” shutoff valve (Figure 34).
s See Massachusetts Horizontal Vent Requirements for additional requirements for installations in the state of
Massachusetts in the USA.
s A pipe joint compound rated for gas should be used on the threaded joints. Ensure propane-resistant
compounds are used in propane applications. Be very careful that the pipe compound does not get inside
the pipe.
s A sediment trap in the supply line as close as possible to the fireplace is recommended.
s Check with the local building official for local code requirements (e.g., Are below grade penetrations of the gas
line allowed?, etc).
18
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Installation
CAUTION
If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this is the only gas
appliance in the dwelling—see NPFA 58), there may be a loss of pressure. This can result in insufficient
fuel delivery that can cause sooting, delayed ignition, or other malfunctions. Any damage resulting from an
improper installation is not covered by the limited warranty.
4. Rough in the Electrical Supply, if Needed
1. As necessary, rough in the fireplace electrical supply per NEC and local codes.
5. Prepare the Fireplace Nailing Flanges
Nailing flange positions are provided for the following wall finish thicknesses:
s 1/2”
s 3/4”
s 1 1/4”
s 1 1/2”
s 1”
Preparing the nailing flanges for a cleanface finish installation
1. If the wall finish material is thicker than 1/2”, move the nailing flanges to the correct horizontal position.
NOTE: The nailing flanges are set at the factory in the correct vertical position for a cleanface installation (Figure 11).
Figure 11: Vertical nailing flange settings for cleanface finishFigure 12: Vertical nailing flange settings for surround finish
Preparing the nailing flanges for a surround finish installation
1. Move the nailing flanges to the correct vertical positions (Figure 12).
2. Adjust the nailing flanges to the correct horizontal position.
6. Place the Fireplace in the Framing and Secure
1. Secure the fireplace to the side framing members using the unit’s nailing flanges —one top and bottom on each
side of the fireplace front (Figure 13). Use 8d nails or the equivalent.
NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are
EXEMPT from the 1/2” clearance to combustible requirements for the firebox outer wrapper. Combustible framing
may be in direct contact with the nailing flanges and may be located within 1/2” of screw heads and the firebox
wrapper in areas adjacent to the nailing flanges.
Figure 13: Nailing flange attachment
Unit nailing flange
Side
framing
(no clearance to combustible
framing is required)
19
Innovative Hearth Products
Base
3
5
10
45
6
40
15 ft Maximum
horizontal run
60 ft Maximum vertical run
60
2
15
Horizontal Distance (ft)
Vertical Height (ft)
Vertical Height (ft)
4
6
1
4.56
7.5
Position 2Position 1
6 ft Minimum
vertical run
6 ft Minimum
10
9
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
VENT SYSTEM PREPARATION
7. Select a Horizontal or Vertical Vent System
1. With the fireplace secured in the framing, determine the vent route and identify the exterior termination location.
The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Use only approved
vent components (Page 8 and Page 45).
NOTE: This fireplace must be vented directly to the outside.
The vent system may not service multiple appliances, and must never be connected to a
flue serving a separate solid fuel burning appliance.
NOTE: The vent pipe is tested to be run inside an enclosed wall (such as a chase). There is no requirement for
inspection openings in the enclosing wall at any of the joints in the vent pipe.
8. Install the Vent Restrictor (if necessary)
1. Use the vent run descriptions in Figure 14 to determine if a vent restrictor is necessary.
2. If necessary, assemble the vent restrictor and wings as detailed in Figure 14 and Figure 16.
3. If necessary, install the appropriate vent restrictor with the flaps facing up (Figure 15). The vent restrictor is held in
place by friction. The vent restrictor must not be visible inside the firebox.
Installation
900079-00, 02/2014
WARNING
NOTE: If the baffle and back panel are installed, remove them before installing the vent restrictor.
NOTE: The vent restrictor is shipped in the firebox.
Figure 14: When to use a vent restrictorFigure 15: Vent restrictor installation, Top vent
U-Shaped
Vent
Restrictor
Inner
Fireplace
Collar
Appliance Top Vent Outlet
Vent
Collar
Vent
Restrictor
(held in
place by
friction)
Figure 16: Vent restrictor assembly
Base Vent Restrictor
*
20
* For straight runs or runs with elbows as illustrated in Vertical Vent Figures/Tables starting on Page 26.
Vent Restrictor Position 1
*
Vent Restrictor Position 2
Innovative Hearth Products
SV4.5E90
(90
°
Elbow)
8 1/8 in.
(206 mm)
Swivel Joint
(360
°
swivel)
4 13/16 in.
(122 mm)
SV4.5E45
(45
°
Elbow)
Swivel Joint
(360
°
swivel)
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Vent Restrictor with Vertical Terminations
When vertically terminating the vent system through the roof and using the vent restrictor, install the vent restrictor
in the top vent of the fireplace outlet.
If installing more than 6 ft of vertical venting, install the restrictor (Figure 15), from inside or outside the unit, in the
inner fireplace collar. The vent restrictor is held in place by friction.
Vent Restrictor with Horizontal Terminations
When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required.
If installing more than 4 ft of vertical venting, install the restrictor (Figure 15), from inside or outside the unit, in the
inner fireplace collar. The vent restrictor is held in place by friction.
Secure Vent® SV4.5 direct-vent system components are unitized concentric pipe components featuring positive twist lock connections
(Figure 17 and Figure 18). All of the fireplaces covered in this document are fitted with collars having locking inclined channels. The
dimpled end of the vent components fit over the fireplace/vent collar to create the positive twist lock connection.
1. Align the dimpled end over the collar, adjusting the radial alignment until the four (4) locking dimples are aligned
with the inlet of the four (4) inclined channels on the collar (Figure 17).
2. Push the vent component against the collar until it fully engages, then twist the component clockwise, running
the dimples down and along the incline channels until they seat at the end of the channels.
Installation
900079-00, 02/2014
Vent elbows
NOTE: The unitized design of the Secure Vent® components will engage and seal both the inner and outer vent pipe.
3. If desired, a #6 x 1/2” screw can be used at the joint, but is not required as the pipe will securely lock
when twisted (Figure 18).
Where required, a telescopic vent section (SV4.5LA) may be used to provide the installer with an option to install
in tight and confined spaces, or where the vent run made up of fixed length pieces develops a joint in a undesirable
location, or will not build up to the required length. The telescopic vent section has an effective length of from
1 1/2–7 1/2” (38–191 mm). The telescopic vent section is fitted with a locking inclined channel end (identical to a
normal vent section component) and a plain end with three (3) pilot holes. Slip the plain end over the locking channel
end of a standard SV4.5 vent component the required distance and secure with three (3) screws.
Figure 17: Connecting vent
components
Arrow
Dimple
Locking
Incline
Channel
Appliance Collar or
Vent Section
Figure 18: Connected vent
components
Dimple
Locking
Incline
Channel
Arrow
Figure 19: Elbow Dimensions
4 13/16”
(122 mm)
Swivel Joint
(360°)
SV4.5E45
(45° elbow)
Swivel Joint
(360°)
SV4.5E90
(90° elbow)
8 1/8”
(206 mm)
Vent elbows are available in 90° and 45° configurations. Refer to Figure 19 for the SV4.5E45 and SV4.5E90
elbow dimensions. The elbows feature a twist section to allow them to be routed about the center axis of their initial
collar section to align with the required direction of the next vent run element. Two (2) 45° elbows may be used in
place of one 90° elbow. When planning vent runs, make allowances for elbows.
NOTE: A 90° elbow may NOT be attached directly to the appliance collar. A minimum of 6” of vent pipe must be used between the
fireplace collar and a 90° elbow. An elbow is accepatble as 1 ft of vertical rise.
1. Rotate the elbow in a clockwise direction (to avoid the possiblity of unlocking any of the previously connected
vent sections) for proper alignment (Figure 19). See Connecting the vent pipe for more information.
21
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Vent section length table
Table 17 will assist calculating how many vent sections are needed for the planned vent configuration. When a vent
section is engaged with another section, its effective length will be 1 1/2” shorter.
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Clearance to combustibles
Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.).
For all vertical runs:
s 1” (25 mm) from all sides
NOTE: Attic insulation shield (96K94) must be installed when blown or loose-fill insulation is used, and is
recommended for all attic installations.
For all horizontal/inclined runs:
s 3” (76 mm) from the top
s 1” (25 mm) from the sides
s 1” (25 mm) from the bottom
9. Install the Vent System
Install the Vertical Termination Vent System
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting
according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the
current standards of CAN/CGA-B149.1 in Canada.
Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier.
Dégagement conforme aux codes d’installa tion locaux et aux exigences du foumisseunde gaz.
Vertical vent systems terminate through the roof. The minimum vent height above the roof and/or adjacent walls
is specified in ANSI Z223.1 (In Canada, the current CAN/CGA-B149.1 installation code) by major building codes.
Always consult your local codes for specific requirements. A general guide to follow is the gas vent rule (Table 6).
The following figures and their associated vertical vent tables illustrate the various configurations that are possible
for use with these fireplaces. Secure Vent® pipe is shown in these figures; Secure Flex® pipe may also be used.
A table summarizes each configuration’s minimum and maximum vertical and horizontal length parameters for a
variety of applications.
1. Refer to Figure 25, Table 19, and Table 20 on Page 26–27 to select the type of vertical installation desired.
Elbows are available in 90° and 45° configurations. Refer to Figure 19 on Page 21 for the SV4.5E45 and
SV4.5E90 elbow dimensional specifications.
Installation
900079-00, 02/2014
Vertical (Straight) Installation
1. Determine the number of straight vent sections required—See Effective Vent Length on Page 21 for more
information. Plan the vent lengths so that a joint does not occur at the intersection of ceiling or roof joists.
Figure 20: Vertical (Straight) Installation
Max. 60 ft
(18 m)
Min. 6 ft
(1.8 m)
Vertical termination
Flashing and
storm collar
See Table 8
Vertical
firestop/spacer
SecureVent®
vent sections
23
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Vertical (Offset) Installation
1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent
Length on Page 21 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists. Allow for elbows (Figure 19). Maintain the minimum clearances for combustibles (Page 23).
2. Frame the ceiling opening—Use a plumb line from the ceiling above the fireplace to locate the center of the vertical
run. Cut and/or frame an opening, 10 1/2 x 10 1/2” (267 x 267 mm) inside dimensions, about this center mark
(Figure 21). Vertical firestop/spacer must be used anywhere vent pipe passes through a combustible floor or ceiling.
Figure 21: Framing the ceiling opening
Roof
Framing
10 1/2” (267 mm)
minimum 10 1/2 in.
(267 mm)
10 1/2” (267 mm) minimum
minimum 10 1/2 in.
(267 mm)
minimum
Installation
900079-00, 02/2014
Ceiling
Framing
Plumb Bob
3. Attach the vent components to the fireplace—See Connecting the vent pipe on Page 21.
4. Attach the vent components to each other—See Connecting the vent pipe on Page 21.
5. Install firestop/spacer at ceiling—When using Secure Vent®, use SV4.5VF firestop/spacer at ceiling joists; when
using Secure Flex®, use SF4.5VF firestop/spacer. If there is living space above the ceiling level, the firestop/
spacer must be installed on the bottom side of the ceiling. If attic space is above the ceiling, the firestop/spacer
must be installed on the top side of the joist. Route the vent sections through the framed opening and secure the
firestop/spacer with 8d nails or other appropriate fasteners at each corner.
Remember to maintain 1” (25 mm) clearance to combustibles, framing members, and attic or ceiling insulation
when running vertical chimney sections. The gap between the vent pipe and a vertical firestop can be sealed with
non-combustible caulking.
NOTE: Attic insulation shield (96K94) must be installed when blown or loose-fill insulation is used, and is
recommended for all attic installations.
6. Support the vertical vent run sections—Support the vertical portion of the venting system every 8 ft (2.4 m)
above the fireplace vent outlet. One method of support is by utilizing field provided support straps (conventional
plumber’s tape). Secure the plumber’s tape to the framing members with nails or screws. Loop the tape around
the vent, securing the ends of the tape to the framing. If desired, sheet metal screws #6 x 1/2” length may be
used to secure the support straps to the vent pipe (Figure 22).
NOTE: Proper venting support is very important. Never use the fireplace to support the weight of the venting.
Figure 22: Supporting the Vertical Vent Run
7. Change vent direction of horizontal/inclined run—Install the SV4.5E45 and SV4.5E90 elbows in the same
24
manner as the straight vent sections. See Vent elbows on Page 21 for more information.
Blocking
Support straps
(plumber’s tape,
not provided)
8 ft (2.4 m)
maximum
1/2” (12.7 mm)
minimum
clearance to
combustibles
Innovative Hearth Products
C
D
Storm
Collar
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
8. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent
sections in horizontal/inclined run. Install support straps every 5 ft (1.52 m) along horizontal/inclined vent runs
using conventional plumber’s tape.
Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in
a straight (no dips), slightly elevated plane of approximately 1/4” per 1 ft (20 mm per 1 m).
Maintain the required clearances to combustibles (Page 23).
9. Frame the roof opening—Identify the location for the vent at the roof. Cut and/or frame opening (Table 18).
Tabl e 18: Roof Framing Dimensions
10. Install the roof flashing—Extend the vent sections through the roof structure. Install the roof flashing over the
vent section and position such that the vent column rises vertically (use carpenters level). Nail along perimeter
to secure flashing or adjust roofing to overlap the flashing edges at top and sides only and trim where necessary.
Seal the top and both sides of the flashing with waterproof caulking.
11. Install the storm collar—Install the storm collar, supplied with the flashing, over the vent/flashing joint
(Figure 23). Loosen the storm collar screw. Slide collar down until it meets the top of the flashing. Tighten the
adjusting screw. Apply non-combustible caulking or mastic around the circumference of the joint to provide a
water tight seal.
Figure 23: Installing the Storm CollarFigure 24: Installing the Vertical Termination
12. Install the vertical termination—Extend the vent sections to the correct height (Figure 4). The SV4.5CGV-1
Vertical Termination (Figure 24) installs in the exact same fashion as any other Secure Vent® section.
If the vent system extends more than 5 ft (1.5 m) above the roof flashing, stabilizers are required. Additional
screws may be used at section joints for added stability. Guide wires or roof support assemblies may be attached
to the joint for additional support on multiple joint configurations.
25
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Vertical Vent Figures/Tables
NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined
run in a straight (no dips), slightly elevated plane of approximately 1/4” per 1 ft (20 mm per 1 m).
NOTE: SV4.5VF (Secure Vent), SF4.5VF (Secure Flex) firestop/spacer must be used anytime vent pipe passes
through a combustible floor or ceiling. SV4.5HF (Secure Vent), SF4.5HF (Secure Flex)firestop/spacer must be used
anytime vent pipe passes through a combustible wall.
NOTE: Two (2) 45° elbows may be used in place of one (1) 90° elbow. The same rise to run ratios, as shown in the
venting figures for 90° elbows, must be followed if 45° elbows are used.
NOTE: An elbow is acceptable as 1 ft of vertical rise, except where an elbow is the only vertical component in
the system.
Do NOT join separate sections of concentric flexible vent pipe.
Total H = Max. 20 ft (6.096 m)
Total H + Total V = Max. 60 ft (18.3 m)
Install the U-shaped vent restrictor in any vent run with more than 6 ft of vertical rise. See Page 20 for more information.
Secure Vent
Vent Sections
A 20-ft total Horizontal vent run requires min. 13.5 ft total vertical venting.
Vertical firestop/spacer must be used anywhere vent pipe passes through a combustible floor or ceiling.
Horizontal firestop/spacer must be used anywhere vent pipe passes through a combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance collar. A minimum of 6” pipe must be used between the
fireplace collar and a 90° elbow.
26
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Tabl e 19: Top V en t— Two 90° El bo wsTabl e 20: Top V en t— Th ree E lb ow s
H
Vertical Firestop/
Spacer
Vertical Firestop/
Spacer
V
1
900079-00, 02/2014
Horizontal Firestop/
Spacer
Installation
Horizontal
Firestop/
Spacer
V
1
H
1
V
H
Maximum total HMinimum total VMaximum total HMinimum total V
feetmetersfeetmetersfeetmetersfeetmeters
51.5243.31.00651.5243.31.006
103.16.51.981103.16.51.981
154.65103.048154.65103.048
206.09613.54.115206.09613.54.115
Total H = Max. 20 ft (6.096 m)
Total H + Total V = Max. 60 ft (18.3 m)
Install the U-shaped vent restrictor in any vent run with more than 6 ft of vertical
rise. See Page 20 for more information.
A 20-ft total Horizontal vent run requires min. 13.5 ft total
vertical venting.
Vertical firestop/spacer must be used anywhere vent pipe
passes through a combustible floor or ceiling. Horizontal firestop/
spacer must be used anywhere vent pipe passes through a
combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance
collar. A minimum of 6” pipe must be used between the fireplace
collar and a 90° elbow.
Total H = Max. 20 ft (6.096 m)
Total H + Total V = Max. 60 ft (18.3 m)
Install the U-shaped vent restrictor in any vent run with more than 6 ft of
vertical rise. See Page 20 for more information.
A 20-ft total Horizontal vent run requires min. 13.5 ft total
vertical venting.
Vertical firestop/spacer must be used anywhere vent
pipe passes through a combustible floor or ceiling. Horizontal
firestop/spacer must be used anywhere vent pipe passes through
a combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance
collar. A minimum of 6” pipe must be used between the fireplace
collar and a 90° elbow.
V
27
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Install the Horizontal Termination Vent System
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting
according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the
current standards of CAN/CGA-B149.1 in Canada.
Ensure clearances are in accordance with local installation codes and the requirements of the gas supplier.
Dégagement conforme aux codes d’installa tion locaux et aux exigences du foumisseunde gaz.
Horizontal vent systems terminate through an outside wall. Building Codes limit or prohibit terminating in
specific areas (Table 7).
The following figures and their associated horizontal vent tables illustrate the various configurations that are possible
for use with these fireplaces. Secure Vent
A table summarizes each configuration’s minimum and maximum vertical and horizontal length parameters for a
variety of applications. For more information on connecting the vent pipe, see Page 21.
Figure 26: Typical Horizontal Vent Installation
Building
support
framing
Horizontal
support
brackets
900079-00, 02/2014
®
pipe is shown in these figures; Secure Flex® pipe may also be used.
Horizontal
Horizontal/inclined run
firestop /
spacer
Installation
90° Elbow
Vertical
rise
Ceiling
Vertical
firestop /
spacer
Support vertical venting every
8 ft (2.4 m) above fireplace
vent outlet.
Place horizontal support brackets
every 5 ft (1.524 m).
Fireplace
Straight vent
sections
Horizontal
termination
Exterior
wall
Horizontal
termination
1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent
Length on Page 21 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists. Allow for elbows (Figure 19). Maintain the minimum clearances for combustibles (Page 23).
2. Frame the exterior wall opening—Locate the center of the vent outlet on the exterior wall (Table 10). Cut and/
or frame an opening, 10 1/2 x 12 1/8” (267 x 308 mm) inside dimensions, about this center. Horizontal firestop/
spacer must be used anywhere vent pipe passes through a combustible wall.
3. Frame the ceiling opening—If the vertical route is to penetrate a ceiling, use plumb line to locate the center
above the fireplace. Cut and/or frame an opening, 10 1/2 x 10 1/2” (267 x 267 mm) inside dimensions, about
this center (Figure 21).
4. Attach the vent components to the fireplace—See Connecting the vent pipe on Page 21.
5. Attach the vent components to each other—See Connecting the vent pipe on Page 21.
6. Install the firestop/spacer at the ceiling—When using Secure Vent®, use SV4.5VF firestop/spacer at ceiling
joists; when using Secure Flex®, use SF4.5VF firestop/spacer. If there is living space above the ceiling level,
the firestop/ spacer must be installed on the bottom side of the ceiling. If attic space is above the ceiling, the
firestop/spacer must be installed on the top side of the joist. Route the vent sections through the framed opening
and secure the firestop/spacer with 8d nails or other appropriate fasteners at each corner.
Maintain 1” (25 mm) clearance to combustibles, framing members, and attic or ceiling insulation when running
vertical chimney sections.
NOTE: Attic insulation shield (96K94) must be installed when blown or loose-fill insulation is used, and is
recommended for all attic installations.
7. Support the vertical run sections—On the vertical run, support the venting system every 8 ft (2.4 m) above the
fireplace vent outlet with field provided support straps (Plumber’s tape). Attach the straps to the vent pipe and
secure to the framing members with nails or screws (Figure 26).
28
NOTE: Proper venting support is very important. Never use the fireplace to support the weight of the venting.
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows
in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed
about the center axis of their initial collar section to align with the required direction of the next vent run element.
Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking any of the previously
connected vent sections (Figure 19).
9. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent
sections in horizontal/inclined run. Install support straps every 5 ft. (1.52 m) along horizontal/inclined vent runs
using conventional plumber’s tape or catalog number SV4.5SU (Figure 26). Maintain the horizontal/inclined run
in a straight (no dips), slightly elevated plane. The recommended incline is approximately 1/4” per 1 ft (20 mm
per 1 m) horizontal, in a direction away from the fireplace. Smaller rise per foot run ratios are acceptable all the
way to at or near level. Use a carpenter’s level to measure from a constant surface and adjust the support straps
as necessary.
Maintain the required clearances to combustibles (Page 23).
10. Assemble the vent run to the exterior wall—If not previously measured, locate the center of the vent at the
exterior wall. Prepare the opening. Assemble the vent system until the terminus of the last section is within
5” (127 mm) to 8 1/2” (216 mm) inboard of the exterior surface to which the termination is to be attached
(Figure 27). If the terminus of the last section is not within this distance, use the telescopic vent section
SV4.5LA, as the last vent section. Table 21 lists the additional venting components needed (in addition to the
termination and adaptor) for a range of wall thicknesses.
11. Attach the termination adaptor—Attach the adaptor (SV4.5RCH, provided with the termination) to the vent
section or telescoping vent section, elbow or fireplace collar (Figure 27).
NOTE: If blown insulation is to be used, the through-wall shield kit (H5816) MUST be installed.
12. Install the firestop/spacer at the exterior wall—Install SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) firestop/
spacer over the opening at the exterior side of the framing, long side up, with the 3” spacer clearance at the top
(Figure 27) and nail into place.
Installation
900079-00, 02/2014
NOTE: The firestop/spacer may also be installed over the opening at the interior side of the framing.
13. Install the termination (SV4.5HT-2 and SV4.5HTSS (42” models only))—From outside the exterior wall,
slide the collars of the termination onto the adaptor (the outer over the outer and the inner inside the inner)
until the termination seats against the exterior wall surface to which it will be attached. Orient the housing of
the termination with the arrow pointed upwards. Secure the termination to the exterior wall. The horizontal
termination must not be recessed into the exterior wall or siding by more than the 1 1/4” (32 mm) (Figure 28).
NOTE: If the venting exits the building below grade, or close to grade, see Installation Accessories on
Page 45 for available snorkel terminations. The termination must be above grade and above the expected
level of snow accumulation.
NOTE: The vent termination is hot while in operation and for a period of time following the use of the fireplace.
To prevent contact with hot surfaces, use a horizontal termination guard; available for purchase at your
local dealer.
The horizontal terminations have been designed to perform in a wide range of weather conditions. They meet or
exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the termination where water from eaves and adjoining rooflines may create a heavy flow of cascading water onto the termination cap. If the cap
must be placed where the possibility of cascading water exists, it is the responsibility of the builder to direct the
water away from the termination cap by using gutters or other means.
Carefully follow the installation instructions for the termination, including the use of silicone caulking
where required.
29
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Figure 27: Installing the Horizontal Termination
Installation
900079-00, 02/2014
5-1/8"
(130 mm)
(178)
12-1/8"
(308 mm)
Adaptor
SV4.5RCH
6 to 48 inch Vent Section,
Telescopic vent section,
Elbow or Appliance Collar
Firestop/Spacer (SV4.5HF) shown
on the exterior side of the wall. It
may also be installed on the
interior side.
7"
10-1/2"
(267 mm)
Note: Centerline of Vent Piping is
NOT the Same as the Centerline of
the Frame Opening.
Base of Appliance
See Table 10 for the minimum distance to the
(25.4 mm)
base of the fireplace.
Typical
Termination
Shown
(76 mm)
1"
3"
NOTE: To help minimize water infiltration install the firestop/spacer (SV4.5HF) on the exterior side of the wall.
Figure 28: Venting Connection and Exterior Wall Recessing of the Horizontal Termination
** For thicknesses greater than 10”
(254 mm) see Table 21.
Interior Surface of
Finished Wall
Maximum Extent of
Siding
Caulk*
Vent Run Section
Relative to Exterior
Surface of Framing
Last Vent Section
(Use Telescopic
Vent Section,
if necessary.)
Caulk*
Typical Horizontal
Termination
Termination
Adaptor
Stucco
*Use silicone caulk to seal the top and sides of the termination,
up to the underlayment, stucco, or masonry wall surface.
Max. 9-1/4" (235 mm)
Wall Thickness**
Exterior Surface of Siding
Exterior Surface
of Framing
6" to 9-1/4"
(152 to 235 mm)**
Typical Horizontal
Termination
Max. 1-1/4" Recess of
Horizontal Termination into
Exterior Finishing Material
30
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Tabl e 21: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits
Vent Components RequiredExterior Wall Thickness
Termination Kit and 6” Vent Section (SV4.5L6)10 3/4–14” (273–356 mm)
Termination Kit and 12” Vent Section (SV4.5L12)16 3/4–20” (426–508 mm)
Termination Kit and Telescopic Section (SV4.5L12)11 3/4–20” (299–508 mm)
NOTE: See Figure 28 for wall thickness ranges when using SV4.5HT-2 termination kit.
Horizontal Vent Figures/Tables
NOTE: Secure Vent® rigid vent pipe and terminal are shown in the figures. Secure Flex® flexible vent pipe and
terminal may also be used.
NOTE: Two (2) 45° elbows may be used in place of one (1) 90° elbow. The same rise to run ratios, as shown in the
venting figures for 90° elbows, must be followed if 45° elbows are used.
NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined
run in a straight (no dips), slightly elevated plane of approximately 1/4” per 1 ft (20 mm per 1 m).
NOTE: SV4.5VF (Secure Vent), SF4.5VF (Secure Flex) firestop/spacer must be used any time vent pipe passes
through a combustible floor or ceiling. SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) firestop/spacer must be used
any time vent pipe passes through a combustible wall.
Installation
900079-00, 02/2014
Termination Kit Only6–9 1/4” (152–235 mm)
WARNING
Do not join separate sections of concentric flexible vent together.
Tabl e 22: Top V en t— On e 90° E lb ow
Maximum total HMinimum total V
feetmetersfeetmeters
20.61010.305
4.51.37230.914
61.82941.220
7.52.28651.524
92.74361.729
154.572103.048
Total H = 15 ft (4.572 m) maximum
Total H + Total V = 60 ft (18.3 m) maximum
Install the U-shaped vent restrictor in any vent run with more than 6 ft of
vertical rise. See Page 20 for more information.
Small square termination (SV4.5HTSS) shown.
See Tab l e 21 as an aid in venting component selection for a particular range of exterior
wall thicknesses.
15 ft total horizontal vent run requires a minimum of 10 ft total vertical vent.
Vertical firestop/spacer must be used anywhere vent pipe passes through a combustible floor or ceiling. Horizontal firestop/
Horizontal
Termination
Horizontal Firestop/
Spacer
H
Vertical Firestop/
Spacer
spacer must be used anywhere vent pipe passes through a combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance collar. A minimum of 6” pipe must be used between the fireplace
collar and a 90° elbow.
V
31
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Installation
Tabl e 23: Top V en t— Two 90° El bo ws
Maximum total HMinimum total V
feetmetersfeetmeters
20.61010.305
4.51.37230.914
61.82941.220
7.52.28651.524
92.74361.729
154.572103.048
Total H = 15 ft (4.572 m) maximum
Total H + Total V = 60 ft (18.3 m) maximum
Install the U-shaped vent restrictor in any vent run with more
than 6 ft of vertical rise. See Page 20 for more information.
Small square termination (SV4.5HTSS) shown.
See Tab l e 21 as an aid in venting component selection for a particular range of exterior wall thicknesses.
15 ft total horizontal vent run requires a minimum of 10 ft total vertical vent.
Vertical firestop/spacer must be used anywhere vent pipe passes through a combustible floor or ceiling. Horizontal firestop/spacer
Horizontal
Termination
Horizontal Firestop/
Spacer
H
H
1
Vertical Firestop/
Spacer
must be used anywhere vent pipe passes through a combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance collar. A minimum of 6” pipe must be used between the fireplace collar
and a 90° elbow.
V
Tabl e 24: Top V en t— Th ree 9 0° E lb ow s
Maximum total HMinimum total V
feetmetersfeetmeters
20.61010.305
4.51.37230.914
61.82941.220
7.52.28651.524
92.74361.729
154.572103.048
Total H = 15 ft (4.572 m) maximum
Total H + Total V = 60 ft (18.3 m) maximum
Install the U-shaped vent restrictor in any vent run with more
than 6 ft of vertical rise. See Page 20 for more information.
Small square termination (SV4.5HTSS) shown.
See Tab l e 21 as an aid in venting component selection for a particular
range of exterior wall thicknesses.
15 ft total horizontal vent run requires a minimum of 10 ft total vertical
vent.
Vertical firestop/spacer must be used anywhere vent pipe passes through a combustible floor or ceiling. Horizontal firestop/spacer
Horizontal
Termination
Horizontal Firestop/
Spacer
H
1
Vertical Firestop/Spacer
H
V
1
V
must be used anywhere vent pipe passes through a combustible wall.
Install the provided vent restrictor, if required.
A 90° elbow may NOT be attached directly to the appliance collar. A minimum of 6” pipe must be used between the fireplace collar
and a 90° elbow.
32
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Vertical or Horizontal Venting Using Secure Flex Kits and Components
Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent® (SV4.5)
direct-vent components can be used. All restrictions, clearances and allowances pertaining to rigid vent also apply to
flexible vent. Do NOT modify Secure Flex kits . Also, do NOT join separate sections of flex vent together. Secure Flex
kits can be installed on the end of a Secure Vent (SV4.5) rigid vent run, provided that doing so does not violate any
of the venting length, height, routing, horizontal to vertical ratio requirements, or clearance considerations detailed in
this manual.
Secure Flex kits come with an included adaptor that can be installed on the fireplace collar or the inclined channel
end of the last Secure Vent (SV4.5) vent section in a rigid system in the exact same fashion as any other Secure Vent
section. Align the dimpled end of the adaptor over the previously installed section or fireplace collar, adjusting the
radial alignment until the four locking dimples of the adaptor are aligned with the inlets of the four incline channels of
the last vent section or collar. Push on the adaptor until it is fully engaged, then twist the adaptor clockwise running
the dimples down and along the incline channels until they seat at the end of the channels.
Securing screws in
three (3) places just
below the gear clamp
1. Install the Inner Flex Pipe.
a. Install the small gear clamp loosely around the inner flexible vent, then push it back out of the way.
b. Apply a bead of Mill-Pac Black (700 °F) high temperature sealant (P/N 10K81) to the inner adaptor collar,
approximately 1/2” from the end.
c. Pull and extend the inner flexible vent.
d. Slide the inner flex vent over the adaptor collar at least 1 3/4”.
NOTE: Ensure the flex vent is free from damage or tears.
e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor inner collar
approximately 3/4” from the end of the flex.
f. Install three (3) screws 120° apart through the flexible vent and into the adaptor collar just below the gear
clamp to provide additional security to the connection.
2. Install the outer Flex Pipe.
a. Install the large gear clamp loosely around the outer flexible vent pipe, then push it back out of the way.
b. Apply a bead of Mill-Pac Black (700 °F) high temperature sealant (P/N 10K81) to the outer adaptor collar.
Cover to the grooves of the collar that extend approximately 1” from the end and to the flat surface,
approximately 1 3/8” from the end.
c. Pull and extend the outer flexible vent.
d. Slide the outer flexible vent over the adaptor collar. Ensure the flexible vent completely engages the adaptor collar
1 3/4” from the end, and that it is free from damage or tears.
e. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adaptor outer collar
approximately 3/4” from the end of the flexible vent.
33
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
f. Install three (3) screws 120° apart through the flexible vent and into the adaptor collar just below the gear
clamp to provide additional security to the connection.
3. Route the flexible vent.
NOTE: Ensure that the flexible vent is properly routed to provide the required clearance. Do NOT allow the flexible vent
to bend in a radius tighter than 5” (127 mm) (Figure 30). Place the internal flexible vent spacers evenly and avoid
kinking the inner vent. Support horizontal sections of flexible vent with metal straps at 2 ft (0.61 m) intervals.
4. Install firestop/spacers at ceiling and wall penetrations.
s SF4.5 VF firestop/spacer for ceilings
s SF4.5 HF firestop/spacer for walls
NOTE: See the appropriate sections and figures shown throughout the venting section for installation
requirements.
5. Attach the flexible vent to the termination.
NOTE: Secure Flex
vent cut to size at the job site. Attach the flexible vent to the Secure Flex terminations as it was attached to the
adaptor (Figure 29).
NOTE: Attach Secure Flex vent to Secure Flex terminations only. Do NOT substitute Secure Vent
or Secure Vent adaptor for Secure Flex components. Secure Flex termination and adaptor collars are a
different circumference than Secure Vent collars. Secure Flex vent has a longer center tube to improve
ease-of-installation.
10. Complete the Field Wiring
Installation
900079-00, 02/2014
®
components can be purchased separately and attached to bulk lengths of Secure Flex flexible
®
terminations
Technical data
CAUTION
The ground supply lead must be connected to the wire attached to the green ground screw
located on the outlet box (see wiring diagrams). Failure to do so will result in a potential
safety hazard. The appliance must be electrically grounded in accordance with local codes
or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70—latest
edition (in Canada, the current CSA C22-1 Canadian Electrical Code).
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
ATTENTION
Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher.
Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
The gas valve is set in place and pre-wired at the factory.
Supply Voltage, Remote Control Transmitter:
s 4.5 V (three (3) AAA batteries)
Supply Voltage, Wall Switch Receiver:
s 6.0 V (four (4) AA batteries)
Ambient temperature rating:
s 32–140 °F (0–60 °C)
Radio frequency:
s 315 MHz
Wire the fireplace
NOTE: Connection to the main power supply is only required if optional blower is installed.
34
1. Route a 3-wire, 120 Vac, 60 Hz, 1 ph power supply to the fireplace junction box.
Innovative Hearth Products
P/N 580491-01
ELECTRONICWIRINGDIAGRAMFORGRAVITYVENTFIREPLACES
JUNCTION BOX
120V AC
REMOTE RECEIVER
ON/OFF SWITCH
WALL SWITCH
LIMIT SWITCH
B-VENT MODELS
ONLY
AC/DC
POWER
ADAPTOR
HOT
NEUTRAL
OPTIONAL
GROUND
BATTERY HOLDER
DFC WIRE HARNESS
SPARK WIRE CABLE
PILOT GROUND WIRE
PILOT
SENSOR
CABLE
HOOD
IGNITER ROD
FLAME SENSOR
PILOT TUBE
OPTIONAL CPI SWITCH
OFF (O) = INTERMITTENT PILOT MODE
ON (-) = STANDING PILOT MODE
PROFLAME DFC BOARD
PROFLAME VALVE
ELECTRONIC PILOT ASSEMBLY
B = BLACK
BR = BROWN
GY = GRAY
PU = PURPLE
R = RED
BL = BLUE
G = GREEN
O = ORANGE
W = WHITE
Y = YELLOW
WIRING COLOR CODE
B
B
B
R
R
W
W
B
B
B
B
BL
BL
G
G
O
Y
Y
R
R
Y
W
G
G
O
SCHEMATIC REPRESENTATION ONLY
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
NOTE: The junction box can be moved to the bottom of the box (Figure 33). To move the junction box remove
the cover plate, compress junction box to release it from the fireplace. Select the new location. For the bottom
location, install the 3-wire 120 Vac supply wire and strain relief in the hole provided. Connect the wires
(Figure 31). Reinstall the junction box by compressing the sides, then place the small flange of the Junction
box in the small slot. Place the larger flange into the larger slot and release. Reinstall the cover over the original
junction box location.
2. Remove the electrical inlet cover plate from the side of the unit by removing the plate securing screws.
3. Remove the cover plate knockout, then feed the power supply wire through the knockout opening and into the
unit junction box.
4. Connect the black power supply wire to the power outlet red pigtail lead (Figure 31 and Figure 32). Connect the
white power supply wire to the outlet common terminal.
White
Ground—green
Neutral—white
120 VAC—black
Black
(power supply unswitched)
Junction box
Red
Tab intact
Hot side of
receptacle
Field wired
Factory wired
5. Connect the ground supply wire to the pigtail lead attached to the outlet’s green ground screw. Restrain the inlet
Fireplace
Right Side
Junction box locations
Fireplace Back
Fireplace Bottom
power lead per NEC or local codes.
6. After the wiring is complete, replace the cover plate.
35
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
Install the wiring for the wall switch receiver
Place the wall switch receiver in the OFF position during installation or maintenance. The remote control transmitter
and wall switch receiver work via radio frequency. If the wall switch receiver is mounted in a metal case, severe
loss of performance (reduction in operational range) may result. Turn OFF main gas supply to the fireplace during
installation, maintenance, removal, or replacement of the wall switch receiver.
1. Install a junction box (not provided) on the wall adjacent to the appliance, within reach of the remote system
umbilical cord wiring harness.
2. Position the 2-wire harness in the junction box (not included).
Fire hazard. Can cause severe injury or death. The wall switch receiver causes ignition of the
appliance. The appliance can turn on suddenly. Keep away from the appliance burner when
operating the remote system or activating manual bypass of the remote control system.
Installation
900079-00, 02/2014
WARNING
WARNING
Property damage hazard. Excessive heat can cause property damage. The appliance can
stay lit for many hours. Turn OFF the appliance if it is not going to be attended for any length
of time. Always place the remote control transmitter where children cannot reach it.
Install batteries for battery backup
Batteries are only required to operate the unit in the event of loss of 120 VAC line power.
1. Remove the surround, if installed (Figure 44).
2. Remove the glass door for easier access (Page 56).
3. The battery holder is attached via cable to the CPI/IPI bracket on the left hand side (Figure 2). Pull the cable until
the battery holder is visible. Turn the battery holder such that it will clear the unit and can be removed from the
unit (the black and red wires will still be connected to the unit).
4. Place the four (4) provided AA batteries into the holder. Align the (–) end of the batteries the the spring end of
the holder.
5. Replace the battery holder and other removed components (if applicable) in reverse order.
11. Connect the Gas Line
The gas control valve is located in the lower control compartment (Figure 53).
All codes require a shutoff valve mounted in the supply line. Figure 34 illustrates the method for connecting the gas
supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary depending on locality.
Installation must be in compliance with local codes. The provided gas-line shutoff valve (located in the control
compartment) is intended as a service shutoff. National and local codes may require installation of a second gas-line
shutoff valve (not provided) in a readily accessible location. Consult local codes.
These fireplaces are equipped with a gas flex line for use (where permitted) in connecting the unit to the gas line. A
gas flex line is provided to aid in attaching the direct-vent fireplace to the gas supply. The gas flex line can only be
used where local codes permit. The flex line is rated for both natural and propane gas. A manual shutoff valve is also
provided with the flex line. The gas line shutoff valve provided with the fireplace has a 1/2” NPT thread inlet port.
WARNING
NOTE: Ensure the CPI/IPI switch is set to intermittent mode with the pilot in the OFF position. See control
compartment label for more information.
NOTE: A sediment trap is recommended in the gas piping within the home to prevent moisture and debris in the line
from damaging the valve.
NOTE: Secure all joints tightly using appropriate tools and sealing compounds. Ensure propane resistant compounds
36
are used in propane applications.
Innovative Hearth Products
Flex Line Connector
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
NOTE: Seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or
stuffed with unfaced fiberglass insulation.
1. Unscrew the shutoff valve from the gas flex-line. Apply thread sealant appropriate for the gas type, and then
connect the shutoff valve to the gas stub.
NOTE: Position the shutoff valve to allow easy operation through the access opening in the fireplace floor.
2. Connect the flare fitting on the flex-line to the shutoff valve. Tighten by hand, and then use a pipe wrench to
tighten completely, 1/4-turn at a time.
Figure 34: Gas Line ConnectionFigure 35: Electronic Pilot
1/2 x 3/8” Flare
1/2" x 3/8" Flare
shutoff valve
Shut-Off Valve
Gas
Gas
Stub
stub
Access the Control Compartment
See Page 52 for instructions on Accessing the Control Compartment.
The control valve has a 3/8” (10 mm) NPT thread inlet port. Secure all joints tightly using appropriate tools and sealing
compounds (ensure propane resistant compounds are used in propane applications). Optionally, seal around the gas line
to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fiberglass insulation.
All codes require a shutoff valve mounted in the supply line. The orientation of the shutoff valve should face the
front. Figure 34 illustrates two methods for connecting the gas supply. A sediment trap is recommended to prevent
moisture and debris in the gas line from damaging the valve.
3/8" NPT x 3/8"
3/8 NPT x 3/8”
Flare Fitting
Flare fitting
3/8" Flex Tubing
3/8” Flex tubing
Gas
GasValve
valve
Installation
900079-00, 02/2014
Igniter
Pilot Hood
Flame
Rod
Test Factory and Field Connections for Gas Leaks
Never use an open flame to check for leaks.
Turn on gas supply and test for gas leaks, using a gas leak test solution—also known as bubble leak solution.
NOTE: Using a soapy water solution is an effective leak test solution but it is not recommended, because the soap
residue that is left on the pipes/fittings can result in corrosion over time.
1. Light the fireplace (refer to the lighting instructions label in the control compartment or Page 62).
2. Brush all joints and connections with the gas leak test solution to check for leaks. If bubbles are formed, or gas
odor is detected, turn the receiver or remote control to the OFF position. Either tighten or refasten the leaking
connection, and then retest as described above.
3. When the gas lines are tested and leak free, rinse off the leak testing solution.
12. Verify Proper Fireplace Operation
1. With the gas line installed, inspect the system before closing the front of the unit.
2. Follow the pilot lighting instructions (Page 62).
NOTE: When lighting the fireplace for the first time, it will take a few minutes for the gas line to purge itself of air. When
purged, the pilot and burner will light and operate as indicated. Subsequent lighting of the fireplace will not require purging.
3. To light the burner, turn ON the wall or remote control switch. Ensure the igniter lights the pilot. The pilot flame
should engulf the flame rod (Figure 35).
13.
If necessary, Install the Firebox Floors
WARNING
1. See Page 54 for instructions on Installing and Removing the Firebox Floors.
NOTE: The firebox floors are factory-installed.
14.
If necessary, Install the Firebox Liners
1. See Page 55 for instructions on Installing the Firebox Liners, if necessary.
NOTE: The firebox liners are factory-installed.
37
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Install the Glass Media
15.
1. See Page 55 for instructions on Installing the Glass Media.
16. Install the Baffle
NOTE: The baffle is factory-installed. Remove to install the vent restrictor (Page 20).
1. With the baffle oriented as shown in Figure 36, slide the rear tabs into the slots in the back panel.
Figure 36: Baffle
Installation
900079-00, 02/2014
Firebox Ceiling
Clip
Baffle
Tabs
2. While sliding the tabs into the slots, slide the front lip of the baffle under the clips in the firebox ceiling.
17.
Install the Glass Door
1. See Page 56 for instructions on Installing and removing the glass door.
18. Adjust the Air Shutter to Ensure Proper Flame Appearance
sAir shutter adjustment should only be performed by a qualified professional service technician.
sEnsure glass door is in place and sealed during adjustment.
sSoot will be produced if the air shutter is closed too much. Any damage due to sooting,
resulting from improperly setting the air shutter, is not covered under the warranty.
sThe air shutter door and nearby appliance surfaces are hot. Exercise caution to avoid
injury while adjusting flame appearance.
Back Panel
WARNING
CAUTION
Flame Appearance and Sooting
The flame should be blue at the base, and yellow-orange in the body of the flame.
When the fireplace is first lit, the entire flame may be blue and will gradually turn yellow-orange during the first 30
minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air
shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at
the tips of very long orange flames. Sooting results in black deposits forming on the fireplace inside surfaces and on
exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter
opening. To achieve a warm yellow-orange flame with an orange body that does not soot, the shutter opening must
be adjusted between these two extremes.
38
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Air Shutter Adjustment Guidelines
s If there is smoke or soot present, first ensure that the flames are not impinging on any of the panels. If the
panels are properly positioned and a sooting condition still exists, increase the air shutter opening.
s The more offsets in the vent system, the wider the air shutter will need to be opened.
s The length and configuration of the chimney vent will afffect flame appearance.
s A fireplace operated with the air shutter opened too far may have flames that appear blue and transparent. These
weak, blue, and transparent flames are termed anemic.
s Propane models may exhibit flames that candle or appear stringy. If this condition is present and persists, adjust
the air shutter to a more open position, then operate the fireplace for a few more minutes to ensure that the
flame normalizes and the flames do not appear sooty. The following chart is provided to help achieve the correct
air shutter adjustment for your installation.
Ta bl e 25: Air Shutter Adjustment GuidelinesFigure 37: Air Shutter Adjustment
Amount of Primary
Air
If air shutter is
closed too far
If air shutter is
open too far
Flame ColorAir Shutter Adjustment
Flame will
be orange
Flame will
be blue
Air shutter gap should be increased:
PULL lever toward front of fireplace
Air shutter gap should be decreased:
PUSH lever toward back of fireplace
1. Move the adjustment lever (Figure 37) down to decrease air flow and up to increase it. Position the air shutter to
the factory setting (Table 26).
2. Light the fireplace. Follow the lighting procedure on the lighting label in the control compartment or Page 62.
3. Allow the burner to operate for at least thirty (30) minutes while observing the flame continuously to ensure that
the proper flame appearance is achieved (Figure 38). If the following conditions are present, adjust accordingly.
s If flame appears weak or sooty, adjust the air shutter, incrementally, to a more open position until the proper
flame appearance is achieved.
s If flame remains blue, adjust the air shutter, incrementally, to a more closed position until the proper flame
appearance is achieved.
4. When satisfied that the burner flame appearance is normal, proceed to finish the installation.
Installation
900079-00, 02/2014
Air shutter adjustment lever
(below glass door)
Figure 38: Flame Appearance
Ta bl e 26: Main Burner Shutter Opening—Factory Setting
ModelsNatural GasPropane
AllClosedClosed
39
Installation
900079-00, 02/2014
Innovative Hearth ProductsAstria™ Sirius Linear Direct-Vent Gas Fireplaces
40
19.
Install the Finishing Materials
NOTE: To install the fireplace facing flush with the finished wall, position framework to accommodate the thickness
of the finished wall.
NOTE: See Cold Climate Insulation on Page10 and Vent Termination Clearances on Page12.
1.Complete finished interior wall. Maintain a minimum 1” (25 mm) clearance from the door frame outer edge to
any finish material.NOTE: NEVER install combustible material (wall finish, surround, trim, etc.) on, in front of, or overlapping any
part of the fireplace front face.
Finishing without optional Surround—Cleanface Finish
1.Ensure the top and bottom nailing flanges are attached to the fireplace in the correct vertical position for a cleanface finish and the correct horizontal position for the wall finish material thickness (Page19).
2.Ensure the left and right side nailing flanges are properly installed (Page19).NOTE: The fireplace ships from factory with the flanges positioned for a cleanface installation.
3.Ensure the two filler/angle brackets are installed (Figure39). NOTE: Fireplace ships from factory with both filler/angle brackets installed. Do NOT remove brackets for
cleanface finish; they are required for proper combustion.
4.Attach the piece of fiber board to the top nailing flange and secure using installer-supplied screws (Figure40). NOTE: Install a second, field-supplied noncombustible board over the supplied noncombustible board. The
fireboard supplied with the unit is not intended to be the finish material.
5.Cover the lower portion of the fireplace with finish material.
6.Skim-coat all drywall, and mud all joints.NOTE: If skimming the provided fiber board to match drywall, use Sheetrock® brand Durabond®90 setting
type joint compound to fill all joints. These trademarks are owned by United States Gypsum Company or a relatedcompany.
7.For a painted wall finish, apply two (2) coats of quality primer and high-temperature paint.
8.After finishing all interior walls, install the glass door, if not already installed (Page56).
Figure39:Filler/Angle BracketsFigure40:Noncombustible Material with Cleanface Finish
Noncombustible board (secured to nailing flange)
Innovative Hearth Products
Min. 1"
(25 mm)
Min. 3"
(76 mm)
Top Nailing Flange*
Bottom Nailing Flange*
Spacer
Combustible material NOT ALLOWED
BELOW THIS POINT on face of unit.
Lip on Top Nailing Flange
Bottom edge of Fiber Board abuts lip.
Combustible Wall Finish Material
Top Non-Combustible
Fiber Board (provided
with fireplace)
Wall
Stud
*
*
Insulation and combustible
material NOT ALLOWED in clearance zones around vent components.
*
Header
Header
*Position of Top and Bottom Nailing Flanges depends on type and thickness of wall finish. See “UNIT NAILING FLANGES” section.
For Surround finish,cut Top Fiber Board to height of installedTop Spacers.
Combustible
material
NOT ALLOWED
BELOW THIS
POINT on
face of unit.
Side Non-Combustible
Fiber Board (one of two;
provided with fireplace)
Minimum 6"
Vertical Vent
and 90° Elbow
Min. 1"
(25 mm)
Min. 3"
(76 mm)
Spacer
WallStud
*
*
Minimum 6"Vertical Vent
and 90° Elbow
Header
*Position of Top
and Bottom Nailing
Flanges depends on
type and thickness
of wall finish. See
“UNIT NAILING
FLANGES” section.
For Surround finish,
cut Top Fiber Board
to height of installed
Top Spacers.
Combustible
material
NOT ALLOWED
BELOW THIS
POINT on
face of unit.
Min. 1"
(25 mm)
Min. 3"
(76 mm)
Spacer
Wall
Stud
*
*
Minimum 6"Vertical Vent and 90° Elbow
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Installation
900079-00, 02/2014
Figure 41: Noncombustible Material with Cleanface Finish—
Profile View
* 6” straight vent section
required before 90° elbow.
** Insulation and combustible
materials not allowed in
clearance zones around vent
components.
**
Figure 42: Noncombustible Material with Surround—
Profile View
* 6” straight vent
section required before
90° elbow.
** Insulation and
combustible materials
not allowed in clearance
zones around vent
components.
**
Finishing with optional Surround
1. Ensure the top and bottom nailing flanges are attached to the fireplace in the correct vertical position for
2. Ensure the left and right side finishing flanges are removed, and discarded appropriately (Page 19).
3. Remove the two filler/angle brackets (Figure 39), and discard appropriately.
4. Attach the top non-combustible fiber board to the top nailing flange, and secure using installer-supplied screws
surround finish and the correct horizontal position for the wall finish material thickness (Page 19).
(Figure 43). Discard the two smaller side non-combustible fiber boards (not used with surround).
NOTE: The provided non-combustible fiber board may be faced with any NON-combustible finish material
appropriate for use (brick, tile, stone, high-temperature paint, etc.). For painted wall finish, use two (2) coats of
quality primer and high-temperature paint on provided fiber board.
5. Cover the lower portion of the fireplace with finish material.
6. Skim-coat all drywall, and mud all joints.
NOTE: If skimming the provided fiber board to match drywall, use Sheetrock® brand Durabond® 90 setting
type joint compound to fill all joints. These trademarks are owned by United States Gypsum Company or a
related company
7. After finishing all interior walls, install the glass door, if not already installed (Page 56).
8. Attach the surround, and secure using the nine (9) screws provided with the surround kit (Figure 44).
41
Installation
900079-00, 02/2014
Innovative Hearth ProductsAstria™ Sirius Linear Direct-Vent Gas Fireplaces
42
Figure43:Noncombustible Material with SurroundFigure44:Installing the Surround
Remove Left (and Right) Filler/Angle Brackets.
Bezel
Noncombustible board (cut to height of standoffs)
Fillerangle bracket
Finishing
flange
Nailing
flange
Figure45:Wall Receiver SwitchFigure46:Remote Control Transmitter
REMOTE
OFF
ON
Burner ON/OFF
Safetylock switch
20.Optional: Install the Modesty Panel
NOTE: Do NOT install the modesty panel if using the surround.
1.Insert the hooks on the modesty panel into the slots on the door flange (Figure47).
Figure47:Installing the Modesty Panel
Modesty Panel
Hook on
modesty panel
Slot on
doorflange
2.Slide the modesty panel to the left until it is fully seated (Figure47).
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Install the Wall Switch Receiver
21.
1. When wall finish is complete, install the wall switch receiver in the previously installed junction box, and connect
the 2-wire terminal to the connector on the back of the receiver.
2. Install the receiver cover plate. Ensure the receiver switch is properly aligned with the switch cover
22. Initialize the Remote Control System
After completing fireplace installation, initialize the remote control system before operating the fireplace. See the
Operation section on Page 50 for more details.
1. Insert the three (3) provided AAA batteries into the battery bay in the remote control (Figure 46). Correctly align polarity (+/–).
2. Insert the (4) provided AA batteries into the receiver battery bay (behind the wall switch plate). Correctly align polarity (+/–).
3. Position the wall switch receiver three-position slider switch in the REMOTE position (Figure 45).
4. On the remote control, press the ON button (Figure 46).
Attach the Safety-in-Operation Warning Labels
23.
1. Attach the furnished safety instruction labels at all fireplace operation and control points (Page 44).
NOTE: The installer MUST ensure these warnings are properly attached during installation. The warning labels are a
critical means of informing consumers of safe operation practices.
Installation
900079-00, 02/2014
43
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Installation
ATTACH THE SAFETY-IN-OPERATION WARNINGS
NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a
critical step in informing consumers of safe operation of this fireplace.
Attaching Safety-in-Operation Warnings
It is required that the set of safety instruction
labels that have been furnished with the fireplace
be affixed to the operation and control points of
the fireplace. A safety instruction label must be
affixed to the receiver wall switch plate where
the fireplace is turned on and off (Figure A)
and on the remote control handheld transmitter
(Figure B). To properly complete the installation
of this fireplace, locate the multilingual adhesive
labels provided with the Care and Operation
Instructions and proceed as follows:
1. Locate the wall receiver that controls the
fireplace (verify the switch operates the
fireplace by turning it on and off). Clean the
wall receiver plate thoroughly to remove
any dust and oils. Affix the label to the
surface of the plate of the wall receiver that
controls the fireplace (Figure A). Choose the
language primarily spoken in the home. If
unknown, affix the English language label.
2. Locate the remote control transmitter and
clean it thoroughly to remove any dust
and oils. Affix the label to the surface of
handheld transmitter (Figure B). Choose the
language primarily spoken in the home. If
unknown, affix the English language label.
3. If you are unable to locate the labels, please
call Innovative Hearth Products or your
nearest Innovative Hearth Products dealer
to receive additional safety instruction labels
free of charge.
Cat. No. H8024 Replacement Label Kit Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024
NOTE: English is red text on clear label. French
and Spanish are white text on black label.
SAFETY LABEL DIAGRAMSDIAGRAMMES DES ÉTIQUETTES DE SÉCURITÉDIAGRAMAS DE ETIQUETAS DE SEGURIDAD
Apposition des mises en garde relatives
à la sécurité d’utilisation
Il est impératif que le jeu d’étiquettes de sécurité
qui ont été fournies avec le foyer soient collées
à côté des dispositifs de contrôle du foyer. Une
étiquette de sécurité doit être collée sur la plaque
du récepteur mural contrôlant l’allumage du foyer
(Figure A) et sur le boîtier de la télécommande
(Figure B). Pour achever l’installation correcte de
ce foyer, procédez comme suit avec les étiquettes
adhésives en langues étrangères fournies avec
les instructions d’utilisation et d’entretien :
1. Repérez le récepteur mural qui contrôle le
foyer (vérifiez que l’interrupteur contrôle
le fonction- nement du foyer en le faisant
basculer de Marche à Arrêt, et vice-versa).
Nettoyez soigneusement la plaque du
récepteur mural pour éliminer la poussière
et les traces de graisse ou d’huile. Collez
l’étiquette sur la surface de la plaque
du récepteur mural qui contrôle le foyer
(Figure A). Choisissez la langue qui est
principalement parlée dans la résidence du
propriétaire. En cas de doute, collez l’étiquette
en anglais.
2. Repérez la télécommande et nettoyez-la
soigneusement pour éliminer la poussière
et les traces de graisse ou d’huile. Collez
l’étiquette sur le boîtier de la télécommande
(Figure B). Choisissez la langue qui est
principalement parlée dans la résidence
du propriétaire. En cas de doute, collez
l’étiquette en anglais.
3. Si vous ne trouvez pas les étiquettes, veuillez
appeler Innovative Hearth Products ou votre
distributeur Innovative Hearth Products local
pour recevoir gratuitement des étiquettes
supplémentaires.
Remarqué : Le texte anglais est rouge sur un
support transparent. Le texte français et espagnol
est blanc sur un support noir.
Colocación de advertencias de
seguridad en operación
Se requiere que el juego de etiquetas de
instrucciones de seguridad que se incluyeron con la
chimenea se coloque en los puntos de operación y
control de la misma. Se debe colocar una etiqueta
de instrucciones de seguridad en la placa del
interruptor de pared del receptor desde el cual
se enciende y se apaga la chimenea (Figura A)
y en el transmisor de control remoto (Figura B).
Para completar correctamente la instalación de
esta chimenea, encuentre las etiquetas adhesivas
multilingües incluidas con las instrucciones de
cuidado y operación y haga lo siguiente:
1. Identifique el receptor de pared que
controla la chimenea (verifique que el
interruptor opera la chimenea encendiéndola
y apagándola). Limpie bien la placa del
receptor de pared para quitar el polvo y
aceite. Pegue la etiqueta en la superficie de
la placa del receptor de pared que controla
la chimenea (Figura A). Seleccione el idioma
que más se habla en la casa. Si no sabe cuál
es, use la etiqueta en inglés.
2. Identifique el transmisor de control remoto
y límpielo bien para quitar el polvo y aceite.
Pegue la etiqueta en la superficie del
transmisor (Figura B). Seleccione el idioma
que más se habla en la casa. Si no sabe cuál
es, use la etiqueta en inglés.
3. Si no puede encontrar las etiquetas, sírvase
llamar a Innovative Hearth Products o al
distribuidor de Innovative Hearth Products
más cercano para recibir etiquetas de
instrucciones de seguridad adicionales
gratuitas.
Nota: La etiqueta en inglés es transparente con
texto rojo. Las etiquetas en francés y español son
negras con texto blanco.
Illustrations are for example only.
Your accessories may be different.
Les illustrations sont par exemple
uniquement. Vos accessoires
peuvent être différents.
Las ilustraciones son sólo ejemplos.
Tu accesorios pueden ser diferentes.
44
Figure A
Figura A
Innovative Hearth Products
ON
REMOTE
OFF
Figure B
Figura B
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
These termination kits include firestop/spacer, gear clamps, and flex adaptor.
60L10SF-18
98K03SF-12
H2248SF4.5HF-10
H2249SF4.5VF-10
H1969SF4.5HT-2
77L87SFKIT12S
77L88SFKIT18S
77L89SFKIT24S
77L90SFKIT36S
77L91SFKIT48S
91L66SFGC4-6
91L67SFGC7-6
ModelDescription
18 ft (5.49 m)* compressed flex
(see 750053M)
12 ft (3.66 m)*compressed flex
(see 750052M)
Firestop/Spacer, Horizontal, flex
(3-1-1 spacing), 10 Pack
Firestop/Spacer, Vertical, flex (1-1-1
spacing),10 Pack
Horizontal Square Termination for
flex (without flex)
Square Term. for flex with
12” (305 mm)* compressed flex
Square Term. for flex with
18” (457 mm)* compressed flex
Square Term. for flex with
24” (610 mm)* compressed flex
Square Term. for flex with
36” (914 mm)* compressed flex
Square Term. for flex with
48” (1219 mm)* compressed flex
Gear Clamp 4.5” (114 mm) for flex
(6-pack)
Gear Clamp 7.5” (190.5 mm) for
flex (6 pack)
10K81SFMP
Mill-Pac, Black, High-
Temperature Sealant
Mill-Pac, Black, High-
89L40SFMP-12
H1988CTSA-33
H1985CTSO-33
H1987CTSO-44
H1986CTSO-46
Catalog
Number
ModelDescription
Temperature Sealant
Chase Top Shroud Kit,
Chase Top Shroud Kit,
Chase Top Shroud Kit,
Chase Top Shroud Kit,
Small Square Termination for flex,
94L04 **SFKIT12SS
with 12” (305 mm) of *compressed
flex vent (see 750204M)
Small Square Termination for flex,
94L05 **SFKIT18SS
with 18” (457 mm) of *compressed
flex vent (see 750204M)
Small Square Termination for flex,
94L06 **SFKIT24SS
with 24” (610 mm) of *compressed
flex vent (see 750204M)
Small Square Termination for flex,
94L07 **SFKIT36SS
with 36” (914 mm) of *compressed
flex vent (see 750204M)
Small Square Termination for flex, with
94L08 **SFKIT48SS
48” (1219 mm) of *compressed flex
vent (see 750204M)
Horizontal Small Square Termination
94L09 **SF-HTSS
for flex, without flex vent
(see 750204M)
Vertical Termination for flex (flat to 6/12)
56L74SFVT30
with flex adaptor, section of rigid vent, roof
support collar assembly, roof flashing and
storm collar. (see 750052M)
Vertical Termination for flex (6/12 to 12/12)
56L75SFVT45
with flex adaptor, section of rigid vent, roof
support collar assembly, roof flashing and
storm collar. (see 750052M)
36” Flex Connector Kit.
H7748H7748
36” of flex with two adaptors for
mating two rigid sections of vent
together.
* All compressed flex vents can be expanded up to two times.
** Small square termination is only approved for use with 42” models.
(bulk 12-pack)
Arch Top, 3 x 3 ft
Open Top, 3 x 3 ft
Open Top, 4 x 4 ft
Open Top, 4 x 6 ft
46
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Installation
GAS CONVERSION KITS
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly, a fire, explosion, or the production of carbon
monoxide may result; causing property damage, personal injury, or loss of life. The qualified service agency
is responsible for the proper installation of this kit. The installation is not proper and complete until the
operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with
the kit.The qualified service agency performing this installation assumes responsibility for this conversion.
AVERTISSEMENT
Cette trousse de conversion doit être installée par un technicien agréé, selon les instructions du fabricant
et selon toutes les exigences et tous les codes pertinents de l’autorité compétente. Assurez-vous de bien
suivre les instructions dans cette notice pour réduire au minimum le risque d’incendie, d’explosion ou la
production de monoxyde de carbone pouvant causer des dommages matériels, des blessures ou la mort.
Le tecnicien agréé est responsable de l’installation de cette trousse. L’installation n’est pas adéquate ni
complète tant que le bon fonctionnement de l’appareil converti n’a pas été vérifié selon les instructions du
fabricant fournies avec la trousse. Le fournisseur de service qualifié ayant réalisé l’installation assume les
responsabilités liées à la conversion.
In Canada:
The conversion shall be carried out in accordance with the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements of the CAN/CGA-B149.1 Installation code.
La conversion devra être effectuée conformément aux recommandations des autorités provinciales ayant
juridiction et conformément aux exigences du code d’installation CAN/CGA-B149.1.
Gas conversion kits are available to adapt your fireplace from the use of one type of gas to the use of another. These
kits contain all the necessary components needed to complete the task including labeling that must be affixed to
ensure safe operation.
Refer to the instructions provided with the conversion kit when performing any gas conversion.
Ta bl e 29: Electronic Systems, Natural Gas To Propane Gas Conversion Kits
Model NumberModel NumberCatalog Number
42”GCK-LDV42NPH8706
54”GCK-LDV54NPH8702
Ta bl e 30: Electronic Systems, Propane Gas To Natural Gas Conversion Kits
Model NumberModel NumberCatalog Number
42”GCK-LDV42PNH8705
54”GCK-LDV54PNH8701
47
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Installing Gas Conversion Kits
The gas supply shall be shut OFF prior to disconnecting the electrical power, before
proceeding with the conversion.
Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez
l’alimentation electrique.
1. TURN OFF THE GAS SUPPLY TO THE FIREPLACE and disconnect power supply at the circuit breaker. Ensure
fireplace is cold.
2. If installed, remove the surround (Figure 44).
3. Remove the glass door (Page 56).
4. Remove the glass media (Page 59).
5. Remove the front and rear floor sections (Page 54).
6. Remove the two (2) screws securing the burner assembly. Remove the burner assembly with the attached
venturi tube (Figure 48).
7. Remove the control compartment access door and gasket (Figure 48).
Installation
900079-00, 02/2014
WARNING
AVERTISSEMENT
Figure 48: Removing the Burner and Accessing the Control CompartmentFigure 49: Removing the Air Shutter
Adjustment Rod
Remove two screws
to remove burner
assembly.
Burner
Assembly
Air Shutter
Adjustment
Rod
Venturi
Right Burner
Bracket
Burner
Orifice
Control Compartment
Access Panel and Gasket
8. Refer to the instructions provided with the regulator conversion kit. Using a Torx T20 driver (with 1/4” shank)
or slotted screwdriver, remove and discard the two (2) pressure regulator mounting screws, pressure regulator
tower, the diaphragm assembly (if applicable) and the spring. Ensure the rubber gasket installed on the back of
the replacement pressure regulator is properly positioned. Discard all removed components.
9. Install the new pressure regulator assembly using the supplied screws. Tighten the screws to 25 in. lbs.
48
10. Install the enclosed identification label to the valve body where it can be easily seen.
Right Burner Bracket
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
11. Make valve electrical connections.
12. Remove the pilot hood assembly to access the hex pilot orifice (Figure 50). Remove and replace the pilot
orifice with the one provided with the kit. Exercise extreme care to prevent damage to or breakage of the
igniter assembly.
13. Remove the burner orifice from the manifold and replace it with the one provided in the kit (Figure 51).
NOTE: See Table 5 for burner orifice sizes.
Figure 50: PilotFigure 51: Orifice
14. Apply pipe joint compound or Teflon® tape to all pipe fittings before installing.
NOTE: Ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds
on flare fittings.
15. Reinstall the control compartment access door and gasket. Secure using the twelve (12) screws removed
previously (Figure 48).
16. Reinstall the air shutter adjustment lever.
17. Place the burner assembly into position. Replace the screws securing the burner to the burner brackets
(Figure 48).
Installation
900079-00, 02/2014
Pilot
Hood
Pilot
Orifice
NOTE: Ensure the air shutter clears the pilot bracket.
18. Turn ON the gas supply to the fireplace and relight the appliance (Page 62). With the main burner ON, use a gas leak test solution to test the new pressure regulator assembly and all gas line joints for leaks (Page 37).
19. Attach the conversion information label to the rating plate.
20. Locate the valve test ports (Figure 1). Using a manometer, test the inlet and manifold gas pressures (Table 3 and
Table 4).
NOTE: Always test pressures with the valve regulator control at the highest setting.
21. Reinstall the media and glass door .
22. Relight the main burner and verify proper burner ignition and operation (Page 37).
23. Inspect the pilot system for proper flame. The pilot flame should engulf the flame sensor (Figure 35).
24. Turn OFF the gas supply to the fireplace.
25. Turn ON the gas supply to the fireplace. Use a gas leak test solution to test the NPT plugs for leaks.
26. Read Flame Appearance and Sooting and Air Shutter Adjustment Guidelines before proceeding. Before
adjusting the air shutter, allow the burner to operate for at least thirty (30) minutes while continuously observing
the flame.
27. Adjust the air shutter using the lever located just under the door, slightly right of center (Page 38).
28. Reinstall the surround.
49
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Operation
OPERATION
WARNING
Young children should be carefully supervised when they are in the same room as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install
an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and
away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que
l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en
contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes
à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de
sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque
d’avoir accès à la pièce et aux surfaces chaudes.
WARNING
Do not operate the fireplace if:
sThe glass front is removed, cracked, or broken
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with
headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas
supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly.
Some people are more affected by carbon monoxide than others, including pregnant women, people with heart
or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
NOTE: Do not place furniture or other combustible materials within 36” of the front of viewing area(s).
NOTE: Children and adults should be alerted to the hazards of high surface temperature and should stay away to
avoid burns or clothing ignition.
Remarqué : Les enfants et les adultes devraient être infor-més des dangers que posent les températures de
surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
NOTE: Installation and repair should be done by a qualified service person. The fireplace should be inspected before
use and at least annually by a professional service person. More frequent cleaning may be required due to excessive
lint from carpeting, bedding material, etcetera. It is imperative that control compartments, burners and circulating air
passageways of the fireplace be kept clean.
Remarqué : L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire
l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité
importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil soient tenus propres.
NOTE: Do not use these fireplaces if any part has been under water. Immediately call a qualified, professional service
technician to inspect the fireplace and to replace any parts of the control system and any gas control which have
been under water.
Remarqué : Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien qualifié pour
inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.
50
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Operation
ATTACH THE SAFETY-IN-OPERATION WARNINGS
NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a
critical step in informing consumers of safe operation of this fireplace.
Attaching Safety-in-Operation Warnings
Your fireplace has been furnished with safety
instruction labels that are to be affixed to the
operation and control points of the fireplace. A
safety instruction label should be affixed to the
receiver wall switch plate where the fireplace
is turned on and off (Figure A) and the remote
control handheld transmitter (Figure B). The
warnings should already have been put in place
when the fireplace initial set-up was completed.
If they are not affixed at these spots, locate the
multilingual adhesive labels provided with these
instructions and proceed as follows:
1. Locate the wall receiver that controls the
fireplace (verify the switch operates the
fireplace by turning it on and off). Clean the
wall receiver plate thoroughly to remove
any dust and oils. Affix the label to the
surface of the plate of the wall receiver that
controls the fireplace (Figure A). Choose the
language primarily spoken in the home.
2. Locate the remote control transmitter and
clean it thoroughly to remove any dust
and oils. Affix the label to the surface of
handheld transmitter (Figure B). Choose the
language primarily spoken in the home.
3. If you are unable to locate the labels, please
call Lennox Hearth Products or your nearest
Lennox Hearth Products dealer to receive
additional safety instruction labels free
of charge.
Cat. No. H8024 Replacement Label Kit Étiquettes de remplacement, n° cat. H8024 Juego de etiquetas de repuesto - Nº de cat. H8024
NOTE: English is red text on clear label. French
and Spanish are white text on black label.
SAFETY LABEL DIAGRAMSDIAGRAMMES DES ÉTIQUETTES DE SÉCURITÉDIAGRAMAS DE ETIQUETAS DE SEGURIDAD
Apposition des mises en garde relatives
à la sécurité d’utilisation
Votre foyer a été livré avec des étiquettes de
sécurité qui doivent être collées à côté des
dispositifs de contrôle du foyer. Une étiquette
de sécurité devrait être collée sur la plaque du
récepteur mural contrôlant l’allumage du foyer
(Figure A) et sur le boîtier de la télécommande
(Figure B). Les mises en garde auraient dû être
collées au moment de l’installation initiale du
foyer. Si ce n’est pas le cas, prenez les étiquettes
adhésives multilingues fournies avec ces
instructions et procédez comme suit :
1. Repérez le récepteur mural qui contrôle le
foyer (vérifiez que l’interrupteur contrôle le
fonctionnement du foyer en le faisant basculer
de Marche à Arrêt, et vice-versa). Nettoyez
soigneusement la plaque du récepteur mural
pour éliminer la poussière et les traces de
graisse ou d’huile. Collez l’étiquette sur la
surface de la plaque du récepteur mural qui
contrôle le foyer (Figure A). Choisissez la
langue qui est principalement parlée dans la
résidence du propriétaire.
2. Repérez la télécommande et nettoyez-la
soigneusement pour éliminer la poussière
et les traces de graisse ou d’huile. Collez
l’étiquette sur le boîtier de la télécommande
(Figure B). Choisissez la langue qui est
principalement parlée dans la résidence
du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez
appeler Lennox Hearth Products ou votre
distributeur Lennox Hearth Products local
pour recevoir gratuitement des étiquettes
supplémentaires.
Remarqué : Le texte anglais est rouge sur un
support transparent. Le texte français et espagnol
est blanc sur un support noir.
Colocación de advertencias de
seguridad en operación
Su chimenea incluye etiquetas de instrucciones de
seguridad que deben colocarse en los puntos de
operación y control de la chimenea. Se debe colocar
una etiqueta de instrucciones de seguridad en la
placa del interruptor de pared del receptor desde el
cual se enciende y se apaga la chimenea (Figura A)
y en el transmisor de control remoto (Figura B).
Las advertencias ya deben haberse colocado
cuando se completó la instalación inicial de la
chimenea. Si no están colocadas en estos lugares,
encuentre las etiquetas adhesivas multilingües
proporcionadas con estas instrucciones y prosiga
de la siguiente manera:
1. Identifique el receptor de pared que
controla la chimenea (verifique que el
interruptor opera la chimenea encendiéndola
y apagándola). Limpie bien la placa del
receptor de pared para quitar el polvo y
aceite. Pegue la etiqueta en la superficie de
la placa del receptor de pared que controla
la chimenea (Figura A). Seleccione el idioma
que más se habla en la casa.
2. Identifique el transmisor de control remoto
y límpielo bien para quitar el polvo y aceite.
Pegue la etiqueta en la superficie del
transmisor (Figura B). Seleccione el idioma
que más se habla en la casa.
3. Si no puede encontrar las etiquetas,
sírvase llamar a Lennox Hearth Products
o al distribuidor de Lennox Hearth
Products más cercano para recibir
etiquetas de instrucciones de seguridad
adicionales gratuitas.
Nota: La etiqueta en inglés es transparente con
texto rojo. Las etiquetas en francés y español son
negras con texto blanco.
Illustrations are for example only.
Your accessories may be different.
Les illustrations sont par exemple
uniquement. Vos accessoires
peuvent être différents.
Las ilustraciones son sólo ejemplos.
Tu accesorios pueden ser diferentes.
Figure A
Figura A
Innovative Hearth Products
ON
REMOTE
OFF
Figure B
Figura B
51
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Burn-in Period
The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the
lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a
few days.
NOTE: Ventilate the site during the burn-in period. The resulting odor and haze may set off a smoke detector. Do not
operate the optional blower, if installed, during the burn-in period.
A white film may develop on the glass front during the first few fires as part of the burn-in period. The glass
should be kept clean during the burn-in period to prevent the film from baking on—making it very difficult to
remove (Cleaning the glass door and firebox on Page 58).
Accessing the Control Compartment
Access the control compartment (Figure 53) by removing the following components, as necessary, in this order:
1. Surround (optional) (Figure 44)
2. Glass door (Page 56)
3. Floor components (Page 54)
4. Burner
a. Remove the two (2) 5/16” screws securing the burner to the burner brackets.
b. Carefully slide the burner to the left, to clear the venturi from the orifice.
c. Rotate the burner to release the air shutter adjustment rod from the air shutter lever.
d. Set aside screws and burner assembly in a secure location for later reinstallation.
5. Control compartment access panel
a. Remove the control compartment access panel and gasket by removing the twelve (12) screws, and set
aside for later reinstallation.
b. The gas valve can be accessed through the opening, or the complete assembly can be removed by sliding
the assembly to the right.
Operation
900079-00, 02/2014
Figure 52: Accessing the control compartment
Closing the Control Compartment
Reinstall the items removed in Accessing the Control Compartment, in reverse order.
Gas Controls
Shutoff Valves
As part of your fireplace installation, the installer may have provided a readily accessible gas shutoff valve near
your fireplace. Make sure this valve is fully open before operating the fireplace. If gas is not flowing to the pilot and
burner, the service shutoff valve located in the fireplace control compartment may need to be opened. Contact your
dealer or distributor for more information.
To access the service shutoff valve, remove the glass door, burner, floor panels, and control compartment access
panel in the fireplace floor.
Remote Control System
The remote control system provides remote operation of the following fireplace functions:
s Primary burner ON/OFF
The wall switch receiver accepts commands via radio frequency from the remote control transmitter and does not
require line-of-sight operation. The slider switch on the receiver can be set to one of three positions:
s ON (manual override)
52
s OFF (manual override)
s REMOTE (remote control)
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Detailed lighting instructions are found on Page 62. Also, electronic fireplace lighting instructions are attached to
the CPI/IPI switch bracket.
The fireplace main burner can be turned ON/OFF with the wall switch or remote control. Check the batteries, at least
every three (3) months to ensure they are properly charged (Figure 2).
To light the fireplace in a power outage:
1. Confirm that batteries are installed in the battery pack.
2. Set the unit-mounted switch, or wall switch to the ON Position.
3. The unit should spark at the pilot and light.
NOTE: If there is no spark, replace the batteries.
4. Operate the fireplace normally.
NOTE: Install new batteries (4 AA) in the battery holder before the burn season (Page 36). Then, the fireplace can
automatically switch to battery power in the event of a power outage.
900079-00, 02/2014
WARNING
Fire hazard. Can cause severe injury or death. The wall switch receiver causes ignition of the appliance. The
appliance can turn on suddenly. Keep away from the appliance burner when operating the remote system or
activating manual bypass of the remote control system.
Operation
WARNING
Property damage hazard. Excessive heat can cause property damage. The appliance can stay lit for many
hours. Turn OFF the appliance if it is not going to be attended for any length of time. Always place the
remote control transmitter where children cannot reach it.
Wall Switch Receiver Low Battery Power Detection
Battery life depends on several factors, including battery quality and number of fireplace ignitions. When the
batteries are low or depleted, the fireplace can only be operated manually (ON/OFF). When the receiver batteries are
low, it will emit three (3) beeps to alert of low batteries whenever the receiver ON/OFF button is pressed. When the
depleted batteries are replaced, the receiver will resume normal operation.
Remote Control Transmitter Low Battery Power Detection
When the transmitter batteries are low, the LED light will dim to alert of low batteries before losing all power. When
the depleted batteries are replaced, the transmitter will resume normal operation. Battery life depends on several
factors, including battery quality and number of fireplace ignitions. When the batteries are low or depleted, the
fireplace can only be operated manually (ON/OFF).
1. Replace the three (3) AAA batteries in the handheld remote control.
Remotely Turning ON the Appliance
1. Slide the wall switch to the REMOTE position (Figure 45).
2. Press the remote control ON/OFF key (Figure 46).
3. Two (2) beeps from the receiver will confirm receipt of the command, and the burner will light.
Remotely Turning OFF the Appliance
1. Press the remote control ON/OFF key (Figure 46).
2. The wall switch receiver will beep two (2) times, and the burner will turn OFF.
Key Lock
The key lock function disables the remote control keys to prevent unintended operation.
1. To activate or deactivate the key lock function, slide the safety lock switch to the desired position(Figure 46).
53
Operation
900079-00, 02/2014
Innovative Hearth ProductsAstria™ Sirius Linear Direct-Vent Gas Fireplaces
54
Continuous Pilot Ignition / Intermittent Pilot Ignition Switch
These fireplaces have a continuous pilot ignition (CPI) / intermittent pilot ignition (IPI) switch installed under the door. This switch allows the pilot to be switched from intermittent mode to continuousmode:
sIntermittent Mode—The pilot is extinguished when the fireplace is OFF.sContinuous Mode—The pilot stays ON when the fireplace is OFF.
Inperiodsofextremecold,condensationmayformontheglassdoorwhenthefireplaceisOFFandthepilotisin intermittent mode. Also, with the pilot in intermittent mode, the fireplace may cycle startup (i.e., the pilot and burner ignite, but the burner extinguishes and reignites several times until the flue reaches the temperature for properdrafting).
sTo save energy—switch to intermittent mode. sFor a standing pilot that will help prevent glass door condensation and cycle startup—switch to continuous mode.
NOTE: Continuous mode is indicated by a pilot that comes ON and remains lit when the fireplace is OFF.
Figure53:Control Compartment
ON
OFF
CPI/IPI switch*ON = standingOFF = intermittent
Main gas shutoff valve
Installing and Removing the Firebox Floors
Installing the rear firebox floor
1.Place the lower back edge of the rear firebox floor on the rear ledge, behind the tabs.
2.Align the outermost front hole on either side of the rear floor with the hole in the center lower tab of each side
firebox liner panel. Pull the rear floor section forward until it butts against the burner. Secure the floor with three(3) of the included screws (Figure54).
Figure54:Installing the rear floorFigure55:Installing the front floor
Rear
firebox
floor
Rear
ledge
Tab
~
Side firebox
linerpanel
(center lower tab)
Locking clip
Front
ledge
Notch
Rear
firebox
floor
Front
firebox
floor
Lip
Installing the rear firebox floor
1.Engage the lower front lip of the front firebox floor under the locking clips attached to fireplace front ledge, and
then slide it back.
2.Align the notches in the back edge of the front firebox floor with the holes in the rear floor. Push the front floor
back until it butts against burner, and secure it with the included screws (Figure55).
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Installing the Firebox Liners
NOTE: It is not necessary to remove the firebox liner panels for most maintenance situations.
WARNING
sDo NOT attempt to install firebox liner panels until the fireplace is installed, the gas-line has been
connected and tested for leaks, and initial burner operation has been confirmed.
Install the side panels
1. Align screw hole in top flange of side panel with upper hole in inside wall of fireplace.
2. Align screw holes in bottom flanges of side panel with holes in front ledge and rear ledge.
3. Secure each panel with three (3) screws.
Install back panel
1. Insert bottom edge of back panel into fireplace. Lift it over the tabs on rear ledge of fireplace.
2. Align screw holes in top and bottom edges of back panel with holes in fireplace ceiling and rear ledge. Secure
using seven (7) screws.
Installing the Glass Media
Installation
WARNING
sThe glass media was designed to provide a safe, reliable, attractive flame. Any attempt to use media not specified for
this fireplace will result in incomplete combustion, sooting, poor flame quality, and will void the warranty.
sGlass media gets very HOT during fireplace use and will remain hot up to ONE HOUR after gas supply is turned
off. HANDLE MEDIA ONLY WHEN COOL. Turn OFF all electricity to the appliance before installing media.
s If glass media is not installed according to the installation instructions, flame impingement and improper combustion could
occur, resulting in soot and/or excessive production of carbon monoxide (CO), a TOXIC gas that is colorless and odorless.
sThis appliance is NOT designed to burn wood. Any attempt to burn wood in this fireplace may be a safety
hazard, cause irrepairable damage the appliance, and void the warranty.
1. Install the glass media in the recessed area between the front and rear floors.
NOTE: 42” fireplaces require a full bag of glass media. 54” fireplaces require two (2) full bags of media.
2. Spread the glass media in a thin layer, evenly around the burner (Figure 56). Do NOT mound the media.
Figure 56: Installing the glass media
Do NOT place
Glass media area
media on burner or
around pilot.
55
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Installing and removing the glass door
900079-00, 02/2014
Operation
WARNING
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED.
sRemove glass door only when fireplace is OFF and COLD.
sFireplace surfaces get EXTREMELY HOT!
sThe glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns
if touched. Even after the gas is turned off, fireplace surfaces remain extremely hot.
WARNING
sDo not attempt to substitute the materials used on these doors, or replace cracked or broken glass.
sHandle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly
while reinstalling the glass door frame.
sThe glass door of this appliance must only be replaced as a complete unit as provided by the
manufacturer. Do not attempt to replace broken, cracked or chipped glass separately.
sDo not attempt to touch the front enclosure glass with your hands while the fireplace is in use.
WARNING
Do not operate appliance with the glass front removed, cracked, or broken.
AVERTISSEMENT
Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué, ou brisé.
WARNING
Any safety screen or guard removed for servicing the appliance must be replaced prior to operating
the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de
mettre l’appareil en marche.
Only doors certified with the fireplace shall be used.
Seules des portes certifiées pour cet appareil doivent être utilisées.
CAUTION
Do NOT abuse the glass door by striking it or slamming it shut.
56
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Installing the glass door
1. Visually inspect the gasket on the backside of the glass door.
NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
Make sure the bead is not rolled into the channel at the top of the door, but remains flat against the top of
the glass.
2. While holding the glass door by the sides, hook the top edge onto the fireplace, and swing the bottom of the
glass door gently in towards the fireplace ensuring that the gasket seats evenly as the door draws shut.
NOTE: If the lower flange of the door does NOT clear the lower front frame of the fireplace, ensure the door
UPPER mounting flange is completely and properly engaged on the fireplace frame BEFORE INSERTING THE
SCREWS. Proper door alignment and sealing are important to the operation and performance of the fireplace.
Ensure the door seal is contacting the frame and that no air leaks are present.
3. Align the screw holes below the glass door with the holes in the fireplace, and secure using the three (3)
provided screws (Figure 57).
4. For cleanface installations, install the modesty panel (Page 42).
Removing the glass door
1. For cleanface installations, remove the modesty panel (Page 42).
2. Remove the three (3) screws beneath the door (Figure 57).
3. Swing the bottom of the glass door away from the fireplace to a 45° angle.
4. Carefully grip the door at the top and bottom, and remove it from the fireplace. Place the door in a safe location
for later reinstallation.
Operation
900079-00, 02/2014
Figure 57: Glass Door
Glass Door
Rating plate and lighting instructions
are attached to door bracket.
57
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
MAINTENANCE
Refer to the Maintenance Schedule on Page 60 for maintenance tasks, procedures, frequency, and a listing of by
whom the tasks should be performed. Always verify proper fireplace operation after servicing.
Turn OFF gas and electrical power to the fireplace and allow it to cool before cleaning or
servicing the appliance.
Wear gloves and safety glasses for protection while doing required maintenance.
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
Always turn OFF gas before cleaning. Before relighting, refer to the lighting instructions in this manual.
Instructions are also found on a pull-out panel located in the control compartment.
Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
NOTE: Prior to the first use of the fireplace and each burn season and periodically during the burn season, inspect the
horizontal termination for debris such as bird nests, leaves, paper or branches. Remove any items from the surfaces of the
termination prior to use. Also be aware of shrubs and plantings that may encroach on the termination.
Operation
900079-00, 02/2014
WARNING
CAUTION
Inspecting the venting system
The fireplace and venting system should be thoroughly inspected before initial use and at least annually by a qualified
service technician. Inspection should include ensuring that exhaust or intake passages are unobstructed and vent
components are properly assembled and not damaged.
The homeowner must contact a qualified service technician at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualified service technician should follow vent installation
instructions for proper reassembly and proper sealing of the venting system components. However, more frequent
periodic inspections and cleanings should be performed by the homeowner.
NOTE: Prior to the first use of the fireplace and each burn season and periodically during the burn season,
inspect the horizontal termination for debris such as bird nests, leaves, paper or branches. Remove any items
from the surfaces of the termination prior to use. Also be aware of shrubs and plantings that may encroach on
the termination.
Inspecting the burner flame appearance
Periodically inspect the burner and pilot flame. Ensure that the burner flame appearance resembles the flame shown
in Figure 38 on Page 39 and as described in Flame Appearance and Sooting on Page 38. Any necessary
burner flame adjustments must be performed by qualified personnel only (Page 38). Refer to Page 37 for more
information about the pilot flame appearance. Contact a qualified service technician at once if any abnormal condition
is observed.
Cleaning the glass door and firebox
Do not use abrasive cleaners on glass. Never clean the glass when it is hot.
CAUTION
Clean the glass and firebox during the Burn-in Period, and then only when necessary and when the fireplace is cool.
Wipe the surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch
the surface. Periodically, remove any build-up caused by the following:
s During start-up, it is normal for condensation to form on the inside of the glass (this condensation and fog will
usually disappear in a few minutes). The moisture can cause lint, dust and other airborne particles to cling to the
glass surface.
s Initial curing of the high temperature paint and burning off of lubricants used in the manufacturing process may
result in a film on the glass.
s A white coating may form on the glass as a result of impurities and minerals in the fuel.
Clean the glass two or three times each heating season, depending on the circumstances present. The following
cleaning solutions are approved for use:
s Non-ammonia based glass cleaner
58
s 50/50 mixture of white vinegar / water
s Gas fireplace/stove glass cleaner
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Inspecting the glass gasket
Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities,
and seated firmly.
Cleaning the control compartment
Keep the control compartment clean by vacuuming or brushing it out at least twice a year. More frequent cleaning
may be required due to excessive lint from carpeting, bedding material, etcetera. It is imperative that control
compartments, burners and circulating air passageways of the appliance be kept clean.
Touching up paint in small areas
Only use an approved paint kit for any touch-ups. Paint is available at your local IHP dealer. Never attempt to paint a
hot fireplace. Do not attempt to repaint the fireplace until the finish is completely cured (Burn-in Period on Page 52). If
the surface becomes stained or marred, it may be lightly sanded and touched up.
Glass Media
Removing and cleaning the glass media
Risk of personal injury. Allow the media to completely cool before handling.
Use a clean, dry, empty shop vac to remove glass media. Wash the media in warm, soapy water. Rinse and dry
before reinstalling.
Operation
900079-00, 02/2014
CAUTION
Reinstalling the glass media
Carefully follow the placement instructions (Page 55). This will ensure a proper flame and safe combustion.
NOTE: Improper positioning of media can create carbon build-up and will alter the performance of the fireplace.
Replacing the media
If the media needs replacement, use only the proper replacement media from manufacturer (Page 65).
Cleaning the burner
Carefully remove the media. Vacuum out any foreign matter on the burner (e.g., lint, carbon, etc.). Ensure the burner
ports are free of debris.
NOTE: Improper positioning of media can create carbon build-up and will alter the performance of the fireplace.
Inspecting the wiring
Refer to the wiring diagram (Figure 31).
When servicing controls, label all wires prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Au moment de l’entretien des commandes, étiquetez tous les fils avant de les débrancher.
Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
CAUTION
ATTENTION
Inspect and clean all wire connections. Ensure that there is no wire melting or damage. The inspection
should include:
s Terminals at the valve
s ON/OFF switch
59
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
Operation
MAINTENANCE SCHEDULE
See the tables below for detailed information about required maintenance, both regular and annual.
Tabl e 31: Maintenance Performed Annually—Before the Burning Season
Maintenance TaskPerformed ByProcedure
Inspecting/Cleaning Burner, Panels, and
Controls
Checking Flame Patterns and
Flame Height
Inspecting/Cleaning Pilot and BurnerQualified Service TechnicianRemove any surface build-up on pilot and
Checking Vent SystemQualified Service TechnicianRemove baffle, inspect the vent system at
Fireplace InspectionQualified Service TechnicianPerform the appropriate fireplace inspection
Replacing BatteriesHomeowner/Qualified Services TechnicianFor electronic gas valve models:
Qualified Service TechnicianInspect valve and ensure it is properly
operating. Check piping for leaks. Vacuum
the control compartment and burner area.
Qualified Service TechnicianVerify the flame pattern and height displayed
by the fireplace (Figure 38). Flames must not
touch the or fireplace walls or ceiling.
burner assembly. Wipe the pilot nozzles,
igniter/flame rod and hood. Ensure the pilot
flame engulfs the flame sensor.
the top and at the base (within the firebox)
for signs of blockage or obstruction. Look
for any signs of dislocation of the vent
components.
procedure detailed in this manual
(Page 37).
Replace the batteries in the battery holder.
Tabl e 32: Maintenance Performed Periodically—After the Burning Season
Maintenance TaskPerformed ByProcedure
Cleaning Firebox InteriorHomeownerCarefully remove glass media (Page 59).
Vacuum out interior of the firebox. Clean
firebox walls. Replace removed items as
detailed in this manual.
Check Flame Patterns and Flame HeightHomeownerVerify the flame pattern and height displayed
by the fireplace (Figure 38).
Checking Vent SystemHomeownerInspect the vent system at the top and at
the base (within the firebox) for signs of
blockage or obstruction. Look for any signs
of dislocation of the vent components.
Cleaning Glass DoorHomeownerClean as necessary following the directions
provided in this manual (Page 58). Do not
touch or attempt to clean the glass while hot.
60
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
OPTIONAL ACCESSORY COMPONENTS
Surround Kits
Surround kits should be used for a finished appearance.
The FBK-100 blower provides constant velocity forced air circulation.
Tabl e 34: Forced Air Kits
Operation
900079-00, 02/2014
CatalogModelDescription
80L84FBK-100Blower, Standard (single speed)
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the fireplace black painted surfaces may be accomplished with the
touch-up paint kit.
Tabl e 35: Touch -U p Pa in t Kit
Termination Guard Kits
The vent termination guards may be used to cover the vent termination on the exterior of the home to minimize
exposure to the hot surface of the termination.
Tabl e 36: Termi na ti on G ua rd Ki ts
Termination
Shroud
(fits H1968)
Termination
and H1968)
Glass Media Kits
Deluxe
Guard
(fits 94L10
Catalog No.Model No.
90L73FTPK-B
CatalogModelDescription
Square
Termination
Guard
(fits 94L10
and H1968)
H58204.5HTSKTermination Shroud
87L02SV4.5HGSTermination Guard, Deluxe
17M52SV4.5HGS-1Termination Guard, Square
Tabl e 37: Glass Media
CatalogModelDescription
H8412CRSHGL-RBLKBag of Glass Media, Reflective Black
H8424CRSHGL-RBLUBag of Glass Media, Reflective Blue
H8413CRSHGL-PBag of Glass Media, Platinum
H8538CRSHGL-GFBag of Glass Media, Goldfinger
H8539CRSHGL-CBag of Glass Media, Copper
61
Innovative Hearth Products
ElectronicGasControl
Valve-SIT
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result,
causing property damage, personal injury, or loss of life.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
sDo not try to light any appliance.
sDo not touch any electric switch; do not use any phone in your building.
sImmediately call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions.
sIf you cannot reach your gas supplier, call the fire department.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Read this manual including the remote control system section.
3. Slide the switch on the receiver to OFF.
4. Press ON/OFF button on remote control transmitter to OFF.
5. Turn OFF all electric power to the appliance.
NOTE: The control has a battery backup (remove batteries).
NOTE: This appliance is equipped with an ignition device which automatically
lights the pilot. Do not try to light the pilot by hand.
E. Wait five (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow B in FOR YOUR SAFETY READ BEFORE LIGHTING. If
you do not smell gas, go to the next step.
6. Turn ON all electric power to the appliance.
NOTE: The control has a battery backup (install batteries).
7. Slide the switch on the receiver to REMOTE.
8. Press ON/OFF button on remote control transmitter to ON.
9. If applicable, set thermostat on remote control transmitter to desired setting.
10. If the appliance will not operate, follow the instructions TO TURN
OFF GAS TO APPLIANCE and call your service technician or
gas supplier.
Operation
900079-00, 02/2014
C. If any portion of this appliance does not operate as the instructions
indicate, do not try to repair it, call a qualified service technician.
Do not use tools. Force or attempted repair may result in a fire
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
Electronic Gas
Control Valve
Wall Switch
Receiver
On
Remote
Off
PRG
Electronic Pilot
Assembly
Remote Control
Transmitter
ON/OFF Key
THERMOSTAT
Key
1. Slide the switch on the receiver to OFF.
2. Press ON/OFF button on remote control transmitter to OFF.
62
TO TURN OFF GAS TO APPLIANCE
3. Turn OFF all electric power to the appliance if service is to
be performed.
NOTE: The control may have a battery backup (remove batteries, if installed).
4. Close the main line gas shutoff valve.
WARNING
Hot glass will cause burns.
Do not touch glass until cooled.
Never allow children to touch glass.
Innovative Hearth Products
ElectronicGasControl
Valve-SIT
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
POUR PLUS DE SÉCURITÉ, LIRE AVANT DE METTRE EN MARCHE
AVERTISSEMENT : Quiconque ne respecte pas à la lettre les instructions dans la présente
notice risque de déclencher un incendie ou une explosion entraînant des dommages, des
blessures ou la mort.
Cet appareil est muni d’un dispositif d’allumage qui allume
A.
automatiquement la veilleuse. Ne tentez pas d’allumer la
veilleuse manuellement.
B. AVANT DE FAIRE FONCTIONNER, reniflez tout autour de l’appareil
pour déceler une odeur de gaz. Reniflez près du plancher, car
certains gaz sont plus lourds que l’air et peuvent s’accumuler au
niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
sNe pas tenter d’allumer d’appareil.
sNe touchez à aucun interrupteur; ne pas vous servir des téléphones
se trouvant dans le bâtiment.
INSTRUCTIONS DE MISE EN MARCHE
1. ARRÊTEZ ! Lisez les avertissements de sécurité à l’endos de
cette étiquette.
2. Lisez le manuel d’utilisation et d’entretien incluant la section
« Système de télécommande » (si applicable).
3. Placez l’interrupteur mural ou “on/off” en position OFF.
4. Coupez l’alimentation électrique de l’appareil.
Remarqué : Le contrôleur peut avoir une batterie de secours (retirer les
batteries au besoin).
5. Cet appareil est muni d’un dispositif d’allumage qui allume
automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse
manuellement.
6. Attendre cinq (5) minutes** pour laisser échapper tout le gaz.
Reniflez tout autour de l’appareil, y compris près du plancher,
pour déceler une odeur de gaz. Si vous sentez une odeur de gaz,
ARRÊTEZ ! Passez à l’étape B des instructions de sécurité sur
la portion supérieure (à gauche) de cette étiquette. S’il n’y a pas
d’odeur de gaz, passez à l’étape suivante.
7. Mettez l’appareil sous tension.
Remarqué : Le contrôleur peut avoir une batterie de secours (installer les
batteries au besoin).
8. Placez l’interrupteur du récepteur en position REMOTE (ou
l’interrupteur mural en position ON).
9. Si applicable) Appuyez sur le bouton “ON/OFF” pour
sélectionner ON.
Operation
900079-00, 02/2014
sAppelez immédiatement votre fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
sSi vous ne pouvez rejoindre le fournisseur, appelez le service
des incendies.
C. Si un élément de cette unité ne fonctionne pas tel que décrit dans
les instructions, n’essayez pas de le réparer, appelez un technicien
qualifié. N’utilisez-pas d’outils. Le fait de forcer la manette ou de la
réparer peut déclencher une explosion ou un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même
partiellement. Faites inspecter l’appareil par un technicien
qualifié et remplacez toute partie du système de contrôle et toute
commande qui ont été plongés dans l’eau.
10. (Si applicable) Ajustez le thermostat sur la télécommande à
l’ajustement désiré.
11. Si l’appareil ne se met pas en marche, suivez les instructions
intitulées «Comment couper l’admission de gaz de l’appareil » et
appelez un technicien qualifié ou le fournisseur de gaz.
Valve électronique
Récepteur
On
Remote
Off
PRG
Module de
veilleuse
électronique
Télécommande
ON/OFF Bouton
THERMOSTAT
Bouton
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. Placez l’interrupteur mural ou “on/off” en position OFF.
2. (Si applicable) Sélectionnez OFF sur le récepteur.
3. Coupez l’alimentation électrique de l’appareil s’il faut procéder à
l’entretien.
Remarqué : Le contrôleur peut avoir une batterie de secours (retirer les
batteries au besoin).
4. Fermer la valve de gaz principale.
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D’Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE.
63
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
TROUBLESHOOTING
Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following
troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the
instructions provided with the remote.
Detailed valve system troubleshooting should only be performed by a qualified service technician.
Tabl e 38: Troub le sh oo ti ng Elec tr on ic S ys te ms
1. Nothing happens
when the fireplace is
turned ON/OFF.
2. The main burner
does not light and the
igniter is sparking.
3. The main Burner
comes on but then
goes out.
4. Soot is present on
the glass.
5. Poor flame and/or
blue flame.
*The unit may have multiple gas supply shutoffs (the main gas supply valve in the house, the gas supply valve in the fireplace control compartment, and/or an
additional shutoff valve near the fireplace).
a. Remote is not functioning properly.Check that the wall switch plate is set to REMOTE.
Operate the fireplace from the wall plate switch.
Replace remote and/or wall switch batteries.
b. Gas is not reaching the fireplace.Check the gas supply and gas shutoff valves. *
c. Unit is not receiving power.Check/replace backup batteries behind the wall plate.
Replace unit battery backup.
Check building circuit breakers to ensure power is ON
to the fireplace.
a. Gas is not reaching the fireplace.Check the gas supply and gas shutoff valves.
b. Loose wires to the valve.Check control compartment for any obviously loose
wiring (call a service technician, if necessary).
c. Loose wires to ignition module.Check control compartment for any obviously loose
wiring (call a service technician, if necessary).
d. Air in the gas line.Purge gas line of air (call a service technician if
required).
e. Unit is not receiving power.Replace unit battery backup.
a. Fireplace has not established proper draft. Switch CPI/IPI switch to pilot ON mode; wait two (2)
minutes; then relight.
b. Gas is not reaching the fireplace.Check the gas supply and gas shutoff valves.
c. Loose wires to the valve or ignition
module.
Check control compartment for any obviously loose
wiring (call a service technician, if necessary).
d. Pilot flame is not engulfing the sensor.Call a service technician.
e. Obstructed vent system.Call a service technician.
a. Initial fireplace operation.A white film may develop on the glass during the first
few fires as part of the burn-in process.
The first few times you use the fireplace, clean
the glass after each use (AFTER THE GLASS HAS
COMPLETELY COOLED); otherwise, the white film will
bake onto the glass and become difficult to remove.
See glass cleaning instructions in the MAINTENANCE
section of this manual.
b. Improper vent restrictor setting.Open the air shutter by adjusting the air shutter
adjustment lever according to the instructions in
this manual.
c. Improper air shutter opening.Open the air shutter by pushing in the rod.
d. Excessive flame impingement on panels
Properly position the media.
and fireplace ceiling.
a. Door seal is not properly aligned, causing
gaps and air leaks.
Remove and realign the door so the gasket seal is
fully engaged around the door frame.
Operation
64
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
900079-00, 02/2014
REPLACEMENT PARTS
Contact an IHP dealer to obtain any of these parts. Contact IHP for the phone number of your nearest IHP dealer.
Tabl e 39: Installer Replacement Parts
Description
1 Control Compartment Access DoorH84351H84351
2 Control Compartment Access Door GasketH84361H84361
3 Gas Train Assembly, Natural GasH87961H87951
4 Gas Train Assembly, PropaneH87981H87971
5 Orifice, #43 (0.089”)99K7501199K75011
6 Orifice, #55 (0.052”)19L52119L521
7 Orifice, #37 (0.104”)24M10124M101
8 Orifice, 0.063”LB-37G001LB-37G001
9 Burner AssemblyH87941H84321
10 Wall Switch Receiver KitH85641H85641
11 DFC Wire HarnessH86011H86011
12 Ground WireH72781H72781
13 DFC Ignition BoardH72721H72721
14 NG Gas ValveH85621H85621
15 Propane Gas ValveH85941H85941
16 NG Pilot AssemblyH72681H72681
17 Propane Pilot AssemblyH72691H72691
18 Glass Door LatchH84331H84331
19 Flex Gas Connector Assembly93L32193L321
20 Orifice ConnectorH78471H78471
21 CPI/IPI Switch27K30127K301
22 DFC Wire Harness AssemblyH86011H86011
23 Non-combustible Board KitH87881H87891
24 Back Panel, Black PorcelainH88001 H88041
25 Side Panel RH, Black PorcelainH88011H88051
26 Side Panel LH, Black PorcelainH88021H88061
27 Power TransformerH80061H80061
28 Floor Section, RearH87901H87911
29 Floor Section, FrontH87921H87931
30 Battery Holder (for backup batteries)H88031H88031
Catalog NumberQtyCatalog NumberQty
42”54”
Operation
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et
ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
Never use substitute materials. Use of non-approved parts can result in poor performance, safety hazards, and may void the warranty.
WARNING
AVERTISSEMENT
WARNING
65
Innovative Hearth Products
25-1675 DB REV 004
25-1675 DB REV 004
Power
120V
Out
Fan
Aux
Out
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
Figure 58: Replacement Parts
12
9
14
15
16
17
Operation
900079-00, 02/2014
11
18
25-1675 DB REV 004
32
33
34
Tabl e 40: Homeowner Replacement Parts
Description
Catalog NumberQtyCatalog NumberQty
31 Remote Control Transmitter KitH85631H85631
32 Glass DoorH87991H84311
33 Top B af fleH87871H85831
34 Blower Assembly FBK-100 (optional)80L84180L841
42”54”
66
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
WARRANTY
THE WARRANTY
Innovative Hearth Products (“IHP”) Limited Lifetime Warranty warrants your Astria™ brand gas fireplace (“Product”) to be free from defects in materials and workmanship
at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal
breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Lifetime Warranty
period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not
commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing
labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to
this Limited Lifetime Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six
months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following
the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be
provided. The Product body and firebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from
this Limited Lifetime Warranty. The following do not carry the Limited Lifetime Warranty but are warranted as follows:
Operation
900079-00, 02/2014
Innovative Hearth Products
Astria™ Brand Gas Fireplace
Limited Lifetime Warranty
Burner – Repair or replacement for five years from the date of installation
Gas components & electrical components – Repair or replacement for one year from the date of installation
Gaskets – Repair or replacement for one year from the date of installation
Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing
Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component
Light bulbs & batteries – Replacement for 90 days from the date of installation
Logs – Replacement for five years from the date of installation against thermal breakage only
Optional blowers & remote controls – Repair or replacement for one year from the date of installation
Optional glass doors & optional glass accessories – Repair or replacement for 90 days from the date of installation
Optional surrounds – Stone/Natural Materials: Replacement for one year against cracking or breakage due to thermal stress. Other Materials: Replacement for one
year. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit
Tempered Glass -Replacement for one year from the date of installation
Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse,
or unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to
burn either natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive
temperatures and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided
with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction
conditions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused
by venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any
malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied,
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or
after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a
particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and
provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of
this Limited Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without first obtaining IHP’s prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.
Innovative Hearth Products
Astria™ Sirius Linear Direct-Vent Gas Fireplaces
www.astria.US.com
Record the following important information about your fireplace:
Installation and Operation Instructions
900079-00, 02/2014
Fireplace model number
Fireplace serial number
Date fireplace was Installed
Typ e o f g as fire place use s
Dealer name
P900079-00
Innovative Hearth Products reserves the right to make changes at any time, without notice, in
design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.