
USER’S MANUAL
1000VA/1500VA/2000VA
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important safety instructions. Please follow all instructions carefully during
installation. Read this manual thoroughly before attempting to unpack, install or operate.
CAUTION- To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area, free of conductive contaminants.
CAUTION- Risk of electric shock, do not remove the cover. No user serviceable parts. Refer
servicing to qualified service personnel.
CAUTION- Risk of electric shock, hazardous live parts inside this UPS can be energized from the
battery supply even when the input AC power is disconnected.
CAUTION- Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage
may exist between battery terminals and ground. Test before touching.
NOTICE- The UPS is designed to be for use with computer loads only.
1 Inspection
Inspect the UPS upon
receipt. Notify the carrier
and dealer if there is
damage. The package is
recyclable; save it for reuse
or dispose of it properly.
Inspect accessories:
① Power cable 1PCS
② USER MANUAL
1PCS
2 Choose an installation location
3 Connect the loads
Plug in the AC input cord to the Utility(Make sure the
voltage of Utility matches with the input
voltage window of the UPS)
※Plug the UPS into the wall outlet to charge the UPS for
over 8 hours before using the UPS.
Plug in the loads to output receptacles on the rear panel
of the UPS.
Caution:Do not connect a laser printer to the outlets.
These UPS outlets provide battery power to the
equipment when utility voltage is outside acceptable limits.
4 Connect Modem/ Phone / Network for Surge Protection(only for
the mode with RJ-45)
Connect a single modem/phone line
into surge-protected “IN” outlet on the
back
panel of the UPS unit. Connect from
“OUT” outlet to the computer with another phone
line cable.
5 Connect
Computer
Interface Port
(Optional)
Connect the optional interface
cable to the USB interface
port on the back of the UPS.
Connect to the computer. See
software document for installation instruction.
6 Turn ON/OFF the UPS
Turn on the UPS: Press the UPS
On/OFF Switch for approx. 3 seconds,
then the Buzzer sounds twice, the UPS
will be start-up.
Turn off the UPS: Press the UPS
On/OFF Switch for approx. 3 seconds,
then the Buzzer sounds twice, the UPS
will be shutdown.
7 Cold Start Function
When the UPS is off and there is no
power utility, it's still possible to cold
start the UPS unit to power the loads.
8 Software Download and Installation
Please follow steps below to download and install monitoring software:
1. Go to the website http://www.Ablerex.com
2. Click Emily II software icon and then choose your required OS to down load the software.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software ※Software only for the model with communication port.
GRs - 1000 / 1500 / 2000 - LED
FRONT PANEL(STANDARD)
GRs - 1000/1500/2000 - LCD
FRONT PANEL(OPTION))
Tack switch for
Turn-on/Turn-off
Lit: Line mode
Dim: Abnormal input voltage
and frequency in standby
mode
Flashing: Standby mode
Lit: Battery mode
Flashing: Battery Low
Lit: System malfunction or
abnormal
8.Tack switch for
Turn-on/Turn-off
6.Measurement
Target & Value
1. AC input outlet
2. Fuse
3. Output receptacles
4. RS-232 or USB port (option)
5. Modem/LAN Internet Protection (option)
6. Fan (only for GRs 1500/2000)

Note:Once the battery is disconnected, the loads are not protected
from power outages.
1. Use a cross-type screwdriver to remove five screws on bottom shell
and screws on backplane.If there is a RS232 port,remove the
screws on the port please.
2. Take off the top cover and front panel.
3. 1:Loosen the black wire from the negative (-) terminal and red wire
from the positive (+) terminal. 2:Remove the battery cover.
4. Exchange the new battery for the UPS
5. 1. Put on the battery cover on the battery. 2. Connect the battery leads to the new battery.
Note: Small sparks at the battery connectors are normal during connection.
6. 1:Install the top cover. 2:Install the front panel.
7. Fasten the screws mentioned in step 1.
8. Dispose of the old battery properly at an appropriate recycling facility.
Should the UPS fail to function correctly we
recommend you perform the following tests
before calling the service.
Check step:
Step 1: Is the main switch in the “ON”
position?
Step 2: Is the UPS plugged into the mains
power supply?
Step 3: Does the power supply fall within
specified unit values?
Step 4: Has the fuse gone in the mains plug?
Step 5: Is the UPS overload?
Step 6: Is the battery flat or defective?
No LED display on the front
panel.
Charge the UPS at least 6 hours.
Replace the battery with the same type of battery.
The UPS is not turned on.
Press the power switch again to turn on the UPS.
Alarm continuously sounds
when the Utility is normal.
Remove some loads first. Before reconnecting equipment, please
verify that the load matches the UPS capability specified in the specs.
When power fails, back up
time is shorten.
Remove some critical load.
Battery voltage is too low.
Charge the UPS at least6 hours.
Battery defect. It might be due to high
temperature operation environment, or improper
operation to battery.
Replace the battery with the same type of battery.
The Utility is normal, but LED
is flashing.
Reconnect the power cord properly.
GRs 1000 / 1500 / 2000 SPECIFICATIONS
4-6 hours recover to 90% capacity
Packaging Dimension(DxWxH,
mm)
0-90 % RH @ 0-40 C (non-condensing)