AST AST53EN Datasheet

Page 1
TM
Differential Pressure Transducer
AST5300 AST53ED AST53EN
The AST5300 offers low differential pressure measurement ranges in high line pressure applications with excellent burst pressure capabilities. The
AST5300 has no oil lled cavities and no internal o-rings to fail, making it
ideal for food and beverage, oil & gas, pharmaceuticals, semiconductor industries and cold ambients.
Environmental Data
Temperature
Operating -40 to 85°C (-40° to 185°F)
Storage -55 to 120°C (-67° to 248°F)
Media -55 to 125°C (-67° to 257°F)
Compensated Range -5 to 65°C (23° to 149°F)
<±1.0% of FS (10 PSID)
Total Thermal Error
<±1.5% of FS (5 to 9 PSID)
<±1.0% of FS (1 PSID)
Benefits
ABS (American Bureau of Shipping) Approved
Applications
Flow measurement
Oil free - no containment issues
Wide operating temperature
Wide range of liquid & gas compatibility
High Purity Gases
Tank level monitoring
Compact size
Ballast measurement
Explosion Proof Rated (AST53ED)
CSA30 Class I Zone 1 Group IIC
Class I Division 1 Groups A, B, C, D
Filtration
Cryogenics
Class II Division 1 Groups E, F and G
Class III Division 1
Non-Incendive Rated (AST53EN)
CSA213 Class I Division 2 Groups A, B, C, D
ANSI/ISA 12.27.01 Single Seal Device
Performance @ 25°C (77°F) [% of FS]
Line Pressure (Common) 1,500 PSI, maximum (see page 2)
Burst Pressure 5,000 PSI, minimum
Proof Pressure (5-10 PSID) 500 PSI
Proof Pressure (1 PSID)
Linearity <± 0.2% BFSL
Zero Offset <± 1.0%
Span Tolerance <± 0.5%
Electrical Data
Output 0-5V, 1-5V Three Wire 4-20mA 0.5-4.5V Ratiometric
Excitation 10-28VDC 10-28VDC 5VDC, reg
Current Consumption: <10mA - <10mA
Output Load: 10k Ohms 0-800 Ohms 10k Ohms
EMI / RFI Protection 100V/m 100V/m 100V/m
Reverse Polarity Protection Yes Yes Yes
American Sensor Technologies 450 Clark Dr., Mt. Olive, NJ 07828 phone (973) 448-1901 fax (973) 448-1905 email: info@astsensors.com
Page 2
TM
Ordering Information
AST53 ED 0010 P 4DP W 0008
Series Type
Approval
ED= Explosion proof EN= Non-Incendive 00= OEM
Mounting / Pressure Connection
DP= Threaded Fittings (1/4” FNPT)
Differential Pressure
0001= 1 PSI 0008= 8 PSI 0005= 5 PSI 0009= 9 PSI 0006= 6 PSI 0010= 10 PSI 0007= 7 PSI
Pressure Unit
P= PSI
Output
1= 0.5-4.5V ratiometric 2= 0-5V (3-wire) 3= 1-5V 4= 4-20mA
Electrical Connection (see table)
Subject to Approval Type Selected
Wetted Material
8= 316L & Inconel x750
Options
00= No Special Options
Electrical Connection Table 00 ED EN
I DIN 43650-A
M Conduit, 4ft.
N Conduit, 6ft.
R 6-Pin Bendix PT06
T Conduit, 18AWG, 24 in
U Conduit, 18AWG, 48 in
W Conduit, 18AWG, 2m
Y M12 4-Pin
LINE PRESSURE
The line pressure specication is the maximum pressure the AST5300
can see without damage. Any pressure applied over the listed number will likely damage the transducer and will, at minimum, cause a perma­nent zero shift. Line pressure should be applied evenly to both ports during start up and shut down. [ A Line pressure of 500 psi or less can be applied to one pressure port with the other port at 0psi and will not cause a zero shift of the output. Pressure above 500 PSI to one side may cause a temporary zero shift. ]
To recover from a zero shift caused by negative over-pressure to “L” (low / downstream process connection) within the listed limits, apply a positive over-pressure “H” (high / upstream process connection) to
1,450 PSI for a duration of ve minutes. Remove the over-pressure
and check the zero with no pressure applied. If the zero has not recovered, repeat the positive over-pressure and recheck zero. If it has not recovered after the second try, the zero has been permanently shifted. Contact the factory.
* *
* *
* *
*
*
*
*
*
www.astsensors.com
Dimensional Data
Process Connections
DP = 1/4” FNPT
H = high / upstream pressure L = low / downstream pressure
© 2014 American Sensor Technologies Inc. AST5300 03/07/2014.
All specications subject to change without notice.
Loading...