AST AST53EN Datasheet

TM
Differential Pressure Transducer
AST5300 AST53ED AST53EN
The AST5300 offers low differential pressure measurement ranges in high line pressure applications with excellent burst pressure capabilities. The
AST5300 has no oil lled cavities and no internal o-rings to fail, making it
ideal for food and beverage, oil & gas, pharmaceuticals, semiconductor industries and cold ambients.
Environmental Data
Temperature
Operating -40 to 85°C (-40° to 185°F)
Storage -55 to 120°C (-67° to 248°F)
Media -55 to 125°C (-67° to 257°F)
Compensated Range -5 to 65°C (23° to 149°F)
<±1.0% of FS (10 PSID)
Total Thermal Error
<±1.5% of FS (5 to 9 PSID)
<±1.0% of FS (1 PSID)
Benefits
ABS (American Bureau of Shipping) Approved
Applications
Flow measurement
Oil free - no containment issues
Wide operating temperature
Wide range of liquid & gas compatibility
High Purity Gases
Tank level monitoring
Compact size
Ballast measurement
Explosion Proof Rated (AST53ED)
CSA30 Class I Zone 1 Group IIC
Class I Division 1 Groups A, B, C, D
Filtration
Cryogenics
Class II Division 1 Groups E, F and G
Class III Division 1
Non-Incendive Rated (AST53EN)
CSA213 Class I Division 2 Groups A, B, C, D
ANSI/ISA 12.27.01 Single Seal Device
Performance @ 25°C (77°F) [% of FS]
Line Pressure (Common) 1,500 PSI, maximum (see page 2)
Burst Pressure 5,000 PSI, minimum
Proof Pressure (5-10 PSID) 500 PSI
Proof Pressure (1 PSID)
Linearity <± 0.2% BFSL
Zero Offset <± 1.0%
Span Tolerance <± 0.5%
Electrical Data
Output 0-5V, 1-5V Three Wire 4-20mA 0.5-4.5V Ratiometric
Excitation 10-28VDC 10-28VDC 5VDC, reg
Current Consumption: <10mA - <10mA
Output Load: 10k Ohms 0-800 Ohms 10k Ohms
EMI / RFI Protection 100V/m 100V/m 100V/m
Reverse Polarity Protection Yes Yes Yes
American Sensor Technologies 450 Clark Dr., Mt. Olive, NJ 07828 phone (973) 448-1901 fax (973) 448-1905 email: info@astsensors.com
TM
Ordering Information
AST53 ED 0010 P 4DP W 0008
Series Type
Approval
ED= Explosion proof EN= Non-Incendive 00= OEM
Mounting / Pressure Connection
DP= Threaded Fittings (1/4” FNPT)
Differential Pressure
0001= 1 PSI 0008= 8 PSI 0005= 5 PSI 0009= 9 PSI 0006= 6 PSI 0010= 10 PSI 0007= 7 PSI
Pressure Unit
P= PSI
Output
1= 0.5-4.5V ratiometric 2= 0-5V (3-wire) 3= 1-5V 4= 4-20mA
Electrical Connection (see table)
Subject to Approval Type Selected
Wetted Material
8= 316L & Inconel x750
Options
00= No Special Options
Electrical Connection Table 00 ED EN
I DIN 43650-A
M Conduit, 4ft.
N Conduit, 6ft.
R 6-Pin Bendix PT06
T Conduit, 18AWG, 24 in
U Conduit, 18AWG, 48 in
W Conduit, 18AWG, 2m
Y M12 4-Pin
LINE PRESSURE
The line pressure specication is the maximum pressure the AST5300
can see without damage. Any pressure applied over the listed number will likely damage the transducer and will, at minimum, cause a perma­nent zero shift. Line pressure should be applied evenly to both ports during start up and shut down. [ A Line pressure of 500 psi or less can be applied to one pressure port with the other port at 0psi and will not cause a zero shift of the output. Pressure above 500 PSI to one side may cause a temporary zero shift. ]
To recover from a zero shift caused by negative over-pressure to “L” (low / downstream process connection) within the listed limits, apply a positive over-pressure “H” (high / upstream process connection) to
1,450 PSI for a duration of ve minutes. Remove the over-pressure
and check the zero with no pressure applied. If the zero has not recovered, repeat the positive over-pressure and recheck zero. If it has not recovered after the second try, the zero has been permanently shifted. Contact the factory.
* *
* *
* *
*
*
*
*
*
www.astsensors.com
Dimensional Data
Process Connections
DP = 1/4” FNPT
H = high / upstream pressure L = low / downstream pressure
© 2014 American Sensor Technologies Inc. AST5300 03/07/2014.
All specications subject to change without notice.
Loading...