AST AST46PT Datasheet

TM
Explosion-Proof
AST46PT Pressure / Temperature Transmitter
Constructed with a simple-yet-rugged design, the AST4600 Explosionproof Pressure Transducer/Transmitter stands up to a variety of applications where price and performance are critical.
Factory Sealed Gauge Pressure Transducer
Pressures from 100 to 20,000 PSI• CSA approved for use in hazardous areas including:•
UL1203/FM3615 Class I Zone 1 Group IIC Class I Div 1 Groups A, B, C, D Explosionproof Class II Div 1 Groups E, F, G Dust Ignition-proof
Vented Gauge Pressure Transducer
Pressures from 1 to 1,000 PSI Gauge• CSA approved for use in hazardous areas including:•
Class I Zone 1 Group IIC Class I Div 1 Groups A, B, C, D Explosionproof
Applications
Well Optimization
Oil and Gas Pipelines Drilling Platforms Marine & Offshore CNG / Hydrogen Fill Stations Paint Booths Remote Telemetry Unit Cold Climate Drilling & Mining Panel Instrumentation
Environmental Data
Temperature
Operating Ambient -40 to 85°C (-40 to 185°F)
Operating Media -55 to 125°C (-65 to 250°F)
Storage -55 to 105°C (-67 to 221°F)
Thermal Limits
TC Zero: <±0.5% FS TC Span: <±0.5% FS
Other
Shock EN 60068-2-27
Vibration EN 60068-2-6, 60068-2-64, and IEC 68-2-32
EMI/RFI Protection: Yes
Rating: IP-65 (vented), IP-66(factory sealed)
Benefits
ANSI/ISA-12.27.01.2003 Certied “Single Seal”
(no secondary seal required)
ABS (American Bureau of Shipping) Approved
ASIC Compensation Superb Temperature Performance Wide Operating Temperature Excellent Accuracy High Proof and Burst Pressure Available in Exotic Alloys (Consult Factory for
Inconel 718 or Hastelloy C276)
Performance @ 25°C (77°F)
Accuracy* <±0.1% BFSL
Stability (1 year) ±0.1% FS, typical
Over Range Protection
Burst Pressure 5X or 50,000 PSI (whichever is less)
Pressure Cycles > 100 Million
* Accuracy includes non-linearity, hysteresis & non-repeatability, + For higher proof pressures, contact factory
+
2X Rated Pressure
Electrical Data
Output 4-20mA 0-5V, 1-5V, 1-6V 0-10V, 1-10V 0.5-4.5V Ratiometric
Excitation 10-28VDC 10-28VDC 15-30VDC 5VDC, Regulated
Current Consumption - <10mA <10mA <10mA
Sampling Rate 400Hz 400Hz 400Hz 400Hz
Output Noise <1mV, RMS <1mV, RMS <1mV, RMS <1mV, RMS
Zero Offset <±0.5% FS <±0.5% FS <±0.5% FS <±0.5% FS
Span Tolerance <±0.5% FS <±0.5% FS <±0.5% FS <±0.5% FS
Output Load 0-800 Ohms@10-28VDC 5k Ohms, min. 5k Ohms, min. 5k Ohms, min.
Reverse Polarity Protection Yes Yes Yes Yes
American Sensor Technologies 450 Clark Dr., Mt. Olive, NJ 07828 phone (973) 448-1901 fax (973) 448-1905 email: info@astsensors.com
TM
Ordering Information
AST46PT A 0500 P 3 1
Series Type
Temperature Output
1= -40 to 85°C (-40 to 185°F) 2= -40 to 125°C (-40 to 257°F) 3= 0 to 70°C (32 to 158°F) 4= -55 to 125°C (-67 to 250°F) 5= -18 to 93°C (0-200°F)
Process Connection*
A= 1/4" NPT Male (up to 10,000 PSI) I= 1/4" NPT Female (up to 15,000 PSI) P= 1/2" NPT Male (up to 15,000 PSI) W= F250C Female Autoclave (10,000 to 20,000 PSI)
* for other ports contact factory, "W" not available in 316L
Pressure Range
G= Gauge Pressure** V= Gauge Pressure (Vacuum Calibrated)** 0= Sealed Gauge up to 9,999 PSI 1= Sealed Gauge up 10,000 to 19,999 PSI 2= Sealed Gauge 20,000 PSI
** Not suitable for Class II
Insert Pressure Code
Pressure Unit
B= Bar K= kg/cm
Outputs
1= 0.5-4.5V ratiometric 2= 0-5V 3= 1-5V
Electrical
T= 2ft. 18 AWG wires U = 4 f t . 1 8 A W G w i r e s W= 2 Meter 18 AWG wires
1
2
P= PSI
4= 4-20mA 5= 0-10V 6= 1-6V G= 1-10V
TG
H
000
-Z
Wetted Material
0= 17-4PH 1= 316L 2= Inconel 718
+
Consult factory on availability
Failure State
H= High L= Low N= None
Options
000= No Options
Approval
-Z= Add “-Z” for CRN Registered to ANSI/ASME B31.3. Contact factory for material, pressure, and process connection options.
Pressure Ranges Wiring
Pressure Ranges
0-1
0-2.5
++
G 0001
G 0069 0-200 0 0200
0-5 G 0005 0-500 0 0500
++
0-7.5
G 0208 0-1,000 0 1000
0-10 G 0010 0-1,500 0 1500
0-15 G 0015 0-2,500 0 2500
0-25 G 0025 0-3,000 0 3000
0-50 G 0050 0-5,000 0 5000
Pressure PSI
0-100 G 0100 0-7,500 0 7500
0-200 G 0200 0-10,000 1 0000
0-500 G 0500 0-15,000 1 5000
Pressure Code Vented
0-1,000 G 1000 0-20,000 2 0000
++
2.5 and 7.5 PSI units must be ordered in inches of H2O
+
4= Hastelloy C276
0-100
Pressure PSI
+
0 0100
Power Connections Output Connections
Output
Voltage +V Supply -V Supply Pressure Temp.
4-20mA +Pressure -Pressure -Temp. +Temp.
For U.S. installations, sensor case ground (green wire) must be bonded to ground according to Article 501 & 505 of the NEC.
Pressure Code Factory Sealed
Red Black White Blue
Green Length
Case
Case
4.3"
4.68"
4.8"
5.18"
Ground
Ground
www.astsensors.com
© 2014 American Sensor Technologies Inc. AST46PT 01/30/2014.
All specications subject to change without notice.