AST AST46DS Datasheet

TM
Explosion-Proof Pressure Transducer / Transmitter with Display
AST46DS CSA Certified: Class I & II Division 1 & 2 | Class III
AST46DS explosion proof pressure transducers features the latest advances in transducer technology. With a power supply as low as an 8VDC and low current consumption, the AST46DS can operate in remote areas with minimal power. The
re-zeroing function, allows for eld calibration in a safe environment to further enhance
well site or system readings. Pressure ranges are available up to 20,000 PSI; these explosion-proof pressure transducers and transmitters are designed for all common oil and gas pressures from shallow to deep wells.
Explosion Proof: Class I & II Division 1 / 2 Groups A, B, C, D, E, F, G
Class III Division 1 & 2
ANSI/ISA 12.27.01-2003 Single Seal Approved
ABS (American Bureau of Shipping) Approved
Display Units: PSI | Bar | kpa | Mpa | kg/cm
2
| in WC | Volts | mA
Benefits
Low current consumption voltage output Re-zero push-button functionality Display pressure units or output signal
Environmental Data
Operating -40 to 85°C (-40 to 185°F)
Display Operating -30 to 80°C (-22 to 176°F)
Storage -55 to 105°C (-67 to 221°F)
Temperature
Compensated Range 0 to 55°C (30 to 130°F)
TC Zero <±1.0% of FS
Limits
Thermal
TC Span <±1.0% of FS
Shock 100G, 11 msec, 1/2 sine
Vibration 10G peak, 20 to 2000 Hz.
EMI/RFI Protection: Yes
Enclosure Rating: Suitable for Outdoor Use; Type 4X Rated
Other
Pollution Degree 2 (interior of enclosure)
Measurement (Installation) Category
Altitude 2000m
I
Accurate, repeatable sensor technology Rugged design withstands harsh outdoor
environments
Available in exotic alloys
High quality, NEMA 4X case and nish
withstands salt spray and outdoor environments
Performance @ 25°C (77°F)
Accuracy* < ±0.25% BFSL
Stability (1 year) ±0.25% FS, typical
Over Range Protection 2X Rated Pressure
Burst Pressure 5X Rated Pressure or 45,000 PSI, whichever is less
Electrical Data
Output 4-20mA 1-5VDC
Excitation 8-28VDC 8-28VDC
Output Impedance >10k Ohms <100 Ohms, Nominal
Current Consumption: 25mA, typical 2mA, typical
Bandwidth (-3dB): DC to 1kHz (-3dB): DC to 1kHz
Output Noise: - <2mV RMS
Zero Offset: <± 0.5% of FS <± 0.5% of FS
Span Tolerance: <± 1.0% of FS <± 1.0% of FS
Output Load: 0-800 Ohms@8-28VDC 5k Ohms, Min.
Reverse Polarity Protection Yes Yes
Applications
SCADA systems
Wellhead systems Compressor systems and
stations
Pipeline instrumentation
Power generation equipment
Offshore platforms
Oil and gas pressure
monitoring
Test systems
American Sensor Technologies 450 Clark Dr., Mt. Olive, NJ 07828 phone (973) 448-1901 fax (973) 448-1905 email: info@astsensors.com
TM
Ordering Information
AST46DS G 0500 3 1 0002P
Series Type
Process Connection
A= 1/4” NPT Male I= 1/4” NPT Female P= 1/2” NPT Male W= F250C Autoclave Female
Pressure Reference
G= Vented* (0-499 PSI) V= Vented - Vacuum Calibrated* (-14.7 up to 500 PSI) 0= Non-Vented (0-500 to 9,999 PSI) 1= Non-Vented (10,000 to 19,999 PSI) 2= Non-Vented (20,000 PSI)
Pressure Measurement
Insert - 4 digit pressure code
Pressure Unit
B= Bar K= kg/cm
Outputs
3= 1-5V (3 Wire + Case Connection) 4= 4-20mA (Loop Powered + Case Connection)
Electrical
2= Terminal Blocks (1/2” FNPT Conduit Connections - standard)
2
P= PSI H=Inches H2O
P
-Z
Sensor Material
0= 17-4PH 1= 316L**
Options
Options
000= No Options
000= No Options
Approval
-Z= Add “-Z” for CRN Registered to ANSI/ASME B31.3. Contact factory for material, pressure, and process connection options.
*Not suitable for Class II; Sensing element corrects for barometric pressure through base sensor assembly. **NACE MR0175/ISO 15156 compatible material
PSIG Measurement
+
2.5 and 7.5 PSI Sensor must be ordered in inches of H2O. Pressures from 0-1 to 0-15PSI
are not suitable for hydrogen. 316L and Hastelloy C276 are the only material options.
www.astsensors.com
2= Inconel 718 (contact factory for availability)** 4= Hastelloy C276 (contact factory for availability)**
Pressure Ranges
Low Pressure
0-1
+
0-2.5
0-5 G 0005
+
0-7.5
0-10 G 0010
0-15 G 0015
G 0001
G 0069
G 0208
Pressure Code
High Pressure
-14.7 to 25
-14.7 to 30 V 0030
-14.7 to 50 V 0050
0-25 G 0025
0-50 G 0050
0-100 G 0100
0-200 G 0200
0-500 0 0500
0-1,000 0 1000
0-3000 0 3000
0-5,000 0 5000
PSIG Measurement
0-7,500 0 7500
0-10,000 1 0000
0-15,000 1 5000
0-20,000 2 0000
For pressure 10,000 PSI and up, use pressure reference digit to specify rst number.
Example, AST46DSP15000P4X1000 = 15,000 PSI pressure range. Display for 20,000 PSI pressure range has maximum reading of 19,999 PSI.
© 2014 American Sensor Technologies Inc. AST46DS 01/21/2014.
V 0025
Pressure Code
All specications subject to change without notice.
Loading...