AST AST4300 Datasheet

Non-Incendive
AST4300 Pressure Transducer / Transmitter
The AST4300 is a stainless steel pressure transducer / transmitter for use in hazardous areas. In addition to its rugged construction and best price-to­performance ratio in the industry, the AST4300 is the solution for pressure measurement for a variety of applications.
TM
Environmental Data
Temperature
Operating -40 to 80°C (-40 to 176°F)
Storage -40 to 100°C (-40 to 212°F)
Thermal Limits
Compensated Range 0 to 55°C (32 to 132°F)
TC Zero <±1.5% of FS
TC Span <±1.5% of FS
Other
Shock EN 60068-2-27
Vibration EN 60068-2-6, 60068-2-64, and IEC 68-2-32
EMI/RFI Protection: Yes
Rating: IP-66
Benefits
 Class I Div 2 Groups A, B, C, D
 High Strength Stainless Steel Construction
 No Oil, Welds or Internal O-rings
 Wide Operating Temperature
 Pressures from Vacuum to 20,000 PSI
 Low Static and Thermal Errors
 Unparalleled Price and Performance
 Compatible with Wide Variety of Liquids
and Gases
 EMI/RFI Protection
Applications
 Refrigeration
 Water Management
 Industrial OEM Equipment
 Oil & Gas Platforms
 Pressure Instrumentation
 Gas Compression & Storage
 Test Stands
 Oxygen Delivery Systems
 Hydrogen Fuel (316L)
Performance @ 25°C (77°F)
Accuracy* < ±0.25% BFSL (<±0.5% from 7,500 up to 20,000 PSI)
Stability (1 year) ±0.25% FS, typical
Over Range Protection 2X Rated Pressure
Burst Pressure 5X or 40,000 PSI (whichever is less)
Pressure Cycles > 100 Million
* Accuracy includes non-linearity, hysteresis & non-repeatability
Electrical Data
Output
Excitation 10-28VDC 10-28VDC 5VDC, regulated
Output Impedance >10k Ohms <100 Ohms, Nominal <100 Ohms, Nominal
Current Consumption: 20mA, typical 5mA, typical <10mA
Bandwidth (-3dB): DC to 250 Hz (-3dB): DC to 1kHz (-3dB): DC to 1kHz
Output Noise: - <2mV RMS <2mV RMS
Zero Offset: <±1% of FS <±1% of FS <±1% of FS
Span Tolerance: <±2% of FS <±1.5% of FS <±1.5% of FS
Output Load: 0-800 Ohms@10-28VDC 10k Ohms, Min. 10K Ohms, Min.
Reverse Polarity Protection
American Sensor Technologies 450 Clark Dr., Mt. Olive, NJ 07828 phone (973) 448-1901 fax (973) 448-1905 email: info@astsensors.com
4-20mA 1-5VDC, 1-6VDC 0.5-4.5V Ratiometric
Yes Yes Yes
Ordering Information
TM
AST4300 A 00500 P 4 1
Series Type
Process Connection
A= 1/4” NPT Male B= 1/8” NPT Male* C= 1/4” BSPP Male
*Not available under 50PSI (not available in 316L) **Pressures up to 15,000 PSI ***Pressures from 10,000 to 20,000 PSI, not available in 316L
Pressure Measurement
Insert 5-digit pressure code
Pressure Unit
B= Bar K= kg/cm
Outputs
1= 0.5-4.5V ratiometric 3= 1-5V
Electrical
I= DIN 43650A
L= Conduit tting, Cable 2 ft. (0.6 m) M= Conduit tting, Cable 4 ft. (1.2 m)
Wetted Material
0= 17-4PH 1= 316L
I= 1/4” NPT Female** P= 1/2” MNPT** W= F250C Female Autoclave***
2
4= 4-20mA (2 wire loop powered) 6= 1-6V
P= PSI
2= Inconel 718 (consult factory on availability) 4= Hastelloy C276 (consult factory on availability)
N= Conduit tting, Cable 6 ft. (1.8 m) P= Co nd ui t  tt in g, Ca bl e 1 0 f t. (3 .0 m)
4 = Mini-Fast (CSA Only)
L
000
-SS
Options
000= No Options
Approval
(Left Blank)= UL ANSI/ISA 12.12.01 Class I Div 2 Non-Incendive Groups A, B, C, D (formerly UL1604)
-SS= Add “-SS” for CSA213 Class I Div 2 Non-Incendive Groups A, B, C, D and ANSI/ISA 12.27.01 Single Seal Approval
-Z= Add “-Z” for CRN Registered to ANSI/ASME B31.3. Contact factory for material, pressure, and process connection options (includes -SS approvals)
Note: CSA approved products require case/earth ground electrical connection. See wiring installation sheet for further details
+
-1 to 2**
V0002**
Pressure Code
BARG Measurement
0-700 00700
Typical ranges. All ranges between 0-25 PSI and 0-20,000 PSI available.
-14.7 to 25**
0-25 00025 0-2 00002
0-50 00050 0-5 00005
0-100 00100 0-7 00007
0-150 00150 0-10 00010
0-200 00200 0-20 00020
0-250 00250 0-35 00035
0-500 00500 0-50 00050
0-1,000 01000 0-100 00100
0-2,500 02500 0-250 00250
PSIG Measurement
CSA ONLY
0-5,000 05000 0-350 00350
0-7,500 07500 0-500 00500
0-10,000 10000
0-15,000
0-20,000 20000
Pressure Code
CSA ONLY
Pressure Ranges
V0025**
15000
+
**Compound ranges up to -14.7 to 500 PSI available. Please consult factory.
www.astsensors.com
© 2014 American Sensor Technologies Inc. AST4300 06/11/2014
All specications subject to change without notice.
Loading...