ASSALOY SCYMCA1 User Manual

Attention Installer
Cylindrical Lockset IN100 WiFi Installation Instructions
FM404 07/16
Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
Misalignment can cause premature wear and a lessening of security.
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
IN100 Cylindrical Lock
1) Warning ................................................................................2
2) General Description .............................................................3
3) Specifications / Features ....................................................3
4) Product Illustration .............................................................4
5) Installation Instructions ......................................................6
6) Operational Check ............................................................ 16
7) LED Indications..................................................................17
Table of Contents
1) Warning
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced technician for help
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
!
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:
• Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges,
!
latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door.
• Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
• Do not touch pins, leads or solder connections on the circuit boards
Copyright © 2016 Corbin Russwin, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
2
IN100 Cylindrical Lock
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
The Corbin Russwin® IN100 lock with Aperio™ Technology makes it easy and cost-effective to bring access control to more doors. It uses local wireless communication between the lock and an Aperio hub to connect to an access control system, eliminating the greatest cost and inconvenience of traditional access control – the wiring at the door.
The IN100 utilizes HID® 125 kHz prox or 13.56 MHz iCLASS® smart card technology, and all technology features are supported by the physical security of Corbin Russwin ANSI/BHMA Grade 1 hardware.
This product is operated by six (6) “AA” alkaline batteries. Corbin Russwin locks are designed with quality components to provide high security, performance and durability.
Hardware Specifications
2) General Description
3) Specifications / Features
• Latch – Stainless steel, ½” (13mm) throw Optional: ¾” (19mm) throw deadlocking fire latch for pairs of doors
• Deadlocking latch prevents manipulation when door closed
• Door Thickness – Standard 1-3/4” (44mm) to 2” (50mm) Optional 2” (50mm) to 2-1/4” (57mm)
• UL fire listed
A weather-protective gasket is required for exterior applications.
Electronic Specifications
• Input Power: DC 9V, 1.5A (6 AA alkaline batteries)
• Optional hard-power 12VDC to 24VDC
• HID® multiCLASS SE® technology offers support for the following credentials:
High Frequency (13.56 MHz):
HID iCLASS
HID iCLASS SE® (SIO-enabled)
HID iCLASS
HID MIFARE® SE
HID DESfire® EV1 SE
MIFARE Classic
DESfire EV1
Low Frequency (125 kHz):
HID Prox
NFC-enabled Mobile Phones
®
®
®
Seos
• Outside lever controlled by reader or key retracts latch
• Inside Lever produces REX (request to exit) signal
• Complete monitoring of door - DPS (External Door Position Switch supplied)
• May be used for both indoor and exterior applications.
• Uses low-rate wireless personal area networks (IEEE 802.14.4)
• Multiple time zone and holiday access scheduling
• First-in unlock or automatic unlock configuration, based on specified time schedule
• Uses AES 128-bit wireless encryption*
• Privacy button
*For specific security information, please contact your local ASSA ABLOY Door Security Solutions sales consultant or call 800-810-WIRE.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
!
3
IN100 Cylindrical Lock
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
4) Product Illustration
1
2
3
4
5
Reader Module
ITEM PART NUMBER/ORDER STRING DESCRIPTION COLOR/TRIM QTY
1 IN-100-EM01CL33134-IP-B HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
IN-100-EM01CL33134-IP-W HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
IN-100-EM01CL33134-IP-MB-[finish]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE®
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
IN-100-EM01CL33134-IP-MW-[finish]* HID iCLASS®, HID iCLASS SE® (SIO-enabled), HID iCLASS® Seos™, HID MIFARE
SE, HID DESfire® EV1 SE, HID Prox®, NFC-enabled mobile phones
IN-100-EM01CL33134-IPS-B All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 Black 1
IN-100-EM01CL33134-IPS-W All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 White 1
IN-100-EM01CL33134-IPS-MB-[finish]* All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 Black with metal trim 1
IN-100-EM01CL33134-IPS-MW-[finish]* All credentials supported by the IP option plus MIFARE Classic and DESfire EV1 White with metal trim 1
2 820F558 Inside Mounting Kit (mounting plate & hardware) 1
3 820F549 IN100 Controller 1
4 N/A AA battery 6
5 820F489 Inside Escutcheon Black 1
820F499 Inside Escutcheon White
820F525 FIN* Inside Escutcheon Black with metal trim
820F535 FIN* Inside Escutcheon White with metal trim
6 FM356 Field prep template (not shown) 1
7 T31203 Door manufacturers template (not shown) 1
-- FM404 Instructions (this manual) 1
Black 1
White 1
Black with metal trim 1
®
White with metal trim 1
* Specify finish
4
IN100 Cylindrical Lock
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
Tools Required:
• Phillips Screw Driver #2, #3
• Flat Blade Screw Driver (Standard size)
• 1/8” Security Allen Wrench (supplied)
4) Product Illustration (Continued)
4
2
3
1
1* 785F628 CL33134 Cylindrical lock with fixed core cylinder 1
785F638 CL33134 Cylindrical lock with removable core cylinder
2 785F488 Inside Spring Cassette - IN100 REX (1-3/4” - 2” Door) 1
785F498 Inside Spring Cassette - IN100 REX (2-1/4” Door)
3 783F208 Outside Spring Cassette 1
4 820F609 DPS (Door Position Switch) Kit 1
*The IN100 CL33134 cylindrical lock supports Escape Return functionality.
For parts not listed, refer to CL3300 Parts and Service Manual.
5
IN100 Cylindrical Lock
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
1. Verify Hand and Bevel of door
Illustrations shown are as viewed from the outside or secure side of opening.
5) Installation Instructions
Left Hand
Hinges Left.
Open Inward.
“LH”
2. Door Preparation
Prep door according to supplied door marker (FM356). For door manufacturer templates
visit www.corbinrusswin.com and reference template # T31203.
Outside Face
of Door
Raceway for Optional
Remote Power
Through-bolt Hole
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
“LHRB”
Fig. 1
Wood Door
shown
Right Hand Hinges Right. Open Inward.
“RH”
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
“RHRB”
Inside Face
of Door
Raceway for Optional Remote Power
Through-bolt
Hole
Raceway for
Lockbody
Harness
Through-bolt Hole
External DPS
Hole
Cylindrical
Pocket and
Pre-drilled Tap Holes
Lever Handle
Hole
Fig. 2
6
Raceway for
Lockbody
Harness
Through-bolt
Hole
Cable Hole
Loading...
+ 14 hidden pages