5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Installation Instructions
Profile Series v.S2 WiFi
Mortise Lock
A7786E
10/10
Copyright 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
Warning: Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
FCC:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
Statement: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met.
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des
règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui
peut causer l’opération peu désirée.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
!
SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated for,
or intended for use in life safety applications.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
1-800-810-WIRE • www.sargentlock.com • A7786E
Profile Series v.S2 WiFi Mortise Lock
2
General Description
The SARGENT Profile Series v.S2 mortise lock is available with either a Prox 125 kHz or an HID iCLASS®
13.56 MHz technology reader. It is designed for applications requiring wireless access control.
The v.S2 is a self-contained microprocessor-controlled access control product with non-volatile memory.
It is able to utilize the existing wireless LAN (802.11b/g) in order to communicate with the access control
system. The v.S2 lock holds a total of 2000 different user codes.
This product is operated by six (6) “AA” alkaline batteries or a SARGENT 3267 9VDC power supply. SARGENT
mortise locks are designed with quality components to provide high security, performance and durability.
The Profile Series v.S2 mortise lock may be used for both indoor and outdoor applications. A weatherprotective gasket is recommended for outdoor applications (Provided with unit).
HID® and iCLASS® are registered trademarks of HID Global Corporation.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
Profile Series v.S2 WiFi Mortise Lock
Step #5 – Install Gasket (for Exterior Doors)
For exterior applications, use weather seal gasket between escutcheon
and outside door surface. To apply weatherseal gasket:
1. Carefully remove the backing from the gasket. (Fig. 5A).
2. Apply gasket to escutcheon:
a. Starting in one place, press the adhesive side
of the gasket firmly against the escutcheon.
b. Work around the escutcheon, pressing the
sticky side of the gasket firmly against the
escutcheon edge.
c. The gasket should be aligned so that all edges
of the escutcheon are covered.
Fig. 5A
3. Attach escutcheon to the door.
Note: The 43 cylinder may be used with or without a gasket.
Step #6 – Install Gasket (for Exterior Doors)
1A . Fo r fire ra ted doo rs :feed ribbon cable with connector and ground wire
from outside of door through weatherseal gasket and fire stop plate (Fig. 6A).
Note: Install ribbon cable with cable exiting down
1B. For no n-fire rate d doors : feed ribbon cable with connector and ground
wire from outside of door through weatherseal gasket (if used)
and weather conduit (Fig. 6B).
Note: Install ribbon cable with cable exiting down
2. With outside lever horizontal, locate the outside escutcheon on the door,
while directing the mounting posts through the door and lock body (Fig. 6B).
Make sure the lever spindle is properly engaged in lock.
7. On the inside of the door, insert spindle into square hole
of mortise lock.
8. Slide inside adapter and plate
assembly over spindle and loosely
secure with 2 through -bolt
screws (#8-32 x 5/8”).
Note: For 8276 and 8278,
loosely thread cylinder
through escutcheon
and into the lock body
before tightening the
lock case screws
and escutcheon
through bolts.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
Profile Series v.S2 WiFi Mortise Lock
Step #9 – Install Inside Escutcheon
1. Gently fold the excess ribbon connector and ground
wire into the top hole, JST connectors and ground
wire into offset middle hole, and mortise and AX/DPS
wires into bottom hole, being careful not to pinch
wires (Fig. 9A).
2. Insert (2) #8-32 x 1-1/4" screws through inside
escutcheon and thread into outside escutcheon.
Straighten escutcheons and tighten securely.
Inside of Door
Step #10 – Install Inside Lever
1. Slide lever handle onto spindle
until fully seated (Fig. 10A).
2. Tighten the set screw securely with
1/8" hex wrench.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
Profile Series v.S2 WiFi Mortise Lock
Step #13 – Install (or Replace) Batteries
IMPORTANT: Do not install batteries if controller is powered by external power supply.
1. To install or replace batteries, first remove the battery cover
(if necessary) using the provided security tool (Fig.13A).
2. Unscrew the bottom screw of the battery keeper
and remove the battery keeper, being careful
not to break the tabs at top that hold it in
place (Fig.13B)
3. Place (6) “AA” alkaline batteries in the
compartment, being careful to align
polarity properly.
4. Replace battery keeper being careful to engage
tabs at top to hold it in place (Fig. 13B).
5. Attach battery cover to inside escutcheon,
making sure to line up tabs with retaining
slots in battery cover.
6. Secure with the security screw
using tool. (Fig. 13A).
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
.
10/15/10
SARGENT Manufacturing
100 Sargent Drive
New Haven, CT 06511 USA
800-810-WIRE (9473) • www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices,
electro-mechanical products and access control systems for new construction, renovation, and replacement applications.
The company’s customer base includes commercial construction, institutional, and industrial markets.