ASSALOY SCYICLS0 User Manual

ACS Report Number: 10-0199.W06.11.A
Certification Exhibit
FCC ID: U4A-SCYICLS0
IC: 6982A-SCYICLS0
FCC Rule Part: 15.225

Manufacturer: Assa Abloy, Inc.

Model: S1-IA/IK, S2-IA/IK
Manual
Model S2-IA/IK
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Installation Instructions Profile Series v.S2 WiFi Mortise Lock
A7786E
10/10
Copyright 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents
Warning ...................................................................................2
1
General Description .................................................................3
2
Hardware Specifications .........................................................3
3
Electronic Specifications .........................................................3
4
5
Installation Wiring Overview ...................................................3
6
Lock Wiring ..............................................................................4
7
Parts Breakdown .....................................................................5
8
Installation Instructions ..........................................................7
9
Operational Check ................................................................15
1
Warning
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
Statement: The term “IC:” before the radio certification number only signifies that Industry Canada technical specifi­cations were met.
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
!
SARGENT Mfg. Co. v.S Series locksets utilizing a door position switch (DPS) are not rated for, or intended for use in life safety applications.
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
1-800-810-WIRE • www.sargentlock.com • A7786E
Profile Series v.S2 WiFi Mortise Lock
2
General Description
The SARGENT Profile Series v.S2 mortise lock is available with either a Prox 125 kHz or an HID iCLASS®
13.56 MHz technology reader. It is designed for applications requiring wireless access control. The v.S2 is a self-contained microprocessor-controlled access control product with non-volatile memory. It is able to utilize the existing wireless LAN (802.11b/g) in order to communicate with the access control system. The v.S2 lock holds a total of 2000 different user codes.
This product is operated by six (6) “AA” alkaline batteries or a SARGENT 3267 9VDC power supply. SARGENT mortise locks are designed with quality components to provide high security, performance and durability.
The Profile Series v.S2 mortise lock may be used for both indoor and outdoor applications. A weather­protective gasket is recommended for outdoor applications (Provided with unit).
HID® and iCLASS® are registered trademarks of HID Global Corporation.
Hardware Specifications
3
• Latch: One-piece stainless steel, 3⁄4" projection
• Deadbolt: One-piece hardened stainless steel
• Guardbolt: Stainless steel, non-handed
• Handed: Easily field reversible without opening case
• Case: 12-gauge, heavy duty wrought steel
• UL Listed (3 hours)
Electronic Specifications
4
• Wireless (WiFi 802.11 b/g) online, battery-operated
• 2000 Users per lock (more possible with software)
• 10,000 Event audit trail
• Centralized lock management
• Door Status Monitoring*
• Easy installation (no need to hardwire)
• Outside lever for iCLASS controlled by any 13.56 MHz iCLASS credential
• Outside lever for 125 kHz prox controlled by any combination of keypad, prox reader, or mechanical cylinder
• Inside lever retracts latch and deadbolt
• Locks furnished for 1-3/4" doors. Can be furnished for other door sizes upon request. Consult factory.
• Input Power: DC 9V, 1.5A (6 AA alkaline batteries or optional hard-powered)
• Lockdown capable*
• HID iCLASS (13.56 MHz) and 125 kHz prox (proxim­ity) compatible (26-39 bit formats)
• AWE Prefix available for WPA2, PEAP and EAP-TS Wireless Encryption Support
5
Installation Wiring Overview
SARGENT Profile Series WIFI v.S2 Typical Application
Internal Building
Network (Intranet)
Ethernet LAN
Lock Management
Tool (LMT)
Lockdown and real-time door status monitoring available
*
only when lock is hard-powered
Network Interface Card
802.11b/g Wireless Network Device
v.S2 Lock
1-800-810-WIRE • www.sargentlock.com • A7786E 3
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
6
Lock Wiring
Profile Series v.S2 WiFi Mortise Lock
DPS
TB1
2
3
4
5
6
7
8
RX NC (GREEN)
RX COM (WHITE)
DX NC (GREEN/WHITE)
Motor B (BLACK)
DX (WHITE/BLACK)
LX COM (RED/GREEN
LX NO (RED/YELLOW)
E1
1
Motor A (RED)
TB2
4
3
2
1
(-) (BLACK)
(+) 9VDC (RED)
AX/DPS NC (PINK)
AX/DPS COM (VIOLET)
Controller Board Connectors
(Inside Escutcheon)
8
7
6
5
Unused
Unused
Unused
EGND (GREEN)
Ring Terminal
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10
4 1-800-810-WIRE • www.sargentlock.com • A7786E
From
Lock Body
From Trim
DPS
Power
Profile Series v.S2 WiFi Mortise Lock
7
Parts Breakdown 125 kHz Prox and 13.56 MHz iCLASS
6
9
5
9
8
7
9
4
3
2
10
9
16
11
12
9
7
13
1
15
14
15
1-800-810-WIRE • www.sargentlock.com • A7786E 5
Copyright © 2010, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/15/10