Assa Abloy: Sargent Manufacturing and Corbin Russwin Factory Installation
Instructions
Factory Installation Instructions for Reader assemblies with Bluetooth. Model: BLE9117K
![](/html/97/97db/97dbcaa2b0f6b76dbd79f6f1cf3404b519454e34a6f0ad6abd76ede616712ce9/bg2.png)
Assembly Drawings and Instructions:
52-4964TAB
Model BLE9117K is Sargent assembly P/N 52-4964 and Corbin Russwin assembly P/N 851P969
Factory Configuration Instructions:
Model BLE9117K shall be programmed at the manufacturing facility with firmware.
Field Configuration Instructions:
BLE9117K LF (125kHz) and HF (13.56MHz).
LF and HF may only be field configured by a certified technician with the Assa Abloy LCT (Lock
Configuration Tool) for card credential type, and either ultra-low power mode or normal power mode.
BLE9117K Bluetooth.
At the customer site, encryption keys are loaded by a “Mobile Keys” certified technician using an HID
configuration card. This installation can be performed on mobile enabled readers only. Once the
“Mobile Keys” have been loaded interface with mobile devices can be achieved. The HID BLE
Configuration application is currently available on Android OS and provides additional configuration that
can be used to configure tap sensitivity and transmission power. Transmission power is restricted to a
maximum of +4dBm. The HID BLE Configuration application can be used to upgrade the BLE devices
firmware using the OTA technology. Field firmware upgrades can only be performed through and HID
certified technician that are authorized to use a controlled administration card.