Installation and
Operating Instructions
ADAEZ Wireless Interface Module (WIM)
Note
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate this device. This device complies with part 15 of
the FCC Rules. Operation is subject to the condition that this device does not cause harmful
interference.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequenc y
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
This device complies with Industry Canada’s licence-exempt RSSs. O per ation is subject to
the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1) l’appareil ne doit pas produire de brouillage;
2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
To obtain the latest manual and template revisions or to view installation and programming videos
go to www.nortondoorcontrols.com. For technical support call 800-438-1951 x 4.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Installation and Operating Instructions
1. PURPOSE
1.1 Discussion
This manual provides system description, installation instructions, operating instructions, and
troubleshooting recommendations for the ADA EZ Wireless Interface Module (refered t o as the
WIM).
The ADA EZ WIM allows the ADA EZ swing door operator to interface with the ADA EZ wired
or wireless pushbuttons, wireless remote , an electric lock, fire panel, access control, and an
outside pushbutton disable contact.
1.2 Applicability
This manual is applicable to the ADA EZ series Wireless Interface Module.
2. PREREQUISITES
2.1 An ADA EZ swing door operator installed according to ADA EZ Pro Installation and Operating
Instructions p/n 700002 with optional Hardwire Kit p/n 1015 or 24VDC (500ma minimum)
power supply by others.
2.2 Plastic electrical enclosure for WIM.
2.3 12 or 24V AC or DC to power the WIM.
2.4 24VDC is REQUIRED if the ADA EZ swing door operator will be powered thorough the WIM
with the supplied cable
2.5 Protective barrier (caution/warning tape) has been set up to prevent unauthorized access to work
area.
2.6 The door has been secured to prevent unexpected opening or closing during installation.
3. PRECAUTIONS
3.1 This product is intended for interior use only.
3.2 An operating door creates pinch hazard s. Be careful making operating adjustments while the door
is moving.
3.3 The transformer wiring must not be concealed behind walls or routed through doorways, window
openings, walls, ceilings, or floors. Also, this wiring must be secured to prevent it from becoming
entrapped in the moving parts of the operator or door.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
4. SYSTEM DESCRIPTION
4.1 General
The ADA EZ WIM allows the ADA EZ swing door operator to interface with:
• ADA EZ wireless (RF) push buttons or
• Wired push buttons
• ADA EZ wireless (RF) hand held transmitter
• Electric Lock
• Access Control
• Fire Panel
• Switch to disable outside pushbutton
4.2 Inputs and Outputs
4.2.1 Pushbuttons: A wired and wireless input is provided for an INSIDE and an OUTSIDE
pushbutton. An optional handheld transmitter p/n HAND-HELD-TX 1031may be
connected to either the INSIDE or OUTSIDE rf pushbutton.
4.2.2 Operator Connection: A connector is provided to plug in the ADA EZ swing door
operator into the WIM module
4.2.3 Access Control: Contacts are provided to interface the WIM with access control.
4.2.4 Lock Interface: Contacts are provided to control an electrical lock.
4.2.5 Lock Power: Contacts are provided to po wer an electric lock.
4.2.6 Outside Pushbutton Disable: A contact is provided to disable any input from an outside
pushbutton.
4.2.7 Power Input: A power input connector is provided to power the WIM by the optional
hardwire kit p/n KIT-HDWR 1015P.
4.2.8 Signal Delay: A switch is provided to enable a 1 second delay before sending an activate
signal to the door operator
5. INSTALLATION INSTRUCTIONS
5.1 Mount the WIM enclosure in a remote loca t ion as desired.
NOTE
The ADA EZ WIM may be powered by 12 or 24 Volts AC or DC current. If the door operator will be
powered directly from the WIM, a 24VDC 750ma (minimum) power supply is required.
5.2 Provide power to the WIM. (Refer to Figure 1)
5.2.1 If the Optional 1015P hardwire kit is used to power the WIM and door operator, plug the
provided GREEN connector into the power port as shown.
5.2.2 If Power supply is by others, connect the power supply using the provided GREEN
connector. If a DC power supply is used connect the ground to the terminal marked “-“
and the positive to the terminal marked “+”.
5.2.3 If the operator will be powered through the WIM, use the supplied Operator Wire