Installation instructions
Combination hob induction/gas
The fitting of the appliance should only be carried out by a authorised person/licensed gasfitter. Please read the safety regulations. See the data plate for information regarding the total gas consumption, gas type and gas pressure.
Preparations for installation
Pictograms used
Important information
Gas connection
Electrical connection
05
This appliance must be earthed
The electrical connection must comply with national and local regulations.
Connected load
Free space around appliance
A (>mm) C (>mm) D (>mm) E (> mm) 650 450 40 120
05
1/2” ISO 228 / 1/2" ISO 7-1
The gas connection must comply with national and local regulations.
The hotplate can be connected with rigid pipe as specified in AS/NZS 5601.1current edition.
min. B+D
C
B
E
A
D
L1 (W) L2 (W) L3 (<W) Total load (W) HIG1995AD
A (mm) B (mm) C (mm) D (mm) E (mm) HIG1995AD 904 522 54 265 180
3700 3700 5 7405
E
D
A
B
C
Accessibility!
When the appliance is connected with a hose assembly, the supply point shall be accessible with the appliance installed.
F
E
E/F
C
D
A (mm) B (mm) C (mm) D (>mm) E (>mm) F (>mm) G H HIG1995AD
600 860 490 60 40 50 66 100
H
G
A
B
Y:
metal
y
oven
Gas supply valve shall be accessible
oven
Placing sealing tape
Worktop
y
>60º C
<60º C
x
x
X:
safety hose Gas supply valve shall be accessible
05
C
C
varnish
Gas connection
Electrical connection
05
1/2“ ISO 228
1/2“ ISO 7-1
PTFE tape
Fitting of appliance regulator for Natural gas or test point adaptor for LPG. Check and set
the gas pressure with appliance operating!
GAS BURNER INJECTOR ADJ. SCREW BURNER RATE GAS PRESSURE BURNER (MM) (MM) (MJ/h) (kPa)
N.G. Wok (inner) 1.20 + 0.66 0.60 8.80 1.0 Wok (outer) 2.10 + 0.66 0.60 19.70
ULPG Wok (inner) 0.63 + 0.40 0.34 7.50 2.75 Wok (outer) 1.00 + 0.40 0.34 14.80
3N 380-415V 50/60Hz - 3x 16A
3 phases - 1 neutral
Cross sectional area
5x1,5mm
2N 380-415V 50/60Hz - 2x 16A
2 phases - 1 neutral
2
Cross sectional area
4x1,5mm
2
1N 220-240V 50/60Hz - 1x 32A
1 phase - 1 neutral
Cross sectional area
3x4mm
Consult the wiring diagrams on the underside of the appliance/Make the required connections on the connecting block.
05
2
Ventilation
05
2
min. 200 cm
Check that the connections are gastight.
2
05
3
3
150
L
drawer
min.100 mm
L
1
700005759000