ASI-Automation Systems Interconnect XCSL Series Data Sheet

ASI
Automation Systems Interconnect, Inc
Innovative Interconnect and Interface Solutions
CHAPTER 1
CSL
SERIES
SWITCH MODE POWER SUPPLIES EASY POWER LINE
• Single phase and DC input
• Short circuit, overload, input and output overvoltage protections
• Over temperature protection
• Suitable for standard applications
• Alarm contact
NOTE
Please refer to the datasheet for more details Above overcurrent limit, the protection starts cycling in
ON/OFF mode(hiccup autoreset), the maximum current supplied depends by the line resistance
― ―
Economy Power Supplies
XCSL Series
CODE
TYPE
INPUT TECHNICAL DATA
Input rated voltage
Input voltage AC
Input voltage DC
Frequency
Current consumption
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limiting
Short circuit peak current
Ripple @ nominal ratings
Hold up time
Status indication
Alarm contact
Parallel connection
Redundant parallel connection
GENERAL TECHNICAL DATA
Efficency
Dissipated power
Operating temperature range
Input / output isolation
Input / ground isolation
Output / ground isolation
Standard / approvals
EMC Standards
Overvoltage category / Pollution degree
Protection degree
Connection terminal IN/OUT
Housing material
Dimension
Approximate weight
Mounting information
APPROVALS
ACCESSORIES
Mounting rail (IEC60715/TH35-7.5)
Mounting rail (IEC60715/TH35-15)
Marking tag
CSL1-072W/024V/AA
XCSL1072W024VAA
120–230 Vac
85…264 Vac
100…370 Vdc (derating Uin<130 Vdc)
47...63 Hz
0.8 A (120 Vac) / 0.4 A (230 Vac)
20 A
> 0.65
T 2 A
MCB: C-4 A / Fuse: T-4 A
24 Vdc ±1%
16 … 28 Vdc
3 A at 50°C
> 6 A per > 30 s
15 A for 50 ms
40 mVpp
20 ms (120 Vac) / 70 ms (230 Vac)
LED "DC OK"
dry contact, max. 1A @ 24 Vdc (Uout >22.0 Vdc)
possible
possible with external ORing diode
87% (120 Vac) / 87% (230 Vac)
10.8 W (120 Vac) / 10.8 W (230 Vac)
–20...+70°C (derating -3 W/°C >50°C)
3 KVac / 60 s (SELV output)
1.5 kVac / 60 s
0.5 kVac / 60 s
EN 60950-1
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4
II / 2
IP 20
2.5 mm² / 2.5 mm²
aluminium
40x115x115 mm
400 g
vertical on a rail, 20 mm from adjacent components
UL 508
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
CSL1-120W/024V/AA
XCSL1120W024VAA
120–230 Vac
85…264 Vac
100…370 Vdc (derating Uin<130 Vdc)
47...63 Hz
1.5 A (120 Vac) / 0.8 A (230 Vac)
20 A
> 0.65
T 3.15 A
MCB: C-4 A / Fuse: T-4 A
24 Vdc ±1%
16 … 28 Vdc
5 A
>6.2 A for >30 s
15 A for 50 ms
50 mVpp
20 ms (120 Vac) / 20 ms (230 Vac)
LED "DC OK"
dry contact, max. 1A @ 24 Vdc (Uout >22.0 Vdc)
possibile
possible with external ORing diode
85% (120 Vac) / 85% (230 Vac)
21.2 W (120 Vac) / 21.2 W (230 Vac)
–20...+70°C (derating -3 W/°C >50°C)
3 KVac / 60 s (SELV output)
1.5 kVac / 60 s
0.5 kVac / 60 s
EN 60950-1, EN 62368-1
EN 61000-6-2, EN 61000-6-4
II / 2
IP 20
2.5 mm² / 2.5 mm²
aluminium
40x115x115 mm
400 g
vertical on a rail, 20 mm from adjacent components
UL 508
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Loading...