DC/DC Insulated converters
output power 120 W
• DC wide range input
•
Short circuit, overload, over temperature protection
• Compact design
NOTES BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Inrush current is measured with input supplied by a battery;
the current peak vary depending on the internal impedance of
the current source and depending on cables and connections
resistance.
(2) Over 50°C (122°F) apply a derating -3 W/°C, max 60°C
(3) According to EN60950 insulation tests on input side must be
made only with DC instruments.
55
(2.17 in)
115
(4.53 in)
130
(5.12 in)
VERSIONS
12 Vdc / 24 Vdc 5 A
24 Vdc / 12 Vdc 7 A
24 Vdc / 24 Vdc 5 A
48 Vdc / 24 Vdc 5 A
Cod. XCSA120BC Cod. XCSA120CB Cod. XCSA120CC Cod. XCSA120DC
CSA120BC
CSA120CB
CSA120CC
CSA120DC
INPUT TECHNICAL DATA
Input rated voltage
Current @ Iout max.
Inrush peak current
Standby power
Internal protection fuse
External protection on AC line
Overvoltage input protection circuit
12 Vdc (range 10.5…18 Vdc) 24 Vdc (range 18…36 Vdc) 24 Vdc (range 18…36 Vdc) 48 Vdc (range 36…72 Vdc)
12 A ±10% 5.1 A ±10% 5.8 A ±10% 2.8 A ±10%
< 60A / < 2ms (1) < 100A / < 2ms (1) < 90A /< 2ms (1) < 120A / < 2ms (1)
<1.5 W @ 12 Vdc <1 W @ 24 Vdc <1.5 W @ 24 Vdc <2 W @ 48 Vdc
T 20 A replaceable T 10 A replaceable T 5 A replaceable
≥25 A C characteristic ≥13 A C characteristic ≥6 A C characteristic
Passive varistor and active
shutdown at 19 Vdc
Passive varistor and active shutdown at 38 Vdc Passive varistor and active
shutdown at 76 Vdc
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 12...15 Vdc 24 Vdc 24 Vdc
Output adjustable range 22.5...27.5 Vdc 12...15 Vdc 22.5...27.5 Vdc 22.5...27.5 Vdc
Continuous current 5 A @ 50°C (2) 7 A @ 50°C (2) 5 A @ 50°C (2) 5 A @ 50°C (2)
Overload limit 6.5 A 9.1 A 6.5 A 6.5 A
Short circuit peak current 12 A for 300 ms 15 A for 300 ms 12 A for 300 ms 13 A for 300 ms
Load regulation <0.5%
Ripple @ nominal ratings ≤ 100 mVpp ≤ 150 mVpp ≤ 200 mVpp
Hold up time @ In
Overload / short circuit protections hiccup at the overload limit with auto reset / over temperature protection
Status display “DC OK” green LED
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
>1 ms
>2 ms >4.5 ms
GENERAL TECHNICAL DATA
Efficiency (Uin 110 Vdc) > 83% >87% >87% >90%
Dissipated power (Uin 110 Vdc) <25 W <16 W <18 W <13 W
Operating temperature range –20...+60°C, with derating over 50°C (2)
Input/output isolation 2.1 kVdc / 60s (3)
Input/ground isolation 1.41 kVdc / 60s (3)
Output/ground isolation 0.75 kVdc / 60s (3)
Standard/approvals IEC950, EN60950
EMC Standards EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-5-5, EN61000-4-6, EN61000-4-11
MTBF @ 25°C @ nominal ratings >500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
Overvoltage category/Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection terminal 2.5 mm² pluggable screw type
Housing material aluminium
Approx. weight 550 g (19.40 oz)
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —