ASI-Automation Systems Interconnect XCLT16AC Data Sheet

LED testing modules CLT series
• Compact dimensions
• Integrated limitation resistence
• Suitable only for LED without resistance limiter
A
NOTES BLOCK DIAGRAM
(1) Led test can be performed through a negative signal on the com-
mon output
(2) Led test can be performed hrough a positive signal on the common
input
VERSIONS DIMENSIONS common negative (1) common positive (2) (A x B x C) Item Cat. No. Item Cat. No.
8 channels 45x65x93 (1.77x2.56x3.66 in) 16 channels 92x65x93 (3.62x2.56x3.66 in)
CLT08AC XCLT08AC CLT08CC XCLT08CC CLT16AC XCLT16AC CLT16CC XCLT16CC
C
B
GENERAL TECHNICAL DATA
Rated voltage 24 Vdc max. 30 Vdc Corrente singolo canale 5 mA @ 24 Vdc Diodes utilizzati Resistenza di limitazione 4,7 KΩ 1/4 W ±5% Repetitive peak reverse voltage 700 V Operating temperature -20…+45°C Housing material polyamide UL94V-0 Protection degree IP 00 IEC529, EN60529 Connection terminal blocks 2.5 mm Mounting information vertical on rail adjacent without gap
1N4007
2
fixed screw type
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35 PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL Jumper bridge black
Loading...