ASI-Automation Systems Interconnect DA100, MF100GR, DA100GR, MF100 Data Sheet

Fuse-holders
with UL94V-0 polyamide insulating body
• for blade fuse acc. to DIN 72581/3F – ISO 8820
• standard versions available in grey RAL 7042 and beige RAL 1001 colours (where indicated)
• with possibility to insert the “Easy Bridge” multi­pole cross connection upstream the fuse
• universal mounting onto both PR/DIN and PR/3 type rails - according to IEC 60715 Std., “G32” and “TH/35” types
The /GR tag indicates the grey colour version.
grey version
beige version
(Ex)i version
TECHNICAL CHARACTERISTICS
function / type rated cross-section (mm2) connecting capacity flexible (mm2) rigid (mm2)
max. flexible with ferrule (mm2)-ferrule type rated voltage / rated current / gauge co rated voltage / rated current / AWG (Ex e) rated voltage / (V) - ­rated impulse withstand voltage / pollution degree insulation stripping length (mm) tightening torque value (test / recommended) (Nm) height / width / thickness height / width / thickness height / width / thickness
nf. to IEC 60947-7-1
/ tightening torque value UL
TH/35 7,5 mm TH/35 15 mm G32
APPROVALS
ACCESSORIES
End sections grey
Permanent cross connection (***) intrinsically IPXXB protected once mounted
Rated current carrying capacity of jumper (A) Cross-connection identification strip (100 mm) green Switchable cross connection - ­Multiple common bar 250 mm - ­Shunting screw and sleeve - ­Coloured partition red, green, white Cross connection barrier red Test plug socket Test plug Modular test plug End section for modular test plug Blade-type fuses In = 2 A according to DIN 72581/3F ISO 8820 In = 5 A
- max voltage 32 V In = 7,5 A
Marking tag printed or blank End bracket
Mounting rail according to IEC 60715 Std.
In = 15 A
(*) value referred to the insulation
characteristics of the terminal block
(**) values referred, respectively, to lower
and upper levels
(***) suitable for all the blade fuses with
similar dimensions
(****) separate configuration conf. to IEC
60947-7-3
Terminal block Jumper Insulation voltage in the above configurations (V) MPFA.4 PTC/4 400 400 400
A.4 PTC/4 400 400
DSF
MPFA.4/GR
Cat. No. MF100GR
MPFA.4
Cat. No. MF100
for blade fuse (***) 2 level - for blade fuse (***) on the upper level 44
0,2 ÷ 6 0,2 ÷ 6 4 - WP40/16 400 V (*) / 15 A (****) / A4 600 V / 6,3 A / 26-10 AWG / 0,5 Nm
6 KV (*) / 3 6 KV / 3 99 0,5 / 1,2 0,5 / 1,2 47 / 47 / 6 68 / 78 / 6 55 / 47 / 6 75 / 78 / 6 51 / 47 / 6 72 / 78 / 6
Approvals referred to the use with CPF/5
fuse carrier cartridge
Type Cat. No. Type Cat. No.
MPS.4/PT/GR
beige
MPS.4/PT
blue
-
PTC/4/02
poles PTC0402
PTC/4/03
poles PTC0403
PTC/4/05
poles PTC0405
PTC04/10
poles PTC0410
PTC/4/00
(42 poles) PTC0400
32 32 PTC/SP
DFU/3 DU03.. DFU/7 DU07.. DFM/500 DF500 DFM/500 DF500
--
--
--
--
F32/2 In = 2 A F32/5 In = 5 A F32/7 In = 7,5 A F32/15 In = 15 A CNU/8-CSC NU...-CS... CNU/8-CSC NU...-CS... BTU for PR/DIN and PR/3 BT005 BT/DIN/PO BT/3-BTO for PR/3 only BT003-BT007 PR/DIN/AC of steel PR001 PR/DIN/AS same with slots PR004 PR/DIN/AL of aluminium PR002 PR/3/AC for PR/DIN and PR/3 PR003 PR/3/AS same with slots PR005
for PR/DIN only BT001
MP901GR MP901
PTC0990
FN03202 FN03205 FN03207 FN03215
SINGLE OR PARALLEL
EXTENDING
PTC jumper configurations
POLE
SKIPPING
ADJACENT
WITHOUT BARRIER
DSFA.4/GR
Cat. No. DA100GR
Cat. No. DA100
0,2 ÷ 6 0,2 ÷ 6 4 - WP40/16 400 V (*) / 15 A (****) - 32 A (**) / A4 300 V / 6,3 - 30 A / 26-10 AWG / 0,5 Nm
Approvals referred to the use with CPF/5
fuse carrier cartridge
DSS/PT/GR DSS/PT
-
PTC/4/02
poles PTC0402
PTC/4/03
poles PTC0403
PTC/4/05
poles PTC0405
PTC04/10
poles PTC0410
PTC/4/00
(42 poles) PTC0400
PTC/SP
F32/2 In = 2 A F32/5 In = 5 A F32/7 In = 7,5 A F32/15 In = 15 A
for PR/DIN and PR/3 BT005
BTU BT/DIN/PO BT/3-BTO for PR/3 only BT003-BT007 PR/DIN/AC of steel PR001 PR/DIN/AS same with slots PR004 PR/DIN/AL of aluminium PR002 PR/3/AC for PR/DIN and PR/3 PR003 PR/3/AS same with slots PR005
for PR/DIN only BT001
DS301GR DS301
PTC0990
FN03202 FN03205 FN03207 FN03215
ADJACENT
WITH BARRIER
STAGGERED
MODE
400
MPFA.4 – detail of the terminal blocks with CNU/8 and SNZ/60 numbering, blade fuse, view of the PTC/4 and PTC. The terminal block can be supplied with a non-polarised LED signal circuit, to detect the fuse blow-out status. Two versions are available depending on the different supply voltages. MPFA.4/L12 Cat. No.MF112 (with 12 V non-polarised LED circuit) MPFA.4/L24 Cat. No.MF124 (with 24 V non-polarized LED circuit)
DSFA.4 – detail of the terminal blocks with CNU/8 and SNZ/60 numbering, blade fuse, view of the PTC/4 jumpers on the upper level (upstream the fuse) and on the lower level. The terminal block can be supplied with a non­polarised LED signal circuit, to detect the fuse blow-out status. Two versions are available depending on the different supply voltages. DSFA.4/L12 Cat. No.DA112 (with 12 V non-polarised LED circuit) DSFA.4/L24 Cat. No.DA124 (with 24 V non-polarised LED circuit)
PARALLEL
SKIPPING