ASI-Automation Systems Interconnect CP2-N02 Data Sheet

Industrial Form C – 9.4mm
DUAL JUMPED GROUND
Molded Cable Assemblies
For Solenoid Valve Applications
Molded Cable Assemblies
Black PVC Cable & Connector
9.4
9.4
Part Numbers
Yellow LED
1
2
1
2
Brown
Blue
Grn/Yel
Without LED & Suppression 12 to 24 VAC/DC
Brown
Blue
Grn/Yel
PINS – Molded cable assemblies can be mounted with cable exiting the ground side or opposite.
* Four wire u
nits have one ground pin and 3 “U” shaped pins. Cable exit direction must be specified.
3 Pole (3 Flat Pins)
Cable Length Poles
3 Meter (9.8 Feet) 3 CP2-N02-000-C01-3 5 Meter (16.4 Feet) 3 CP2-N02-000-C01-5 3 Meter (9.8 Feet) 4* 5 Meter (16.4 Feet) 4* 3 Meter (9.8 Feet) 3 CP2-N02-VL1-C01-3 5 Meter (16.4 Feet) 3 CP2-N02-VL1-C01-5
With LED & Suppression 110 to 120 VAC/DC
Brown
Blue
Grn/Yel
Yellow LED
1
2
3 Meter (9.8 Feet) 3 CP2-N02-VL2-C01-3 5 Meter (16.4 Feet) 3 CP2-N02-VL2-C01-5
With LED & Suppression
Technical Information
Connection Voltage As Listed in Drawing Cable Type HO3VVF Nominal Power 3A Jacket Material Black PVC Test Voltage 250VAC - 300 VDC max. Conductor Size 20/3 AWG Insulation Group VDC 0110 1/89 Class C Conductor Color Brn, Blue, (Blk), Grn/Yel Clamping Voltage 24V 42V Nominal Cable OD 6.7mm Clamping Voltage 110V 185V Bend Radius 10 X Cable OD Connector Material Glass Reinforced Polypropylene Center Screw M3 x 21.5mm Protection Rating IP 65; IP 67 on Request Temperature Range -2° to +176° F Contact Resistance < 4 m