Distance between connectors = 7.9” (200mm)
(Other lengths available upon request).
Part Numbers
Heads
Multiple Connector Assemblies
Molded Cable Assemblies
For Distribution Box Applications
Standard main cable length = 3.3 Feet (1 Meter)
(Other lengths available upon request)
DIN 43650 A Industrial Form B Industrial Form C DIN 43650 C
18mm 11mm 9.4mm 8mm
Dual Ground
Ground Up Dual Ground Dual Ground
0 to 250 VAC/DC
Brown
Blue
Grn/Yel
12 to 24 VAC/DC
Brown
Blue
Grn/Yel
1
2
Yellow
LED
2
3
4
1
2
3
2
4
CG1-D02-000-C02-1 CM1-D02-000-B02-1 CP2-D02-000-C02-1 CP1-D02-000-C02-1
CG1-302-000-C02-1 CM1-302-000-B02-1 CP2-302-000-C02-1 CP1-302-000-C02-1
CG1-402-000-C02-1 CM1-402-000-B02-1 CP2-402-000-C02-1 CP1-402-000-C02-1
CG1-D02-VL1-C02-1 CM1-D02-VL1-B02-1 CP2-D02-VL1-C02-1 CP1-D02-VL1-C02-1
CG1-302-VL1-C02-1 CM1-302-VL1-B02-1 CP2-302-VL1-C02-1 CP1-302-VL1-C02-1
CG1-402-VL1-C02-1 CM1-402-VL1-B02-1 CP2-402-VL1-C02-1 CP1-402-VL1-C02-1
With LED & Suppression
110 to 120 VAC/DC
Brown
Blue
Grn/Yel
Yellow
LED
1
2
2
3
4
CG1-D02-VL2-C02-1 CM1-D02-VL2-B02-1 CP2-D02-VL2-C02-1 CP1-D02-VL2-C02-1
CG1-302-VL2-C02-1 CM1-302-VL2-B02-1 CP2-302-VL2-C02-1 CP1-302-VL2-C02-1
CG1-402-VL2-C02-1 CM1-402-VL2-B02-1 CP2-402-VL2-C02-1 CP1-402-VL2-C02-1
With LED & Suppression
Technical Information
Connection Voltage As Listed in Drawing Cable Type HO5VVF or HO3VVF
Nominal Power 3A Jacket Material Black PVC
Test Voltage 250VAC - 300 VDC max. Conductor Size 18/3 or 20/3
Insulation Group VDC 0110 1/89 Class C Conductor Color Brn, Blue, (Blk), Grn/Yel
Clamping Voltage 24V 34V Nominal Cable OD 6.7mm
Clamping Voltage 110V 185V Bend Radius 10 X Cable OD
Connector Material Glass Reinforced Polypropylene Center Screw Depending on Connector
Protection Rating IP 65; IP 67 on Request Temperature Range -2° to +176° F
Contact Resistance < 4 mΩ