![](/html/95/9525/9525003bd687bcce8a8ed71128917243f519052f469d37a0b9d55ec6e1245103/bg1.png)
with UL94V-0 polyamide
insulating body
•
UL94V-0
•
universal mounting onto both PR/DIN and PR/3
type rails - according to IEC 60715 Std., “G32”
and “TH/35” types
•
CESI 01 ATEX 090 U Ex e certificate
, M2 / ,, 2 G D operating temperature range:
–40 ÷ +80 °C
•
CoC IEC Ex CES 09.0009U
•
when rail assemblies are to be manufactured for
potentially explosive environments (Ex e) please
refer to the instructions given on page A14
•
a
vailable in standard (beige RAL 1001 colour) or (Ex)
i “intrinsic safety” circuits (blue RAL 5015
Ex e II
colour)
(*): 150 A factory wiring only
beige version
(Ex)i version
CBD.50
Cat. No. CB710
CBD.50 (Ex)i
Cat. No. CBX72
CBD.70
CBD.70 (Ex)i
TECHNICAL CHARACTERISTICS
function / type
rated cross-section (mm2)
connecting capacity
flexible (mm2)
rigid (mm2)
max. flexible with ferrule (mm2)-ferrule type
rated voltage / rated current / gauge co
rated voltage / rated current / AWG
(Ex e) rated voltage / (V) 630 V / 630 V 630 V / 630 V
rated impulse withstand voltage / pollution degree
insulation stripping length (mm)
tightening torque value (test / max) (Nm)
height / width / thickness
height / width / thickness
height / width / thickness
nf. to IEC 60947-7-1
/ tightening torque value UL
TH/35 7,5 mm
TH/35 15 mm
G32
APPROVALS
ACCESSORIES
End sections beige
Permanent cross connection (same, Ex e version)
Rated current carrying capacity of jumper
Switchable cross connection
Multiple common bar 250 mm
Shunting screw and sleeve (same, Ex e version)
Coloured partition red, green, white
Cross connection barrier red
Test plug socket
Test plug
Modular test plug
End section for modular test plug
Numbering strip
Warning plate on adjacent terminal blocks
Cover for cross-connection
Marking tag printed or blank
End bracket
Mounting rail
according to IEC 60715 Std.
(same, Ex e version)
(A)
feed-through feed-through
50 70
1,5 ÷ 50
1 ÷ 70
50 - WP500/40
800 V / 150 A / B9
600 V / 130 A (*) / 16-1 AWG / 33,2 lb.in.
8 KV / 3 8 KV / 3
22 26
2,5 / 5 3 / 8
62 / 57 / 18 71 / 62 / 20,5
70 / 57 / 18 79 / 62 / 20,5
66 / 57 / 18 75 / 62 / 20,5
LV 27/1
Type Cat. No. Type Cat. No.
CB50/PT
blue
CB50/PT (Ex)i
POF/07 (PFX/07)
150 / (150) 192 / (155)
POS/77 POS77 POS/08 POS08
PMP/07
CPM/07 (CPX/07)
DFU/5 DU05.. DFU/6 DU06..
DFM/700 DF700 DFM/700 DF700
PSD/C PD003 PSD/C PD003
SDD/2 DD002 SDD/2 DD002
- -
- -
- -
TUM/07 on 3 and on 4 TUM07
-
PRP/8
CNU/8/51 NU0851
CSC CS...
BTU for PR/DIN and PR/3 BT005
BT/DIN/PO for PR/DIN only BT001
BT/3-BTO for PR/3 only BT003-BT007
PR/DIN/AC of steel PR001
PR/DIN/AS same with slots PR004
PR/DIN/AL
PR/3/AC of steel PR003
PR/3/AS same with slots PR005
Distribuzione
DV 27/1
CB711
CBX73
POF07 (PFX07)
PMP07
CPM07 (CPX07)
PRP08
of aluminium PR002
1,5 ÷ 95
1 ÷ 95
-
800 V / 192 A / B11
600 V / 220 A / 12 - 4/0 AWG / 50 lb. in.
LV 27/1
CB70/PT
CB70/PT (Ex)i
POF/08 (PFX/08)
PMP/08
CPM/08 (CPX/08)
TUM/08 on 3 and on 4 TUM08
-
PRP/8
CNU/8/51 NU0851
CSC CS...
BTU for PR/DIN and PR/3 BT005
BT/DIN/PO for PR/DIN only BT001
BT/3-BTO for PR/3 only BT003-BT007
PR/DIN/AC
PR/DIN/AS same with slots PR004
PR/DIN/AL
PR/3/AC of steel PR003
PR/3/AS same with slots PR005
Cat. No. CB810
Cat. No. CBX82
Distribuzione
DV 27/1
CB811
CBX83
POF08 (PFX08)
PMP08
CPM08 (CPX08)
PRP08
of steel PR001
of aluminium PR002