ASI-Automation Systems Interconnect CBD Series Data Sheet

CBD Series
with UL94V-0 polyamide insulating body
UL94V-0
universal mounting onto both PR/DIN and PR/3 type rails - according to IEC 60715 Std., “G32” and “TH/35” types
CESI 01 ATEX 090 U Ex e certificate , M2 / ,, 2 G D operating temperature range: –40 ÷ +80 °C
CoC IEC Ex CES 09.0009U
when rail assemblies are to be manufactured for potentially explosive environments (Ex e) please refer to the instructions given on page A14
a
vailable in standard (beige RAL 1001 colour) or (Ex)
i “intrinsic safety” circuits (blue RAL 5015
Ex e II
colour)
(*): 150 A factory wiring only
beige version
(Ex)i version
CBD.50
Cat. No. CB710
CBD.50 (Ex)i
Cat. No. CBX72
CBD.70
CBD.70 (Ex)i
TECHNICAL CHARACTERISTICS
function / type rated cross-section (mm2) connecting capacity
flexible (mm2) rigid (mm2)
max. flexible with ferrule (mm2)-ferrule type rated voltage / rated current / gauge co rated voltage / rated current / AWG (Ex e) rated voltage / (V) 630 V / 630 V 630 V / 630 V rated impulse withstand voltage / pollution degree insulation stripping length (mm) tightening torque value (test / max) (Nm) height / width / thickness height / width / thickness height / width / thickness
nf. to IEC 60947-7-1
/ tightening torque value UL
TH/35 7,5 mm TH/35 15 mm G32
APPROVALS
ACCESSORIES
End sections beige
Permanent cross connection (same, Ex e version) Rated current carrying capacity of jumper Switchable cross connection Multiple common bar 250 mm Shunting screw and sleeve (same, Ex e version) Coloured partition red, green, white Cross connection barrier red Test plug socket Test plug Modular test plug End section for modular test plug Numbering strip Warning plate on adjacent terminal blocks
Cover for cross-connection Marking tag printed or blank
End bracket
Mounting rail according to IEC 60715 Std.
(same, Ex e version)
(A)
feed-through feed-through 50 70
1,5 ÷ 50 1 ÷ 70 50 - WP500/40 800 V / 150 A / B9 600 V / 130 A (*) / 16-1 AWG / 33,2 lb.in.
8 KV / 3 8 KV / 3 22 26 2,5 / 5 3 / 8 62 / 57 / 18 71 / 62 / 20,5 70 / 57 / 18 79 / 62 / 20,5 66 / 57 / 18 75 / 62 / 20,5
LV 27/1
Type Cat. No. Type Cat. No.
CB50/PT
blue
CB50/PT (Ex)i POF/07 (PFX/07) 150 / (150) 192 / (155) POS/77 POS77 POS/08 POS08 PMP/07 CPM/07 (CPX/07) DFU/5 DU05.. DFU/6 DU06.. DFM/700 DF700 DFM/700 DF700 PSD/C PD003 PSD/C PD003 SDD/2 DD002 SDD/2 DD002
- -
- -
- -
TUM/07 on 3 and on 4 TUM07
-
PRP/8 CNU/8/51 NU0851 CSC CS... BTU for PR/DIN and PR/3 BT005 BT/DIN/PO for PR/DIN only BT001 BT/3-BTO for PR/3 only BT003-BT007 PR/DIN/AC of steel PR001 PR/DIN/AS same with slots PR004 PR/DIN/AL PR/3/AC of steel PR003 PR/3/AS same with slots PR005
Distribuzione
DV 27/1
CB711 CBX73
POF07 (PFX07)
PMP07
CPM07 (CPX07)
PRP08
of aluminium PR002
1,5 ÷ 95 1 ÷ 95
-
800 V / 192 A / B11 600 V / 220 A / 12 - 4/0 AWG / 50 lb. in.
LV 27/1
CB70/PT CB70/PT (Ex)i POF/08 (PFX/08)
PMP/08 CPM/08 (CPX/08)
TUM/08 on 3 and on 4 TUM08
-
PRP/8 CNU/8/51 NU0851 CSC CS... BTU for PR/DIN and PR/3 BT005 BT/DIN/PO for PR/DIN only BT001 BT/3-BTO for PR/3 only BT003-BT007 PR/DIN/AC PR/DIN/AS same with slots PR004 PR/DIN/AL PR/3/AC of steel PR003 PR/3/AS same with slots PR005
Cat. No. CB810
Cat. No. CBX82
Distribuzione
DV 27/1
CB811 CBX83
POF08 (PFX08)
PMP08
CPM08 (CPX08)
PRP08
of steel PR001
of aluminium PR002
Loading...