ASI 0195 Operating Instructions Manual

1
PLEASE READ CAREFULLY THROUGH THIS MANUAL BEFORE USING THE PRODUCT. OBSERVING ALL SAFETY INFORMATION, WARNINGS AND CAUTIONS WILL PROTECT YOURSELF AND OTHERS. PLEASE KEEP INSTRUCTIONS FOR FUTURE REFERENCE.
Operating Instructions and Parts Manual
Hand Dryer
Surface-mount e d A DA- c o m p l iant hand dr yer
441 Saw Mi ll R iv er Roa d, Yonke rs, NY 10701 (91 4) 4 76 -9 00 0
MODEL # 0195
3-15/16 "
(100 mm)
11-7/32"
(285 mm)
15-5/64"
(383 mm)
ITEM CATEGORY
Operating Voltage Warm Air Volume Output Warm Air Temp Output Motor Type Motor Thermal Protection Heater Element Heater Thermal Protection Drying Time Circuit Operation Sensor Range Timing Protection Timing Duration Cover Type Cover Finish Net Weight Shipping Weight Unit Size ADAAG Compliance
PERFORMANCE DATA
TECHNICAL SPECIFICATIONS
Input (Vac)
115
120
208
220
230
240
Motor Heater
Vac
115
120
104
110
115
120
Inrush A(W)
2.16 (248)
2.25 (270)
1.95 (203)
2.07 (227)
2.16 (248)
2.25 (270)
Operating A (W)
1.44 (165)
1.5 (180)
1.3 (135)
1.38 (151)
1.44 (165)
1.5 (180)
Inrush / Operating A(W)
16.2 (1857)
16.8 (2020)
14.6 (1519)
15.4 (1700)
16.2 (1857)
16.8 (2020)
Vac
115
120
104
110
115
120
Total
Inrush A(W)
18.4 (2105)
19 (2290)
16.6 (1722)
17.5 (1927)
18.4 (2105)
19 (2290)
Operating A(W)
17.6 (2022)
18.3 (2200)
15.9 (1654)
16.8 (1851)
17.6 (2022)
18.3 (2200)
www.americanspecialties.com
05072049
100-240 VAC, 50/60 Hz, 2.2 kW
185 CFM {314.5 /h} 149°F {65°C}at ambient T = 77°F {25°C} ¼ HP, 7.5 krpm, Brush Type, Dual Ball Bearings Auto Resetting Thermostat turns unit off at 221°F, {105°C} 2020W @ 120 VAC, Nichrome 7.12 Ω Auto Resetting Thermostat turns unit off at 149°F, {65°C}, Resets at 122°F {50°C} Less than 25 seconds Infrared Automatic, self adjusting 2" to 13" [51 mm to 330 mm], adjustable; standard 7" [18 cm ± 2 cm] 2 minutes auto shut off 2 seconds delayed turn off after last sensor read ¼” (6 mm) thick Cast Iron Porcelain Enamel 24 lbs [10.9 kg]
24.9 lbs [11.3 kg] 15-5/64" W x 11-7/32" H x 3-15/16" D [383 mm x 285 mm x 100 mm] Less Than 4" [102 mm] Projection
3
m
Patented No. D 543,661 S
2
Operating Instructions and Parts Manual
Hand Dryer
www.americanspecialties.com
05072049
Su r fac e -m o u nt e d ADA-co m pl i ant h and d r yer
Installation Kit Included (find in carton)
General safety information:
Installation
-- NOTE: Do not install dryer over washbasin --
Disconnect power at the service breaker before installing or servicing.
NOT FOR HOUSEHOLD USE - MAY CASE BURNS. " IMPROPRE A L'USAGE DOMESTIQUE - PUET OCCASIONNER."
This product is intended for installation by a qualified service person. Use AWG NO. 12 solid conductor for wiring.
All units must be supplied with a 3-wire service. The ground wire must be connected to the dryer's backplate.
Failure to properly ground unit could result in severe electrical shock and/or death.
1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark locations of 4 mounting holes and wire service entry at knockout (KO) location. Note: For two or more dryers, dryers should be no closer than 24 inches (610 mm) on center.
3. Remove and retain 2 cover screws and cover.
4. For in-wall (concealed) power supply - Provide supply wire to KO location according to local code and attach securely to chassis at KO with appropriate strain relief connector (not supplied).
5. Attach dryer to wall. For wood wall/studs use ¯1/4 inch (6 mm) screws at length that will ensure 1 inch (25 mm) min. stud penetration. For masonry walls use expansion bolts or anchors for ¯1/4 inch (6 mm) screws to ensure penetration 1/4 inch (6 mm) deeper than anchor. Shim if necessary to ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal block where indicated and connect ground wire to base plate with ground screw (Connections: A. Connect the live wire (colored Brown or Black) to the terminal block marked "L1". B. Connect the neutral wire (colored White or Grey) or connect the second live wire (colored Red or Orange) to the terminal block marked "N/L2". C. Connect the ground wire (colored green or green and yellow or bare conductor) to the terminal block marked " " or to the green screw marked " "). Colors of live and neutral wires depend on voltage of supply service and requirements of Building and Electrical Code having jurisdiction.
7. Replace cover. Do not over-tighten screws.
8. Switch on circuit breaker and test unit operation.
9. Complete and mail registration reply postcard.
1. Self-Threading screws (1/4" x 1-1/2") x 4 pcs
2. Metal Washer (3/8" x 7/8"x 1/16") x 4 pcs
3. Nylon bushing x 4 pcs (5/32" ) x 1 pc4. Security hex wrench
- IMPORTANT - READ COMPLETELY BEFORE STARTING INSTALLATION PROCEDURE