Type ST-2A Digital Indicator
FEATURES
• Measurement of pressure, temperature, voltage and current
• Accuracy ratings of ±0.1, 0.05% and
0.025% F.S. (pressure)
• Pressure ranges from 0.25 inches of
water to 10,000 psi
• Interchangeable pressure and temper-
ature modules
• Multiple engineering units
• Temperature measurement with most
common RTDs and thermocouples
• Programmable damping
• Tare capability
• Display hold
• RS232 two-way communications
• Standard N.I.S.T.-traceable certificate
of calibration
The ST-2A is the perfect bench compan-
ion product to the Ashcroft
®
ATE-100 field
handheld calibrator. This bench top (or
panel mounting) package shares the
same pressure and temperature modules
and interfaces with the same software
packages as the Ashcroft ATE-100. An
intuitive menu- driven user interface puts
all of the ST-2A’s power at the simple
press of a key. It uses the AQS (Ashcroft
Quick-Select™) modular sensor system
to provide the ultimate in measurement
flexibility.
Now you can purchase a calibration
system to serve your field and bench
mounting requirements while enjoying the
significant cost savings gained through
the availability of common pressure modules and software.
SPECIFICATIONS
Standard Display: Alphanumeric LCD, 0.37-inch
height, 2 lines, 16 characters/line
Optional Display: Backlit LCD alphanumeric with 2
lines and 16 characters/line
Display Resolution: ±0.002% of span, 60,000
counts (max)
Display Update Rate: 130ms (nominal) with one
sensor installed
Engineering Units: psi, in.H
mbar, kPa, MPa, mmHg, cmH2O, mmH
2
kgcm
and any single user-programmable
engineering unit
Damping: Programmable averaging from zero
through 16 consecutive readings
Standard Operating Range: 32° to 120°F (0 to
49°C)
Compensated Range: 20° to 120°F (–7° to +49°C)
Reference Temperature: 70 ±3°F
Standard Temperature Effect: ±0.004% of span per
degree Fahrenheit over the compensated range
Optional: AQS-2 Quick-Select modules are available
calibrated to maintain rated accuracy over the
20° to 120°F (–7° to +49°C) compensated
temperature range.
Storage Limits: –4°F to +158°F (–20° to +70°C)
Electrical Sourcing Specification: 24 Vdc at 25mA
Electrical Measurement Specification:
Input (volts)
0/10 Vdc ±0.025% F.S.
0/30 Vdc ±0.10% F.S.
Input (mA)
0/20mA ±0.03% F.S
Temperature Effects Electrical Measurement:
±0.001% of span per °F over the compensated
range
Weight: ST-2A Base unit: 3.0 lb (1.4 kg)
Housing: Molded, high-impact ABS case
Electrical Connections: Standard banana jacks
Optional Battery Power Supply: 5 “AA” nicads with
built-in charger or 5 “AA” alkaline (nonrechargeable)
External Power Supply: AC adaptor 9 Vdc, 500mA
Portable Operation: 20 hours with optional back-
light off, 2 hours with backlight on
Warm-up: 5 minutes for rated accuracy (max-
imum), 30 minutes for complete stability
RS232 Serial Interface: with 9-pin D type at 300,
1200, 2400, 9600 baud.
Field Calibration: Calibration module and proper
pressure and electrical standards are required.
Optional Data Logging Capacity:
Standard measurements:
Date/time stamped measurements:
Provides prompts for storage of calibration
history information, including instrument tags,
As Found/As Left data and corresponding
ambient temperature
O, in.Hg, ftSW, bar,
2
Accuracy
Accuracy
714 records
O and
2
384 records
BULLETIN ST-2A
All specifications are subje ct to change without notice.
All sales subject to standard terms and conditions.
© Ashcro ft Inc. 2008 11/08
Ashcroft Inc., 250 Eas t Main Street, Stratfo rd, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: info@ ashc roft .com • www.ashcroft.com
![](/html/42/4248/42486dabe81f48aeb065b993c96b0cbdb3e30d4f712f0ebfa3d1ab61caa611a1/bg2.png)
0.93
0.97
1.44
3.47
4.00
9.24
0.56
6.74
6.33
3.31
1.511.25
1.10
Type ST-2A Digital Indicator
STANDARD RANGES
AQS-2 AQS-1
psi ˝H2O
(gauge & (gauge/ Other Engineering Units**
absolute differential
pressure) pressure)
100
150
200
250
300
500
600
1000
1500
2000
2500
3000
5000
6000
7500
10,000
vacuum
compound
±10
±15
–15/+30
–15/+60
* Non-isolated, for clean dry gas only
5
0.25*
10
0.5*
15
1.0*
20
2.0*
25
3.0*
30
5.0*
50
10*
60
15*
25*
50*
100*
150*
200*
**Note: Engineering units
psi
in. H2O
in. Hg
ftSW
Bar
mBar
kPa
mPa
mmHg
cmH2O
mmH2O
2
kg/cm
User Selectable
identified above are
accessible through the
unit select feature. However, readout will default
to the primary unit of
measure on start-up.
Sensor modules scaled in
primary units other than
O (AQS-1) or psi
in. H
2
(AQS-2) are also available.
Consult factory.
5
10
15
±0.125*
±5
±0.25*
±0.5*
±1.0*
±1.5*
±2.5*
±5.0*
±7.5*
±12.5*
±25*
±50*
±75*