Ashcroft PPSN7HB25XC8 60#, PPAN7HB06XC8 3000#, PPSN7HB25XC8 100IW, PPSN7HB25XC8 30IMV/15#, PPSN7HB06XC8 1000# User manual

...
Page 1
Installation and Maintenance Instructions for
1
.06
(
27)
2.30 (58)
0.38 (10)
4.75
(
121)
3
.88
(
99)
5.50
(
140)
5 .0 0
(
12 7)
Ø
0 .3 1X 4 HOLES
3
/4 NPT
T
YP
Ø
3. 90
(
99)
4. 70
(
119 )
2.90 (
7 4 )
3.06 (7 8 )
7
.7 2
1
/4 NPT PORT
8
.0 8
1
/2 NPT MALE &
1/4 NPT FEMALE
(205 )
(
8)
(19 6)
1
.06
(
27)
2
.30
(
58)
0.38 (
10)
4
.75
(
121)
3
.88
(99)
5
.50
(140)
5.00
(127)
Ø0.3 1X4 HOLES
(8)
3
/4 NPT
TYP
Ø
3 .9 0
(9 9 )
4. 70
(119 )
2
. 9 0
(
74 )
3
. 06
(
78)
Ø
5 .12
(13 0)
5
. 32
(
13 5 )
8. 3 6
(
212 )
1
/4 NPT PORT
TERMINAL BLOCK SWITCH A
TERMINAL BLOCK SWITCH B
2
1
3
2
1
3
NC
NO
C
NC
NO
C
ASHCROFT®P-Series Snap Action Switches for Pressure Control
psi Ranges
H
O Ranges
2
N4 – 5.0 lb. (2.3) N7 – 5.6 lb. (2.5)
STANDARD RANGES
15, 30, 60, 100, 200, 400, 600 psi 1000, 2000, 3000 psi
N4 – 5.7 lb. (2.6) N7 – 6.3 lb. (2.9)
STANDARD RANGES
30, 60, 100, 150 ˝H
O
2
30˝Hg vac.-0 psi 30˝Hg vac.-15 psi
INTRODUCTION
The Ashcroft pressure control is a precision device which fea­tures a snap action switch.Fix
The “P” Series Ashcroft snap action pressure switch is available in both standard NEMA~ and explosion-proof NEMA 7 & 9 con­figurations.The enclosure is an epoxy coated aluminum casting.
INSTALLATION
This control is a precision instrument and should never be left with inter covers are in place and conduit openings are sealed.
MOUNTING
Four holes in the bracket supplied are used in surface mounting of the control. Location of these holes is shown on the general dimension dr available. Mount on a vibration free surface or pipe.When tighten-
Find Quality Products Online at: sales@GlobalTestSupply.com
nal components exposed.During installation insure that
awings.An optional pipe mounting bracket is also
www.GlobalTestSupply.com
ing control to pressure line, always use the wrench flats or hex on the pressure connection. Never tighten by twisting the case.
ELECTRICAL CONNECTION
Remove top cover, cover unscrews (CCW).
On all units except one with terminal blocks-wire directly to the
switch according to circuit requirements.
Units with terminal blocks-wire directly to terminal blocks as required.Terminals are marked common, norm open and norm closed.
Page 2
Installation and Maintenance Instructions for
A
B
0 20 40 60
0 20 40 60
ASHCROFT®P-Series Snap Action Switches for Pressure Control
CONDUIT CONNECTIONS
3
Two
4 NPT holes are provided, one fitted with a plug, the other
with a cap.It is recommended that Teflon tape or other sealant be used on conduit bushing or plug threads to ensure integrity of the enclosure. NEMA 7 & 9 enclosures require proper conduit seals and breathers as per the National Electrical Code.
SETPOINT ADJUSTMENTS Series PP-S Single Switc
by two screws. For setpoint adjustment to within + 1% of nomi­nal range, use a suitable reference such as an Ashcroft Duragauge or test gauge.Monitor switch with a suitable pilot light or meter.Pressur ize the system to the required setpoint and turn the adjusting wheel until the switch changes mode. When the setpoint has been achieved, raise and lower the pres­sure to insure that the setpoint is correct.
h – Remo
ve front cover, held in place
Series PP-D Dual Switch – Remo by two screws.There are two range adjusting wheels.The adjusting wheel on the left (labeled A) controls the left switch, the adjusting wheel on the right (labeled B) controls the right switch.The switches are set independently.
NOTE:The units are calibrated at the factory such that for proper
oper
ation switch B setpoint must be set higher than
switch A setpoint.
For setpoint adjustment to within ±1% of nominal range mount the switch on a calibration stand, and use a suitable reference such as an Ashcroft Duragauge or test gauge.Monitor switch with a suitable pilot light or meter.
Pressurize the system to the required setpoint and turn the adjusting wheel until the switch changes mode.When the set­point has been achieved, raise and lower the pressure to insure that the setpoint is correct.This must be done for both setpoint A and setpoint B.
Series PP-A Adjustable Deadband SwItch – Remove front co
ver, held in place by two screws.The adjusting wheel labeled A controls the resetpoint of the switch.The adjusting wheel labeled B controls the setpoint of the switch.
Note: The units are calibrated at the factory such that for proper
oper
ation setpoint B is always higher than resetpoint A.
For accurate setpoint adjustment, mount the switch on a calibra­tion stand, and use a suitable reference such as an Ashcroft Duragauge or Test Gauge. Monitor switch with a suitable pilot light or meter.Pressur ize the system to the required setpoint. Move adjusting wheel on spring B until switch changes mode. Then lower pressure to the resetpoint, move adjusting wheel on spring A until the switch changes mode.Raise and lower pres­sure to insure that setpoint is correct. Repeat as necessary.
ve front cover, held in place
Note: Since vacuum models are already abo
atmosphere, the Normally Open (NO) circuit will be closed as received.
ve setpoint at
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com