Ashcroft P Data sheet

Page 1
Data Sheet
P-Series Explosion Proof Pressure Switches
FEATURES
 Precision SPDT snap-acting micro switch  Setpoint adjustable from 15-100% of range  Single or dual adjustable set points  Fixed or adjustable deadband  Wide selection of switch elements  Fixed or adjustable deadband
TYPICAL USES
 Refineries  Chemical and Petrochemical Plants  Steel Mills  Water and Sewage Treatment Plants  Pumps, Compressors and Turbines  Boilers and Burners  Reverse Osmosis Systems and Filters
P-Series
Explosion-Proof Enclosure
P-Series
Explosion-Proof Enclosure Differential Pressure Switch
SPECIFICATIONS
Set Repeatability (Accuracy):
Switch Type: SPDT or 2 SPDT with independent setpoints
Setpoint: Single setpoint, fixed deadband
Deadband: Fixed or adjustable deadband Enclosure Ratings: NEMA 7 & 9, IP66
Enclosure Material: Epoxy coated aluminum Process Connection: ¼ NPT Female, ½ NPT Female,
Electrical Termination:
APPROVALS
Explosion Proof: UL, CSA
Standard: CRN
±1% of span (Additional setpoint shift of ±1% of range per 50°F from initial setpoint set at 70°F typical)
Single setpoint, adjustable deadband Dual independent setpoints, fixed deadband
¼ NPT Female and ½ NPT Male Combination
¾ NPT Female
CLASS I DIV 1 GROUPS B, C, & D CLASS II DIV 1 GROUPS E, F, & G
KEY BENEFITS
• Epoxy-coated aluminum enclosures provide added protection in harsh environments
• Dual chamber design provides safe setpoint adjustment even with power connected
• Designed for use in wide range of applications
• Easily configurable to meet your application requirements
• Hermetically sealed micro switches offer improved reliability and safety (UL Class I Div II approval)
WETTED COMPONENTS
Actuator Seal
Buna-N®, Teflon®, Viton®,
316L SS, or Monel
®
Pressure Switches
316L SS or Monel®
for psi ranges
Epoxy coated carbon
steel or 316L SS for
Process Connection:
Differential Switches
Nickel plated brass or
316L SS for psid ranges
Epoxy coated carbon
steel or 316L SS for
IW ranges
IWD ranges
All speci fications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. pseries_press_switch_ds1.0, Rev. A , 04/19
of 51
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 2
Data Sheet
P-Series Explosion Proof Pressure Switches
ORDERING CODE Example: PPSN7 G S 25
Enclosure – Pressure Switch
PPSN7 - Single setpoint, fixed deadband, N7-NEMA 7 & 9, IP66, explosion proof Div, 1 & 2
PPDN7 - Two independent adjustable setpoints, fixed deadband, N7-NEMA 7 & 9, IP66,
PPAN7 - Single setpoint, adjustable deadband, N7-NEMA 7 & 9, IP66, explosion proof Div, 1 & 2
Enclosure – Differential Pressure Switch
PDSN7 - Single setpoint, fixed deadband, N7-NEMA 7 & 9, IP66, explosion proof Div, 1 & 2
PDDN7 - Two independent adjustable setpoints, fixed deadband, N7-NEMA 7 & 9, IP66,
PDAN7 - Single setpoint, adjustable deadband, N7-NEMA 7 & 9, IP66, explosion proof Div, 1 & 2
Switch Elements For Single Setpoint with Adjustable Deadband - UL/CSA Listed
H - General purpose, 10A - 125/250 Vac. 1⁄2 A, 125Vdc, 1⁄4 A, 250Vdc
J - Hermetically sealed, general pupose - 11A, - 125/250 Vac, 5A, 30Vdc
Single/Dual Switch Setpoint with Fixed Deadband - UL/CSA Listed
C/CC - Heavy duty ac, 22A - 125/250 Vac
E/EE - Manual reset acutates on decreasing pressure 15A, 125/250 Vac 6A, 130 Vdc (no hazardous approval)
F/FF - Sealed environment proof, 15A - 125/250 Vac. (estimated dc rating - 4A, 28Vdc, not UL listed)
G/GG - General purpose, 15A - 125/250/480 Vac, 1⁄2 A - 125 Vdc, 1⁄4 A - 250 Vdc (not listed at 480 Vac) G
H/HH - General purpose, 10A - 125/250 Vac 10A, Vdc
J/JJ - Hermetically sealed switch, general purpose, 11A, 125/250 Vac, 5A, 30 Vdc
K/KK - Narrow deadband, 15A - 125/250 Vac. (estimated dc rating, 0.4A, 120 Vdc, not UL listed)
L/LL - Hermetically sealed switch, gold contacts, 1A - 125 Vac
M/MM - Low level (gold) contacts, 1A - 125 Vac
P/PP - Hermetically sealed AC - 5A, 125/250 Vac. (estimated dc rating - 2.5A, 28Vdc, not UL listed)
S/SS - Heavy duty dc, 10A - 125 Vac or dc, 1⁄8 HP - 125 Vac or dc.
U/UU - Manual reset actuates on increasing pressure 15A, 125/250 Vac, 6A, 130Vdc (no hazardous approval)
Y/YY - High temperature 300°F (148°C) ambient, 15A, 125/250 Vac
W/WW - Ammonia service - 5A, 125/250 Vac, 6A, 30 Vdc
Actuator Seal
B - Buna-N®-20°F to 150°F 0°F to 150°F
V - Viton
T - Teflon®-20°F to 150°F 0°F to 150°F
S - 316L SS -20°F to 150°F 20°F to 300°F
P - Monel®-20°F to 150°F 20°F to 300°F
Process Connections
25- 1⁄4 NPT Female 25
06- 1⁄4 NPT Female and 1⁄2 NPT Male combination
07- 1⁄2 NPT Female
Options - Select from Table 4 on page 4 (If choosing an option(s) must include an “X’’) X _ _
6B - Cleaned for oxygen service 6B
Pressure Range (select from pressure range tables on page 3)
100# - 100 psi 100#
explosion proof Div, 1 & 2
explosion proof Div, 1 & 2
Temperature Limits
Material Ambient Process
®
-20°F to 150°F 20°F to 300°F
Not available in vacuum, & inches of water ranges or pressures above 1,000 psi
Not available in vacuum, & inches of water ranges or pressures above 1,000 psi
PPSN7
S
X6B
100#
All speci fications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. pseries_press_switch_ds1.0, Rev. A , 04/19
of 52
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 3
Data Sheet
P-Series Explosion Proof Pressure Switches
TABLE 1 - PRESSURE/VACUUM RANGES Approximate Deadband Switch Element for Buna-N
See multiplier TABLE 3 for additional material multipliers
Switch Element
Vacuum
Nominal Ranges
Overpressure
Ratings
Proof
Minimum
psi
Burst psi
PPA PPS PPD
J, H G J, H K, F P GG JJ, HH KK, FF PP
®
Diaphragm
30IMV –760mmHg -100 kPa 250 400 7-26 3-5 3-6.5 1-2 1-2.5 3-5 4-6.5 1-2 1-2.5
Compound
30IMV/
Pressure
15#
–760mmHg/
1.0 kg/cm
2
-100 kPa 100 kPa
250 400
10-25
4-13
3-5 1-2
4-6
1-3.5
1-2
0.5-1
1-2.5
0.5-1.2
3-5 2-4
2.5-4.5
1.3
1-2
0.5-1
0.5-1.=2
30IW 750mmH2O 7.5 kPa 20 35 4-27 1.5-3.5 2-5 0.5-1 0.5-2 1.5-3.5 2-5 0.5-1 0.5-2
60IW 1,500mmH2O 15 kPa 20 35 5-54 1.5-3.5 2.5-5 0.5-1.3 1-2 1.5-3.5 2.5-5 0.5-1.3 1-2
100IW 2,500mmH2O 25 kPa 20 35 8.5-90 4-6 4-8.5 1-2 1-3 4-7 4-8.5 1-2 1-3
150IW 3,750mmH2O 37 kPa 20 35 18-135 5.0-11 10-18 1.5-3 2-6 8-14 10-18 1.5-3 2-6
15# 1.0 kg/cm2100 kPa 500 1,500 2.5-13 1-2 1-3 0.5-1 0.5-1.2 1-2 1-3 0.5-1 0.5-1.2
30# 2.0 kg/cm2200 kPa 500 1,500 3-26 1-2.5 2-4.5 0.5-1.5 0.5-1.5 1-2.5 2-4.5 0.5-1.5 0.5-1.5
60# 4.0 kg/cm2400 kPa 500 1,500 5-54 2-4 4-7 1-2 1-2.5 2-4 4-7 1-2 1-2.5
100# 7.0 kg/cm2700 kPa 1,000 3,000 10-90 5-7 5-10 1-2.5 2-4 5-7 5-10 1-2.5 2-4
200# 14 kg/cm21,400 kPa 1,000 3,000 20-180 10-15 10-18 1-4 5-8 10-20 15-35 3-6 5-8
400# 28 kg/cm22,800 kPa 2,400 3,000 45-360 16-30 16-45 4-8 5-15 16-30 16-45 4-8 5-15
600# 42 kg/cm24,200 kPa 2,400 3,000 75-540 16-50 20-75 5-15 6-25 16-50 20-75 5-15 6-25
1000# 70 kg/cm² 7,000 kPa 12,000 14,000 160-900 75-130 50-160 7-30 10-85 75-130 50-160 7-30 10-85
2000# 140 kg/cm² 14,000 kPa 12,000 14,000 350-1,800 150-200 150-350 20-50 25-110 15-200 150-350 20-50 25-110
3000# 210 kg/cm221,000 kPa 12,000 14,000 400-2,600 180-250 180-400 30-70 50-250 180-250 180-400 30-70 50-250
TABLE 2 - DIFFERENTIAL PRESSURE RANGES Approximate Deadband Switch Element for Buna-N
See multiplier TABLE 3 for additional material multipliers
Switch Element
Nominal Ranges
Differential Pressure
Overpressure
Ratings
Static
psi
Minimum Proof psi
PDA PDS PDD
J, H G J, H K, F P GG JJ, HH KK, FF PP
®
Diaphragm
30IWD –760mmHg 5.4 21.6 5.5-27 3-5 4-6.5 0.5-1 0.5-2 3-5 4-6.5 0.5-1 0.5-2
60IWD 1,500mmH2O 5.4 21.6 5.5-54 3-5 4.5-6.5 0.5-1.3 1-2 3.5 4-6.5 0.6-1.3 1-2
100IWD 2,500mmH2O 5.4 21.6 8.5-90 4-6 4.0-8.5 1-2 1-3 4-7 4-8.5 1-2 1-3
150IWD 3,750mmH2O 5.4 21.6 18-135 5-11 10-18 1.5-3 2-6 8-12 10-18 1.5-3 2-6
30#D 1.0 kg/cm² 500 1,500 2.5-13 1-2 1-3 0.5-1 0.5-1.2 1-2 1-3 0.5-1 0.5-1.2
60#D 2.0 kg/cm
100#D 7.0 kg/cm
200#D 14 kg/cm
400#D 28 kg/cm
2
2
2
2
500 2,000 6.5-54 1-2.5 2-4.5 1-1.5 1-1.5 1-2.5 2-4.5 0.5-1.5 0.5-1.5
1,000 4,000 10-90 5-7 5-10 1-2.5 2-4 5-7 5-10 1-2.5 2-4
1,000 4,000 20-180 10-15 10-18 1-4 5-8 10-20 10-18 3-6 5-8
1,000 8,000 45-360 16-30 16-45 4-8 5-15 16-30 16-45 4-8 5-15
TABLE 3 - DEADBAND MULTIPLIER TABLE
Diaphragm Material Multiply Notes
®
Buna-N
®
Viton
®
Teflon
316 SS 1.7
®
Monel
1.0
1.4
1.7
1.7
Multiplier table for additional
diaphragm materials
1-2.5
All speci fications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. pseries_press_switch_ds1.0, Rev. A , 04/19
of 53
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 4
Data Sheet
P-Series Explosion Proof Pressure Switches
TABLE 4 - OPTIONS
Pressure
Differential
Pressure
Code Description psi inH2O psid inH2O
Chained cover
CH
FP Fungus proofing
Factory adjusted setpoints (Supply static pressure
FS
for D/P switches)
Fire safe actuator
G9
High operating pressure for inH2O ranges
40 psi Static (Pressure and D ⁄ P)
HX
100 psi Proof (Pressure)
160 psi Proof (D ⁄ P)
JL ¾˝ to ½˝ Reducing bushing
K3 Terminal blocks
NH Tagging SS
PM ¾˝ Sealed conduit connection with 16˝ lead wires
TA
316 SS pressure connection for H2O ranges
UD 316 SS Pressure Connection for psid ranges
C8 CSA approval
6B Cleaned for oxygen service
FM FM Approval
HS High static operating pressure for psi range D/P
D2 Dual seal rating (must order with XC8 as well)
All speci fications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. pseries_press_switch_ds1.0, Rev. A , 04/19
of 54
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 5
4.70
4.70
[212]
4.70
[243]
PRESSURE
4.70
7.72
[205]
[196]
Data Sheet
P-Series Explosion Proof Pressure Switches
DIMENSIONS in [ ] are millimeters
For reference only, consult Ashcroft for specific dimensional drawings
PRESSURE SWITCH – PSI RANGES
5.00
8.08
[127]
Ø 0.31 X 4 HOLES
[8]
3.88 [99]
4.75
[121]
5.50
[140]
3/4 NPT TYP
1.06 [27]
2.30 [58]
0.38 [10]
½ NPT MALE & ¼ NPT FEMALE
DIFFERENTIAL PRESSURE SWITCH –
PSI DIFFERENTIAL RANGES
5.00
[127]
¾ NPT TYP
1.06 [27]
[119]
Ø 3.90
[99]
¼ NPT PORT
Ø 3.90
[99]
[119]
2.90 [74]
3.06 [78]
2.90 [74]
9.55
PRESSURE SWITCH –
INCHES OF WATER RANGES
5.00
[127]
Ø 0.31 X 4 HOLES
[8]
3.88 [99]
4.75
[121]
5.50
[140]
¾ NPT
TYP
1.06 [27]
2.30 [58]
0.38 [10]
Ø 3.90
[99]
Ø 5.12
[130]
5.32 [135]
[119]
DIFFERENTIAL PRESSURE SWITCH –
INCHES OF WATER RANGES
5.00
[127]
¾ NPT TYP
1.06 [27]
Ø 3.90
[99]
[119]
2.90 [74]
8.36
[212]
3.06 [78]
¼ NPT PORT
2.90 [74]
2.30 [58]
0.38 [10]
¼ NPT
FEMALE
LOW PRESSURE
PORT
¼ NPT
FEMALE
HIGH
PORT
Ø 0.31 X 4 HOLES
[8]
L
H
Ø 2.31
[59]
3.9
[99]
4.75
[121]
5.50
[140]
All speci fications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. pseries_press_switch_ds1.0, Rev. A , 04/19
1.55
[39]
3.06 [78]
ashcroft.com
info@ashcroft.com
1.800.328.8258
1.48 [38]
Ø 0.31
[8]
X 4 HOLES
3.88 [99]
4.75
[121]
5.50
[140]
2.30 [58]
0.38 [10]
¼ NPT LOW PRESSURE PORT
Ø
[130]
5.12
5.32
[135]
3.06 [78]
¼ NPT HIGH PRESSURE PORT
8.36
of 55