Ashcroft LPSN4HB25 30IMV/15#, LPDN4GGB25 15#, GPDN4GGB25 400#, LPDN4GGB25 100IW, LPAN4HB06 2000# User manual

...
Page 1
Installation and Maintenance Instructions
1 2 3
1 2 3
LEFT SWITCH
TERMINAL BLOCK
RIGHT SWITCH
TERMINAL BLOCK
SERVICE LEADS TOTHESE TERMINALS
NC
NO
C
2.64 (67)
4.78
(121)
0.25 (6)
2.26 (57)
2.50 (64)
5.68 (144)
1.60 (41)
2.10 (53)
1.86 (47)
0.38 (10)
4.13 (105)
4.17 (106)
3.50 (89)
3/4 NPTFEMALE
CONDUIT ADAPTER
X06VARIATION: 1/2 NPT MALE & 1/4 NPT FEMALE
2.64 (67)
4.78
(121)
3.50 (89)
Ø
5.12
( 1 30)
1.7 5
1/4 NPT FEMALE
5.68
( 1 44)
1. 6 0 ( 4 1)
2. 1 0 ( 5 3)
1. 8 6 ( 4 7)
0.38 ( 1 0 )
4.17
( 1 0 6)
4.53
( 1 15 )
3. 4 8 ( 8 8 )
3/4 NPT FEMALE
CONDUIT ADAPTER
A
B
0 20 40 60
0 20 40 60
for ASHCROFT®G-Series Snap Action Switches for Pressure Control
psi Ranges
STANDARD RANGES
2.8 lbs. (1.3kg) 3.7 lbs. (1.7kg)
OPERATION
The ASHCROFT features a snap action switch.Fixed deadband is available with single or dual SPDT independently adjustable switches with various electrical ratings.Adjustable deadband is available with SPDT switch with various electrical ratings.Several wetted material constructions for compatibility with pressure media may be obtained.
Series GP-S switches have a fixed deadband which will be
within the limits noted on the nameplate.
Series GP-D switches may be set to operate simultaneously or up to 85 percent of the range apart. The deadband of each switch will be within the limits noted on the nameplate.
Series GP-A switches may be set to operate with any dead­band within the limits shown on the nameplate.
®
15, 20, 30, 60, 100, 200, 400, 600 psi
*1000,2000, 3000 psi
30˝Hg Vac.-0 psi
O Ranges
in.
H
2
STANDARD RANGES
30, 60, 100, 150 in.H
O Vac.-15˝H2O
15˝H
2
O
2
MOUNTING
The “G”
Series ASHCROFT®snap action pressure switch has a
NEMA-4X enclosure which is made of 316 stainless steel.
Two holes in the bracket supplied are used to surface mount the control. Location of these holes is shown on the general dimension drawings.An optional pipe mounting bracket is also available. Mount on a vibration free surface or pipe in any orien­tation.When tightening control to pressure line, always use the wrench flats or hex on the pressure connection.NEVER
TIGHTEN BY
CONDUIT CONNECTIONS
3
One
4 NPSM conduit adapter of 316 stainless steel is provided.
It is recommended that Teflon tape or other sealant be used on conduit bushings or plug threads to ensure integrity of the enclosure.
ELECTRICAL CONNECTION
Remov
On all units except one with terminal blocks – wire directly to the switch according to circuit requirements.Units with terminal blocks – wire directly to terminal blocks as required.Terminals are marked common (C), normally open (NO) and normally closed (NC).
Find Quality Products Online at: sales@GlobalTestSupply.com
TWISTING THE CASE.
e cover, held in place by four screws.
www.GlobalTestSupply.com
SETPOINT ADJUSTMENTS
Setpoints are changed by means of the setpoint adjusters.The GP-S single s
witch has one adjuster and the GP-A adjustable deadband and GP-D dual switch each have two adjusters. On switches with two adjusters, the one on the left is referred to as “A” and the right one is referred to as “B”;see illustration. Setpoints can be adjusted from 20 to 100 percent of full range on increasing pressure.
Page 2
Installation and Maintenance Instructions for ASHCROFT®G-Series Snap Action Switches for Pressure Control
SERIES GP-S SINGLE SWITCH
Remove cover.For setpoint adjustment on either increasing or decreasing pressure to within ±1% of nominal r switch on a calibration stand and use a suitable reference such as an ASHCROFT with a light or meter.Pressurize the system to the required setpoint pressure.
If setpoint is on increasing pressure, turn adjuster so that switch operates (if common – normally closed circuit is being monitored light goes off). If setpoint is on decreasing pressure, turn adjuster so that switch resets (if common – normally closed circuit is being monitored light comes on).When the setpoint has been achieved, raise and lower the pressure to ensure that the setpoint is correct.
The dead band (difference between the operate and reset pressures) may be verified at this time to be between the values noted on the nameplate label.
SERIES GP-D DUAL SWITCH
Remove cover.For setpoint adjustment on either increasing or decreasing pressure to within ±1% of nominal range switch on a calibration stand and use a suitable reference such as an ASHCROFT with a light or meter.
Pressurize the system to the required higher setpoint pressure and turn adjuster “B” until the switch operates or resets as required. See discussion of increasing or decreasing pressure setpoints and deadband verification under Series GP-S Single Switch.When the setpoint has been achieved, raise and lower the pressure to ensure that the setpoint is correct.Then reduce system pressure to the required lower setpoint pressure and turn adjuster “A” until the switch operates or resets as required. Verify this setpoint by raising and lowering pressure.Now increase system pressure to higher setpoint and make final adjustment on “B.”
®
Duragauge or test gauge.Monitor switch
®
Duragauge or test gauge.Monitor switch
ange, mount the
, mount the
SERIES GP-A ADJUSTABLE DEADBAND SWITCH
Remove cover.Adjuster “B” controls the operating point of the s
witch on increasing pressure. Adjuster “A” controls the re-
setpoint of the switch on decreasing pressure.
For accurate setpoint adjustment, mount the switch on a calibration stand and use a suitable reference such as an ASHCROFT light or meter.Pressurize the system to the required setpoint pressure.Tur n adjuster “B” until switch operates.Then lower pressure to the re-setpoint, turn adjuster “A” until the switch resets. Now increase pressure to the operating point and make final adjustment on “B.” Raise and lower pressure to ensure that the setpoint and re-setpoint are correct.
SOME PRECAUTIONS TO OBSERVE
Do not loosen the screws holding the precision switch element(s) or mounting br
Nameplate PROOF pressure should not be exceeded. Inter
mittent operation up to proof pressure is permissible,
however, some change of setpoint may be noted.
Operation and correct setpoint actuation should be routinely tested.
Note – Since v
®
Duragauge or test gauge.Monitor switch with a
acket in place.
acuum models are already above setpoint at atmosphere, the Normally Open (NO) circuit will be closed as received.