Ashcroft G3 Specifications

Model G3 Pressure Transducer
TOTAL ERROR BAND (TEB)
Error limits of all points (0-100% of range)
Error (% of span)
Ambient Temperature (C)
-60 -40 -20 0 20 40 60 80 100 120 140
2.0%
1.5%
1.0%
0.5%
0.0%
-0.5%
-1.0%
-1.5%
-2.0%
Pos Error Limit
Neg Error Limit
Deutsch
Connection
DIN43650
Connection
etri-Pack
M Connection
LOOK FOR THESE AGENCY
MARKS ON OUR PRODUCTS
BULLETIN G3
APPLICATONS
The G3 pressure transducer combines performance with value to meet the demanding needs of the original equip­ment manufacturer in applications
ound in:
f
• Railroad/Transportation
• Compressor Control
• HVAC and Refrigeration
• Agricultural Implements
• Process Automation and Control
• Hydraulic & Pneumatic Sensing
• Pump Monitoring
FEATURES
• 1.5% Total Error Band Accuracy
• Broad Temperature Capability
• All-welded 316L SS Wetted Parts
• High EMI/RFI rating
• Ranges vacuum through 300 psi
• Up to IP 67 Ingress rating
• Diagnostic rails
The Ashcroft®Type G3†pressure transducer has been specifically designed with the high volume OEM in mind.
The Ashcroft
®
Type G3 pressure transducer combines a high stability isolated piezoresistive sensor with our proven ASIC technology to pro­vide a highly accurate and repeatable transduc­er for both gauge and absolute pressure ranges. Calibration via digital compensation results in an extremely accurate instrument over a wide temperature range. The G3 design is well suited for demanding, high cycle applications.
The circuitry is held within an internal cage
and housed in an enclosure of reinforced Nylon.
All specifica tions are subject to change witho ut notice. All sales subject to standard terms a nd conditions. © Ashcroft Inc . 2015 11 /15
ERFORMANCE SPECIFICATIONS
P
Ref. Condition 21°C ±1°C (72°F ±2°F)
Accuracy:
Total Error Band includes combined effects of temper­ature, non-linearity (Terminal Point Method), hysteresis, non repeatabilty, zero offset and span setting errors
±1.5% of Span: From –20 to 85ºC (–4 to 185ºF) ±2.0% of Span: From –40 to –20ºC (–40 to –4ºF)
±2.0% of Span: From 85 to 125ºC (185 to 257ºF) Note: Static accuracy ±0.50% of span BFSL (Best Fit
Straight Line Method); includes non-linearity, hysteresis and non-repeatable effects at reference temperature 72°F (21°C)
Stability: Less than ±0.25% span/year Durability: Tested to 10 million cycles
ENVIRONMENTAL SPECIFICATIONS
Temperature:
Compensated –40 to 125°C (–40 to 257°F) Operating –40 to 125°C (–40 to 257°F) Storage –40 to 125°C (–40 to 257°F)
Humidity: 0 to 100% R.H., no effect
FUNCTIONAL SPECIFICATIONS
Select from several pressure ranges starting at vacuum and running through 300 psi gauge. Absolute, compound (vacuum & pressure) ranges are also available, see “To Order” on back.
Overpressure (F.S.): Proof Burst
200 psi & below 200% F.S. 500% F.S. 300 psi 200% F.S. 300% F.S. Vibration: Random vibration (20 g) over tempera­ture range (–40° to 125°C). Exceeds typical MIL. STD. requirements
Shock: 100gs, 6 ms Drop Test: Withstands 1 meter on concrete 3 axis Response Time: Less than 2 msec Warm-up Time: Less than 500 msec typical Position Effect: Less than ±0.01% span, typical
ELECTRICAL SPECIFICATIONS
Output Signals Available: Supply Voltage Output Excitation Current
0-5 Vdc, 3 wire 9-36 Vdc 5mA 0-10 Vdc, 3 wire 14-36 Vdc 5mA 1-5 Vdc, 3 wire 9-36 Vdc 4mA 1-6 Vdc, 3 wire 9-36 Vdc 4mA
0.5-4.5Vdc, 3 wire 9-36Vdc 4mA
Ratiometric Output:
0.5-4.5 Vdc, 3 wire 5 Vdc ±0.5 Vdc 3.5mA
Current Output:
4-20mA, 2 wire 9-36 Vdc
Reverse Polarity & Miswired Protected: Yes Insulation Breakdown Voltage: 100 Vac Insulation Resistance: Greater than 100 megohms
at 100 Vdc
CE Marked: Per DoC
EMC Directive 2004/108/EC
IEC/EN 61326-1:Edition 1.0 Industrial IEC/EN 61326-2-3:Edition 1.0 Annex BB Industrial
PED Directive
UL Recognized component per UL-61010-1, CSA
22.2 6101-1 Electrical Equipment for Measurement, Control and Laboratory use.
Ashcroft Inc., 250 East Main S treet, Str atford, CT 06614 USA Tel: 203-385-0648 • Fax: 20 3-385-0408 email: info@ash croft.com • www.ashcroft.com
1
0
4
0
9 (min)
3
6 (max)
Loop Supply Voltage (Vdc)
[LSV]
Power Supply Voltage vs. Loop Resistance
(
4-20mA ONLY)
Loop Resistance (R
L
-Ohms)
1400
1200
Model G3 Pressure Transducer
1.40
1.59
.23
.94
1.06
(27)
1.06
(27)
(36)
MINI HIRSCHMANN**
(24)
.
94
(24)
.71
(18)
2.24 (57)
(6)
2.05 (52)
.30 (8)
.23
(6)
(40)
Wire Length
3-PIN METRI-PACK*
AMP SUPERSEAL
DEUTSCH DT04-3P
DEUTSCH DTM04-3P
.23
Ø
.94
2.03
.45
1.02
1.06
.54
2.11
.56
.23
.94
.95
1.13
1.06
.44
.23
2
.04
.46
Ø
.94
1.06
.81
.67
Optional Mating Connector
Optional Mating Connector
Mates to Metri-Pack Connector Body 12065286
Mates to Hirschmann G4W1F Connector or Similar
Ø0.95
[Ø24.0]
1.69
[42.9]
1.74
[44.2]
2.60
[65.9]
0.23 [5.7]
1/4 NPT
Connection - PIN
1
2
3
V
out
Vs
-
Vs
+
3.992 TYP
Install height
Pin 1
Pin 2
Pin 3
Pin 4
PHYSICAL SPECIFICATIONS
Wetted Materials: 316L SS pressure connection and sensor diaphragm
Housing: 20% Glass Reinforced Nylon, Fire retardant to UL94 V1
Available Process Connections (Male):
See “How To Order” section below. For other connections consult factory.
Ingress Rating:
• IP67, NEMA 4X:
- Metri-Pack I50 series*
- Shielded cable
- Flying leads
- Deutsch DT Series DT04-3P
- Deutsch DTM Series DTM04-3P
- AMP Superseal
- M12 - Mates to Hirschmann 933 172-100 or similar
• IP65, NEMA 4X:
- Hirschmann G series**
- EN 175301-803, Form C (DIN 43650, Form C)
ELECTRICAL TERMINATION
See “How To Order” section below for electrical termination options.
DIMENSIONS
EN 175301-803, Form C
(DIN 43650, Form C)
M12 4-POLE PLUG
How To Order
Type
Configuration
(G3)
Accuracy
1.5% Total Error Band –20°C/+85°C
2.0% Total Error Band
–40°C/-20°C, 85/125°C
BULLETIN G3
G 3
05 = 0-5 Vdc 10 = 0-10 Vdc 15 = 1-5 Vdc 16 = 1-6 Vdc 42 = 4-20mA 45 = 0.5-4.5Vdc
9-36Vdc supply
RM= 0.5-4.5 Vdc
Pressure Connection
M011⁄8 NPT-male
1
M02
4 NPT-male
7
MEK
16-20 SAE-male
w/Buna-N O-ring
3
M38
8-24 SAE-male
w/Buna-N O-ring
9
MEV
16-18 SAE-male
w/Buna-N O-ring
3
M33
8-24 UNJF3A (w/37° cone seat)
7
M76
16-20 UNJF-3A (w/37° cone seat)
1
MS2
4-19 bsp male
1
MG2 G
4 B male
Consult factory for other connections
Output Signal
Ratio Metric to 5Vdc supply
VdcMIN = 9V + [0.022A X (RL]
RL= RS+ R RL= Loop Resistance (ohms) R R
W
= Sense Resistance (ohms)
S
= Wiring Resistance (ohms)
W
Electrical Termination
Deutsch DT Series DT04-3P DT = w/out mating conn. T2 = w/1m, 3´cable T3 = w/3m, 10´cable T1 = w/mating conn. cable
customer defined length
Deutsch DTM Series DTM04-3P DS = w/out mating conn. S2 = w/1m, 3´cable S3 = w/3m, 10´cable S1 = w/mating conn. cable
customer defined length
AMP Superseal AP = w/out mating conn. A2 = w/1m, 3´cable A3 = w/3m, 10´cable A1 = w/mating conn. cable
customer defined length
EN 175301-803, Form C (DIN 43650, Form C) DC = no mating conn. N1 = with mating conn. no cable N2 = mating conn. 3´cable N3 = mating conn. 10´cable N9 = mating conn. w/customer
specified length
Metri-Pack* GN = no mating conn. G2 = mating conn. 3´cable G3 = mating conn. 10´cable G1 = mating conn. w/customer
specified length
Hirschmann G Series** HM = no mating conn. M1 = with mating conn. no cable M2 = mating conn. 3´cable P9 = mating conn. w/customer
specified length
Flying Leads W2 = 3´flying leads W9 = customer specified length Shielded Cable F2 = 3´shielded cable F3 = 10´shielded cable P1 = customer specified length M12 – Mates to Hirschmann
933 172-100 or similar EW = w/o mating conn. E0 = w/mating conn. no cable E2 = w/mating conn. &
3´shielded cable
E1 = w/mating conn. &
customer defined length
**Metri-Pack is a trademark of Delphi Packard Electric Systems.
**Trademark of Richard Hirschmann of America, Inc.
***Not available in absolute pressure
All specifica tions are subject to change witho ut notice. All sales subject to standard terms a nd conditions. © Ashcroft Inc . 2015 11 /15
X 7
Pressure Ranges
psi Ranges 5# = 5 psi*** 15# = 15 psi 30# = 30 psi
50# = 50 psi 60# = 60 psi 100# = 100 psi 150# = 150 psi 200# = 200 psi 300# = 300 psi
Compound Ranges***
0#&vac = 0 psi/-14.7 psi 15#&vac = 15 psi/-14.7 psi 30#&vac = 30 psi/-14.7 psi 60#&vac = 60 psi/-14.7 psi
100#&vac = 100 psi/-14.7 psi 150#&vac = 150 psi/-14.7 psi 300#&vac = 300 psi/-14.7 psi
Measurement Type
G = Gauge Pressure
A = Absolute Pressure
-
Ashcroft Inc., 250 East Main S treet, Str atford, CT 06614 USA Tel: 203-385-0648 • Fax: 20 3-385-0408 email: info@ash croft.com • www.ashcroft.com
Optional
X-Variations
Consult Factory for
Available Options