Ashcroft CI Specifications

Data Sheet
CI Bimetal Thermometer
FEATURES
 Hermetically sealed case to prevent entry of
moisture, interior corrosion and coil freeze up
 Maxivision® dial for precise readings (minimize
parallax reading errors)
 Silicone dampened coil for reduction of pointer
 Customized dial printing
TYPICAL USES
 General Industrial  HVAC  Equipment Skids  Pharmaceutical / Biotech  Food and Beverages
CI Bimetal
2˝, 3˝, 5 ˝ dial sizes
SPECIFICATIONS
Accuracy: ±1% of span ASME B40.200 (B40.3 Grade A) Stem Length: 2½˝ to 24˝ Dial Sizes:
2˝, 3 ˝, 5˝
Dial Style: Maxivision®, black figures on white background Overtemperature
Limits:
Top of Range °F up to 250 251-550 551-1,000
(1)
Satisfactory for continuous service up to 800°F (425°C). Can be used for intermittent service from 800 to 1,000°F (425 to 500°C). Use Ashcroft Duratemp® thermometers for ranges above and below those listed above.
Max. Over Temperature 100% of span 50% of span
(1)
800°F
Process Connection: Plain, Pointed Stem, 1⁄4 NPT, 1⁄2 NPT Stem diameter: 0.250˝, .375˝
Case & Stem: 304 SS, Hermetically sealed Process Connection
Location:
2˝: Rear 3˝, 5˝: Lower, rear
Pointer: Black Window: Glass, Acrylic, Safety Glass
Approvals: RoHS
KEY BENEFITS
• Tamper resistant case
• NEMA 4X/IP66 protection
• 5-year limited warranty
• All welded stainless steel construction
MIN/MAX TEMPERATURE LIMITS
Version Ambient
Dry
-40°F to 200°F
(-40°C to 93°C)
All specifications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. ci_bimetal_ds1.0, Rev. A, 03/19
of 41
ashcroft.com
info@ashcroft.com
1.800.328.8258
Data Sheet
CI Bimetal Thermometer
ORDERING CODE Example:
Dial Size and Model
20CI - 2˝ Tamper resistant bimetal
30CI - 3˝ Tamper resistant bimetal 30CI
50CI - 5˝ Tamper resistant bimetal
Stem and Connection
40 - Plain - no connection
50 - Pointed stem - no connection (2˝ case only)
60 - 1⁄2 Fixed NPT for 3˝ & 5˝ but 1⁄4 fixed NPT for 2˝ 60
Connection Location
R - Rear connection R
L - Lower connection (Not available on 2˝ case)
Stem Length (Consult factory for custom or longer stem length)
025 - 21⁄2˝
040 - 4˝
060 - 6˝ 060
090 - 9˝
120 - 12˝
150 - 15˝
180 - 18˝
240 - 24˝
Temperature Ranges (see table on page 3)
0/200°F 0/200°F
Options - (if choosing an option(s) must include an “X’’)
CS - Dual scale
DM - Dial marking
NH - SS tag
PD - Plastic window
SG - Shatterproof glass SG
C4 - Individual calibration certification
S1 - Silicone free
3B - 3⁄8˝ stem diameter with 1⁄2 NPT
02 - 1⁄4 NPT (only available on rear connection)
30CI 60 R 060 0/200°F XSG
X_ _
All specifications are subject to change without notice.
All sales subject to s tandard terms and conditions.
©2019 Ashcroft Inc. ci_bimetal_ds1.0, Rev. A, 03/19
of 42
ashcroft.com
info@ashcroft.com
1.800.328.8258
Loading...