Ashcroft C-600A-04 Specifications

Data Sheet
C-600A-04 Duratemp
Thermometer
FEATURES
 Extreme resistance to shock and vibration  Exclusive movementless design eliminates wear and
increases product life
 No head or elevation error due to bulb placement  Maxivision® dial for precise readings
(minimize parallax reading errors)
 Multiple case styles with lower and back connections,
surface, or flush mounted
 Gas-operated molecular sieve
TYPICAL USES
 Offshore oil rigs  Chemical and petrochemical plants  Water and wastewater temperature control  Pulp and paper  Refineries  Power  General industrial  Equipment skids  HVAC  Pharmaceutical/biotech  Food and beverage
SPECIFICATIONS
Accuracy: ±1% of span
1
Size: 4
Range: -320°F/200°F to 400°F/1200°F
Over Range: 125% of span
Mounting & Connection: Lower, Rear, Surface or Flush
Bulb Size: 3˝ Long x
Bulb Style: 12˝ Bendable extension with
Line Length: 5ft to 80ft in standard increments Dial: Maxivision
Head/Elevation Error: None Hand Set: Stationary red hand set or Externally adjustable
Pointer: Black, aluminum Electric Contacts: High and low, double high, double low, off at low
2˝ or 6˝
(-200°C/100°C to 200°C/650°C)
3
8˝ O.D.
1
2 NPT union connection
Plain bulb with rigid extension no union Plain bulb with rigid extension 18˝ Bendable extension with 24˝ Bendable extension with
®
anti-parallax dial, black markings on
1
2 NPT union on armor
1
2 NPT union connection
1
2 NPT union connection
a white dial
red set hand
or high and on in-between
C-600A-04
41⁄2˝ & 6˝ dial size
KEY BENEFITS
• Phenolic case
• Snap ring for easy glass replacement or pointer adjustment
• Extremely versatile for use on many applications
• 5 year limited warranty
• Ideal for extreme process temperatures
THERMAL SYSTEM
Bulb/Bendable ext.
Material
316 SS
NON-WETTED COMPONENTS
Window Case Ring
Safety Glass,
Acrylic
Armor Material Capillary Material Connection Material
AISI 302 Spring
Armor
316 SS 303 SS
Phenolic 300 SS snap ring
TEMPERATURE LIMITS
Version Ambient
Dry -13°F (-25°C) to 160°F (71°C)
All specifications are subject to change without notice.
All sales subject to standard terms and conditions. ©2018 Ashcroft Inc. 600A-02_Duratemp_ds_(LR), Rev. B, 04/19
of 31
ashcroft.com
info@ashcroft.com
1.800.328.8258
Data Sheet
C-600A-04 Duratemp
ORDERING CODE Example:
Case Style
1
C-600A-04-C03 - 4
C-600A-04-C08 - 4
C-600A-04-C38 - 4
C-600A-04-C16 - 6˝ Case size, 300 SS snap ring, surface mount, lower conn.
C-600A-04-C42 - 6˝ Case size, 300 SS snap ring, flush mount, rear conn.
Bulb Style (Note 1)
B01 - 12˝ Bendable extension with B03 - Plain bulb with rigid extension, no union B08 - Plain bulb with rigid extension, B17 - 18˝ Bendable extension with B18 - 24˝ Bendable extension with
Armor Style
A1 - SS spring A1
Line Length (Capillary length is measured from bottom of case to top of bulb extension)
L01 - 5´ L01 L03 - 10´ L07 - 20´ L09 - 30´ L13 - 50´ L19 - 80´
Ranges (coding example, see range table on page 3 for all standard ranges)
AB - –320/200°F AB
Options (If choosing an option(s) must include an “X”)
CS - Dual scale DM - Dial marking ED - High and low electric contacts EE - Double high electric contacts EF - Double low electric contacts EG - Electric contacts off at low or high and on in-between EO - Externally adjustable red set hand EP - Externally adjustable maximum pointer EQ - Externally adjustable minimum pointer NH - SS tag NH PD - Acrylic window SG - Safety glass SH - Stationary red set hand
2 Case size, 300 SS snap ring, surface mount, lower conn. C-600A-04-C03
1
2˝ Case size, 300 SS snap ring, surface mount, rear conn.
1
2˝ Case size, 300 SS snap ring, flush mount, rear conn.
Thermometer
C-600A-04-C03
1
2 NPT union connection B01
1
2 NPT union on armor
1
2 NPT union connection
1
2 NPT union connection
B01 A1 L01 AB -XNH
-X _ _
NOTES
1. Minimum recommended insertion length (“u” dimension) in liquids is 4 inches and in gases is 6 inches for standard 3⁄8 × 3˝ bulb.
2. Thermowells must be used on any application where the bulb of the thermometer may be exposed to pressure, corrosive fluids, or velocity. Additionally, the use of a thermowell permits instrument interchangeability or recalibration without shutting down the process.
All specifications are subject to change without notice.
All sales subject to standard terms and conditions. ©2018 Ashcroft Inc. 600A-02_Duratemp_ds_(LR), Rev. B, 04/19
ashcroft.com
info@ashcroft.com
1.800.328.8258
of 32
Loading...
+ 2 hidden pages