Extreme resistance to shock and vibration Exclusive movementless design eliminates wear
and increases product life
No head or elevation error due to bulb placement Ideal for extreme process temperatures Maxivision® dial for precise readings
(minimize parallax reading errors)
Multiple case sizes 4½˝ & 6˝ with surface and
lower connections
Gas-operated molecular sieve
TYPICAL USES
Offshore oil rigs Chemical and petrochemical plants Water and wastewater temperature control Pulp and paper Refineries Power General industrial Equipment skids HVAC Pharmaceutical/biotech Food and beverage
SPECIFICATIONS
Accuracy: ±1% of span
Sizes: 41⁄2˝ or 6˝
Range:-300°F/200°F to 400°F/1200°F
(-200°C/100°C to 200°C/650°C)
Over Range:125% of span
Mounting & Connection: Surface/Lower
Bulb Size:3˝ Long x 3⁄8˝ O.D.
Bulb Style:12˝ Bendable extension with 1⁄2 NPT union connection
Plain bulb with rigid extension no union
Plain bulb with rigid extension 1⁄2 NPT union on armor
18˝ Bendable extension with 1⁄2 NPT union connection
24˝ Bendable extension with 1⁄2 NPT union connection
Line Length:5ft to 80ft in standard increments
Dial:Maxivision® anti-parallax dial, black markings on
a white dial
Head/Elevation Error: None
Hand Set:Stationary red hand set, Externally adjustable
red set hand
Pointer:Adjustable Min./Max.
Electric Contacts:High and low, double high, double low, off at low
or high and on in-between
C-600A-03
41⁄2˝, 6˝ dial sizes
KEY BENEFITS
• Black coated aluminum case
• Threaded ring for easy glass replacement or
pointer adjustment
• Extremely versatile for use on many
applications
• 5 year limited warranty
THERMAL SYSTEM
Bulb/Bendable ext.
Material
316 SS
NON-WETTED COMPONENTS
WindowCaseRing
Glass (STD.),
Shatterproof glass,
Plastic, Non-glare glass (OPT.)
Armor MaterialCapillary MaterialConnection Material
AISI 302 Spring
Armor
Aluminum, threaded ringAluminum
TEMPERATURE LIMITS
VersionAmbient
Dry160°F (71°C)
316 SS316 SS
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
B01 - 12˝ Bendable extention with 1⁄2 NPT union connectionB01
B03 - Plain bulb with rigid extention, no union
B08 - Plain bulb with rigid extention, 1⁄2 NPT union on armor
B17 - 18˝ Bendable extention with 1⁄2 NPT union connection
B18 - 24˝ Bendable extention with 1⁄2 NPT union connection
Armor Style
A1 - SS springA1
Line Length (Capillary length is measured from bottom of case to top of bulb extention)
L01 - 5´L01
L03 - 10´
L07 - 20´
L09 - 30´
L13 - 50´
L19 - 80´
Ranges (coding example, see range table on page 3 for all standard ranges)
AB - –320/200°FAB
Options (If choosing an option(s) must include an “X’’)-X _ _
CS - Dual scale
DM - Dial marking
ED - High and low electric contacts
EE - Double high electric contacts
EF - Double low electric contacts
EG - Electric contacts off at low or high and on in-between
EO - Externally adjustable red set hand
EP - Externally adjustable maximum pointer
EQ - Externally adjustable minimum pointer
NG - Non-glare glass
NN - Paper tag
NH - SS tagNH
PD - Plastic window
SG - Shatterproof glass
SH - Stationary red set hand
C-600A-03-C02
B01A1L01AB-XNH
NOTES
1. Minimum recommended insertion length (“u” dimension) in liquids is 4 inches and in gases is 6 inches for standard 3⁄8˝ × 3˝ bulb.
2. Thermowells must be used on any application where the bulb of the thermometer may be exposed to pressure, corrosive fluids, or velocity.
Additionally, the use of a thermowell permits instrument interchangeability or recalibration without shutting down the process.
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
The compression fitting fastens anywhere
along the armored line. This Bulb Style is well
suited for insertion requirements in excess
of 131⁄2˝. The B08 style is not a pressure tight
connection. A thermowell is recommended for
this style and for all bulb styles.
Bulb
Code
B01
B17
B18
ashcroft.com
info@ashcroft.com
1.800.328.8258
Bulb Size
B
3
[76]
3
[76]
3
[76]
S
A
MAX.S MIN.
12
[305]15[381]4[102]
18
[457]21[533]4[102]
24
[610]27[686]4[102]
Style B01, B17 & B18
Are bendable extensions with union connections. B01 [12˝ bendable extension] is the standard Duratemp bulb style and is suitable for
a variety of insertion lengths and lagging requirements. B17 is a 18˝ bendable extension,
B18 is a 24˝ bendable extension. The union
connection on all three styles is pressure tight
and can be freely moved the entire length of
the bendable portion. After installation, the
bendable extension may be formed to suit the
application.
Armor Style A1
AISI 302 stainless steel spring armor is supplied as standard. Originally designed for U.S.
Navy Hi Shock thermometers
of 33
Page 4
Data Sheet
D
B
J
A
C-600A-03 Duratemp® Thermometer
DIMENSIONS
For reference only, consult Ashcroft for specific dimensional drawings
Dial
Size
Inches
41⁄2
6
UnitsABCDEJLV
Inches
mm
Inches
mm
5.792.08 5.031.334.660.30.222.38
147.152.8127.833.8118.37.65.660.5
7.56 3.5 6.35 1.660.60.283.19
192.088.9161.340.6152.415.27.181.0
C
V
3-L dia. holes
on E dia. Bolt Circle
All specifications are subject to change without notice.