Ashcroft C-600A-02 Specifications

Page 1
Data Sheet
C-600A-02 Duratemp® Thermometer
FEATURES
 Extreme resistance to shock and vibration  Exclusive movementless design eliminates wear and
increases product life
 No head or elevation error due to bulb placement  Maxivision® dial for precise readings
(minimize parallax reading errors)
 Multiple case sizes 4½˝, 6˝, 8½˝ back connection, flush
mounted for panel mounting
 Gas-operated molecular sieve
TYPICAL USES
 Offshore oil rigs  Chemical and petrochemical plants  Water and wastewater temperature control  Pulp and paper  Refineries  Power  General industrial  Equipment skids  HVAC  Pharmaceutical/biotech  Food and beverage
C-600A-02
41⁄2˝, 6˝, 81⁄2˝ dial sizes
SPECIFICATIONS
Accuracy: ±1% of span
Sizes: 41⁄2˝, 6˝ or 81⁄2˝
Range: -320°F/200°F to 400°F/1200°F
(-200°C/100°C to 200°C/650°C)
Over Range: 125% of span
Mounting & Connection: Flush/Rear
Bulb Size: 3˝ Long x 3⁄8˝ O.D.
Bulb Style: 12˝ Bendable extension with 1⁄2 NPT union connection
Plain bulb with rigid extension no union Plain bulb with rigid extension 1⁄2 NPT union on armor 18˝ Bendable extension with 1⁄2 NPT union connection 24˝ Bendable extension with 1⁄2 NPT union connection
Line Length: 5ft to 80ft in standard increments Dial: Maxivision® anti-parallax dial, black markings on
a white dial Head/Elevation Error: None Hand Set: Stationary red hand set or Externally adjustable
Red set hand Pointer: Black, aluminum Electric Contacts: High and low, double high, double low, off at low
or high and on in-between
KEY BENEFITS
• Epoxy coated aluminum case
• Hinged ring for easy glass replacement or pointer adjustment
• Extremely versatile for use on many applications
• 5 year limited warranty
• Ideal for extreme process temperatures
THERMAL SYSTEM
Bulb/Bendable ext.
Material
316 SS
NON-WETTED COMPONENTS
Window Case Ring
Glass,
Safety glass,
Acrylic
Armor Material Capillary Material Connection Material
AISI 302 Spring
Armor
TEMPERATURE LIMITS
Version Ambient
Dry -13°F (-25°C) to 160°F (71°C)
316 SS 303 SS
Aluminum Aluminum hinged ring
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
©2018 Ashcroft Inc. 600A-02_Duratemp_ds_(LR), Rev. B, 04 /19
of 41
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 2
Data Sheet
C-600A-02 Duratemp® Thermometer
ORDERING CODE Example:
Case Style
C-600A-02-C12 - 41⁄2˝ Case size, aluminum hinged ring, flush mount, rear conn. C-600A-02-C12
C-600A-02-C27 - 6˝ Case size, aluminum hinged ring, flush mount, rear conn.
C-600A-02-C35 - 81⁄2˝ Case size, aluminum hinged ring, flush mount, rear conn
Bulb Style - (Note 1)
B01 - 12˝ Bendable extension with 1⁄2 NPT union connection B01
B03 - Plain bulb with rigid extension, no union
B08 - Plain bulb with rigid extension, 1⁄2 NPT union on armor
B17 - 18˝ Bendable extension with 1⁄2 NPT union connection
B18 - 24˝ Bendable extension with 1⁄2 NPT union connection
Armor Style
A1 - SS spring A1
Line Length (Capillary length is measured from bottom of case to top of bulb extension)
L01 - 5´ L01
L03 - 10´
L07 - 20´
L09 - 30´
L13 - 50´
L19 - 80´
Ranges (coding example, see range table on page 3 for all standard ranges)
AB - –320/200°F AB
Options (If choosing an option(s) must include an “X’’)
CS - Dual scale
DM - Dial marking
ED - High and low electric contacts
EE - Double high electric contacts
EF - Double low electric contacts
EG - Electric contacts off at low or high and on in-between
EO - Externally adjustable red set hand
EP - Externally adjustable maximum pointer
EQ - Externally adjustable minimum pointer
NH - SS tag
PD - Acrylic window
SG - Shatterproof glass SG
SH - Stationary red set hand
TK - Tank car thermometer (Only available on C-600A-02-C35)
C-600A-02-C12
B01 A1 L01 AB -XSG
-X _ _
NOTES
1. Minimum recommended insertion length (“u” dimension) in liquids is 4 inches and in gases is 6 inches for standard 3⁄8 × 3˝ bulb.
2. Thermowells must be used on any application where the bulb of the thermometer may be exposed to pressure, corrosive fluids, or velocity. Additionally, the use of a thermowell permits instrument interchangeability or recalibration without shutting down the process.
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
©2018 Ashcroft Inc. 600A-02_Duratemp_ds_(LR), Rev. B, 04 /19
ashcroft.com
info@ashcroft.com
1.800.328.8258
of 42
Page 3
Data Sheet
r
S
3
Adjustable Union Connection on Armor
C-600A-02 Duratemp® Thermometer
SINGLE RANGES
Range Code
AB –320°F/200°F AY –200°C/100°C
AE –100°F/100°F BL –80°C/40°C
AG –40°F/180°F BN –40°C/80°C
AK 20°F/240°F BS 0°C/120°C
AL 50°F/300°F BT 10°C/150°C
AN 50°F/550°F BU 0°C/300°C
AR 50°F/750°F BW 0°C/400°C
AT 400°F/1,200°F BJ 200°C/650°C
Range Code
DIMENSIONS in [ ] are millimeters
13-1/4˝ [336]
DUAL RANGES
Range Code
CE 0°C/120°C and 20°F/240°F
CF 0°C/300°C and 50°F/550°F
DR 10°C/150°C and 50°F/300°F
DT –40°C/80°C and –40°F/180°F
For reference only, consult Ashcroft for specific dimensional drawings
13
/16 Hex [21]
7
/8 Hex [22]
1
/2˝ NPT
1
1-
/16˝ [27]
Dia. Clearance Hole
Min. 7-1/4˝
Max. Line
S
[184]
Length
7
/16 Hex [11]
Adjustable Union Connecto
5
/8 Wrench Flats [16]
1
/2 NPT
15
/16 [24] Clearance Hole
3
/16 [4,7] Dia.
Bendable Extension
A
3˝ [66] Sensitive
/8˝ Dia.
[10]
Portion
Style B03
13˝ plain bulb for applications used in open tanks where pressures and velocities are negligible
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
©2018 Ashcroft Inc. 600A-02_Duratemp_ds_(LR), Rev. B, 04 /19
1
7-
/4˝
[184]
[76]
3
/8˝ Dia.
[10]
Sensitive
Portion
Style B08
The compression fitting fastens anywhere along the armored line. This Bulb Style is well suited for insertion requirements in excess of 131⁄2˝. The B08 style is not a pressure tight connection. A thermowell is recommended for this style and for all bulb styles.
Bulb
Code
B01
B17
B18
Bulb Size
ashcroft.com
info@ashcroft.com
1.800.328.8258
B
[76]
[76]
[76]
A
3
3
3
12
[305]15[381]4[102]
18
[457]21[533]4[102]
24
[610]27[686]4[102]
S
MAX.S MIN.
3
/8 [10] Dia.
Sensitive Portion
B
Style B01, B17 & B18
The bendable extensions with union con­nections. B01 [12˝ bendable extension] is the standard Duratemp bulb style and is suitable for a variety of insertion lengths and lagging requirements. B17 is a 18˝ bendable extension, B18 is a 24˝ bend­able extension. The union connection on all three styles is pressure tight and can be freely moved the entire length of the bendable portion. After installation, the bendable extension may be formed to suit the application.
Armor Style A1
AISI 302 stainless steel spring armor is supplied as standard. Originally designed for U.S. Navy Hi Shock thermometers
of 43
Page 4
Data Sheet
hole
LL
FLUSH PANEL MOUNTING
equally spaced on E dia. B.C.
B
Hole in
LL
C-600A-02 Duratemp® Thermometer
DIMENSIONS in [ ] are millimeters
Dial Size
Inches
41⁄2
6
81⁄2
3 Mounting studs CC threaded equally spaced on E dia. B.C.
A B C CC E F K M LL S U
4.75
2.19
[120.7]
4.88
[123.7]
4.75
[120.7]
C
[56]
2.25 [57]
2.25 [57]
6.03
[153]
7.5
[190.5]
9.97
[352]
B
U
Nuts & washers not supplied by Ashcroft
S
K
10-24
0.25 - 20
0.25 -20
A
F
M
Dia. in panel
5.38
[137]
7
[178]
9.63
[244]
For reference only, consult Ashcroft for specific dimensional drawings
1.63
1.06
[41]
2.13 [54]
2.13 [54]
3 Mounting studs CC threaded
4.88
[27]
[124]
1.06 [27]
6.5
[165]
1.06 [27]9[229]
C
0.13 0.5 [3] [13]
0.13 0.5 [3] [13]
0.13 0.5
[3] [13]
K
0.63 [16]
0.63 [16]
0.63 [16]
Nuts & washers not supplied by
S
Ashcroft
0.75 [16]
0.75 [16]
0.75 [16]
A
M
F
panel
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
©2018 Ashcroft Inc. 600A-02_Duratemp_ds_(LR), Rev. B, 08 /18
ashcroft.com
info@ashcroft.com
1.800.328.8258
of 44
Loading...